Melt blown Production Line 400mm and 1600mm and ES Fiber Production Line and N95 Mask Machine and Disposable Mask Machine

1. N95 and Disposable Mask Machine

 

2. 400mm and 1600mm Melt blown Production Line

3. ES Fiber Production Line

 

 

 

N95 Face Mask Machine Production Line

Melt blown Production Line

 

A.)Optional Capacity: 1600mm

Efficiency: 95-97%

FOB Term Price: USD per set

Price Valid: 5days.

Ave.60 Days ready for shipping.

In stock Price: USD per set

 

 

B.)Optional Capacity: 400mm

Efficiency: 40-50% .

FOB Term Price: USD per set

Price Valid: 5days.

Ave.20 Days ready for shipping.

Payment: TT 70% In advance, TT 30% before leave factory

Shipping: 1*20′ container per set, Ave. 2000Kgs.

 

Main Parts: Extruder, mold, winder, oven, ultrasonic

Daily Capacity100-150Kgs/24Hours

Screw extruder100-150Kgs

Motor power: 15KW frequency conversion speed regulation
Reducer speed ratio: 1:10 or 1:16
Screw length to diameter ratio: 30: 1
Screw diameter: 50mm
Winding machine diameter:
630mm
Winding machine drive motor power: 0.55kw
Speed ratio of winder drive reducer (if any): 1:71
Air heater power: 15kw
Power of vacuum calciner: 12kw
The size of vacuum calciner: 500 × 300 × 200
Ultrasonic power: 1800, frequency 28kHZ
Ultrasonic sink size: 800 × 300 × 250

 

 



HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-20

Pyrolytic Twin Chamber Incinerator Small Size : Burning Rate : 30-45 kg/hr ; Optimum Tons Ability : 400 kg



Items/Model

TS50( PLC)

Image

Principle

Strong Waste Incineration

Burn Price

30-45 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Heater)

Burning Chamber

560L

Inner Measurements

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Establishing

Manual

Voltage

220V

Oil Consumption (kg/hour)

Regular 13.3

Gas Intake (m3/hour)

***

Temperature Level Display

Digital Show

Temperature Level Degree Protection

Yes

Oil Storage Tank

800L

Feed Door

70x55cm

Chimney

5Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Level Degree

800 ℃– – -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

Exterior Measurements

230x130x155cm

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



Device Measurement : Burning Rate : 60-80 kg/hr Pyrolytic Double Chamber Burner



Items/Model

TS100( PLC)

Image

Concept

Waste Incineration Treatment

Shed Rate

60-80 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

1200L

Inside Measurements

120x100x100cm

Second Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Establishing

Manual

Voltage

220V

Oil Usage (kg/hour)

Common 20.4

Gas Consumption (m3/hour)

***

Temperature Level Monitor

Digital Existing

Temperature Level Degree Defense

Yes

Oil Container

1100L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃– – -1000 ℃

second. Chamber Temperature Level Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Outside Measurements

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



Plus Size Burning Rate : 150-200 kg/hr Strong Waste Devices Main as well as 2nd Combustion Chamber Burner



Items/Model

TS500( PLC)

Photo

Principle

Waste Incineration Therapy

Melt Rate

150-200 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Heater)

Combustion Chamber

2700L

Inside Dimensions

190x120x120cm

Second Chamber

1300L

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

220V

Oil Intake (kg/hour)

Common 28

Gas Use (m3/hour)

***

Temperature Show

Digital Show

Temperature Level Safety And Security

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st.

Gross Weight

15000kg

Outdoors Dimensions

400x210x300cm( without chimney)

2020-03-21

400x210x300cm( without chimney)

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



china incinerator manufacturer and exporter

Primary Combustion Chamber
Waste Charging Door: Provided with refractory lining with sealing gaskets
Ash Removed Door: Provided with refractory lining with sealing gaskets
Outer Body MOC: Mild Steel, 5mm
Primary Chamber: Stainless Steel
Operating Temperature :800. ± 50◦C
Insulation: Insulation Brick
Heating Elements Type: Kanthal Al Grade
Power Consumption: 75 KW ( Initial Load )
Electrical Supply :3 Phase 440 Volt
Control Panel
MOC: Mild Steel Power Coated
No. of Temp: Controllers : 2 Nos
Details: The Control Panel will be provided with contract as relays , switches , indicators etc . Operative on 3 phase.
I.D.Fan
Type: Centrifugal Type
MOC: Mild Steel
Capacity:2 HP/3Phase
Make of Motor: Kirloskar /Havells/Crompton
Combustion Air Fan
Type: Centrifugal Type
Capacity: 1HP/3Phase
Make of Motor: Kirloskar /Havells/Crompton

30kgs rate 60kgs feed oil and gas burner small waste incinerator

30kgs rate 60kgs feed oil and gas burner small waste incinerator for Afghanistan

Machine Working mode

Oil or Gas + Power

Voltage

220V

Oil consumption (lit/hour)

Average 13.3lit/hour/chamber

Gas consumption (NG) (m3/hour)

16.0 (m3/hour) (NG)

Gas consumption (LPG) (m3/hour)

11.7 (m3/hour) (LPG)

Burning rate

Average 30kg/hour

Feed mode

Manual

Primary Combustion chamber

360 Liters

Secondary Combustion chamber

200 Liters

Combustion Chamber Material

Refractory Concrete Cement+firebrick

Internal dimensions

Yes (Primary chamber)

External dimensions

210x120x210cm(without chimney)

Door opening

48X60 cm

Fuel Type

Diesel Oil/ Natural Gas /LPG

Burner

Original

Chimney length

13.0 Meters

Smoke filter chamber

Yes

Temperature monitor

Two figure Digital Display

Temperature protection

Yes

Oil tank

200L

Burning Efficiency

>98%

Chimney type

Stainless steel

1st. chamber temperature

800c1000c

2nd.chamber temperature

1000c1200c

Residency time

2.0 sec.

Gross weight

4000kg

Electrical Plastic and glasses Shredder

Yes

Scrubber

Yes

Warranty Period

1.year

Primary combustion chamber

Yes

Secondary combustion chamber

Yes

Incinerator control case

S. steel

Incinerator chimney

Original

Fuel Burner

Yes

Oil Tank capacity

Yes

Oil Stand support

Yes

Dry Smoke Filter Chamber

Yes

Air Fan

Yes

Total waste incineration capacity/time

Minimum 60KG

for Ministry of Public Health, Kabul, Afghanistan

animal incinerator for poultry usage 
burning rate around 150 kg/hr 
load capacity around 350 kg .
Municipal waste incinerator for waste production rate of 50 ton/day
Medical waste incinerator for waste production rate of 200 kg/day
Medical waste incinerator for waste production rate of 500 kg/day
Medium Unit – to handle an average waste production of 500 kg/day and meet the capacity
Automatic PLC controller incinerator plant with Dual heat burners and dual chamber.
Burning capacity up to 30 Kg per hour.
Water showering cyclone air cleaner 
Stain less steel 304 grade sheet for water scrub chamber 
Time up to 250 mints.
Fully automatic electric control circuit with timers
Primary temperature up to 850 deg C
Secondary temperature up to 1100 deg C
Manual/automatic loading /unloading
Automatic start at power fail during process 
Fast temperature rise control automatic detects fast burning materials and save burner fuel consumption by turn off /on burner automatically.
Suitable for waste of hospitals
Number of burner   2 Nos
Voltage  440 V 50 Hz
Operational enjoinment          5 C 60 C Humidity 10 C 90%
Fuel type               Natural gas Number of chamber      02 Nos 

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-30

Mobile Cremation Instruments



Layout

CA-200

Picture

Burning Rate

Ordinary 100 kgs/hour

Key Burning Chamber

2000 Liters

Extra Burning Smokeshaft

Yes

Feed Setting

Guidebook

Voltage

220V

Power

3.0 Kw

Fuel Kind

Diesel Oil

Heater

Italy Original

Oil Use (Diesel Oil)

Normal 53 kg/hour

Inside Dimensions

230 x 100 x 90cm (key chamber)

External Dimensions

290 x 200 x 170cm (trick chamber)

Temperature Screen

Yes

Oil Container Ability( if oil gas)

500 Liters

Door Opening

90 x 90cm

Smokeshaft Size

5.0 Meters

Smokeshaft Type

Stainless-steel

Gadgets Gross Weight

9000 kgs( with container)

Procedure Technical Specs

Paimary Chamber Temperature Level

800 ℃–– – – 1000 ℃

2nd Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Performance

> 98%

Waste Lower Calorific Power

3000Kcal


Mobile crematorium 
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22



Burner for medical center waste monitoring



Heater for health care facility waste surveillance with the adhering to attributes:

– – In high temperatures( pyrolytic burner 2 chambers with temperatures varying from 950 º C to 1320 º C;

– – Capability to damage of 400 to 600kg per hr;

– – Effective in ruining germs;

– – Drain ash;

– Drain needle as well as glass crusher;

– – Patio with faucet water for hand cleaning and decontamination;

– – Observe the trouble of ecological high quality requirements, discharges proficient in addition to plan on the concern of waste; place big incinerator to among the largest veterinary university hospital in KSA so if you will certainly support us with one system (big incinerator) and also ecological with onsite training, the ability for the tool is 2000 Kg for cattle, equines as well as additionally farm animals in addition ideal to all animal waste kinds, we require it diesel fired. OES-Industrial MultiWaste Burner System (Solid/Liquid)

Level of the Job:
Style, setup along with appointing of multi hazardous waste burner.
Ability: 315 KG/HOUR STRONG WASTE/ OR 200 LITRES/HOUR FLUID WASTE (with dual chamber system).
1st chamber-870 Deg.C – – – – 900 Deg.C. Second chamber-1000 deg.C – 1200 Deg.C

Resources Of The Wastes.
The following types of wastes can be taken care of by using burner.
a). biography medical waste/pharmaceutical waste.
b). solid chemical waste/textile markets waste.
c). liquid chemical waste.
d). dyes in addition to intermediate waste.
e). all-natural chemical waste.
f). fluid ink waste/acidic deposit.
g). insecticides/herbicides/pesticides.
h). fungicide waste.
i). ethanolamine.
j). amino ethanol.
k). mono ethanolamine.
l). ETA, MEA waste.
m). wastes after treatment of chemicals in etp plant.
n). combined alcohol waste water.
o). alcoholic waste.
p). farming liquid chemical waste.
q). sludge mix fluid.
r). slurry/adhesive/grease/ powder coating wastes.
s). semi strong fluid chemical waste.
t). mass completely dry chemical waste.
u). pharma chemical wastes.
v). solvent chemicals/paint wastes/used glass grains.
w). used tires.
x). made use of cotton fabrics.
y). contaminated plastics/resin wastes.
Series of Job:.
Blaze all sorts of liquid/solid hazardous/chemical/non contaminateds products avaliable in the markets with proper scrubbing up system with typical emission rates.
The twin stage incinerator aids to burn the waste in 2 phases, initially at a tool temperature level of 870- 900 Deg C and likewise the 2nd stage at 1200 deg C.
Producing ash as well as Aeriform fumes which are treated with cyclone type wet scrubber in addition to caustic scrubber to produce air with contaminants in the enabled variety as well as Non dangerous ash mostly not natural salts.

Incinerator utilities.
Heater should have adhering to demands:.
Metallic seal framework with ceramic insulation to stay free from cozy radiation and additionally regulate radiant temperature degree.
Advanced gas treatment system to avoid discharge of dangerous gases (massaging system).
Reduced consumption high performance compact computerized burning system.
Low operating as well as maintenance rates.
Fully automatic and also very easy to operate control panel.
Afterburner Preheat.
Thick refractory concrete lining ranked at 1600 C.
Solid Hearth to make it possible for optimal Fatigue.
Large Leading opening cover for simple loading.
Wide door for ash removal.
Optional Stainless-steel Situation.
Warmth healing choice



Medical Center Waste Monitoring



Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description        Minimum Requirements
Design standard    Multiple chamber incinerator to the design of EPA  standards, Air pollution control
Description of the Chimney    Top mounted, self supporting
Incinerator performance    150kg/hr
Refuse     Hospital waste and carcasses
Recommended Temperatures    Minimum 1000⁰C
Dimensions:
Length
Width
Height
Extra width for burners    At least 3000mm
Loading door opening    Minimum 700mm x 600mm
Hearth area    5.00square meters
Description or grate/hearth    A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume    At least 3 cubic meters
Mixing chamber volume    At least 1 cubic meters
Settling chamber volume    At least 3 cubic meters
Weight excluding chimney    15, 000kg at manufacture
Firing tools supplied    Hoe, Poker and rakeMaterial of construction    Case – 5mm mild steel.
Bracing – Heavy angle and channel.
Hearth – 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Ashing door – High grade cast iron.
Loading door – 5mm mild steel lined with 1550⁰C castable  general purpose high strength, high abrasion resistant monolithic refractory concrete.
Refractory  concrete:
Alumina content of refractory
Refractory thickness
Minimum 49%
At least 127mm.
Insulation  to walls     1000⁰C Castable insulation
Chimney stack:
Chimney
Height from base    3.5 mm mild steel
9 meters above ground level and clear the highest point of the building by not less than 3 meters
At least 560mm
At least 750Kg
Controls:
Draught

Air supply

Electric

Barometric indicator, door operated draught limiter

Built-in forced heated air ducts, primary and secondary (intensifier)
Control panel – Circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer.
Electricity supply required    415 Volts Three phase.
Auxiliary  fuel    Electrically operated only
Emission     Multiple chamber design with inbuilt emission control
Paint: Case and stack    400⁰C Heat Resistant Grey
Temperature of case    100⁰C



WASTE BROCHURES In Addition To CONTAMINATED PRODUCTS LIST



1 Burner 30 =KG burn/h as well as also it need to have a Scrubber.

2 Heater ought to have Electric Plastic Shredder for reducing of glass container, surange of Drug.

3 Heater need to have Electric Auto Clave or Microwave for Dis Infection individually with burner.
4 Incinerator requires to have Double Chambers initially Chamber ought to given 800C temperature level as well as additional Chamber functioning 1200C temperature degree.
5 Incinerator in out place have to have a Specification to reveal internal temperature degree of incinerator.
6 Heater needs to operate in 2 systems Electric and also gas discuss in which kind of fuel jobs.
Note we want it services gas as well as also electrical also.for a little pig slaughterhouse job in Vietnam we are searching for a.
service to ruin safely inedible as well as taken family pet things.

As the slaughtered pigs are consumed by greater than 90% (from unguis to.
head, blood, etc) the waste volume is rather small likewise in.
slaughter-points with as long as 100 slaughtered pigs daily.

Although making use of meat as well as additionally bone meal is not banned in Vietnam the.
tiny amounts of waste do not seem to necessitate the installation of a.
providing system, not additionally of a batch cooktop, so incineration seems to be.
the very best choice.

I desire to get back at a lot more technical details e.g. gas use for.
blazing 100/200 kg of animal items each day as well as additionally the FOB.
price of the unit.The kinds of waste to be dealt with are (after EUROPEAN WASTE PAMPHLETS AND ALSO CONTAMINATED PRODUCTS CHECKLIST, 2002):

18 01 01 sharps (other than 18 01 03)

18 01 02 body elements and also body organs including blood bags as well as likewise blood keeps (other than 18 01 03)

18 01 03 * wastes whose collection and additionally disposal goes through unique needs to avoid infection

18 01 04 wastes whose collection as well as disposal is not subject to one-of-a-kind requirements in order to secure versus infection (for instance dressings, cast, linen, non reusable clothes, infant diapers)

18 01 06 * chemicals consisting or including of risky compounds

18 01 07 chemicals besides those mentioned in 18 01 06

18 01 08 * cytotoxic in addition to cytostatic drugs

18 01 09 drugs apart from those talked about in 18 01 08

18 01 10 * amalgam waste from dental therapy