Archive: July 29, 2021

diesel powered incinerator

diesel powered incinerator means the burner type is light oil with diesel oil fuel. the incinerator made by us have 2 combustion chamber, the primary with 1-2 burners,
and the secondary chamber with 1 burner.
 
all incinerator fixed with PLC Auto control system.
 

 
 
Nanjing Clover Medical Technology Co.,Ltd.

1.69Kw

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

addfield incinerator
hospital incinerator
adhushinak incinerators
de waste limited uganda

4.5.1 The goods, including all packaging and packing thereof, conform to the specifications of the Contract, are fit for the purposes for which such goods are ordinarily used and for any purposes expressly made known in writing in the Contract, and shall be of even quality, free from faults and defects in design, material, manufacturer and workmanship;
4.5.2 If the Contractor is not the original manufacturer of the goods, the Contractor shall provide UNOPS with the benefit of all manufacturers’ warranties in addition to any other warranties required to be provided under the Contract;
4.5.3 The goods are of the quality, quantity and description required by the Contract, including when subjected to conditions prevailing in the place of final destination;
The goods are free from any right of claim by any third-party, including claims of infringement of any 4.5.4intellectual property rights, including, but not limited to, patents, copyright and trade secrets;
4.5.5 The goods are new and unused;
4.5.6 All warranties will remain fully valid following any delivery of the goods and for a period of not less than one (1) year following acceptance of the goods by UNOPS in accordance with the Contract;
4.5.7 During any period in which the Contractor’s warranties are effective, upon notice by UNOPS that the goods do not conform to the requirements of the Contract, the Contractor shall promptly and at its own expense correct such non-conformities or, in case of its inability to do so, replace the defective goods with goods of the same or better quality or, at its own cost, remove the defective goods and fully reimburse UNOPS for the purchase price paid for the defective goods; and,
4.5.8 The Contractor shall remain responsive to the needs of UNOPS for any services that may be required in connection with any of the Contractor’s warranties under the Contract.

General waste incinerator Dual chamber – Small
General requirements a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components
b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions
d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated
e. achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%,
g. include clearly readable system operation panels;
h. include an operator’s manual (in English and French); 
i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding
j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated
k. can accommodate large variations in waste composition and calorific value
l. allow for batch loading
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%,
o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank), 
“r.proposals shall include the fuel consumption at the rated capacity
be CE Certified, meet relevant British, EU or American Standards, or equivalent.

 
 
 
 
 
 

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

 
Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected]       
Email:    [email protected]    

diesel powered incinerator

diesel powered incinerator means the burner type is light oil with diesel oil fuel. the incinerator made by us have 2 combustion chamber, the primary with 1-2 burners,
and the secondary chamber with 1 burner.
 
all incinerator fixed with PLC Auto control system.
 

 
 
Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

addfield incinerator
hospital incinerator
adhushinak incinerators
de waste limited uganda

4.5.1 The goods, including all packaging and packing thereof, conform to the specifications of the Contract, are fit for the purposes for which such goods are ordinarily used and for any purposes expressly made known in writing in the Contract, and shall be of even quality, free from faults and defects in design, material, manufacturer and workmanship;
4.5.2 If the Contractor is not the original manufacturer of the goods, the Contractor shall provide UNOPS with the benefit of all manufacturers’ warranties in addition to any other warranties required to be provided under the Contract;
4.5.3 The goods are of the quality, quantity and description required by the Contract, including when subjected to conditions prevailing in the place of final destination;
The goods are free from any right of claim by any third-party, including claims of infringement of any 4.5.4intellectual property rights, including, but not limited to, patents, copyright and trade secrets;
4.5.5 The goods are new and unused;
4.5.6 All warranties will remain fully valid following any delivery of the goods and for a period of not less than one (1) year following acceptance of the goods by UNOPS in accordance with the Contract;
4.5.7 During any period in which the Contractor’s warranties are effective, upon notice by UNOPS that the goods do not conform to the requirements of the Contract, the Contractor shall promptly and at its own expense correct such non-conformities or, in case of its inability to do so, replace the defective goods with goods of the same or better quality or, at its own cost, remove the defective goods and fully reimburse UNOPS for the purchase price paid for the defective goods; and,
4.5.8 The Contractor shall remain responsive to the needs of UNOPS for any services that may be required in connection with any of the Contractor’s warranties under the Contract.

General waste incinerator Dual chamber – Small
General requirements a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components
b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions
d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated
e. achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%,
g. include clearly readable system operation panels;
h. include an operator’s manual (in English and French); 
i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding
j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated
k. can accommodate large variations in waste composition and calorific value
l. allow for batch loading
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%,
o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank), 
“r.proposals shall include the fuel consumption at the rated capacity
be CE Certified, meet relevant British, EU or American Standards, or equivalent.

 
 
 
 
 
 

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

 
Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected]       
Email:    [email protected]    

incinerator suppliers in kenya

we supply incinerator for Kenya, with IDF SGS certification. the HS code of incinerator is 84178050. if you are looking for incinerator suppliers in kenya.
please contact with us. we supply 10kgs per hour to 1000kgs per hour waste incinerators, with or without wet scrubber system. the burner is oil or gas type.
We service and maintain our incinerators and provide consultancy services to Consulting Engineers, Mines, Abattoirs and Hospitals, 
giving full details on the incinerator required and the price.  

1. General waste incinerators for sale in Kenya.
2. Pet Cremation incinerators supply in Kenya
3. Bio-Medical Incinerators in Kenya
4. Animal cremation incinerators for sale in Kenya

 

 
 
Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

 
 
 

incenerator cp30 30kg h manufacturers
incinerator wikipedia
inciner8 medical incinerator
quality control in autoclaving and incineration of specimen disposal
design of an incenerator
medical incinerators
chemical disposal companies in uae

The secondary chamber must comply with the following minimum criteria:
“• Heavy steel construction
• An excess air and high temperature operational mode.
• Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated.
• Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times. 
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm. 
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm. 
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints

Size and efficiency The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections
The forecasted feedstock loads, and daily loading rates are generally summarized as
• Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities.   The wastes will consist of 100% biomedical wastes
• Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size.
• Operation on a daytime shift basis, 5 days per week.
• An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required.  The automated burn completion and cool down cycle will take place overnight.
• The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall be capable of 
using electricity as the primary power source
• Also consider provision for meeting international emission standards.
Able to handle an average waste production of 200kg/day
“• Minimum load capacity: 40 kg
• Maximum load capacity: 60 kg
• Nominal burning rate: 25-50 kg/hr (= 200 – 400kg range per 8hour day)

 
 
 

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

 
Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected]       
Email:    [email protected]    

incinerator suppliers in kenya

we supply incinerator for Kenya, with IDF SGS certification. the HS code of incinerator is 84178050. if you are looking for incinerator suppliers in kenya.
please contact with us. we supply 10kgs per hour to 1000kgs per hour waste incinerators, with or without wet scrubber system. the burner is oil or gas type.
We service and maintain our incinerators and provide consultancy services to Consulting Engineers, Mines, Abattoirs and Hospitals, 
giving full details on the incinerator required and the price.  

1. General waste incinerators for sale in Kenya.
2. Pet Cremation incinerators supply in Kenya
3. Bio-Medical Incinerators in Kenya
4. Animal cremation incinerators for sale in Kenya

 

 
 
Nanjing Clover Medical Technology Co.,Ltd.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10-20 kg/hour 20-30 kg/hour 30-50 kg/hour 50-100 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100-150 kg/hour 150-200 kg/hour 300-400 kg/hour 500-600 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

 
 
 

incenerator cp30 30kg h manufacturers
incinerator wikipedia
inciner8 medical incinerator
quality control in autoclaving and incineration of specimen disposal
design of an incenerator
medical incinerators
chemical disposal companies in uae

The secondary chamber must comply with the following minimum criteria:
“• Heavy steel construction
• An excess air and high temperature operational mode.
• Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated.
• Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times. 
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm. 
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm. 
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints

Size and efficiency The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections
The forecasted feedstock loads, and daily loading rates are generally summarized as
• Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities.   The wastes will consist of 100% biomedical wastes
• Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size.
• Operation on a daytime shift basis, 5 days per week.
• An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required.  The automated burn completion and cool down cycle will take place overnight.
• The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall be capable of 
using electricity as the primary power source
• Also consider provision for meeting international emission standards.
Able to handle an average waste production of 200kg/day
“• Minimum load capacity: 40 kg
• Maximum load capacity: 60 kg
• Nominal burning rate: 25-50 kg/hr (= 200 – 400kg range per 8hour day)

 
 
 

HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)

 
Mobile: +86-138139 31455(WhatsApp)

Website: www.hiclover.com 
Email:     [email protected]       
Email:    [email protected]    

Google快讯 – medical waste

Google
medical waste

实时更新 2021年7月29日
新闻

The Medical Waste Management market is extensive, with many regional and international players. The important market leaders follow numerous …

Facebook Twitter 标记为不相关

… pressure on production capacity, he said, adding that the inhalation method also obviates concerns about medical waste such as syringe needles.

Facebook Twitter 标记为不相关

查看更多结果 | 修改此快讯
您收到此电子邮件是因为您订阅了Google快讯

RSS 以RSS Feed的形式接收此快讯

发送反馈

Google快讯 – medical waste

Google
medical waste

实时更新 2021年7月29日
新闻

He has also urged to read all medical waste management instruments and ensure they run well,” the minister informed at an online press conference …

Facebook Twitter 标记为不相关

查看更多结果 | 修改此快讯
您收到此电子邮件是因为您订阅了Google快讯

RSS 以RSS Feed的形式接收此快讯

发送反馈

Google快讯 – medical waste

Google
medical waste

实时更新 2021年7月29日
新闻

FILE- A health care worker fills a syringe with the Pfizer COVID-19 vaccine, Thursday, July 22, 2021, at the American Museum of Natural History in New …

Facebook Twitter 标记为不相关

查看更多结果 | 修改此快讯
您收到此电子邮件是因为您订阅了Google快讯

RSS 以RSS Feed的形式接收此快讯

发送反馈

Incinerator Operation

Product Description

Nanjing Clover Medical Technology Co., Ltd..

Key Features: 

Product List
Items Specification
YDC Model YD-10C / YD-20C / YD-30C / YD-50C
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

* All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life.  * High fever, long life of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 600kgs per hour, up to 10ton daily.  * PLC Control Plane for Intelligent operation.  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock.

Hubei Daye Hanlong Automobile Painting Workshop에서 자동 롤러 셔터 필터 29 세트 계약 체결

2019-05-18 기업 뉴스229 조회수

여러 차례의 톱톱 협상과 제품 기술 확인을 거쳐 당사의 최근 판매 실적은 성공적이었고 우리는 Daye Hanlong Automotive Coating Workshop에서 한 번에 모든 롤러 셔터 필터에 대한 판매 계약을 체결했습니다. 현장 조사 권장 사항에 따라 설치 회사의 보관 및 설치 압력을 완화하기 위해 롤러 셔터 필터 배치를 배치로 현장에 배포할 예정입니다. 신선한 공기 통로의 깊이 치수의 좁은 설계로 인해 우리 기술자는 필터 설치 방법이 매립형 설치로 현장 공간을 최대한 절약하고 공식 작동 후 필터 재료 교체를 용이하게 한다고 제안합니다. 미래.

Hubei Daye Hanlong Automobile Co., Ltd.는 후베이성 Daye 시에 본사를 두고 있는 새로운 에너지 자동차 부품 제조업체입니다. 신에너지 자동차 설계, 개발, 제조, 판매 및 애프터 서비스를 통합하는 현대 국제 기업이며 자동차 엔진 제품, 예비 부품 지원 시스템 제품 및 자동차 유지 보수 전문 제조 업체이기도 합니다. 이 회사의 등록 자본금은 10억 위안이고 공장 면적은 1,000무입니다. Hanlong의 자동차 산업은 자동차, SUV, 순수 전기 자동차 및 하이브리드 동력을 포함한 4가지 주요 제품 시리즈를 포함합니다.총 프로젝트 투자는 거의 100억 위안입니다.1단계는 자동차 부품 및 장비 생산에 60억 위안을 투자했습니다.4 주요 공정은 스탬핑, 용접, 도장 및 최종 조립과 관련된 프로젝트의 건설 및 운영입니다. 2단계에서는 자동차 엔진과 같은 핵심 프로젝트의 건설 및 운영에 30억 위안을 투자했습니다.

추가 콘텐츠 URL: www.ecolead.cn Tel: 025-57138032

Cần chú ý những gì trong quá trình vận hành phòng tắm máy lạnh

Ngày 22 tháng 5 năm 2019 Tin tức ngành 199 lượt xem

Ở nhiều phân xưởng, để đảm bảo vệ sinh sạch sẽ của phân xưởng, một số phân xưởng sẽ lắp đặt bồn tắm không khí hoặc vòi hoa sen khí ở gần cửa phân xưởng để đảm bảo mỗi công nhân khi vào xưởng sẽ không mang theo bụi bẩn. Nhưng trong quá trình vận hành phòng tắm khí bụi cần lưu ý những vấn đề gì? Sau đây sẽ giới thiệu cho bạn:

Cửa ra vào không thể mở đồng thời, nếu có gió thổi ra, trước khi dừng phải ngăn không cho mở cửa bên cạnh bể tắm bụi. Khi vào phòng tắm bụi phải vào theo sức chứa tối đa của phòng tắm bụi, khi ra không được quá 10 người.

Trong phòng xông khí cần đứng theo vị trí quy định, khi tắm khí cũng cần xoay người, vỗ nhẹ cơ thể không bị chìm, để bụi bay ra tốt hơn. Cần cho chân đạp nhiều lần vào đệm bàn đạp, điều này cũng rất có lợi cho việc loại bỏ bụi và vật lạ bám trên đế. Mỗi công nhân khi vào xưởng làm việc cần lau sạch bụi trên người trong phòng hút bụi không khí để không mang bụi bên ngoài vào xưởng làm ô nhiễm môi trường trong xưởng không có lợi cho quá trình làm việc. xưởng. Hãy đến làm việc.

Trước khi công nhân vào xưởng, quần áo không dính bụi không được chạm vào tường, sàn và những nơi khác. Việc chạm vào lỗ thoát khí lại càng khó hơn, trong quá trình lắp đặt phải xác nhận thường xuyên và cũng cần ghi lại xem vị trí của lỗ thoát khí đã chính xác hay chưa. Đối với bộ lọc của cửa gió hồi, tốt nhất nên kiểm soát tần suất thay thế là một mùa / lần. Một khi bị hỏng hoặc bẩn, nó cần phải được thay thế ngay lập tức. Đồng thời khi thay thế cần báo cho nhà máy để xử lý và ghi vào bảng kiểm tra phòng tắm bụi.

Có vẻ như khi vận hành air bath phòng bụi quả thực có rất nhiều điểm cần phải chú ý trong quá trình vận hành này, nếu không chú ý thì trong quá trình sử dụng có thể xảy ra một số sự cố. Việc sử dụng đúng cách phòng tắm chứa bụi sẽ có tác động rất tiêu cực.

URL nội dung khác: www.ecolead.cn Tel: 025-57138032