How you can find reasonable incinerator for your local site? 
Incinerator is not a cheap equipment, generally the small scale model's price around $5, 000usd per unit and large scale model's price more than $50, 000usd per unit. So, before industrial waste burner, industrial waste burners, industrial waste incinerator, infectious waste incinerator, infectious waste incinerators, purchase one unit incinerator, you have to make clear following items: 
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment? 
B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size. 
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don't have gas supply system. 
And other technology items, like power(220v, 380v), waste feed door type, incinerator structure, etc. 

A Model animal crematory burning rate from 20-400kgs per hour. Heavy duty combustion chamber and suit for large animal cremation. 

Secondary Chamber & Mix-Combustion Chamber. Residency time 2.0 sec. In post combustion chamber. Virtually smoke and smell free. 

Smoke Filter Chamber with filter brick, Virtually smoke and smell free after burning. 

Italy original oil or gas burner, quality reliable. It suit for diesel oil, natural gas, LPG gas. 

User guider, full installation and operation document for customer.

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Picture  
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Signed a contract for automatic rolling curtain air filter of Jiangsu RH environmental protection sewage treatment plant

May 18, 2019 company news 216 views

The environmental protection company is a well-known manufacturer of environmental protection equipment in southern Jiangsu. Relying on the unique advantages of southern Jiangsu , it is one of many environmental protection manufacturers that we cooperate with to establish production and technology development bases. Since the beginning of the company’s establishment, it was heard that our company is mainly engaged in the production of rolling curtain air filters. The responsible persons of both parties have had a strategic meeting and established a long-term cooperative relationship. For example, the continuous procurement contract year after year is a great trust and support for our company’s products and services. Our company has long been committed to the production and sales of roller shutter air filters and filter cotton . Welcome to call or write for consultation.

More content URL: www.ecolead.cn Tel: 025-57138032

large animal incinerators

The incinerator shall also be equipped with special loading devices and mechanisms that allow safe incineration of

solid waste simultaneously with liquid sludge. Loading of solid waste may be achieved through bags.

 

All intermediate piping, bellows and other fittings for connection between the tanks

, burner, compressor and other equipment supplied on the skid shall be supplied by the successful bidder. Bidder shall

indicate connection points for sludge, DO and Hot water. Pipings up to these connection points will be on the charge of

the CEB. All equipment, such as pumps, blower fans, compressors and etc forming part of the incinerator lot shall take

their electrical supply from an electrical panel. The panel should  be  equipped  with  appropriate  circuit  breakers

and  contactors  for  each component and shall allow independent padlocking of the equipment by operators without

intervening from inside of the panel. All padlocking works shall be made from outside the electrical panel. The

Electrical panel shall take supply from an external 3 phase supply.

 

 

2.4  Electrical Panel

 

The panel nominal voltage shall be 415 Vac and its rated insulation voltage shall be 1000 Vac.

 

–      The main compartment shall be fed from an existing switchboard

 

 

The panel shall be of factory assembled, metal clad and draw-out type in design for outdoor application.

Castable outstanding high quality refractory mobile lining in addition to incinerator covering

E-2

The daily oil container of capacity 1,800 litres as well as dimension 1220x1220x1220mm pushed steel storage tank high shall be put 2.5 metres high over ended up flooring degree on a steel stand, highly secured on the ground and additionally the steel participants to be straightened. The day-to-day oil container shall have an oil level indication, ease of access manhole, washout, overflow, inlet together with outlets links as well as portal shutoffs.

The adjoining pipe of 50mm dimension between the two tank will surely be course ‘‘ C ‘black mild steel pipeline, complete with a 50mm diameter filter. The burner fuel supply pipeline from the container will surely be a 25mm size class ‘‘ C ‘black mild steel.

The adhering to will in addition be supplied.
– – home heating tap along the heating system supply pipe, 25mm size

The heating unit supply pipe will have 25mm thick fiber glass insulation as well as perform with scale 20SWG galvanized steel sheet.

The tenderer will give all the essential controls for appropriate safety and also acceptable working of the installation.

1.1.1 HEATING UNIT

The heater will appropriate for 35 sec redwood No. 1 range fuel oil. It will surely be durable in construction and construction and also be produced in celebrities iron or other perfect products complete with placement plates. It requires to be likewise demountable and quickly mountable for relaxation of upkeep and cleansing. The heating unit is going to have a suitable supply of oil which will quickly stir up along with melt in a safe way. Sufficient arrangement will definitely be supplied to prevent any sort of solid issue in the petroleum, or any sort of kind of concern that may separate out from the petroleum from damaging any elements or chocking of any sort of kind of orifices or shutoffs. The free filtering system place should definitely be sufficient to see to it that the filter does not require taking apart for cleaning up regularly than every year. The burner will have fire advice by photo-electric cell with simultaneous series control for automatic start up, running as well as shut-down of the burner.

The burner will have all the essential controls e.g.Solenoid shutoffs, ignition controls, photo electric cell gas safety and security and security controllers, low pressure fuel supply cut-off and so forth.

The heating unit will surely please BS 799: component 3 combined with 6 1981 or some various other applicable British standard.The burner is going to be as NU-WAY versions or equal and likewise approved.

1.1.2 REGULATES

The incinerator shall run in an automatic fashion with all the called for controllers. These controllers would be to include protection components such as fire failing device, pilot lights, incorporates, beginners, overload contactors, ON in addition to OFF switches for heating systems and also enthusiasts, burning chamber temperature level indicators for additionally 2nd as well as key chambers and so forth.

I) Electric ignition switch ‘‘ ON’ prior to the oil is supplied.
Iv) Favorable safety and security and security lock-out in instance of flame stopping working from whatever reason.
– – Totally wired controller board

The bulk oil storage tank will have an ability of 10,200 litres as well as be put at 0.5 m over ground on a company concrete cradle, total amount with the following:-.
Ii) Delayed go back to re-start readying to allow purging.
Iii) Re-start after short-lived electrical supply failing.

The incinerator will surely have chimney, castable premium refractory cellular lining in addition to heater shell, perforated blind for the major together with additional burning chambers and also air blood circulation system.

The heater shall also have the following:-.
–.
– Main as well as additional heating units as well as additionally fans.
V) Red signal light on control panel to indicate security and safety locked out.
Vi) Photo electric safety cell as fire stopping working tool.

The controllers will be put on appropriate control panel to be put in a position simple to assess as well as take care of from the charging side of the burner.

The controller board will definitely be made from anodized, 16SWG, light steel sheet.

Twin Chamber Incinerator

Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Nanjing Clover Medical Technology Co., Ltd., local in Nanjing city, China. CLOVER is manufacturer of medical product, waste incinerator and other environmental protection equipment. The market network across over the territory of China and more than 30 countries throughout the world. 
We, Nanjing Clover Medical Technology Co., Ltd., based at China mainland. We are manufacturer of environmental protection equipment and specialized in design, factories in china of biological waste incinerators, factory incinerator, factory waste burners 50 kg per hr, farm animal cremation equipment, manufacture and sell Waste Management System, including incinerator for Hospital, Veterinary Clinic, Laboratory, Farm, Community waste and Camp Waste, etc. Clover Medical supply incinerator, capacity from 10kgs per hour to 500kgs per hour. We also agent and sale burners, including Light Oil Burner, Heavy oil Burners, Gas Burner and Dual Fuel Burner Light Oil&Gas, etc.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Brûleur capable de prendre en charge entre 300 & & & & 500 kg équipé du système de lavage humide

Le chargement automatique ainsi que le remplissage d’une capacité de 10 à 12 lots par jour fonctionnant avec des méthodes de traitement du gaz ainsi que du gaz combustible doivent également respecter les normes européennes. Conditions. ils ont des déchets de base comme des cellules, des conteneurs en plastique, etc., des déchets provenant de camps de travail, à incinérer, ils ont besoin d’un brûleur de 50 kg / h
INCINÉRATEUR DE DÉCHETS MÉDICAUX.Notre établissement de santé produit 40 kg par jour à partir de tous les déchets
–– – – Capacité: 1000 kg / h
–– – – déchets de nature
––: déchets dangereux – – Autres besoins: Système de remplissage automatique des déchets ainsi que système de thérapie par aspiration.
1. Capacité: 100kgs par lot
2. Température
I. Chambre primaire 600-800
ii. Chambre secondaire 850-1500
3. Consommation par lot: 3,2 ressources humaines.
4. Prise de gaz: 7 litres par ensemble. Incinérateur avec une capacité de traitement entre 300 & & & & 500 kg équipé du système de lavage par voie humide. Réchauffeur complet d’une capacité de 500 kg / h avec un outil de lavage par voie humide. un 10-20Kg par heure de déchets résidentiels? Je voudrais savoir quelle est la capacité minimale du brûleur dans les circonstances où nous avons besoin de quelque chose de plus petit? Un brûleur à déchets de 500 tonnes métriques par jour, car je suis propriétaire d’une quantité massive de déchets mixtes / municipaux (4/5 millions tonnes) des cosmétiques suivants (52% naturel, 12% plastique, 16% papier, 6% métal, 4% verre et également 10% divers autres). Les codes UE des déchets sont les suivants: 20 03 01, 19 12 10 et également 19 12 12.
Parmi les aspects importants de la prise de décision du fournisseur éventuel, il y a la consommation d’énergie de la technique, indiquée soit par ressources humaines, soit quotidiennement et de même, j’apprécierais absolument que de telles informations puissent être rendues disponibles.

animal burner


The incinerator plant shall include a control board for its treatment. On the control panel we will have an aesthetic

display of the chamber temperature level levels. This aesthetic screen needs to maintain an eye and handle on the burner in addition to his performance.

Capacity of destruction in weight will be 60 Kg/h.

It need to be able to operate very little less than 10 hours/day

This burner need to have the capability to wreck all flammable wastes created by healthcare centers, personal facilities, lab,

institutes, and so forth.

Design Spec: Types A, B, C, D, in addition to E of medical waste

Supply, setup & & & & screening DUCTED SPLIT SYSTEMS at waste store with sufficient capability to keep the internal

temperature at 14 degrees Celsius in summer season periods in addition to cold weather


Установка для сжигания бытовых отходов

Базовая информация.

Номер модели: производитель установок для сжигания медицинских отходов
Экспортные рынки: глобальный

описание продукта

Компания Nanjing Clover Medical Technology Co., Ltd. является ведущим производителем мусоросжигательных установок в Китае. Мы – местный производитель и один из крупнейших экспортеров Китая. Техническое оборудование пиролитической установки для сжигания отходов является основной обработкой отходов во всем мире, для медицинских отходов, 50 вопросов о Филиппинах, размер печи для сжигания животных 500 кг, печь для сжигания 500 кг в час, печь для сжигания 50 кг, мусоросжигательная печь 50 кг / час, 6-8 тонн на горелка для мусора, сжигание животных, кремация домашних животных и другие твердые отходы. Емкость от 10кг / час. До 500 кг / час, до 6 тонн в день. В настоящее время мы поставляем различные серии в соответствии с требованиями местных клиентов и проектируем обновленную мусоросжигательную печь с использованием наших передовых технологий. Обновленные конструктивные особенности нашего ассортимента мусоросжигательных печей делают их одними из самых экономичных в мире.

Ключевая особенность:
* Все модели с двойной камерой сгорания.
* Дымоход / дымоход из нержавеющей стали, долгий срок службы. * по заказу
* Высокая температура, длительный срок службы инсинератора.
* Бесплатная или минимальная установка на месте.
* Высокая скорость сжигания, от 10 кг до 500 кг в час, до 6 тонн в день.
* Плоскость управления ПЛК. * по заказу
* Новый дизайн для кремации домашних животных.
* Один год гарантии на инсинератор и запасные части.

Предметы / Модель MSW2000 MSW3000 MSW4000 MSW5500
Скорость горения 150 кг / час. 200 кг / час. 300 кг / час. 500 кг / час.
Емкость подачи 400 кг 600 кг 800 кг 1100 кг
Вес оборудования 7600 кг 9500 кг 13000 кг 16500 кг
Картина
Первичная камера (литры) 2000 г. 3000 4000 5500
Вторичная камера (литры) 500 1200 1500 1500
Внешние размеры (см) 270x185x380 280x230x425 320x220x460 360x220x475
Внутренние размеры (см) 180x115x96 240x120x105 257x147x108 300x147x125
Масляный бак (литры) 300 500 500 500
Дверной проем (см) 59 х 81 90 х 110 108 х 128 108 х 128
Дымоход (M) 10 10 14 14
Тип дымохода Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь
Вторичная камера ДА ДА ДА ДА
Камера смешанного сгорания ДА ДА ДА ДА
Камера дымового фильтра ДА ДА ДА ДА
Горючее топливо Нефтяной газ Нефтяной газ Нефтяной газ Нефтяной газ
Время проживания 2.0 сек. 2.0 сек. 2.0 сек. 2.0 сек.
Контроль температуры ДА ДА ДА ДА

burning 150 kg of waste incinerator

In a bid to bring a partial relief from the mounting waste disposal issues, a new incinerator will begin functioning at the Kozhikode Medical College soon. Authorities say that the new incinerator will become operational by the first week of August.

The incinerator has been installed using the fund from the Hospital Development Society (HDS).

HDS member Saleem Madavoor told ‘City Express’ that the society has allotted `15 lakh towards the expenses that will be acquired for the installation works. Kerala Small Industries Development Corporation Limited(SIDCO), a state government undertaking has been entrusted with the works.

An official of the medical college said that an expert team, deputed by SIDCO, has visited the medical college to review the primary arrangements.

The work order has been given to SIDCO and an agreement was signed between the medical college authorities and SIDCO officials three months back.

The medical college official added that the works of the incinerator are completed and installation works will start within few days.  When the new incinerator begins operating, the waste disposal issues will be partially addressed. The incinerator which has a capacity of burning 150 kg of waste, will dispose of the residue generated from the medical college hospital.

Meanwhile, the medical college will continue to grapple with the waste being generated from the Institute of Maternal and Child Health (IMCH) and Super Specialty block as the incinerator for these blocks, which have been proposed at a cost of `63.5 lakh by the state government still remains on papers. If the incinerator becomes a reality around 5,000 kg of waste can be disposed everyday.

info from: http://www.newindianexpress.com/states/kerala/Waste-Woes-Medical-College-Gets-Partial-Relief/2015/07/17/article2924500.ece