Archive: April 29, 2021

Pyrolytic Dual Chamber Burner Small Dimension : Burning Rate : 30-45 kg/hr ; Optimum Load Capacity : 400 kg



Items/Model

TS50( PLC)

Picture

Principle

Solid Waste Incineration

Burn Price

30-45 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Incinerator)

Burning Chamber

560L

Interior Measurements

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Oil Usage (kg/hour)

Ordinary 13.3

Gas Intake (m3/hour)

***

Temperature Display

Digital Display

Temperature Level Protection

Yes

Oil Container

800L

Feed Door

70x55cm

Chimney

5Meter

Smokeshaft Type

Stainless Steel

1st.

Gross Weight

4500kg

Outside Dimensions

230x130x155cm

2020-03-21

230x130x155cm

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



Tool Dimension : Burning Price : 60-80 kg/hr Pyrolytic Dual Chamber Burner



Items/Model

TS100( PLC)

Image

Concept

Waste Incineration Treatment

Burn Rate

60-80 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

1200L

Internal Dimensions

120x100x100cm

Additional Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Mode

Guidebook

Voltage

220V

Oil Usage (kg/hour)

Typical 20.4

Gas Usage (m3/hour)

***

Temperature Monitor

Digital Present

Temperature Security

Yes

Oil Storage Tank

1100L

Feed Door

80x60cm

Smokeshaft

10Meter

Chimney Kind

Stainless Steel

1st. Chamber Temperature Level

800 ℃–– -1000 ℃

2nd. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Exterior Dimensions

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



Plus Size Burning Rate : 150-200 kg/hr Solid Waste Devices Key and also Secondary Combustion Chamber Incinerator



Items/Model

TS500( PLC)

Photo

Concept

Waste Incineration Treatment

Burn Rate

150-200 kg/hour

Control Mode

PLC( Programmable Logic Controller Incinerator)

Combustion Chamber

2700L

Internal Measurements

190x120x120cm

Second Chamber

1300L

Smoke Filter Chamber

Yes

Feed Setting

Handbook

Voltage

220V

Oil Consumption (kg/hour)

Typical 28

Gas Consumption (m3/hour)

***

Temperature Display

Digital Show

Temperature Defense

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Smokeshaft Type

Stainless Steel

1st.

Gross Weight

15000kg

Outside Measurements

400x210x300cm( without chimney)

2020-03-21

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



hiclover incinerator 100-150kgs per hr



Model

YD-100

Image

Burning Rate

100-150 kgs/hour

Key Burning Chamber

2000 Liters

Additional Combustion Chamber

500 Litres

Feed Mode

Guidebook

Voltage

220V/380V

Power

2.5 Kw

Fuel Kind

Diesel Oil

Heater

Italy Original

Oil Consumption (Diesel Oil)

Ordinary 28 kg/hour

Gas Consumption (Natural Gas)

***

Inner Measurements

180x115x98 centimeters (key chamber)

External Measurements

270x185x280cm (without chimney)

Temperature Screen

Yes

Oil Storage Tank Capacity( if oil fuel)

200 Litres

Door Opening

55 x 80cm

Chimney Size

6.0 Meters

Smokeshaft Kind

Steel

Devices Gross Weight

9000 kgs

Operation Technical Specifications

Key Chamber Temperature

800 ℃–– -1000 ℃

Second Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Performance

> 98%

Waste Lower Calorific Power

3500Kcal


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22



Large General waste incinerator Burn Price as much as 250kg per hr



Items/Model

TS300( PLC)

Concept

Waste Incineration Therapy

Burn Price

Average 250 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

2000L

Interior Dimensions

170x120x100cm

Secondary Chamber

1000L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

2.5 Kw

Oil Intake (kg/hour)

Average 28( DO)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Present

Temperature Defense

Yes

Oil Tank

1000L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Type

Stainless Steel

1st.

Gross Weight

11000kg

External Dimensions

400x210x300cm( without chimney)

2020-03-22

400x210x300cm(without chimney)

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22



Medical Waste Burner for Coronavirus Condition



Coronavirus Disease 2019 (COVID-19) pandemic continues all over the world, clinics,hospitals,goverment may need to consider on-site disposal for the infectious 

medical waste. The medical waste incinerators that has been effectively used to dispose of hazardous waste during 

viral outbreaks like Ebola. HICLOVER.COM reaches temperatures of up to 1200oC and is able to destroy health care waste 

for laboratories, small clinics, and hospitals treating patients of the Novel Coronavirus (COVID-19) such as linens, sharps, gauze, gowns, etc.



Clicky


Open chat








Containerized Mobile Burner Medical Waste Incinerator Model CA50



HICLOVER – Containerized Mobile Incinerator Medical Waste Incinerator Model CA50


Design

CA50

Picture

Waste Therapy

Medical Waste Incineration Treatment

Feed Capacity

Typical 100 kgs per feeding

Burning Rate

Average 50 kgs per hr

Burning Time per Feed

Average 2 hr

Control Setting

PLC( Programmable Logic Controller Burner)

Voltage

220V

Power

1.0 Kw

Gas

Diesel oil

Burner

Italy Burner

Feed Mode

Guidebook

Temperature Monitor

Digital Display

Gas usage (Oil)

Ordinary 16.9 Kgs/Hour

Inner Measurements

100x80x70cm (Key Chamber)

External Dimensions

230 x 130 x 155cm (text)

Waste combustion chamber

560Liters

Message Combustion Chamber

280Liters

Oil Tank Capacity

200 Litres

Door Opening

70 x 50cm

Chimney

5.0 M

Gross Weight

4500kgs

Chamber Product

Firebrick, Refractory Concrete

Max. Warmth Value

166,000 Kcal/Hr.

Procedure Technical Specifications

Solid Chamber temperature

8000C -10000 C

Gas Chamber temperature level

10000C -12000 C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning efficiency

> 98%

Waste Lower Calorific Power

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-24



Small Medical Waste Incineraotr for COVID-19 Bio Hazardous Medical Waste



HICLOVER – Medical Environmental 

Model

YD-20

Photo

Burning Rate

Typical 20 kgs/hour

Feed Capability

Ordinary 60 kgs/feeding

Main Burning Chamber

360 Litres

Secondary Burning Chamber

200 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Setting

Guidebook

Voltage

220V

Power

1.0 Kw

Gas Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Intake (Diesel Oil)

Standard 13.3 kg/hour

Gas Usage (Gas)

***

Inner Dimensions

100 x 60 x 60cm (key chamber)

Outside Dimensions

145 x 90 x 260cm (without smokeshaft)

Temperature Level Screen

Yes

Oil Storage Tank Capability( if oil gas)

200 Litres

Door Opening

48 x 60cm

Chimney Length

5.0 Meters

Smokeshaft Kind

Stainless-steel

Equipment Gross Weight

2300 kgs

Operation Technical Specs

Primary Chamber Temperature

800 ℃–– -1000 ℃

Second Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98%

Waste Lower Calorific Power

3000Kcal

Wearing a face mask to keep out the coronavirus has become an essential part of everyday life for many people 
around the world, but the huge amount of waste being created as the single-use items are tossed aside has the 
potential to become an ecological disaster.

How to deal with discarded face masks, which number in their millions or even billions, is another headache for 
Chinese authorities already caught between containing the viral disease and limiting the economic damage caused by it.

The country’s inadequate medical waste treatment capabilities have also been put under the spotlight, environmental experts said.

Environment and health authorities say masks and other protective gear, especially items used by medical personnel and 
people infected with the coronavirus, should be treated as clinical waste, and sterilised before being incinerated at high 
temperatures at dedicated facilities.

While it is difficult to get an exact figure on the number of discarded masks, it is reported that the volume of medical 
waste in Wuhan, the city in which the epidemic began in December, had quadrupled to more than 200 tonnes a day last 
week, according to mainland Chinese media reports.

The total amount of medical waste gathered across Hubei province on February 24 totalled 365 tonnes, of which 60 per 
cent came from hospitals, the report said.

By comparison, Wuhan produced 17,000 tonnes of medical waste in the whole of 2018, according to the country’s top 
environment watchdog.

Eric Liu, a toxic waste specialist at Greenpeace’s Beijing office, said China had a huge shortage of waste disposal facilities, 
specifically those capable of handling clinical waste.

“The waste treatment capacity in China, especially in terms of medical and hazardous waste, is barely enough to cope 
with everyday needs, let alone the country’s biggest public health crisis in decades,” he said.

While the environment ministry said most medical waste was being properly dealt with in major cities, just 31 per cent 
of the country’s 629,000 tonnes of medical waste were treated in 2015, up from 24 per cent in 2008, Xinhua reported 
last year, citing an industry study.

Du Huanzheng, director of the Recycling Economy Institute at Tongji University in Shanghai, also expressed concerns 
over the widening supply-demand gap in medical waste treatment, but said a large number of new facilities were being built or planned.

“The disposal of medical waste is a major part of the battle against the outbreak, which is a wake-up call for the government 
to speed up the construction of new facilities and research into waste treatment technologies,” he said.

The coronavirus outbreak could be the catalyst for expanding the medical waste sector and lead to the building 
of more incineration facilities, the experts said.

They said combustion remained the preferred means for disposing of medical waste in China, although industrialised 
countries were phasing out incinerators due to health and environmental concerns.

Masks could be split into three categories, Liu said. While clinical waste must be disposed of at dedicated incineration
 facilities, masks used by healthy people could be tackled in a similar way as household waste, which was burnt in industrial furnaces, he said.

The real challenge came from those used by people who were placed under home quarantine or others with mild symptoms, he said.

“There is a grey area over this kind of used mask, which are not under the jurisdiction of medical institutions but should 
be treated in accordance with standards for medical waste.”

In Wuhan, authorities are scrambling to find solutions to the challenge. The environment ministry said the city’s five incinerators 
for household waste disposal and various industrial furnaces at cement and other factories had also been assigned to help clear 
the garbage backlog, which stood at about 190 tonnes as of February 24.

According to a report by China Economic Daily, Wuhan is rushing to build more medical waste treatment plants near hospitals, 
including ones near Huoshenshan, Leishenshan and Jinyintan hospitals that will treat nine, 15 and four tonnes of clinical garbage respectively on a daily basis.

A total of 17 temporary storage facilities for medical waste, with a combined capacity of more than 1,000 tonnes, have also been built.

While authorities had to transfer some of the garbage produced in Wuhan to neighbouring cities for incineration, they have also 
tried to enlist help from waste treatment companies around the country.

China Shipping Group and a company in Anhui deployed a number of mobile medical waste incineration cabins to Wuhan last month, Xinhua reported.

The incinerators, each of which is capable of processing five tonnes of waste a day, were first used in 2003 during the Sars outbreak.


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-24



Containerized Type Pre-Assembled Mobile Medical Facility Waste Burner Model CA100



Items/Model

CA100

Image

Concept

Medical Waste Incineration Treatment

Burn Price

Average 100 kg/hour

Feed Capability

Standard 200kg/feeding

Control Mode

PLC( Programmable Logic Controller Burner)

Burning Chamber

1200L

Internal Measurements

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Power

1.3 Kw

Oil Consumption (kg/hour)

Ordinary 20.4 Kgs/Hour

Gas Usage (m3/hour)

***

Temperature Display

Digital Show

Temperature Level Defense

Yes

Oil Container

200L

Feed Door

80x60cm

Smokeshaft

5Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-25



3 Combustion Chambers MEDICAL WASTE BURNER



Model

WS-35

Image

Burning Rate

Ordinary 35 kgs/hour

Feed Ability

Average 80 kgs

Main Burning Chamber

460 Litres

Secondary Burning Chamber

200 Liters

3rd Burning Chamber

200 Litres

Smoke Filter Chamber

Damp Scrubber System

Feed Setting

Handbook

Voltage

220V

Power

2Kw

Fuel Type

All-natural Gas/LPG

Burner

Italy Original

Oil Intake (Diesel Oil)

***

Gas Consumption (Gas)

Average 24 m3n/hour

Inner Dimensions

110 x 70 x 60cm (main chamber)

Outside Measurements

160 x 100 x 180cm (without wet scrubber)

Temperature Display

Yes

Oil Container Ability( if oil gas)

***

Door Opening

50 x 50cm

Smokeshaft Length

5.0 Meters

Smokeshaft Kind

Stainless-steel

Tools Gross Weight

5000 kgs

Operation Technical Specs

Primary Chamber Temperature Level

800 ℃–– -1000 ℃

Secondary Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Performance

> 98%

Waste Lower Calorific Power

3000Kcal

Primary chamber:
Heavy duty mild steel casing, High quality Refractory lining and insulation 01 x natural gas ignition burners (automatic) 01 x temperature 

sensor points with complete internal fans.
Secondary Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas burners (automatic) with complete 01 internal fans. 

02 Sec gas residence times.
Third Chamber:
Heavy duty mild steel casing, high quality refractory lining and insulation 01 x natural gas ignition burners (automatic) with complete internal 

fans. 02 Sec gas residence time.

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-25