HICLOVER Needle Incinerators-Syringe and Destroyer-Needle Destroyer

1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ).
2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk.
3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again.
Medical Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube.
Model SYC19, Price: $110usd/set, MOQ: 5 sets.
EXW factory term(donot including shipping cost)
Purchase email:  [email protected]
Qustion1: If request 1-4 set only, how to do?
Answer: We will plus $50-$200usd fee per order.
Qustion2: If request more than 5 sets only, any discount?
Answer: We will  supply discount quotation accordingly.

Incinerator Items/Model HICLOVER TS5(PLC) HICLOVER TS10(PLC) HICLOVER TS20(PLC) HICLOVER TS30(PLC)
Burn Rate (Average) 5-10 kg/hour 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour
Feed Capacity(Average) 10kg/feeding 20kg/feeding 40kg/feeding 60kg/feeding
Control Mode PLC Automatic PLC Automatic PLC Automatic PLC Automatic
Combustion Chamber 52L 100L 210L 330L
Internal Dimensions 50x35x30cm 50x50x40cm 65x65x50cm 75x75x60cm
Secondary Chamber 26L 50L 110L 180L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 2P 220V 2P 220V 2P 220V 2P
Power 0.5Kw 0.5Kw 0.5Kw 0.5Kw
Burner Type Italy Brand Italy Brand Italy Brand Italy Brand
Oil Consumption (kg/hour) 4 6 8 12
Gas Consumption (m3/hour) 6.2-11.4 6.2-11.4 8-15.7 9.8–20
Temperature Monitor Yes Yes Yes Yes
Temperature Thermometer Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube
Temperature Protection Yes Yes Yes Yes
Automatic Cooling Yes Yes Yes Yes
Automatic False Alarm  Yes Yes Yes Yes
System Testing Model Yes Yes Yes Yes
Time Setting Yes Yes Yes Yes
Progress Display Bar LCD Display LCD Display LCD Display LCD Display
Oil Tank 200L 200L 200L 200L
Oil Tank Stand 190cm Height 190cm Height 190cm Height 190cm Height
Liquid level Display  Yes Yes Yes Yes
Feeding Door 20x20cm 30x30cm 45x40cm 55x50cm
Chimney 2Meter 3Meter 3Meter 5Meter
Chimney Type Stainless Steel 304  Stainless Steel 304  Stainless Steel 304  Stainless Steel 304 
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1000kg 1500kg 2200kg 3000kg
External Dimensions 120x80x110cm 140x90x120cm 160x110x130cm 175x120x140cm

Hospital Syringe and Destroyer-Needle Destroyer-Needle Incinerators

1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ).
2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk.
3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again.
Medical Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube.
Model SYC19, Price: $110usd/set, MOQ: 5 sets.
EXW factory term(donot including shipping cost)
Purchase email:  [email protected]
Qustion1: If request 1-4 set only, how to do?
Answer: We will plus $50-$200usd fee per order.
Qustion2: If request more than 5 sets only, any discount?
Answer: We will  supply discount quotation accordingly.

Incinerator Items/Model HICLOVER TS5(PLC) HICLOVER TS10(PLC) HICLOVER TS20(PLC) HICLOVER TS30(PLC)
Burn Rate (Average) 5-10 kg/hour 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour
Feed Capacity(Average) 10kg/feeding 20kg/feeding 40kg/feeding 60kg/feeding
Control Mode PLC Automatic PLC Automatic PLC Automatic PLC Automatic
Combustion Chamber 52L 100L 210L 330L
Internal Dimensions 50x35x30cm 50x50x40cm 65x65x50cm 75x75x60cm
Secondary Chamber 26L 50L 110L 180L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 2P 220V 2P 220V 2P 220V 2P
Power 0.5Kw 0.5Kw 0.5Kw 0.5Kw
Burner Type Italy Brand Italy Brand Italy Brand Italy Brand
Oil Consumption (kg/hour) 4 6 8 12
Gas Consumption (m3/hour) 6.2-11.4 6.2-11.4 8-15.7 9.8–20
Temperature Monitor Yes Yes Yes Yes
Temperature Thermometer Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube
Temperature Protection Yes Yes Yes Yes
Automatic Cooling Yes Yes Yes Yes
Automatic False Alarm  Yes Yes Yes Yes
System Testing Model Yes Yes Yes Yes
Time Setting Yes Yes Yes Yes
Progress Display Bar LCD Display LCD Display LCD Display LCD Display
Oil Tank 200L 200L 200L 200L
Oil Tank Stand 190cm Height 190cm Height 190cm Height 190cm Height
Liquid level Display  Yes Yes Yes Yes
Feeding Door 20x20cm 30x30cm 45x40cm 55x50cm
Chimney 2Meter 3Meter 3Meter 5Meter
Chimney Type Stainless Steel 304  Stainless Steel 304  Stainless Steel 304  Stainless Steel 304 
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1000kg 1500kg 2200kg 3000kg
External Dimensions 120x80x110cm 140x90x120cm 160x110x130cm 175x120x140cm

Medical Syringe and Destroyer-Needle Destroyer-Needle Incinerators

1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ).
2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk.
3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again.
Medical Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube.
Model SYC19, Price: $110usd/set, MOQ: 5 sets.
EXW factory term(donot including shipping cost)
Purchase email:  [email protected]
Qustion1: If request 1-4 set only, how to do?
Answer: We will plus $50-$200usd fee per order.
Qustion2: If request more than 5 sets only, any discount?
Answer: We will  supply discount quotation accordingly.

Incinerator Items/Model HICLOVER TS5(PLC) HICLOVER TS10(PLC) HICLOVER TS20(PLC) HICLOVER TS30(PLC)
Burn Rate (Average) 5-10 kg/hour 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour
Feed Capacity(Average) 10kg/feeding 20kg/feeding 40kg/feeding 60kg/feeding
Control Mode PLC Automatic PLC Automatic PLC Automatic PLC Automatic
Combustion Chamber 52L 100L 210L 330L
Internal Dimensions 50x35x30cm 50x50x40cm 65x65x50cm 75x75x60cm
Secondary Chamber 26L 50L 110L 180L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 2P 220V 2P 220V 2P 220V 2P
Power 0.5Kw 0.5Kw 0.5Kw 0.5Kw
Burner Type Italy Brand Italy Brand Italy Brand Italy Brand
Oil Consumption (kg/hour) 4 6 8 12
Gas Consumption (m3/hour) 6.2-11.4 6.2-11.4 8-15.7 9.8–20
Temperature Monitor Yes Yes Yes Yes
Temperature Thermometer Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube
Temperature Protection Yes Yes Yes Yes
Automatic Cooling Yes Yes Yes Yes
Automatic False Alarm  Yes Yes Yes Yes
System Testing Model Yes Yes Yes Yes
Time Setting Yes Yes Yes Yes
Progress Display Bar LCD Display LCD Display LCD Display LCD Display
Oil Tank 200L 200L 200L 200L
Oil Tank Stand 190cm Height 190cm Height 190cm Height 190cm Height
Liquid level Display  Yes Yes Yes Yes
Feeding Door 20x20cm 30x30cm 45x40cm 55x50cm
Chimney 2Meter 3Meter 3Meter 5Meter
Chimney Type Stainless Steel 304  Stainless Steel 304  Stainless Steel 304  Stainless Steel 304 
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1000kg 1500kg 2200kg 3000kg
External Dimensions 120x80x110cm 140x90x120cm 160x110x130cm 175x120x140cm

Syringe and DestroyerNeedle Destroyer Needle Incinerators

Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube.
Model SYC19, Price: $110usd/set, MOQ: 5 sets.
EXW factory term(donot including shipping cost)
Purchase email:  [email protected]
1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ).
2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk.
3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again.
Qustion1: If request 1-4 set only, how to do?
Answer: We will plus $50-$200usd fee per order.
Qustion2: If request more than 5 sets only, any discount?
Answer: We will  supply discount quotation accordingly.

Incinerator Items/Model HICLOVER TS5(PLC) HICLOVER TS10(PLC) HICLOVER TS20(PLC) HICLOVER TS30(PLC)
Burn Rate (Average) 5-10 kg/hour 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour
Feed Capacity(Average) 10kg/feeding 20kg/feeding 40kg/feeding 60kg/feeding
Control Mode PLC Automatic PLC Automatic PLC Automatic PLC Automatic
Combustion Chamber 52L 100L 210L 330L
Internal Dimensions 50x35x30cm 50x50x40cm 65x65x50cm 75x75x60cm
Secondary Chamber 26L 50L 110L 180L
Smoke Filter Chamber Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual
Voltage 220V 2P 220V 2P 220V 2P 220V 2P
Power 0.5Kw 0.5Kw 0.5Kw 0.5Kw
Burner Type Italy Brand Italy Brand Italy Brand Italy Brand
Oil Consumption (kg/hour) 4 6 8 12
Gas Consumption (m3/hour) 6.2-11.4 6.2-11.4 8-15.7 9.8–20
Temperature Monitor Yes Yes Yes Yes
Temperature Thermometer Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube Corundum Probe Tube
Temperature Protection Yes Yes Yes Yes
Automatic Cooling Yes Yes Yes Yes
Automatic False Alarm  Yes Yes Yes Yes
System Testing Model Yes Yes Yes Yes
Time Setting Yes Yes Yes Yes
Progress Display Bar LCD Display LCD Display LCD Display LCD Display
Oil Tank 200L 200L 200L 200L
Oil Tank Stand 190cm Height 190cm Height 190cm Height 190cm Height
Liquid level Display  Yes Yes Yes Yes
Feeding Door 20x20cm 30x30cm 45x40cm 55x50cm
Chimney 2Meter 3Meter 3Meter 5Meter
Chimney Type Stainless Steel 304  Stainless Steel 304  Stainless Steel 304  Stainless Steel 304 
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃ 1000℃-1300℃
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1000kg 1500kg 2200kg 3000kg
External Dimensions 120x80x110cm 140x90x120cm 160x110x130cm 175x120x140cm

EPA Proposes Interim Plan to Address Groundwater Contamination at the Welsbach/General Gas Mantle

 

Image

 

 

CONTACT: [email protected]
 

EPA Proposes Interim Plan to Address Groundwater Contamination at the Welsbach/General Gas Mantle Superfund Site in Gloucester City and Camden, N.J.

NEW YORK (August 24, 2021) – The U.S. Environmental Protection Agency (EPA) has proposed an interim plan to address groundwater contaminated with radium at the Welsbach/General Gas Mantle Superfund site located in Camden and Gloucester City, New Jersey. EPA is taking public comment on its plan and will host a virtual public meeting on September 8.

“This proposed plan continues EPA’s work to protect residents of Gloucester City and Camden from contamination associated with this site. Having already taken many actions to address the source of contamination, in this case we are focusing on contaminated groundwater,” said Acting Regional Administrator Walter Mugdan. “This is an interim plan that we propose to implement as we continue to assess the groundwater to see if we need to do more to address it in the long term. We feel this interim plan is the best approach and we look forward to continue to work closely with the impacted communities.”

EPA is proposing an interim cleanup plan, called a remedy, which will allow natural processes to break down radioactive elements in the groundwater into less harmful substances, coupled with putting into place institutional controls, such as restrictions on the use of the impacted groundwater, and conducting long-term monitoring of the groundwater to ensure that the breakdown of radioactive elements is happening as anticipated. EPA reached its decision based on information including results of the sampling of the groundwater between 2018 and 2020.

This Welsbach/General Gas Mantle Superfund site is divided into four phases of work called operable units, which are discrete pieces of the wider cleanup effort. This proposed plan addresses the fourth operable unit (OU4), which is groundwater. Under a cleanup plan for operable unit 1 (OU1) EPA is currently addressing radiologically impacted soil in the study area in Gloucester City, New Jersey. The interim remedy proposed today would be implemented during the OU1 cleanup of the radiologically contaminated soil. Once that soil, which is a source of groundwater contamination, is fully addressed the interim groundwater remedy will be reevaluated and EPA will establish a permanent groundwater cleanup plan.

EPA completed the cleanup work for OU2 in 2017, which included decontaminating building surfaces at the Armstrong Building (the last remaining building from Welsbach’s gas mantle operations) and disposing of the radiologically contaminated soil/waste to an approved off-site location. After careful study, EPA determined that no cleanup action was needed for OU3, which includes wetlands, surface water, and sediment as they posed no radiological threat to people or the environment.

EPA will continue to monitor the groundwater and will conduct a review of the site conditions at least every five years to ensure the effectiveness of the interim remedy. Work under today’s proposed plan is estimated to cost $460,000.

The EPA will hold a virtual public meeting to discuss its proposed interim plan on September 8, 2021, at 6:00 pm. To register for the public meeting, please visit https://welsbach-ggm.eventbrite.com.

Written comments on the proposed plan, postmarked no later than close of business September 24, 2021, can be mailed or emailed to Thomas Dobinson, Remedial Project Manager, U.S. Environmental Protection Agency, 290 Broadway – 19th Floor, New York, NY 10007, Email: [email protected]

For site background and to view the proposed interim plan, visit: https://www.epa.gov/superfund/welsbach-ggm

Follow EPA Region 2 on Twitter at http://twitter.com/eparegion2 and visit our Facebook page, http://facebook.com/eparegion2

21-052

EPA  @epa

Image

 

If you would rather not receive future communications from Environmental Protection Agency, let us know by clicking here.
Environmental Protection Agency, 290 Broadway, New York,, NY 10007-1866 United States

What is medical waste management



Item

Specification

Model

YD-20C

Main Product List

 

Primary Combustion Chamber

Secondary Combustion Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Incinerator Control Case

Chimney:5.0Meters *(upgrade to Stainless Steel, free Price )

Italy oil burner: 02 sets

Oil Tank: 100Liters

 

Optional:


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Mobile Trailer for Incinerator

Nanjing Clover Medical Technology Co.,Ltd.
bio medical waste management ppt 2020

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

The secondary chamber must comply with the following minimum criteria:
“• Heavy steel construction
• An excess air and high temperature operational mode.
• Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated.
• Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times. 
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm. 
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm. 
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints
• An electrically powered fan forced air supply, with the capacity for variation by the operator.
• One or more fuel burners designed to use diesel fuel type 2 (vehicle standard) equipped with a spark igniter.  
• A digital thermometer with connected to an electronic datalogger. The thermometer shall be located on the chamber wall away from the fuel burner.

For other animal incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

2021-02-21

 

2021-02-21



INCINERADOR DE RESIDUOS MÉDICOS (50 C 60 kg / h)

Incinerador de desechos médicos, 50 a 60 kg / h
Apoyo Proyecto de apoyo al sector de la salud
Punto de instalación (hospitales) Hospitales de Moi Voi, Makindu, Maragua, Eldama Ravine e Isiolo District
1. Descripción general
Suministro, entrega, instalación y puesta en servicio de un incinerador de residuos médicos apto para la eliminación de residuos médicos, generales y patológicos en un entorno seguro y limpio. La unidad constará de dos cámaras y funcionará con el principio de control de aire y temperatura. La unidad constará de un eliminador de partículas (depuradores) según lo estipulado en la normativa de gestión de residuos de 2006 (Aviso legal Nº 121 de 29 de septiembre de 2006). La Unidad será completamente automática y estará controlada por un sistema de control electrónico automático, excepto el sistema de carga que será manual. La unidad deberá ser capaz de incinerar entre 50 y 60 kg de desechos médicos sólidos por hora. Deberá estar construido de acero dulce o aluminizado revestido con material refractario.
Unidad principal
Solicitud Para incineración, general y patológica
Capacidad 50 C 60 kg / h velocidad de combustión
Tipo Tipo de dos cámaras de combustión; tipo de aire de combustión primaria y secundaria, controlada / forzada con una unidad de lavado de emisiones de gases de combustión
Tiempo de funcionamiento Mínimo 8 horas diarias
Temperatura de funcionamiento De 850 0C a 1200 0C, controlado automáticamente
Ceniza residual 5 a 10%
3.2 Cámara primaria
Construcción Construido de acero suave o aluminizado de alta resistencia O
equivalente igual y aprobado
Material de aislamiento Revestimiento de material refractario similar o igual al calcio
Combinación de silicato y cara caliente de mampostería de alta resistencia
Construcción interna Tipo de hogar fijo completo con rejillas, fondo cóncavo
y puerta de carga, revestida con material refractario
Puerta de carga Apto para carga manual de residuos y con suave
Estimado sello equivalente a sellos cerámicos con bisagras.
Cerradura de la puerta Automático, tipo eléctrico
Puerta de extracción de cenizas Provisto, para eliminar los restos de ceniza de fondo resultantes de la cámara primaria
Rejillas Previsto
Cargando Carga manual de residuos
Quemador primario Totalmente automático, con controles de combustible, temperatura y velocidad con sistema de encendido, detector de llama, ventilador de aire completo con características de seguridad, falla de llama, inyector de combustible diésel y montado en brida
Soplador Previsto. Para suministrar el exceso de aire de combustión a través del sistema de distribución con sistema de control de velocidad
Temperatura Salida mínima 850 0C
Puerto de observación Debe ser provisto de vidrio protector tipo
Construcción Construido de acero suave o aluminizado de alta resistencia o equivalente y homologado
Aislamiento Revestimiento de material refractario
Temperaturas de combustión Por encima de 850 0C, controlado electrónicamente
Residuos de gas o tiempo de retención > 2 segundos a un mínimo de 850 0C
Quemador secundario Provisto, a diésel, totalmente automático, con control de combustible, temperatura y velocidad, con sistema de encendido, detector de llama, ventilador de aire, completo con funciones de seguridad, fallo de llama Inyector de combustible a diésel. Brida montada
Eyector Suministrado, tipo Venturi, para enfriar los gases de combustión
Ventilador de aire de combustión Previsto para suministrar combustión y crear una deriva negativa y turbulencias.
Temperatura Máximo 1600 0C

소주 Tianfu 전자 재료

2019-05-22 실적 및 사례500 조회수

프로젝트 이름: Tianfu 전자 재료 정화 장비 생산 및 설치

프로젝트 소개: 클린 셰드, 윈드 샤워 룸, BFU 디자인, 생산 및 설치

착수 시기: 2012.9



  Suzhou Tianfu Electronic Materials Co., Ltd.는 쑤저우 공업 단지 현대 산업 광장에 위치하고 있으며 2010년에 설립된 한국의 100% 외국인 소유 기업입니다. 부품소재 전문기업으로 LCD, TV, 노트북 등 첨단소재의 개발, 생산, 가공을 주요 사업으로 영위하고 있습니다. Suzhou Tianfu Electronic Materials Co., Ltd.는 한국 본사에 소속되어 있으며, 본사는 2005년 7월에 설립되었습니다. 본사는 주로 기술 산업에서 사용되는 실리콘, 흑연, 폴리카보네이트, 폴리우레탄, 에틸렌은 내열, 절연, 전도성, 난연, EMI 차폐 제품을 제조 및 가공하는 주요 소재입니다.

추가 콘텐츠 URL: www.ecolead.cn Tel: 025-57138032

Equipments Incinerator Animals

Product Description

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Nanjing Clover Medical Technology Co., Ltd., Neighborhood in Nanjing city, China.

Msw Incinerator

Basic Info.

Export Markets:Global

Additional Info.

Trademark:nanjing clover medical
Origin:Nanjing

Product Description

It is being recently issued an ordinance by the Ministry of Environment to build incineration plants in the metropolitans which generate more than 10.000kg of medical waste per day. And this implementation is going to start in the beginning of the year 2014. 
Our aim is to build a Medical Waste Incineration Plant in one of the metropolitan cities in Turkey. We have been preparing for the tenders which are going to be held soon by the Metropolitan Municipality. 
We would like to cooperate with a supplier/contractor for building an incineration plant. Would you be able to advise if you devise incineration plants, if yes kindly advise in which part of the world you had worked (built incineration plants). 

Could you also please inform us regarding the following issues: 
– Is it possible to reach an incineration temperature of 1.100° C within the systems which you have been devising? (This is one of the standards for the incineration plants according to the regulations in Turkey). 
– Is it possible to generate electricity and how? 
– If it is possible to generate electricity within the system, what would be the kwh amount of electricity per ton of waste incinerated? 
– What is the period for building the plant? How long would it portable medical incinerators, portable pet cremation, portable trash incinerator, posco krakow incineration plant, post-animal incinerator fuel, take for building a plant and would it depend on the plant capacity as for 1.000kg/hr or 2.000kg/hr? 
– What is the water consumption per incinerated ton? And if there is electricity generation within the system, what would be the amount of water consumption per ton for generating 1 kwh of electricity? 
– Do the plants which you devise have gas cleaning and filtering systems? If already included or can be added, would you be able to advise your prices including the gas cleaning and filtering systems? 
– Would there be a change in the prices if electricity generation can be added to the system? If yes, would you please advise your prices according to this? 
We look forward to your cooperation. 
Thank you in advance for your quickest possible response. (Turkey) 

Que valor tiene un incinerador PARA quemar droga. 

– Que consumo de energí A tiene? ? ? 
– Cuanta contaminació N genera a la ATMó Sfera. 

Saludos y quedo atento. (Chile)

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm