Archive: April 18, 2021

castable excellent quality refractory cellular lining as well as incinerator covering

The incinerator will have chimney, castable top quality refractory cellular lining as well as burner shell, perforated blind for the main as well as additional combustion chambers and air blood circulation system.

The burner shall likewise have the following:-.
– Ash door.
– Primary as well as secondary heaters and also fans.
– Temperature level indication gadgets.
– Electrical circuitry from the neighborhood isolator.
– FD fan.
– Air receiver.
– Air ductwork complete with air dampers.
– Pressure as well as temperature level assesses.
– Fully wired control panel

The bulk oil storage tank shall have a capacity of 10,200 litres as well as be put at 0.5 m above ground on a firm concrete cradle, total with the following:-.
– Drain pipeline.
– Air vent pipe.
– Oil level sign.
– Gain access to ladder to the top of the storage tank.
– Finishing of the container with a minimum of 2No. layers of bituminous paint.
– Manhole cover total with a gasket.
– Dip stick.
– Any type of various other essential device.

E-2

The daily oil tank of capacity 1,800 litres as well as dimension 1220x1220x1220mm pressed steel tank high shall be placed 2.5 metres high above finished floor level on a steel stand, strongly secured on the ground and also the steel participants to be bolted. The everyday oil container shall have an oil degree indicator, accessibility manhole, washout, overflow, inlet as well as outlets connections and gateway valves.

The adjoining pipeline of 50mm size between both storage tanks will be class ‘C’ black mild steel pipe, complete with a 50mm diameter filter. The burner fuel supply pipe from the day-to-day container will be a 25mm size class ‘C’ black mild steel.

The adhering to will additionally be supplied.
– 25mm diameter fire valve.
– 25mm size high capacity strainer.
– home heating faucet along the heater supply pipe, 25mm size

The heater supply pipe will have 25mm thick fiber glass insulation and do with gauge 20SWG galvanised steel sheet.

The tenderer will give all the required controls for appropriate safety and also acceptable working of the installment.

1.1.1 HEATER

The heater shall be suitable for 35 sec redwood No. 1 scale fuel oil. It will be robust in building and construction and be produced in actors iron or other appropriate products full with placing plates. It needs to be quickly mountable and also demountable for convenience of cleansing and upkeep. The heater shall have an appropriate supply of oil which will easily stir up as well as burn in a secure way. Sufficient provision will be offered to prevent any solid matter in the oil, or any type of issue that may divide out from the oil from harming any parts or chocking of any kind of orifices or shutoffs. The complimentary filtering system location ought to be sufficient to make sure that the filter does not need dismantling for cleaning up more often than annually. The burner will have fire guidance by photo-electric cell with concurrent sequence controller for automated start up, running and shut-down of the burner.

The burner shall have all the essential controls e.g.Solenoid shutoffs, ignition controls, image electrical cell gas safety and security controls, low stress fuel supply cut-off etc.

The heater will satisfy BS 799: part 3 as well as 6 1981 or any other pertinent British standard.The burner shall be as NU-WAY models or equivalent and also accepted.

1.1.2 CONTROLS

The incinerator shall operate in an automatic manner with all the required controls. These controls are to include security elements such as fire failing unit, pilot lights, integrates, beginners, overload contactors, ON as well as OFF switches for heaters and also followers, combustion chamber temperature signs for primary and also second chambers etc.

i) Electric ignition button ‘ON’ prior to the oil is supplied.
ii) Delayed return to re-start setting to permit purging.
iii) Re-start after temporary electrical supply failing.
iv) Favorable safety and security lock-out in instance of flame failing from whatever reason.
v) Red signal light on control board to indicate safety and security shut out.
vi) Image electric protective cell as fire failing tool.

The controls shall be mounted on appropriate control panel to be mounted in a position easy to review and manage from the charging door side of the incinerator.

The control board will be produced from anodized, 16SWG, light steel sheet.

MEDICAL WASTE INCINERATORS

MEDICAL WASTE INCINERATORS for providing, setting up, adjusting, and also screening instantly controlled air medical waste incinerators having a capacity to melt 75 Kg/hour waste materials of biological and pathological nature.

The process of incineration provides the advantage of volume reduction along with the ability to throw away recognizable waste and sharps. On site incinerators provide a quick and easy method of disposing clinical waste. This is the most extensively approved as well as possible method of handling highly infectious waste.
The burner will certainly be of the controlled air kind, developed for (6-8) hour-day procedures and also rated at 75 kg per hour. The burner plant will include the following:
3Continuous loading using hydraulic ram feeder o Burners and fuel system
o Fans
o Pumps
o Controls and Instrumentation o Chimney and flue connections
o Incinerator loader for loading receptacles or carts o Ash dealing with tools
41 year extra parts
5Waste weighing tools
6Wheeled 2.0 m3 waste storage space receptacles (number to be chosen by health center supervisors).
7Incinerator loader.
8Incinerator structure, consisting of fire safety tools.
9Platform and also portholes developed to USEPA requirements to help with stack testing.

The publications listed below form a part of this spec to the degree referenced. The publications are described within the text by the standard classification just.
AIR ACTIVITY As Well As CONTROL ASSOCIATION INTERNATIONAL (AMCA) AMERICAN CULTURE OF CIVIL ENGINEERS (ASCE).
AMERICAN WELDING SOCIETY (AWS).
ASME INTERNATIONAL (ASME) Sheet, Cold-Rolled, Carbon, Structural,.
High-Strength Low-Alloy and also High-Strength Low-Alloy with Improved Formability, Remedy Hardened, and also Bake Hardened.
SECTION 11 82 21 Web page 6.
ASTM A53/A53M (2010) Requirement Requirements for Pipeline,.
Steel, Black as well as Hot-Dipped, Zinc-Coated, Welded and Seamless ASTM A653/A653M (2010) Standard Spec for Steel

Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Girl hardened) by Hot-Dip Refine FM GLOBAL (FM).
ISA – – INTERNATIONAL SOCIETY OF AUTOMATION (ISA).
MAKERS STANDARDIZATION CULTURE OF THE VALVE As Well As INSTALLATIONS SECTOR (MSS).
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA) NATIONAL FIRE DEFENSE ASSOCIATION (NFPA).
UNITED STATE DIVISION OF DEFENSE (DOD).
UNITED STATE GENERAL SERVICES ADMINISTRATION (GSA) EXPERTS LABS (UL)

healthcare risk waste and also general waste incinerator

We pursue a sustainable growth consequently we are adopting a lasting medical waste monitoring system, that includes constructing a modern-day lasting incinerator that will not only cater for our facility yet also for the various other centers in the bigger location of the area. We realize that we require a contemporary burner that will certainly not concern the local individuals or the neighborhood environment much more. There are a number of different sorts of incinerators available (particularly suggested to be constructed with neighborhood materials), which are economical to construct however are a lot more hazardous to people as well as environment.slaughterhouse in Afghanistan in ministry of farming. Each plant has capability of 100 livestock and 500 sheep per day.burn dead chicken of weight 50 kg.4. Waste type: health care danger waste and basic waste
5. Chimney:
Smokeshaft: 3.5 mm light steel
Elevation from base:11 m and also if there are buildings within
30m of the burner, chimney should extend at the very least 3m
above the apexes of all the roofing of such buildings
Diameter of smokeshaft at top:430 mm.
Weight of stack: ± 500 Kg.
Instance and stack be repainted with 400 ⁰ C warmth immune Black paint.
6. Heaters:.
1st chamber 850 ⁰ C – – 900 ⁰ C.
2nd chamber 1000 ⁰ C.
7. Variable rate burning air blowers.
8. Primary chamber quantity ± 1.05 cubic metres.
9. Mixing chamber quantity ± 0.30 cubic metres.
10. Resolving chamber quantity ± 0.89 cubic metres.
11. Weight excluding smokeshaft ± 6.400 Kg at manufacture.
12. Shooting tools provided: Hoe, poker as well as rake.
13. Dimensions.
Size ± 2125mm.
Width ± 1890mm.
Height ± 2125mm.
Extra size for burners ± 1000mm.
14. Packing door opening up 610 * 540mm.
15. Hearth location ± 1.19 square metres.
16. Description of grate/hearth: A complete hearth to be supplied to avoid contaminated.
17. Fluids from flowing right into ash pit without being blazed.
18. Conformity with South African Atmospheric Contamination Prevention Act No. 45 of.
1965 or equal air pollution criteria.
19. Files to be supplied: Procedures and also upkeep guidebook as well as requirement.
operating treatments (SOPs).
20. Exhaust controls:.
warmed refractory display.
Low speed grit settling chamber.
Stainless-steel arrester screen
21. Refractory material: alumina content> > 49% as well as density ordinary 102mm.
22. Cook out: to be done over 2-3 days.
23. Products of buildings.
Case:5 mm moderate steel.
Supporting: heavy angle and also channel.
Hearth: 1550 ⁰ C.
Ashing door: high quality cast iron.
Packing door 5mm moderate steel lined with 1550 ⁰ C castable basic purpose high strength, high abrasion resistant monolithic refractory concrete.
Incinerator wall surfaces as well as roofing: 1550 ⁰ C castable monolithic refractory

an incinerator for food waste and also polythene waste management

an incinerator for food waste and polythene waste administration. as per our requirements we would such as the YD 15C tiny incinerator.Mixed Biomedical waste Incinerator.Contract duration: To be made a decision by the supplier
Settlement terms:100% prepayment through financial institution TT after signing of agreement.

Please verify your determination to execute this contract task by sending out pamphlet and also your price quotation for the below spec to enable us submit it to the company incharge of the contract for their study and also approval.

Kind Of Waste: Mixed Biomedical waste.THE INCINERATOR AS REQUESTED BY OUR CLIENT SHALL BE SEMI AUTOMATIC WITH:
WASTE BUCKET/TANK – – ABOUT 2000KG
ABILITY OF FEEDING: REGARDING 600-800Kg Each Time.
MELTING AT ABOUT 150/165 -200 IN 60MINS
THE BURNER SHALL USAGE DIESEL/OIL
WITH CHIMNEY, ELECTRIC PANNELS, ELECTRIC MOTORS, And So On
. PRODUCTS FOR DISPOSAL: SHARP MEDICAL WASTES.

1. Waste burning ability of unit: 100-125 kgs/ human resources.
2. Mode of waste handling: Autoloading– DFDV + Bucket elevator
3. Kind of gas: LDO/ HSD
4. Sort of Heater procedure: Automatic
5. Anticipated fuel consumption: 30-35 kgs/hr **( depending upon general
mix of the waste, dampness
content, etc.) after preheat.
6. Connected electrical lots: Approximate. 7-8 KW (A/C 3 stage,220 V, 50 Hz).
7. Overall room demand: 9 m (L) X 8 m (W) X 6 m (H) Each unit
without stack

Burners temperature level regulated (TIC– Thermocouple) and also deal with ON–.
OFF basis. The regularity on ON– OFF will depend upon the nature of.
waste, wetness web content, calorific worth, and so on as well as will differ from waste to.
waste. The gas usage likewise depends upon the frequency of the door.
opening up as well as technique of operation of the incinerator. We have actually mentioned.
approx. anticipated fuel usage figures.

The Incineration System comprises of:

I. Main Incinerator with.
A. Primary & & Additional Chamber Modules appropriately refractory lined, piped & & wired.
B. Container lift + DFDV device for autoloading and also Deashing.
device.
II i. 1 No. totally automated Gas Oil burner for primary chamber.
ii. 1 No. fully automatic Fuel Oil heater for additional chamber.
III. Centrifugal forced draft follower setting up complete with motor drive, duct and also.
dampers, and so on installed on the typical skid of the device to offer:.
Burning air.

Eductor air.
IV. Eductor Setting up for:.
Air conditioning of exhaust gases from 900– 1000 0 C to around 350 0 C.
Maintaining the entire system under adverse stress to stay clear of hot gases/ dust.
bits rushing out of billing door.
V. Electric Control Panel together with safety and securities, and also Sound/ Visual.
signs and.
/ or alarms for efficient and also risk-free procedure of the system.
VI. Electric electrical wiring of the device.
VII. Oil storage tank of 1000 ltrs ability mounted on the skid.
VIII. Operating tools and takes on consisting of– rake, hoe, shovel (I No. each).
IX. Smokeshaft of 2.5 Mtr elevation.

ADVANCED MEDICALWASTE BURNER

Incinerator model A.
Burn Rate 65kg/h minimum.
Weight (kg), please suggest:.
Secondary Chamber.
Gas Retention Time – – 2 Seconds. Fuel – Diesel/LPG/LNG, please suggest. Power Supply for – Control Box – 220V-240V 50Hz single phase. Minimum operating temperature level 850 ° C, please suggest. One year Spare Components Package for complete maintainability. 10m Pipe Pipeline, indicate size.
I000 Litre Gas Container + Pipe System, show quantity.
Added chimney extension, suggest height.
Guarantee, indicate no of years.
i. The main combustion chamber will be accepted as the main burning zone;.
ii. The minimum combustion temperature level of the primary chamber will not be less than 800 degrees C;

Secondary combustion.
The home time in the second chamber shall not be less than 2 seconds;.
The gas temperature level as measured versus the within wall surface in the second chamber, not in the fire area, shall not be much less than as shown in Lots 1-7;.
Both the main as well as the second temperature levels will be kept till all the waste has been completely combusted;

Smokeshaft.
The smokeshaft shall have a minimal height of 4 meters over ground degree;.
The minimum exit speed of the emissions shall not be less than 10 metres/second;

Temperature Level Warnings.
A distinct and/or visible alarm system to advise the driver when the secondary temperature drops to listed below the required temperature;

General.
Control box can be removed as well as mounted on separate stand at the very least 1.5 meters from incinerator at around 1.6 meter elevation;

Great Deal 2.
Thing 5 Incinerator design B.
Burn Rate 150kg/h minimum.
Weight (kg), please indicate:.
Additional Chamber.
Gas Retention Time – – 2 Seconds. Diesel/LPG/LNG, please indicate. Power Supply for Control Box- 220V-240V 50Hz solitary stage.
Minimum running temperature 920 ° C, please suggest.
One year Spare Parts Package for full maintainability.
Thing 6 10m Hose pipe Pipe, indicate size.
Item 7 I000 Litre Gas Storage Tank + Pipe System, suggest quantity.
Product 8 Added chimney extension, indicate elevation.
Guarantee, show no of years.
Great deal 3.
Thing 9 Incinerator design C.
Burn Rate 250kg/h minimum.
Weight (kg) please indicate:.
Second Chamber.
Gas Retention Time 2 Secs.
Gas Diesel/LPG/LNG, please indicate.
Power Supply for Control Box 220V-240V 50Hz single phase.
Minimum operating temperature level 920 ° C, please indicate.
One year Spare Components Bundle for complete maintainability.
Item 10 10m Hose pipe Pipe, indicate length.
Thing 11 I000 Litre Gas Container + Pipe System, indicate volume.
Item 12 Additional chimney extension, show height.
Warranty, indicate no of years.
Great deal 4– Heat Waste Burner.
Thing 13 HTW Burner design D.
Burn Rate – – 150kg/hour minimum.
Weight (kg), please show:.
Secondary Chamber.
Gas Retention Time 2 Secs.
Fuel Diesel/LPG/LNG, please suggest.
Power Supply for Control Box 220V-240V, single stage 50-60Hz.
Minimum running temperature 1200 ° C, please indicate.
One year Spare Components Bundle for total maintainability.
Item 14 10m Hose pipe Pipe, suggest length.
Item 15 1000 Litre Fuel Tank + Pipe System, show quantity.
Product 16 Additional smokeshaft expansion, show height.
Service warranty, show no of years.
Great deal 5– Mobile Incinerator.
2. Incinerator gives 2 chamber incineration as well as holds gasses for a minimum of 2 seconds.
3. Each incinerator has to have adequate labelling for parts/areas of high work health and safety danger on the incinerator.
4. Evidence their item satisfies pertinent nationwide or international discharges requirements, such as the USA Epa, UK Department for Setting Food.
& & Rural Matters, or European Union regulations and regulations.

Item 17 Mobile Incinerator model E.
Burn Rate 50kg/h minimum.
Weight (kg), please show:.
Secondary Chamber.
Gas Retention Time – – 2 Seconds. Gas – Diesel/LPG/LNG, please show. Power Supply for – Control Box – 220V-240V 50Hz single phase. Minimum operating temperature level 850 ° C, please show. One year Spare Components Package for total maintainability. Product 18 10m Hose Pipeline, show size.
Item 19 1000 Litre Gas Storage Tank + Pipe System, show volume.
Product 20 Additional chimney expansion, indicate height.
Whole lot 6– Mobile Burner.
Product 21 Mobile Incinerator design F.
Burn Rate 100kg/h minimum.
Weight (kg), please indicate:.
Secondary Chamber.
Gas Retention Time – – 2 Seconds. Fuel – Diesel/LPG/LNG, please indicate. Power Supply for – Control Box – 220V-240V 50Hz single phase. Minimum running temperature 850 ° C, please suggest. One year Spare Parts Plan for full maintainability.
Product 22 10m Hose Pipe, show length.
Thing 23 1000 Litre Fuel Storage Tank + Pipeline System, suggest quantity.
HTW Mobile Incinerator design G.
Burn Price 100kg/h minimum.
Weight (kg), please indicate:.
Additional Chamber.
Gas Retention Time – – 2 Seconds. Fuel – Diesel/LPG/LNG, please indicate.
Power Supply for Control Box – – 220V-240V 50Hz solitary stage.
Minimum running temperature 1200 ° C, please suggest.
One year Spare Components Bundle for total maintainability.
10m Pipe Pipe, indicate size.
1000 Litre Fuel Storage Tank + Pipeline System, suggest volume

Requirements for Dual Chamber Burner

INCINERATOR DESCRIPTION
The Model is for up to 300kgs ability per batch tons as well as will certainly shed at around 55kgs per hour.
The unit has leading packing style and has a strong refractory concrete lining for optimum heat retention. Device have large leading cover for very easy loading, as well as specifically designed front ash door, for ash removal.
This unit runs at over 1100 ° C in the key chamber to guarantee complete combustion. This model also benefits
from a heavy duty secondary chamber as well as burner which makes certain a full re-burn of any smoke as well as exhausts as well as a 0.5 2nd gas retention time.
Melt rate 150kg/h minimum
Secondary Chamber Yes.
Gas Retention Time 2 seconds.
Gas Diesel/LPG/LNG.
Power Supply for Control Box 220V-240V 50Hz solitary stage.
Minimum Operating Temperature Level 920 ˚C

PRIMARY CHAMBER.
Durable steel case.
Excellent quality refractory lining and insulation.
Huge full dimension leading load door and liquid retention sill.
1 x diesel oil terminated ignition heaters operated on/off.
ADDITIONAL CHAMBER.
Heavy-duty steel housing.
Top quality refractory lining as well as insulation.
1 x diesel oil fired ignition heaters operated on/off.
Requirements for Double Chamber Incinerator:.
Primary Burning.
The main combustion chamber shall be approved as the key burning area.
The minimum combustion temperature of the key chamber shall not be less than 800 degrees c.
Secondary Combustion.
The house time in the second chamber will not be much less than 2 secs.
The gas temperature level as measured versus the inside wall surface in the secondary chamber, not in the fire zone will not be less than as suggested in Whole lot 1-7.
Both the main and also secondary temperatures shall be preserved till all the waste has been entirely combusted.
Chimney.
The chimney shall have a minimal height of 4 metres above ground level.
The minimal exit speed of the emissions will not be less than 10metres/second.
Temperature Warnings.
A distinct and/or noticeable alarm to alert the operator when the second temperature level drops to listed below the needed temperature.
General.
Control box can be separated and also installed on different stand of atleast 1.5 metres from the burner at approximately 1.6 metre elevation.
CE certified or equivalent for incinerators of this dimension and also design.
Drawings as well as images for the provided whole lots.
1 year spare parts, fuel tanks as well as 10metre pipe to come common with every burner.
Specs for Mobile Burner Units.
Trailer mounted mobile incinerator devices ideal for the following applications.
Medical waste.
Residential waste.
Industrial waste.
Animal cadavers.
SMOKESHAFT.
Durable stainless steel case.
1.5 m size.
0.6 m refractory lined stack.
CONTROL PANEL.
Control of 1 heater.
Timer control 0- 12 hrs.
Essential fan timer control.
Temperature Tracking.
Thermostatic Control.
Automatic Control.
Cycle time established.
ANCILLARIES.
Operating as well as maintenance handbooks.
Saves listing.
CONTAINERISATION.
incinerator totally installed within 10 ft ISO accredited container.
3,5 kwA electrical power generator, 1000 litres fuel storage tank.
Incinerator mounted on the silenblock padding.

Diesel/LPG/LNG burning key burning chamber/primary combustion incinerator

Main burning
Diesel/LPG/LNG burning key combustion chamber/primary combustion zone
Second burning
Home time in the second chamber not less than 2 secs
Both key as well as the secondary temperatures preserved up until all the waste has actually been completely ignited
Chimney
Chimney with a minimal height of 4 meters above ground level
Minimum leave velocity of the discharges not much less than 10 metres/second
Temperature level Cautions
Distinct and/or visible alarm to warn the driver when the second temperature drops to below the required temperature
General
Control box that can be separated as well as installed on different stand a minimum of 1.5 meters from burner at around 1.6 meter

heightItem 1
Burner design A

Melt Rate 65kg/h minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time – – 2 Secs

– Fuel – Diesel/LPG/LNG, please show

Power Supply for Control Box – 220V-240V 50Hz single phase

Minimum running temperature level 850 ° C, please suggest

One year Spare Components Plan for complete maintainability

10m Tube Pipe, suggest size

I000 Litre Gas Tank + Pipeline System, show volume

Additional smokeshaft expansion, indicate elevation

Service warranty, suggest no of years

Item 2
Incinerator design B

Melt Rate 150kg/h minimum

Weight (kg), please suggest:

Additional Chamber

Gas Retention Time – – 2 Seconds

Diesel/LPG/LNG, please show

Power Supply for Control Box- 220V-240V 50Hz solitary stage
Minimum operating temperature level 920 ° C, please indicate
One year Spare Parts Bundle for total maintainability
10m Hose Pipe, indicate size
I000 Litre Gas Storage Tank + Pipeline System, suggest volume
Added smokeshaft expansion, suggest elevation
Warranty, show no of years

Product 3
Incinerator version C.
Burn Rate 250kg/h minimum

Weight (kg) please show:.
Second Chamber.
Gas Retention Time 2 Secs.
Fuel Diesel/LPG/LNG, please show.
Power Supply for Control Box 220V-240V 50Hz single stage.
Minimum running temperature 920 ° C, please suggest.
One year Spare Components Bundle for full maintainability.
10m Hose pipe Pipe, indicate size.
I000 Litre Gas Tank + Pipeline System, indicate quantity.
Extra chimney expansion, indicate height.
Warranty, indicate no of years

Heat Waste Incinerator

Capacity at least (4000) kg/day (( Day= 16 Working Hrs))

Ability at least (4000) kg/day (( Day= 24 Working Hrs))

With the following attributes:

* Automatic feeder as original part of the unit.

* Automatic ash/ leftovers elimination as initial component of the unit.

* Water Injection System to control the temperature> >

* Flue gas filtering system abiding by EU.

* Continual discharge tracking and recording system.

* It should include setup, testing, and also personnel training.

* 6 nos. of sturdy filling containers.

Item 4.
HTW Incinerator design D.
Burn Price – – 150kg/hour minimum.
Weight (kg), please indicate:.
Secondary Chamber.
Gas Retention Time 2 Seconds.
Gas Diesel/LPG/LNG, please show.
Power Supply for Control Box 220V-240V, solitary phase 50-60Hz.
Minimum running temperature 1200 ° C, please show

One year Spare Parts Plan for complete maintainability

10m Tube Pipe, show size.
1000 Litre Fuel Tank + Pipeline System, indicate quantity.
Extra chimney extension, suggest height.
Mobile Burner

Item 5.
Mobile Burner version E

Melt Price 50kg/h minimum

Weight (kg), please show:

Secondary Chamber

Gas Retention Time – – 2 Seconds

– Gas – Diesel/LPG/LNG, please suggest

Power Supply for Control Box – 220V-240V 50Hz solitary stage

Minimum running temperature level 850 ° C, please suggest

One year Spare Components Bundle for full maintainability.
Mobile Incinerator

Thing 6.
Mobile Incinerator version F

Melt Rate 100kg/h minimum

Weight (kg), please indicate:

Second Chamber

Gas Retention Time – – 2 Seconds

– Fuel – Diesel/LPG/LNG, please suggest

Power Supply for Control Box – 220V-240V 50Hz solitary stage

Minimum operating temperature level 850 ° C, please indicate

One year Spare Parts Bundle for full maintainability

10m Pipe Pipe, suggest size

1000 Litre Gas Container + Pipeline System, show quantity

Additional smokeshaft extension, indicate height

Warranty, indicate no of years.
Heat Waste Mobile Incinerator.
Product 7.
HTW Mobile Burner version G.
Burn Price 100kg/h minimum.
Weight (kg), please suggest:.
Second Chamber.
Gas Retention Time – – 2 Seconds. Fuel – Diesel/LPG/LNG, please indicate

Power Supply for Control Box – – 220V-240V 50Hz solitary stage

Minimum operating temperature 1200 ° C, please suggest.
Main burning.
Diesel/LPG/LNG burning main burning chamber/primary combustion zone.
Second burning.
House time in the second chamber not less than 2 seconds.
Both main and the secondary temperatures preserved up until all the waste has been entirely ignited.
Smokeshaft.
Chimney with a minimal elevation of 4 meters above ground level.
Minimum exit velocity of the emissions not less than 10 metres/second.
Temperature Warnings.
Audible and/or noticeable alarm system to advise the driver when the additional temperature goes down to below the called for temperature level.
General.
Control box that can be separated as well as mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter

elevation.
Guarantee, show no of years

Medical Waste Incinerator Trailer Mounted

*Double combustion chambers
*Smoke filter chamber and S.Steel chimney
*Italy Riello Oil burner and PLC Auto. control
*Heavy duty mobile trailer with safe parts 
*Minimal installation
*Mobile by truck tractor 
1. Should be Trailer mounted Trailer Type
2. Be able to burn Medical waste 100-200kgs per hour
3. Diesel diesel oil type
4. 220 V single phase
5. Incinerating temperature range 800-1200 degree Celsius  

Items/Model

TS100(PLC) (Mobile Type)

Picture

 

Principle

Medical Waste Incineration Treatment

Burn Rate

Average 100-200 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V

Power

0.9Kw

Oil Consumption (kg/hour)

average 20.4

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

3Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800

Containerized diesel fueled incinerators

Burner Kind: Containerized, gasoline
Burning Rate:100–– 120kg/hour.
Minimum Operating Temperature:850 o C( primary combustion).
Maximum Operating Temperature:1450 oC( Afterburner chamber).
Additional Burning Capacity: Compulsory.
Thickness Insulation:20 mm High.
Refractory Spreading: Minimum 65mm.
Sturdy refracting lining to withstand:1500 oC.
Typical stress out time: maximum:3 humans resources.
Fuel kind: Diesel.
Fuel Consumption in L/hr:7.5 to 9.
Home time in secondary chamber:2 sec.
Residue ash pot 100kg: Max 3.8 kg.
Burner kind: Animal waste incinerator.
Load Capacity minimum: 1500 kg.
Heater fuel kind: Diesel.
Burner fuel price max.: 20-25 Litre diesel/ per hr.
Heaters minimum: 3.
Burning rate minimum: 200-300kg/ per hr.
Furnace bar location minimum: 2 м3.
Gas tank capability minimum: 300L.
Key chamber burning temperature level min. 1100 0C.
Afterburner chamber burning temperature min. 1300 0C.
Power supply 220V.
Incinerator items and also electric devices ought to be weather proof and also moisture immune within the series of 30-90 %.
Incinerator needs to be compliant to the environmental management regulations in accordance to national legislation.
Maximum dimensions– Size– 5m, width– 3.5 m, elevation– 5m

Gasified incineration for melting medical wastes incinerator

Gasified incineration for burning clinical wastes.

Gas kind: Natural Gas
Burning Capacity:
–– 30-50 kg/time
–– Daily 3-6 times

Burner size: max 2000x1200x3200 mm
Burning room volume:
–– Gasification space max 0.7 m3,
–– Additional burning area max 0.5 m3 ,

Dimension of the filling up entry: max 650×× 850 mm Air blower: max 0,5 kW Combustion-support burning devices: – Power max 0,2 kW INCINERATOR (WASTE BURNER).
Created to burn disposables that can as well as ought to be ruined on-site. Theses wastes consist of transmittable and also infected “red bag.” Surgical dressings, plastic examination tools as well as various other wastes.
Rapid, total, efficient garbage disposal.
Twin chamber combustion, Chambers insulated and also lined with high temperature refractory. Programmable digital temperature controls, temperature signs and also cost recorder. Modulating control for gas as well as air decreases gas consumption.
Minimum installment and also launch time.
Aluminized steel jacket lined with refractory and firebrick. Screens recorders and also other accessory equipment must be available.
Billing system:.
– Vertical cost door on key chamber.
– Pneumatic or hydraulic ram charging system.
– Auto closed down of the door after billing.
– Main as well as secondary chamber temperature presented and recorded (optional).
Charging price:.
– As much as 100kgs per hour of waste or red bag waste ranked at 2200 BTU’s per kg.
Fuel:- Natural Gas.
Capacity (Cubic Mtr): 1.65 M3 or even more.
Ave Ability: 100kg per hr.
Additional Chamber Capacity (CubicMtr):3.88 or more.
Size (mm): 1880 or far better.
Width (mm): 1280 or better.
Height Incl. Flue (mm): 7700 or far better.
Ash Door Opening (mm): 475×× 900 or much better.
Min. Running temperature level: 90 degree centigrade.
Max, Operating Temperature: 1350 level centigrade.
Residency time in Second Chamber: 2 sec.
Temperature Monitoring: Both for main and secondary chambers.
Filling SystemManual/semi-automatic.
Waste destruction efficiency:> > 90% by weight.
Filter: Ceramic or various other equal filters in order to lower the induction of unsafe air contaminants, particulates, carbon monoxide, dioxin/furane into the environment.
De ashing system: Manual/semi-automatic.
The System needs to be priced estimate total with:-.
– Pipes.
– Electric panels.
– Civil functions.
– Waste collection Trolleys.
Re-burning machine: Power max 0,2 kW Voltage: 220V/ 380V.
Weight: max 5000 kg