Archive: January 19, 2022

Simply just how you can find practical incinerators for your regional website?

The heater with dual/double combustion chamber in addition to completely dry filter chamber, two gas burner from

Italy created, hot sale version for small range waste result, the ability is 30kgs per hr

in addition to likewise 50kgs per individual resources.

We are famous small scale incinerator manufacturer and brand, dispatch incinerator products 
and best services with lower price for customer all around the world.

Heater isn’t a cost-effective gadgets, generally the tiny range version’s cost around $5,000 usd per apparatus

in addition to massive range version’s price even more than $50,000 usd each. Before buy one system burner,

you need to make clear sticking to goods:

A, burn what?

you need to make clear sticking to goods:

A, burn what? Incinerator is a incineration tools, function is flame waste. What type of

waste you need to treatment? This according to the waste result daily or the waste quantity per

feed period, like animal dimension. Incinerator use oil or gas fuel, usually, gas fuel is less expensive than oil and the smoke

cleaner than petroleum gas version. Some neighborhood website do not have gas supply system.

As well as other technology items, such as electricity ( 220v, 380v), waste feed door type, burner framework, etc..

Tel: +86 -25 -8461 0201

WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

{
(adsbygoogle = window.adsbygoogle || []).push({});|}|

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

The heater with dual/double combustion chamber in addition to completely dry filter chamber, two gas burner from

Incinerator Combustion

Product Description

Waste Incinerator International Market Analytics 
Date. Jun. 10, 2012 
Download: Word format / PDF format 

Key Word: 
Small incinerators 
Medical waste incinerator 
Pet animal cremation incinerator 
Incinerator manufacturers 

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. 
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 
Incinerator fuel: Gas incinerator, oil incinerator 
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 
Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, 100kg capacity incinerator manufacturer in China, 10kg capacity incinerator, 10kgs per hour incinerator, 15 kg per hour incinerator cost, 150 kg dog, 150kg. Net, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc. 

So, why we still use incinerator? 
First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control. 
Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life. 

As above two reason but not only above, we still use incinerators. 

How you can find reasonable incinerator for your local site? 
Incinerator is not a cheap equipment, generally the small scale model’s price around $5, 000USD per unit and large scale model’s price more than $50, 000USD per unit. So, before purchase one unit incinerator, you have to make clear following items:
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment? 
B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size. 
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don’t have gas supply system. 
And other technology items, like power(220V, 380V), waste feed door type, incinerator structure, etc. 

After you clarify these, you can go to find a local or international manufacturers, asking prices, technical specifications and ultimately purchasing the right products. 

Wrote by Nicky

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

การติดตั้งและบำรุงรักษาตัวกรองประตูม้วนอัตโนมัติชนิดท่อลม

22 พฤษภาคม 2019 Industry News 190 views

ส่วนใหญ่ใช้ตัวกรองชัตเตอร์อัตโนมัติ ชนิดท่อในอาหาร ยา เครื่องมือที่มีความแม่นยำสูง และอุตสาหกรรมอื่น ๆ อุตสาหกรรมเหล่านี้มีความต้องการสูงสำหรับความสะอาด การติดตั้งและการขนส่งตัวกรองก่อนใช้งานมีข้อกำหนดการใช้งานบางประการ และการบำรุงรักษาในภายหลังก็จะต้องเป็นไปตามหลักวิทยาศาสตร์และสมเหตุสมผลด้วย
1. ในการขนย้าย ตัวกรองม้วนอัตโนมัติ ชนิดท่ออากาศ คุณต้องระมัดระวังและจัดการด้วยความระมัดระวัง ป้องกันความเสียหายที่เกิดกับภายในเครื่องกรองระหว่างกระบวนการ โดยเฉพาะแผ่นกรอง
2. ให้ความสนใจเป็นพิเศษกับปัญหาการกระแทก อย่าใช้แรงกระแทกมากเกินไปเพื่อหลีกเลี่ยงความเสียหาย
3. นอกจากนี้ยังมีข้อกำหนดบางประการสำหรับตัวจัดการที่ไม่มีของเหลวกัดกร่อนในมือ เพื่อไม่ให้เกิดการกัดกร่อนของอุปกรณ์
4. สถานที่จัดเก็บชั่วคราวควรมีอุณหภูมิค่อนข้างคงที่และความชื้นควรเป็นไปตามข้อกำหนดความชื้นสูงสุดของอุปกรณ์และควรมีการระบายอากาศของสถานที่จัดเก็บหลังจากขนส่งไปยังตำแหน่งการใช้อุปกรณ์ที่เกี่ยวข้องแล้วอุปกรณ์ควรได้รับการแก้ไข และติดตั้ง
5. ก่อนหน้านี้ เตรียมสถานที่ติดตั้ง อุณหภูมิ ความดัน ความชื้น ล้วนเป็นปัจจัยอ้างอิง เพราะหากสภาวะไม่เหมาะสม อายุการใช้งานของอุปกรณ์จะสั้นลง และปัญหาก็จะเกิดขึ้นระหว่างการใช้งานด้วย
6. หลีกเลี่ยงไม่ได้ที่จะต้องตรวจสอบสภาพพื้นฐานของอุปกรณ์ก่อนการติดตั้งเพื่อหลีกเลี่ยงความเสียหายหรือการเสียรูปจึงยากต่อการซ่อมแซมหลังการติดตั้งสิ่งสำคัญที่สุดที่ต้องใส่ใจระหว่างการติดตั้งคือการรับประกันประสิทธิภาพการปิดผนึก
7. ในเวลาเดียวกัน ทิศทางการไหลของอากาศของทางเข้าและทางออกควรจะเป็นวิทยาศาสตร์และสมเหตุสมผล หลังจากการติดตั้งเสร็จสิ้น บุคคลจากผู้ผลิตจะต้องรับผิดชอบในการแก้จุดบกพร่องของอุปกรณ์ หากไม่มีปัญหาหลังจากการดีบักก็สามารถ นำไปผลิต
8. ในการใช้งานในภายหลัง ความสะอาดของตัวกรองของตัวกรองม่านม้วนอัตโนมัติชนิดท่ออากาศ จะต้องได้รับการทดสอบอย่างสม่ำเสมอ และต้องเป็นไปตามมาตรฐานที่จำเป็นสำหรับการผลิต หากไม่เป็นไปตามมาตรฐานให้ค้นหาสาเหตุทันที
นอกจากนี้ การบำรุงรักษาและบำรุงรักษาในระยะหลังไม่ควรจะเหนื่อย บริษัทฯ จัดให้มีบุคลากรพิเศษในการบำรุงรักษาและบำรุงรักษาเป็นประจำโดยเฉพาะเมื่อไม่ได้ใช้งานตัวกรองม้วนอัตโนมัติแบบท่ออากาศเป็นเวลานานควรบำรุงรักษาและบำรุงรักษาเป็นประจำ เพื่อป้องกันความเสียหายต่อชิ้นส่วนอุปกรณ์ .

URL เนื้อหาเพิ่มเติม: www.ecolead.cn โทร: 025-57138032

محرقة PLC

معلومات أساسية.

مصادر السحب: معالجة النفايات الصلبة
طرق المعالجة: الاحتراق
أسواق التصدير: عالمية

معلومات إضافية.

العلامة التجارية: البرسيم

وصف المنتج

المحرقة عبارة عن معدات حرق ، نفايات حريق مباشر بواسطة وقود الغاز أو الوقود النفطي. كطوق مختلف ، يمكن تسمية المحرقة بالعديد من الكلمات على النحو التالي:

قدرة المعالجة: محرقة صغيرة الحجم ، محرقة واسعة النطاق وبانت حرق.

مواد النفايات: محرقة النفايات البلدية ، محرقة النفايات الطبية ، محرقة جثث الحيوانات ، محارق الجثث البشرية

وقود المحرقة: محرقة الغاز ، محرقة الزيت

تحويل النفايات إلى طاقة (WTE): محرقة WTE ، محرقة لا تستخدم WTE

الشركة المصنعة للمحرقة: الشركة المصنعة للمحرقة في الصين ، الشركة المصنعة للمحرقة في المملكة المتحدة ، الشركة المصنعة للمحرقة بالولايات المتحدة الأمريكية ، الشركة المصنعة للمحرقة في الهند.

الشركة المصنعة للمحرقة الشهيرة: Inciner8 (UK) ، Clover Incinerator (الصين) ، Pennram (الولايات المتحدة الأمريكية) ، Haat (الهند)

معدل الحرق: 5 كجم / ساعة ، 10 كجم / ساعة ، 15 كجم / ساعة ، 20 كجم / ساعة ، 30 كجم / ساعة ، 50 كجم / ساعة ، 100 كجم / ساعة ، 150 كجم / ساعة ، 300 كجم / ساعة ، 500 كجم / ساعة

PLC (وحدة تحكم منطقية قابلة للبرمجة) ، عملية ذكية وتلقائية. اضبط وقت الاحتراق وفقًا لمختلف مواد النفايات والمحارق في محارق النفايات الطبية في إيطاليا ، ومصنع محارق النفايات الطبية ، ومصنعي محارق النفايات الطبية في الصين ، ومصنعي محارق النفايات الطبية في الولايات المتحدة ، ووقف الاحتراق نفسه. اضبط معامل حماية درجة الحرارة ، إذا كانت درجة الحرارة شديدة الحرارة ، توقف المحرقة عن الاحتراق نفسه.

العناصر تخصيص
نموذج TS10 (PLC) / TS20 (PLC) / TS30 (PLC) / TS50 (PLC) / TS100 (PLC)
قائمة المنتجات الرئيسية غرفة احتراق مزدوجة
غرفة مرشح الدخان
حالة التحكم في وضع PLC
مدخنة ستانلس ستيل
موقد الزيت / الغاز في إيطاليا: 02 وحدة
خزان الزيت (إذا كان زيت الوقود)

اتصل الآن هاتف: + 86-25-8461 0201

Procedure Fire Brick Installation at Incinerator Oil and Gas

Basic Info.

Model NO.:price of burner incinerator
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can use in this equipment? 
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard 
A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity 
A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that’s mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. Incinerator medical for clinic, incinerator medical waste, incinerator news, incinerator of china manufature, incinerator pharma manufacturer waste, incinerator portable suppliers from china, According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. 
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing 
A: We supply all documents and incinerators easy to installation and operation. Customer can send people come to our factory to learn installation and operation. Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order. 

Q: Combustion Temperature 
A: The first combustion chamber: 800-1000 centi degree. 
The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode 
A: Default Control mode is common control case. PLC mode according to model and order. 

Q: Operation and maintenance costs 
A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinérateur de déchets municipaux

Informations de base.

Marchés d’exportation: mondiaux

Description du produit

Principales caractéristiques:
* Tous les modèles avec double chambre de combustion.
* Cheminée / cheminée en acier inoxydable, longue durée de vie. * selon commande
* Haute température, longue durée de vie de l’incinérateur.
* Installation gratuite ou minimale sur site.
* Taux de combustion élevé, de 10 kg à 500 kg par heure, jusqu’à 6 tonnes par jour.
* Plan de contrôle PLC. * selon commande
* Nouveau design pour les entreprises de crémation d’animaux de compagnie.
* Garantie d’un an sur l’incinérateur et les pièces en stock.
Champ d’application:
1. Hôpital et clinique: Déchets Iatriques, Déchets infectieux, pansements, biodéchets, médicaments.
2. Abattoir et hôpital pour animaux de compagnie et ferme: animaux morts, biodéchets.
3. Port et gare communautaires et maritimes: déchets solides municipaux, etc.
4. Laboratoires, sites éloignés, opérations de secours en cas de catastrophe, crémation d’animaux

Nanjing Clover Medical Technology Co., Ltd. est l’un des principaux fabricants d’incinérateurs de déchets en Chine. Nous sommes un fabricant local et l’un des plus grands exportateurs de Chine. L’équipement technique d’incinérateur pyrolytique est le principal traitement des déchets du monde entier, pour les déchets médicaux, l’incinération animale, l’incinérateur 100 kg par lot. Pdf, incinérateur. Filet, incinérateur / incinérateur de déchets portable, incinérateurs d’une capacité de 30 kg, incinérateurs pour hôpitaux de Chine, crémation pour animaux de compagnie et autres déchets solides. La capacité de 10 kg / h. Jusqu’à 500 kg / heure, jusqu’à 6 tonnes par jour. Actuellement, nous fournissons différentes séries pour les besoins des clients locaux et concevons un incinérateur mis à jour avec notre technologie de pointe. La conception mise à jour de notre gamme d’incinérateurs en fait l’un des plus rentables au monde.

Articles / modèle YD-200 YD-300 YD-500 YD-600
Taux de combustion (kg / heure) 200 kg / heure 300 kg / heure. 500 kg / heure 600 kg / heure
Capacité d’alimentation (kg) 400 kilogrammes 500 kilogrammes 800 kilogrammes 1100 kilogrammes
Poids de l’équipement 7600 kilogrammes 8300 kilogrammes 13000 kilogrammes 16500 kilogrammes
Chambre primaire (litres) 2000 2400 4000 5500
Chambre secondaire (litres) 500 1200 1500 1500
Dimensions extérieures (cm) 270 x 185 x 380 260 x 220 x 420 320 x 220 x 460 360 x 220 x 475
Dimensions internes (cm) 180 x 115 x 96 220 x 110 x 100 257 x 147 x 108 300 x 147 x 125
Réservoir d’huile (litres) 300 500 500 500
Ouverture de porte (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Cheminée (M) dix dix 14 14
Type de cheminée Acier inoxydable Acier inoxydable Acier inoxydable Acier inoxydable
Chambre secondaire OUI OUI OUI OUI
Chambre de mélange-combustion OUI OUI OUI OUI
Chambre de filtre à fumée OUI OUI OUI OUI
Combustible de combustion Gaz de pétrole Gaz de pétrole Gaz de pétrole Gaz de pétrole
Temps de résidence 2,0 sec. 2,0 sec. 2,0 sec. 2,0 sec.
Surveillance de la température OUI OUI OUI OUI

Incinerator (TS10 PLC)

Basic Info.

Model NO.:TS10 PLC
Pullution Sources:Solid Waste Processing
Processing Methods:Physics
Export Markets:Global

Additional Info.

Trademark:Clover
Packing:Wooden Carton
Standard:10 kg per hour
Origin:China
Production Capacity:1500units/Yesr

Product Description

Nanjing Clover Medical Technology Co., Ltd. is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., clover medical limited Saudi, clover medical limited yd-20c, clover medical. Net, clover-incinerator, clover+incinerator, up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 
Nanjing Clover Medical Technology Co., Ltd. 
Tel: +86-25-84610201 
Fax: +86-25-84610406 
Nanjing City, China

Items/Model TS10(PLC)
Burn Rate 10 kg/hour
Feed Capacity 20kg
Control Mode PLC
Combustion Chamber 100L
Internal Dimensions 50x50x40cm
Secondary Chamber 50L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) 5.4–12.6
Gas Consumption (m3/hour) 6.2–11.4
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 30x30cm
Chimney 3Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800degree–1000 degree
2nd. Chamber Temperature 1000degree-1200degree
Residency Time 2.0 Sec.
Gross Weight 1500kg
External Dimensions 140x90x120cm
 

The double air shower room purchased by Jiangsu Rentian Food Co., Ltd. was delivered smoothly

May 18, 2019 company news 325 views

Application of air shower room in food cold chain logistics and food preservation storage industry- Jiangsu Rentian Agricultural Technology Co., Ltd.

Air shower room, air shower room, blowing shower room, air shower door, dust bath room, blowing shower room…The design scheme can be assembled into various lengths of air shower rulers according to actual needs. 1400 standard technical parameters air shower room :
Project Single double blowing air shower room Double double blowing air shower room Multi person double blowing air shower Outdoor dimensions (W×D×H) (mm) 1400×1000×2180 1400×2000×2180 1400×3000×2180
Internal dimensions (W×D×H) (mm) 790×930×1910 790×1930×1910 790×2930×1910
Suitable number 1-2 people 2-4 people 3-6 people

Jiangsu Rentian Agricultural Technology Co., Ltd. (hereinafter referred to as “Rentian Technology”) was established in 2015. It is located in Nanjing, Jiangsu, which is known as the “Ancient Capital of the Six Dynasties”. Hereinafter referred to as “Fresh and Frozen Technology”) as the core value, with industrial bases, health food industrial parks, and healthcare industry investment as the core business, and is committed to applying the fresh and frozen technology to the industry and promoting the development of agricultural technology.

As an agricultural science and technology company, Ren Tian has formed strategic partnerships with many domestic professional scientific research institutions and universities such as the Chinese Academy of Agricultural Sciences, China Agricultural University, China Farmer University, Beijing Agricultural College, and established its own Agricultural Science Research Institute and Fresh Live micro-frozen fresh-keeping technology research and development center. The result of continuous investment in the field of scientific and technological innovation is that Rentian Technology has successfully invented the internationally leading and domestically original “fresh frozen technology” core technology, and has core competitiveness in the fields of food preservation technology and cold chain logistics.

In the food industry chain, the preservation of freshness is directly related to food safety. The patent “Fresh Frozen Technology” owned by Rentian Technology overcomes the problem of preservation and solves the problem of both deliciousness and long-term preservation of food. It has won the highest evaluation in the world. The principle of “Fresh Frozen Technology” is to prevent the cell membrane of the frozen food from being cracked, and the organism is in a slightly frozen state, thereby preserving the organism. Specifically, it uses high-tech biotechnology to simulate a controllable and rapid cooling natural environment in the fresh freezer. The ice crystallization state of the postgraduate object under low temperature conditions, the application of the newly invented fresh frozen liquid of pure natural ingredients, is Fresh fruits, vegetables and meat adopt an innovative freezing curve, which is directly frozen in the fresh freezing liquid, so that the temperature of the product reaches minus 7 degrees without freezing.

In this way, fresh and slightly frozen fruits, vegetables, aquatic products, and meat products can still maintain their fresh quality after long-term storage and transportation, which solves the problem of safe preservation in the circulation, processing, and sales of agricultural products. As the core technology of Rentian Technology, “Fresh Frozen Technology” has reached the current international leading level in the field of food preservation.

More content URL: www.ecolead.cn Tel: 025-57138032

Incinerator for Pharmacuticals Comapny

Product Description

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. 
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 
Incinerator fuel: Gas incinerator, oil incinerator 
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 
Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour 

Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, clover incineraters, clover medical China, clover medical net, clover-medical, clovermedical. Net, construction of an incinerator, cost for incineration for pets cost of running 100kg, 
Cremation equipment cost animal, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc. 

So, why we still use incinerator? 
First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control. 
Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life. 

As above two reason but not only above, we still use incinerators. 

How you can find reasonable incinerator for your local site? 
Incinerator is not a cheap equipment, generally the small scale model’s price around $5, 000USD per unit and large scale model’s price more than $50, 000USD per unit. So, before purchase one unit incinerator, you have to make clear following items:
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment? 
B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size. 
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don’t have gas supply system. 
And other technology items, like power(220V, 380V), waste feed door type, incinerator structure, etc. 

After you clarify these, you can go to find a local or international manufacturers, asking prices, technical specifications and ultimately purchasing the right products.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm