Archive: April 30, 2022

Needs for Twin Chamber Heater

Industrial waste.|The minimal passing rate of the discharges won’t be less than 10metres/second.
1 x diesel oil fired ignition heating units ran on/off.
CONTAINERISATION.
1 year extra components, gas containers as well as 10metre pipe ahead typical with every heater.
The home time in the second room will certainly not be a lot less than 2 secs.
Both the additionally additional as well as primary temperature levels will be preserved till all the waste has really been completely ignited.
Chimney.
Industrial waste.
SMOKESHAFT.
CONTROL PANEL.
CE certified or equivalent for burners of the measurement and also design.
Running together with maintenance handbooks.
(adsbygoogle = window.adsbygoogle || []).push({});
Thermostatic Control.
High quality refractory lining together with insulation.
When the second temperature level drops to listed below the required temperature level, a distinct and/or recognizable alarm to alert the operator.
Timer control 0- 12 hrs.
Substantial full dimension leading lots door and also fluid retention sill.
The primary burning chamber will be approved as the vital burning area.
Trailer mounted mobile burner tools excellent for the following applications.
Thaw rate 150kg/h minimum
The minimum burning temperature of the very important room shall not be much less than 800 degrees c.
Resilient steel case.
Automatic Control.
0.6 m refractory lined stack.
Incinerator completely mounted within 10 ft ISO accredited container.
The chimney will have a very little height of 4 metres over ground level.
General.
This system performs at over 1100 ° C at the very important room to guarantee total combustion. This design likewise benefits
Outstanding quality refractory lining as well as insulation.
Temperature level Monitoring.
Burner placed on the silenblock padding.

Cycle time developed.
Pet cadavers.
ANCILLARIES.

pet incinerator for sale

1.    Capacity of destruction in weight: 60 Kg/h.
2.    It should be able to operate not less than 10 hours/day
3.    This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
4.    Design Specification : Types A, B, C, D, and E of medical waste
5.    “PYROLYTIC” combustion, by controlling the gasification of waste.
6.    The incinerator must avoid the release of black smoke and fine dust, during the loadings.
7.    It should be able to reduce the volume of wastes by 98%.
8.    It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.
9.    The incineration should be completely free from visible smoke as well as offensive odours.
10.    The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
?    The Temperatures of combustion: Minimum will be 850oC and max 1400oC
?    Post combustion: >1100oC.
11.    The Internal diameter of the Chimney: ? 400 and its height: 8 m
12.    The Volume of the combustion chamber: 1.200 L
13.    The Dimension of the door for loading in cm: 70×70.
14.    Burner operation should be Automatic On/Off
15.    Fuel : diesel
16.    The supplier must provide  necessary information for the best of  the installation
This incinerator with “PYROLYTIC” combustion must have:
17.    A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
* A burner of lighting which the use is limited to the ignition of waste.
* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.

Modèle de brûleur de déchets médicaux pour appareil de chauffage mobile en conteneur CA50

HICLOVER – Incinérateur de déchets médicaux d’incinérateur mobile conteneurisé modèle CA50


Version

CA50

Image

Thérapie des déchets

Thérapie d’incinération des déchets médicaux

Capacité d’alimentation

Régulier 100 kg par repas

Prix brûlant

Normalement 50 kg par ressources humaines

Durée de combustion par alimentation

Moyenne 2 h

Réglage de contrôle

PLC (Incinérateur de contrôleur de raisonnement programmable)

Tension

220V

Pouvoir

1,0 Kw

Gaz

Diesel

Chauffe-eau

Brûleur d’Italie

Réglage de l’alimentation

Manuel

Affichage du degré de niveau de température

Présent numérique

Prise de carburant (huile)

Moyenne 16,9 kg / heure

Capacités intérieures

100x80x70cm (chambre clé)

Dimensions extérieures

230 x 130 x 155 cm (texte)

Chambre de fusion des déchets

560 litres

Message Burning Chamber

280 litres

Capacité du réservoir d’huile

200 litres

Ouverture de porte

70 x 50 cm

Smokeshaft

5,0 M

Poids brut

4500kgs

Produit de chambre

Brique réfractaire, béton réfractaire

Max.

Spécifications techniques du traitement

Niveau de température de la chambre solide

8000C -10000 C

Température de la chambre à gaz

10000C -12000 C

Chambre anti-taux

17500C

Temps de résidence

2,0 sec.

2,0 sec.

Efficacité brûlante

> 98%

Déchets de puissance calorifique inférieure

3000Kcal


Incinérateurs de déchets
Incinérateur de déchets médicaux
Crémation d’animaux de compagnie
Déchets solides   Incinérateur

Tél: + 86-25-8461 0201
Mobile: + 86-13813931455 (whatsapp / wechat)
Site Web: www.hiclover.com
E-mail: [email protected]
E-mail: [email protected]
Nanjing Clover Medical Technology Co., Ltd.

24/03/2020

Малый мусоросжигательный завод Yd-50c

описание продукта

Компания Nanjing Clover Medical Technology Co., Ltd. является ведущим производителем мусоросжигательных установок в Китае. Мы – местный производитель и один из крупнейших экспортеров Китая. Техническое оборудование пиролитических инсинераторов – это основная обработка отходов во всем мире, включая медицинские отходы, сжигание животных, кремацию домашних животных и другие твердые отходы. Емкость от 10кг / час. До 500 кг / час, до 6 тонн в день. В настоящее время мы поставляем различные серии в соответствии с требованиями местных клиентов и проектируем обновленную мусоросжигательную печь с использованием наших передовых технологий. Обновленные конструктивные особенности нашего ассортимента мусоросжигательных печей делают их одними из самых экономичных в мире.

Инсинератор YDC является новейшей разработкой для обработки отходов, включая медицинские отходы, кремацию животных и другие твердые отходы. Это качественное оборудование для различных объектов, таких как больница, установка для сжигания животных, цена продажи, установка для сжигания отходов, установка для сжигания фарфора для кремации, установка для сжигания для лабораторий, установка для сжигания лабораторных животных, отдел охраны окружающей среды, агентства по кремации животных и т. Д. Обновлены поставки установки для сжигания отходов CLOVER модели с двойной камерой сгорания, смесительной камерой сгорания и камерой дымового фильтра с огнеупорными трубопроводами и температурой камеры сгорания до 1200 ° C.

Предметы / Модель Ярд-10С Ярд-20С YD-30C YD-50C
Скорость горения (кг / час) 10 кг / час. 20 кг / час. 30 кг / час. 50 кг / час.
Емкость подачи (кг) 40 кг 40 кг 50 кг 80 кг
Вес оборудования 1200 кг 1200 кг 1800 кг 2200 кг
Первичная камера (литры) 200 200 250 400
Вторичная камера (литры) 140 140 140 140
Внешние размеры (см) 170x140x160 170x140x160 170x140x190 180x160x200
Внутренние размеры (см) 55x55x65 55x55x65 55x55x85 70x70x85
Масляный бак (литры) 50 100 100 150
Дверной проем (см) 38 х 48 38 х 48 38 х 48 45 × 55
Дымоход (M) 5 5 5 5
Тип дымохода Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь
Вторичная камера ДА ДА ДА ДА
Камера смешанного сгорания ДА ДА ДА ДА
Камера дымового фильтра ДА ДА ДА ДА
Горючее топливо Нефтяной газ Нефтяной газ Нефтяной газ Нефтяной газ
Время проживания 2.0 сек. 2.0 сек. 2.0 сек. 2.0 сек.
Контроль температуры ДА ДА ДА ДА
1-й. Температура камеры 800 градусов – 1000 градусов 800 градусов – 1000 градусов 800 градусов – 1000 градусов 800 градусов – 1000 градусов
2-й. Температура камеры 1000 градусов-1200 градусов 1000 градусов-1200 градусов 1000 градусов-1200 градусов 1000 градусов-1200 градусов

Medical Incinerator

Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Q: What is kind of waste can use in this equipment? 
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard 
A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity 
A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Burning incenrator manufactuer, burning medical waste, burning waste chamber, buy a portable crematorium, buy a small incinerator, buy animal cremation systems, Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that’s mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. 
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing 
A: We supply all documents and incinerators easy to installation and operation. Customer can send people come to our factory to learn installation and operation. Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order. 

Q: Combustion Temperature 
A: The first combustion chamber: 800-1000 centi degree. 
The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode 
A: Default Control mode is common control case. PLC mode according to model and order. 

Q: Operation and maintenance costs 
A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Infectious Waste Incinerator

Product Description

Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc. 

The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until waste burnout but for some waste like plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner has a fan small incinerator cost, small incinerator lab, small incinerator manufacturer, incinerator medical waste, small incinerator price in china, small incinerator primary chamber secondary, itself for Oxygen supply and also protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion. 

Considering Environmental Protection requirements and rules, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even if third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure sufficient combustion, few black smoke and smell. 

The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other function from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation. 

In some Developed countries, some new waste treatment method like High-temperature cooking, waste carbonization, crushing sterilization technology is instead of incineration technology.

Item Customer Request Example
Application Scope  
 
 
 
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc
What kind of waste?  
____, _____%
____, _____%
____, _____%
 
 
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent
if for animal/pet, indicate animal size like: cat, dog, cattle, etc
Quantity Request    
01.02.03^…unit
 
Budget    
$US Dollar.
 
 
Operating Time    
The staff work Hours per day.
Our incinerator can work up to around 18 hours per day.
Realization Date of project In ___ year  
Waste Output Capacity per Day?  
 
1000kgs Per Day^
Request waste burn rate   Capacity: 100kgs Per hour^
Request waste feed capacity   Capacity: 100kgs per feed^
Whether Natural Gas Supply Local?   Yes or No.
Local Power   If 380V and 220V valid?
Product Installation Destination  
 
Country or City name
DestinationSeaport name?   To check sea freight charge.
 
Customer    
End-Customer, Agent, Government.
 
Method of contract   Tender or Negotiation
Date of Tender limit    
How did you know our company?    
Other request or information  
 
 
 

Incinerator Equipment

Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:Nanjing Clover

Product Description

TS version PLC incinerator is latest layout for waste treatment, include health care waste, animal cremation and other solid waste. This equipment quality structural for types of website, like medical waste maker, medical waste pyrolys, medical waste sterilization”300kg”, medical waste providers china, medical waste treatment china, hospital, environmental division, animal cremation agencies, etc.. CLOVER Incinerator supply updated models with dual combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 degree 800–1000 degree 800–1000 degree 800–1000 degree 800–1000 degree
2nd. Chamber Temperature 1000-1200 degree 1000-1200 degree 1000-1200 degree 1000-1200 degree 1000-1200 degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

PROGRESSED MEDICALWASTE HEATER

Smokeshaft.
1 year Spare Parts Package for complete maintainability.
Gas Diesel/LPG/LNG, please reveal.
Burn Price 150kg/h minimal.
Weight (kg), please recommend:.
Wonderful deal 6– – Mobile Burner.
The minimal leave speed of the discharges shall not be less than 10 metres/second;

Temperature Level Warnings.
HTW Mobile Burner style G.
1 year Spare Components Package for complete maintainability.
Fuel Diesel/LPG/LNG, please suggest.
Item 14 10m Hose pipeline Pipe, suggest size.
dimension. Item 19 1000 Litre Gas Storage Tank + Pipeline System, show quantity.
Weight (kg), please indicate:.
Minimum working temperature level 920 ° C, please indicate.
Point 9 Incinerator design C.
Additional Chamber.
The gas temperature degree as determined versus the inside wall surface area in the second room, not in the flame location, will not be a great deal less than as received Lots 1-7;.
Second Chamber.
Burn Rate 65kg/h minimal.
Merchandise 10 10m Tube pipeline Pipeline, show span.
10m Pipeline Pipeline, show size.
Gas Retention Time – – – – two Secs. Power Supply – for – Control Box – 220V-240V 50Hz lone stage.
Gas – Diesel/LPG/LNG, please program. Power Supply for – Control Box – 220V-240V 50Hz single point. Minimum operating temperature level 850 ° C, please program. 1 year Spare Parts Bundle for complete maintainability. Merchandise 18 10m Hose pipe Pipeline, reveal
Burn Rate 250kg/h minimal.
Control box can be gotten rid of in addition to put on different stand at least 1.5 meters from incinerator at approximately 1.6 meter elevation;

Great Deal 2.
Gas Retention Time – – – – two Secs. Gas – Diesel/LPG/LNG, please suggest –. Power Supply – for – Control Box – 220V-240V 50Hz solitary phase. Minimum running temperature level 850 ° C, please recommend. 1 year Spare Components Plan for full maintainability.
& & Country Issues, or European Union regulations and guidelines.

Thing 17 Mobile Burner version E.
Weight (kg), please suggest:.
1 year Spare Parts Package for complete maintainability.
Power Supply for Control Box – – – – 220V-240V 50Hz singular phase.
Superior deal 5– – Mobile Burner. 2. Incinerator gives 2 room incineration along with holds gasses for at least 2 seconds.
Diesel/LPG/LNG, please suggest.
1000 Litre Gas Storage Tank + Pipeline System, suggest volume

Additional Chamber.
Item 11 I000 Litre Gas Container + Pipeline System, indicate quantity.
3. Each incinerator should have appropriate labelling for parts/areas of top job health and wellness threat on the incinerator.
(adsbygoogle = window.adsbygoogle || []).push({});
2nd Chamber.
Warranty, reveal no of years.
Included chimney expansion, suggest altitude. Guarantee, indicate no of years. The minimum combustion temperature degree of the main room will certainly not be less than 800 degrees C;

Second combustion.
Burn Price 100kg/h minimal.

Item 15 1000 Litre Gas Tank + Pipeline System, disclose amount.
When the secondary temperature drops to detailed below the required temperature level;

General, a noticeable and/or different alarm system to encourage the motorist.
Fuel – Diesel/LPG/LNG, please reveal.
The smokeshaft will have a marginal elevation of 4 meters above ground degree;.
Solution guarantee, show no of years.
Burn Price – – – – 150kg/hour minimal. Weight( kg), please show:.
Item 21 Mobile Burner layout F.
Extra Chamber.
Item 6 10m Tube pipe Pipeline, indicate dimension.
Item 22 10m Hose pipe Pipe, show size.
Weight (kg), please suggest:.
Power Supply for Control Box 220V-240V 50Hz single point.
Power Supply for Control Box 220V-240V, solitary phase 50-60Hz.
Weight (kg), please show:.
Minimum running temperature level 1200 ° C, please reveal.
Extra Chamber.
Burn Price 100kg/h minimal.
1 year Spare Components Bundle for complete maintainability.
The residence time in the second room will not be much less than two seconds;.
Second Chamber.
I000 Litre Gas Container+ Pipeline System, reveal amount.
Merchandise 16 Additional smokeshaft development, reveal altitude.
Minimum running temperature level 1200 ° C, please suggest.
Point 23 1000 Litre Gas Tank + Pipeline System, recommend quantity.
Item 20 Extra chimney expansion, suggest height.
Item 7 I000 Litre Gas Tank + Pipeline System, suggest quantity.
Large amount 3.|
Weight (kg), please indicate:.{
(adsbygoogle = window.adsbygoogle || []).push({});|}
Second Chamber.
Power Supply for Control Box – – – – 220V-240V 50Hz singular phase.
Merchandise 16 Additional smokeshaft development, reveal altitude.
Power Supply for Control Box 220V-240V 50Hz single point.
Point 9 Incinerator design C.
Weight (kg), please show:.
10m Pipeline Pipeline, show size.
Wonderful deal 6– – Mobile Burner.
Solution guarantee, show no of years.
Burn Rate 65kg/h minimal.
Item 21 Mobile Burner layout F.
Second Chamber.
1 year Spare Parts Package for complete maintainability.
3. Each incinerator should have appropriate labelling for parts/areas of top job health and wellness threat on the incinerator.
Item 7 I000 Litre Gas Tank + Pipeline System, suggest quantity.
I000 Litre Gas Container+ Pipeline System, reveal amount.
The residence time in the second room will not be much less than two seconds;.
1 year Spare Parts Package for complete maintainability.
Merchandise 10 10m Tube pipeline Pipeline, show span.
Power Supply for Control Box 220V-240V, solitary phase 50-60Hz.
Additional Chamber.
Additional Chamber.
Burn Price 100kg/h minimal.

pet incinerators

 

The panel and parts hereof shall have the following characteristics:

 

 

 

 

Finish

 

All metal parts shall receive a treatment taking the prevailing environment conditions into account.

 

 

 

 

The top paint colour shall be the Manufacturer’s standard.

 

 

 

 

Auxiliary Wiring

 

 

 

 

All auxiliary wiring shall be carried out with wires having a minimum cross section area of

1.5 mm2.

 

 

 

 

Wiring is connected to terminals blocks in such a way that there is no more than two wires on each terminal.

 

 

 

 

Current wires from current transformers shall be not less than 6 mm2.

 

 

 

 

All wires shall be marked at each end for identification.

 

 

 

 

All markings shall be carried out in compliance with the corresponding circuit diagrams and wiring lists.

 

 

 

 

Cable Termination

 

 

 

 

Auxiliary wires will be terminated to numbered terminals.

 

 

 

 

Main circuit cables will be bolted to numbered bars.

Konsep dan standard kebersihan bilik yang relevan

22 Mei 2019 Berita Industri 500 tontonan

Kebersihan merujuk kepada jumlah habuk (termasuk mikroorganisma) di udara bersih

Kebersihan udara bilik bersih secara amnya memerlukan ujian berikut untuk membuat kesimpulan:

l  Menganggur, ujian statik

Ruang bersih telah dipasang, sistem penghawa dingin bersih beroperasi seperti biasa, dan peralatan dan pengendali produksi dalam ruangan tidak tersedia.

Atau sistem penghawa dingin pemurnian bilik bersih sudah beroperasi normal, peralatan proses telah dipasang, dan pengujian dilakukan tanpa tenaga produksi di dalam ruangan.

l  Jalankan, ujian dinamik

Bilik bersih telah diuji dalam keadaan pengeluaran biasa. Pengesanan volume udara, kecepatan angin, tekanan positif, suhu, kelembapan, dan kebisingan di ruang bersih dapat dilakukan sesuai dengan peraturan penggunaan umum dan pendingin udara yang relevan.

Kebersihan-bilangan jadual perbandingan zarah debu

Keadaan terbiar

Status operasi

gred

Bilangan maksimum zarah per kawasan padu dibenarkan

0.5μm

5μm

0.5μm

5μm

A

3,500

20

3,500

1 *

B

3,500

29

350,000

2,000

C

350,000

2,000

3,500,000

20,000

D

3,500,000

20,000

Tiada syarat khusus

Tiada syarat khusus

Kebersihan-standard EU dan ISO

gred

Keadaan terbiar

Status operasi

Kenyataan

Kelas A

ISO 5

ISO 5

Kawasan tempatan untuk operasi berisiko tinggi

Kelas B

ISO 5

ISO 7

Persediaan dan pengetinan steril

Kelas C

ISO 7

ISO 8

Kawasan proses yang tidak kritikal

Kelas D

ISO 8

Tiada syarat khusus

  Kawasan proses yang tidak kritikal

Lebih banyak URL kandungan: www.ecolead.cn Tel: 025-57138032