Archive: December 23, 2022

板式一次性過濾器

2019年05月16日 空氣過濾器 354 views


產品特性:

l   外框:紙質、鍍鋅鋼板、鋁合金

l   外框厚度:21、46、96MM等

l   濾料:高容塵量低阻力聚酯纖維

l   最高溫度:80℃

l  最高濕度:99%

l   效率:G2、G3、G4(EN779) 

產品應用:

l   空調與通風系統的預過濾,避免系統內部積灰污染

l   大型空壓機預過濾

l   潔凈室集中通風空調系統的迴風過濾,延長高等級過濾器使用壽命

l   普通工業廠房的通風系統,達到對空氣的一般潔凈需求

l  一般建築大樓空調的粗過濾

初阻力-風量關係曲線圖

常用規格及性能參數

  

外形尺寸

額定風量

(m3/h)

初始壓降

(Pa)

過濾面積

(m2)

  

(mm)

××(mm)

  

高風量

  

高風量

PP-12×24×1

290×595×23

600

1200

20

63

0.40

19

PP-20×14×1

493×341×23

550

1100

0.39

PP-20×15×1

493×366×23

625

1250

0.43

PP-20×16×1

493×391×23

650

1300

0.45

PP-20×20×1

493×493×23

800

1600

0.56

PP-20×24×1

493×595×23

950

1900

0.65

PP-24×24×1

595×595×23

1200

2400

0.83

PP-25×14×1

620×341×23

700

1400

0.48

PP-25×16×1

620×391×23

800

1600

0.57

PP-25×20×1

620×493×23

1000

2000

0.71

PP-14×20×2

341×493×46

850

1700

20

70

0.77

20

PP-20×12×2

493×290×46

700

1400

0.70

PP-20×16×2

493×391×46

900

1800

0.94

PP-20×18×2

493×442×46

1050

2100

1.01

PP-20×20×2

493×493×46

1200

2400

1.12

PP-24×12×2

595×290×46

850

1700

0.79

PP-24×18×2

595×442×46

1300

2600

1.24

PP-24×20×2

595×493×46

1400

2800

1.36

PP-24×24×2

595×595×46

1700

3400

1.64

PP-25×16×2

620×391×46

1200

2400

1.18

PP-25×18×2

620×442×46

1350

2700

1.27

PP-25×20×2

620×493×46

1500

3000

1.42

PP-20×16×4

493×391×96

950

1900

18

68

1.45

28

PP-20×20×4

493×493×96

1200

2400

1.73

PP-24×12×4

595×290×96

850

1700

1.28

PP-24×18×4

595×442×96

1300

2600

1.91

PP-24×20×4

595×493×96

1400

2800

2.09

PP-24×24×4

595×595×96

1700

3400

2.55

PP-25×16×4

620×391×96

1200

2400

1.82

PP-25×20×4

620×493×96

1500

3000

2.18

PP-25×29×4

620×721×96

2150

4300

3.27

1、若遇規格、結構變更,以本公司提供的最新數據為準

2、本公司接受非表上規格過濾網產品的訂貨

更多內容 網址: www.ecolead.cn 電話: 025-57138032

Medical waste incineration system

Medical waste incineration system of 300 kg/hr burn rate with dual fuel (gas and diesel) type, daily 8-16 hrs operation and a stack height of 15 meter.Primary combustion
i.    The primary combustion chamber shall be accepted as the primary combustion zone;
ii.    The minimum combustion temperature of the primary chamber shall not be less than 800 degrees C;

Secondary combustion
The residence time in the secondary chamber shall not be less than 2 seconds;
The gas temperature as measured against the inside wall in the secondary chamber, not in the flame zone, shall not be less than as indicated in Lots 1-7 ;
Both the primary and the secondary temperatures shall be maintained until all the waste has been completely combusted;

Chimney
The chimney shall have a minimum height of 4 meters above ground level;
The minimum exit velocity of the emissions shall not be less than 10 metres/second;1.    Capacity of destruction in weight: 60 Kg/h.
2.    It should be able to operate not less than 10 hours/day
3.    This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
4.    Design Specification : Types A, B, C, D, and E of medical waste
5.    “PYROLYTIC” combustion, by controlling the gasification of waste.
6.    The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.
7.    It should be able to reduce the volume of wastes by 98%.
8.    It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.
9.    The incineration should be completely free from visible smoke as well as offensive odours.
10.    The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
•    The Temperatures of combustion: Minimum will be 850oC and max 1400oC
•    Post combustion: >1100oC.
11.    The Internal diameter of the Chimney: Ø 400 and its height: 8 m
12.    The Volume of the combustion chamber: 1.200 L
13.    The Dimension of the door for loading in cm: 70×70.
14.    Burner operation should be Automatic On/Off
15.    Fuel : diesel
16.    The supplier must provide  necessary information for the best of  the installation
This incinerator with “PYROLYTIC” combustion must have:
17.    A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
* A burner of lighting which the use is limited to the ignition of waste.
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks in order to assure a minimum temperature on   the outside sheet metal.
* Composition of the refractory;
•    Refractory concrete :
    . Thickness    : ≥100 mm
    . Nature: 42% of Al203
•    Insulate in fibrous panels :
    . Thickness: ≥75 mm
•    Nature: Calcium silicate.
* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.

18.    A chamber of post combustion of gases
* A burner of combustion of gases,
* A device of injection of air allowing a total recombustion of gases,
* A device of air inlet of cooling of waste gases,
* A sheath of evacuation of the gases burnt.
* Carcass in strong sheet steel with support of connection.
* Composition of the refractory;
•    Refractory concrete :
    Thickness    : ≥150 mm
    Nature: 65% of Al203
•    Insulate in fibrous panel :
    Thickness: ≥85 mm
     Nature: Calcium
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of     electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
* A secondary injection of air to ensure perfect oxygen content.
19.    A control box ensuring the complete cycle of combustion.

20.    Fan:
* Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle.
21.    Controls and regulations:
Control box watertight to dust, including:

* A switch circuit breaker for each engine (ventilators and burners).
* A timer with adjustable temporization for the regulation of each burner.
* A regulator with digital watching for the temperature of combustion.
* A regulator with digital watching for the temperature of postcombustion.
* Electric box.

21. The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual batch de ashing.
22. Process Filtering system: Scruber to be mentionned as optional
23. Emission Standards Compliance: BS 3316 or équivalent standard
23. Capacity to treat Plastic: Not less than 40% by weight
24. CE Manufacturing Compliance: BS EN 746-2-1997
22.    The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
23.    The installed incinerator must bear a one year guarantee.
24.    The supplier shall perforn an onsite installation of the incinerator.
25.    The technical training of operators will have to be provided and given by a technician
from the factory; it will consist of curative and preventive maintenance, and the use of machine, etc

petit incinérateur de déchets de centre de santé

INCINÉRATEUR DE DÉCHETS

– 150 kg / heure

– Conforme aux règles de l’UE, Directive 2000/76 / CE

– Type de carburant: Diesel

– Gestion et maintenance faciles

– Températures:

850 ° C pour les déchets municipaux

1000 deg C pour les déchets médicaux

1100 ° C pour les déchets dangereux contenant des substances organiques halogénées avec une teneur en chlore ou ses composés.un incinérateur avec une capacité de combustion moyenne de 20-30kgs par heure et il devrait diesel ou huile moteur usagée, INCINÉRATEURS MÉDICAUX, CAP: 3 TONNES.producteur de petit incinérateur de déchets hospitaliers – pour nos clients (hôpitaux)

Waste Incinerator

Basic Info.

Model NO.:waste incineration furnace
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Containerized incinerator ts500, controlled air dual chamber incinerator capacity, convo fuel, corpse incinerator, cost for incineration for pets, cost of a cremation furnace used for pets, Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Animal body components , various other biomedical waste , body organs dung


51.No    Features    $_pecific tions
1    (Incinerator)
Type of waste for disposal    Animal  body  parts,other  biomedical  waste,organs dung, bedding materials,plant p缸ts and food itemsι
Incinerators for conversion of waste to fine,white sterile
ash with no visible smoke or odour
2.    Load capacity    300 – 4∞Kg (maximum)
3.    Bum capacity    100 Kgjhr (minimum)
4    Fuel    Diesel (LDOjHSD)
5.    Type of Bumer operation    Automatic diesel fired
6.    Primary chamber    Solid hearth
Dense refractory concrete lining
Operating temeeralure of 850 土 50 deg C or more
7.    Secondary chamber    Slid heath
Dense refractory concrete lining
Opera恤19 temperature of 1∞o deg C or more
8.    Temperature control    Digital temperature control and display
Temperature monitoring and thermostatic control
9.    Power supply    220V for control Box
10    Size    Compact design preferred
11.    Opening lid    Large top open归g lid (Approx . 700 mm x 500mm) for
easy loading
12.    Fuel tank    100-150 L

13.    Civil    works,    installation    and
comnuss!Onmg    lndusive  of  civil  works  (brick  wall  incinerator  house
with a shutter door,CGI sheet roofing) according to 由e
model of the incinerator.
lnstallation and commissioning of the incinerators including hiring of heavy machineries requ让ed at the time of instalIation .
Electric power supply line to light incinerator house as well as to control box of the incinerator
Onsite  demonstrationjperformance  test  and  adequate training of staff on the use of incinerators.
Warranty of one year from the date of commissioning. Separate   Annual    Maintenance    Contract   would    be drawn with the supplier at a later stage.
14.    Catalogue    Catalogue containing detail pictures and spec迁ications
of  the  quoted  incinerator  must  be  included  in  the
bidding document


Smallest Waste Incinerator for PPE waste face mask glove waste

Smallest Waste Incinerator for PPE waste face mask glove waste
Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney
ave 10kgs per hour, 100kgs per day(10hr/day working)

Equipment Technical Specifications

Model

YD-10

Picture

 

Feed Capacity

Typical 20 kgs per feeding

Burning Rate

Typical 10 kgs per hour

Burning Time per Feed

2 hours

Voltage

220V

Power

0.5Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

Ave. 4.2 Kgs/Hour

External Dimensions

Dia.100 x 130cm (mainbody)

Internal Dimensions

Dia.50 x 80cm

Waste combustion chamber

200Liters

Oil Tank Capacity

100 Liters

Door Opening

35 x 35cm

Chimney

1.5M

Gross Weight

Ave.400kgs

Chamber Material

Refractory Concrete&Ceramic Fiber 

Max.

42,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

14000C

Burning efficiency

>98%

Waste Lower Calorific Power

3000Kcal

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

Hiclover waste incinerator

Key Features:

— Full range incinerator with Economized Small Scale incinerator, Standard Small-Large Scale incinerator, 

General Municipal Solid Waste Incinerator, Pet and Animal Cremation, Containerized Mobile Incinerator, 

High Efficient Environmental Waste Incinerator.

— Single combustion chamber, double combustion chambers, three combustion chambers and 

multi-combustion chambers waste incinerators.

— System solutions for medical waste environmental.

— High burn rate, from 5kgs to 1000kgs per hour.

— New Design for pet animal cremation business.

— HICLOVER, trusted partner with years of experience.

HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental 

protection, animal and pet cremation engineering, other municipal solid waste incineration project.

We supply single combustion chamber, double combustion chambers, three combustion chambers and 

multi-combustion chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene 

clinical waste destruction with medical disposable, biological waste, medical plastic waste, hazardous waste, 

red bag waste, needle disposal, gauze and bandages, sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.

      

Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, 

cattle farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber 

again to make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

System solutions for medical waste environmental, including waste incineration, smoke emission treatment, 

high-temperature sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste 

package, sharp containers, etc.

The pet cremation equipment humanized design with movable platform, small space covers for modern pet 

cremation business owner all over the world.

The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no 

incineration house build construction, movable by truck and ultraviolet lamp sterilization inside.

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, 

Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner 

for governmental organizations, non-profit organizations, international contractors, logistics organizations, 

military, pet cremation business owners, etc. We have export experience more than 40 countries, including 

war zone like Iraq, Afghanistan, Somalia, South Sudan.

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for 

incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, 

pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small 

animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer 

reduce purchase budget, custom made function, quality products and friendly service.



HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-12

Incinerador agrícola

Información básica.

Modelo NO .: equipo de animales de granja cremación creamatotium incin
Mercados de exportación: Global

Descripción del producto

Características principales:
* Todos los modelos con doble cámara de combustión.
* Chimenea / chimenea de acero inoxidable, larga vida útil. * según pedido
* Alta temperatura, larga vida útil del incinerador.
* Instalación gratuita o mínima en obra.
* Alta velocidad de combustión, de 10 kg a 500 kg por hora, hasta 6 toneladas por día.
* Plano de control PLC. * según pedido
* Nuevo diseño para el negocio de cremación de animales de compañía.
* Garantía de un año en incinerador y piezas en stock.

Ámbito de aplicación:
1. Hospital y clínica: Residuos Iátricos, Residuos Infecciosos, Vendajes, Biorresiduos, Medicina.
2. Matadero y hospital y granja de mascotas: animal muerto, biorresiduos.
3. Comunidad, puerto y estación marítima: residuos sólidos urbanos, etc.
4. Laboratorios, ubicaciones remotas, operaciones de socorro en casos de desastre, cremación de animales

Incinerator es un equipo de incineración, China de oxidante térmico de fuego directo, China de oxidante térmico, oxidante térmico, incinerador de eliminación de desechos de gases tóxicos, proveedor de desechos tóxicos en China, incinerador de cadáveres de animales montado en un remolque, desechos por gas combustible o combustible de oi. Como circunscripción diferente, incinerador se puede nombrar muchas palabras como se muestra a continuación:

Capacidad de tratamiento: incinerador de pequeña escala, incinerador de gran escala y pantalón de incineración.

Material de desecho: incinerador de desechos municipales, incinerador de desechos médicos, incinerador de cremación de animales, incineradores humanos

Combustible del incinerador: incinerador de gas, incinerador de petróleo

Conversión de residuos en energía (WTE): incinerador WTE, incinerador sin WTE

Fabricante de incineradores: fabricante de incineradores de China, fabricante de incineradores de Reino Unido, fabricante de incineradores de EE. UU., Fabricante de incineradores de India.

Famosa empresa fabricante de incineradores: Inciner8 (Reino Unido), Clover Incinerator (China), Pennram (EE. UU.), Haat (India)

Velocidad de combustión: 5 kg / hora, 10 kg / hora, 15 kg / hora, 20 kg / hora, 30 kg / hora, 50 kg / hora, 100 kg / hora, 150 kg / hora, 300 kg / hora, 500 kg / hora

Artículos / Modelo YD-200 YD-300 YD-500 YD-600
Tasa de combustión (kg / hora) 200 kgs / Hr. 300 kgs / Hr. 500 kgs / Hr. 600 kgs / Hr.
Capacidad de alimentación (kgs) 400 kilogramos 500 kilogramos 800 kilogramos 1100 kilogramos
Peso del equipo 7600 kilogramos 8300 kilogramos 13000 kilogramos 16500 kilogramos
Cámara primaria (litros) 2000 2400 4000 5500
Cámara secundaria (litros) 500 1200 1500 1500
Dimensiones externas (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Dimensiones internas (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Tanque de aceite (litros) 300 500 500 500
Apertura de la puerta (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimenea (M) 10 10 14 14
Tipo de chimenea Acero inoxidable Acero inoxidable Acero inoxidable Acero inoxidable
Cámara secundaria
Cámara de mezcla de combustión
Cámara de filtro de humo
Combustible de combustión Gas de petróleo Gas de petróleo Gas de petróleo Gas de petróleo
Tiempo de residencia 2,0 seg. 2,0 seg. 2,0 seg. 2,0 seg.
Monitoreo de temperatura

incinérateur de déchets de centre de santé conteneurisé

Un 40 ′ ′ ′ ′ Besoin – – – – Réchauffeur conteneurisé, et comprenez également que vous pouvez nous aider avec l’achat du même type de déchets ou application: Général en plus des médicaments

Capacité kgs / ressources humaines: 75 à 350
Centre clinique et appareils de laboratoire.

Parmi nos précieux clients, il est intéressé d’acquérir un appareil de chauffage pour déchets hospitaliers conformément aux spécifications:

Chauffage des déchets pour centres de santé
Capacité: 50 Kg / Hr
Un tout nouveau système de travail global
Brûleurs: double décharge (gaz et aussi diesel).
Conteneur de 20 pieds avec une usine d’incinération pour la fusion des déchets solides comprenant les éléments importants suivants:

1. INCINÉRATEUR.
2. PARE-ÉTINCELLES.
3. LOT DE GAZ DE FUMÉE / TUYAU D’ÉCHAPPEMENT.
4. HUILE DIESEL DAYTANK 400 L WEB.
5. SYSTÈME DE GESTION DES INCENDIES INCLUS.
6. GUIDE DU CLIENT.
7. COMPOSANTS SUPPLÉMENTAIRES POUR 1 AN DE PROCÉDURE.
l’incinérateur de déchets médicaux fait de 2,5 à 3 mètres cubes et sa capacité est en outre de 60 à 100 kg par heure.