50-100-150-200 Kgs per Hour Solid Waste Incinerator on Sale

Waste Incinerator Model TS150 PLC, Review

This version is small-scale waste incineration devices for little waste output.

Construction is dual/double combustion chamber with 02 sets oil burner, batch load 
incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. 
Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.


Primary Combustion Chamber: 

※Main Feature:

— Double Combustion Chamber
— Double Italy Burner
— Smoke Filter included
–Burning Rate: 50-200kgs per hour optional
–Primary Combustion Chamber: 1.57M3(1570Liters)
— Incinerator Mainbody steel: 8mm thickness 
— Paint for outside face: 800°C Rate

Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate
— Idea for campsite average or below 600 people

— Chimney: 10 Meters, Stainless steel


Feeding door primary chamber:


Items/Model

TS150( PLC)

Image

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*( 50/100/200kgs/ hr optional)

Feed Capacity

Average 750kg/feeding

Control Setting

PLC( Programmable Logic Controller Burner)

Text Steel

8mm thickness

Chamber Material

High Alumina Fire Block Wall, 1750 ℃ Price

Paint for outdoors face

800 ° C Price

Burning Chamber

1570L

Internal Dimensions

150x100x105cm

Second Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Intake (kg/hour)

Typical 20.4-28.0( D.O)

Gas Intake (m3/hour)

***

Temperature Screen

Digital Show

Temperature Level Security

Yes

Oil Container

300L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Type

Stainless-steel

1st. Chamber Temperature Level

800 ℃–– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Dimensions

300x160x280cm( without smokeshaft)




 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

Waste Incineration Therapy Design TS75( PLC).

Average 50-100 kg/hour Burn Price

Items/Model

TS75( PLC)

Concept

Waste Incineration Therapy

Burn Price

Average 50-100 kg/hour

Feed Capacity

Ordinary 200-300 kg/feeding

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Face Oil Paint

800 ℃

Combustion Chamber

768 Liters (0.768 M3)

Internal Measurements

1200x800x800mm

Additional Chamber

384 Liters (0.384 M3)

Smoke Filter Chamber

Yes

Feed Setting

Handbook

Voltage

210/240V 50Hz 1P

Power

1.3 Kw

Oil Intake (kg/hour)

Typical 20.4( D.O)

Thermal capability( kw/hour)

166-332

Gas Intake (m3/hour)

***

Temperature Level Monitor

Digital Display

Oil Storage Tank

3000L

Feed Door

60x50cm

Smokeshaft

10Meter

Chimney Kind

Stainless Steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

2nd. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

7500kg

Outside Measurements

260x160x250cm( without smokeshaft)

We provide solitary burning chamber, double combustion chambers, 3 burning chambers and multi-combustion

chambers waste incinerators for lab, center, medical facility, medical center, hygiene professional waste devastation with clinical

disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and also plasters,

sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, and so on.

Our series of incinerators provide for little to large scale pet cremation relevant companies, such as poultry farms, livestock

farms, lamb farms, pig ranches, stables, kennels, screening lab, catteries, pet crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to 

make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature 

sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.

The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation 

business owner all over the world.

The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house 

build construction, movable by truck and ultraviolet lamp sterilization inside.

We are growing brand for environmental protection field, and market share with most of 

Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental 

organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. 

We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

We are china burner manufacturer, contractor and also exporter. Supplier clear up rate for incinerator customer,

supply clinical incinerator, medical facility burner, pet incinerators, hog burners, pet dog cremation devices, tiny incinerator,

pet incinerator, pet burner, mobile burner, small pet incinerator, infectious waste pyrolysis device, laboratory

burner.

250kgs per hr ability waste incinerator

Burner Model TS250 PLC, Review

This design is small-scale waste incineration tools for small waste outcome. Construction

is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. 
Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers
and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. 

Main Product List per 01 collection

Primary Burning Chamber

Additional Combustion Chamber

Smoke Filter Chamber

Incinerator PLC Control Instance

Smokeshaft:10.0 Meters

*( upgrade to Stainless-steel, complimentary expense)

Italy oil/gas heater: 02 units

Oil Tank (if oil fuel): 300Liters








Items/Model

TS200( PLC)

Picture

Principle

Strong Waste Incineration Therapy

Burn Rate

Average 250 kg/hour

Feed Capability

Standard 350kg/feeding

Control Setting

PLC( Programmable Logic Controller Burner)

Combustion Chamber

1800L

Internal Measurements

150x110x110cm

Second Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Power

0.9 Kw

Oil Intake (kg/hour)

Ordinary 28

Gas Usage (m3/hour)

Typical 33.6

Temperature Level Screen

Digital Present

Temperature Level Security

Yes

Oil Tank

300L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

2nd. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Dimensions

300x160x190cm

Heater procedure ought to be Automatic On/Off

Gas : diesel

The vendor must supply required information for the best of the installment

This incinerator with “PYROLYTIC” combustion have to have:

;

・ Refractory concrete:

§. Density: ≥ 100 mm

§. Nature: 42% of Al203

・ Shield in coarse panels:

§. Thickness: ≥ 75 mm

・ Nature: Calcium silicate.

* Burner of illumination of waste, with gas, common mono-bloc casting directing diving flame, lights and also safety of electronic ignition, irreversible air flow, electro-magnetic sluice entrance of regulation as well as isolating valve.

* Plate of burning in Carborundum, avoiding the dealing with of glass as well as slags.

A chamber of article burning of gases

* A heater of burning of gases,

* A device of shot of air enabling a complete recombustion of gases,

* A tool of air inlet of air conditioning of waste gases,

* A sheath of emptying of the gases charred.

* Carcass in solid sheet steel with support of link.

* Structure of the refractory;

・ Refractory concrete:

§ Thickness: ≥ 150 mm

§ Nature: 65% of Al203

・ Protect in coarse panel:

§ Thickness: ≥ 85 mm

Nature: Calcium



incinerator producer 200kgs/h

Waste is thermally decayed in the main chamber at temperature levels of 800 ° C +. The resulting aeriform items are entirely oxidized in the second chamber at higher temperature levels with adequate resident time. Other specifications are as follows. A burning chamber of waste:

* Perfectly limited door for the manual loading of waste. The loading ought to be Manual, Set Load

* A burner of lights which the use is restricted to the ignition of waste.

* Frontage of loading with door seals risen on hinges, wheel of screw plug, flexible joint, as well as packing protecting out of refractory.

* The insulation of the burning chamber need to be made up of refractory bricks, having a high web content of aluminum and shields bricks in order to assure a minimum temperature on the outside sheet steel.

* Composition of the refractory

Burning Ability
Max. 200kgs/h
Supporting Gas
Diesel
Kind of Heater
Monoblock automatic heaters
Temperatures
Primary Chamber: 800 ° C ± 50 ° C. Additional Chamber: 1300 ° C ±
50 ° C. Kind. Static strong fireplace.
Product of Building and construction.
Mild Steel.
Refractory thickness.
115 mm thick.
Product.
Refractory blocks.
Insulation density.
50 mm thick.
Waste Charging.
Manual.
Ash Elimination.
Handbook.
Kind.
Static solid fireplace.
Material of Construction.
Mild Steel.
Refractory thickness.
115 mm thick.
Product.
Refractory blocks.
Insulation density.
50 mm thick.
Type.
Centrifugal.
Inflection.
Manual damper control.
Product of Construction.
Mild Steel.
Sort of temperature controller.
Digital.
End up & & paint kind.
Dual coat.
Material of construction & & capacity
. Mild Steel/ Plastic, appropriate capacity.
Other Standard Accessories.
Diesel oil degree sign, piping with shutoffs & & Non-return shutoff.
Aesthetic Monitoring of Gas.
Offered.
No. of Burners.
2 one in primary and also in second chamber).
Type & & Design
. Monoblock automated oil fired.
Make.
Riello.
Fuel.
Diesel.
Fuel shipment.
10 C 20 kg/h.
Discharging phase.
1.
Thermal power.
118 C 236 kW.
Motor power.
240 W.
Pump pressure.
10 C 12 bar (basic calibration), Max. pressure 15 bar.
Electrical supply.
Single phase 220V, 50Hz.
Material of building and construction.
Burned bricks.
Height.
9 meters from ground degree.

Containerized Mobile Kind Tool Unit Waste Burner

Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day).

Items/Model

TS50( PLC)

Image

Concept

Waste Incineration Therapy

Burn Price

Standard 50-100 kg/hour

Feed Capacity

Ordinary 200-300 kg/feeding

Control Mode

PLC( Programmable Logic Controller Incinerator)

Optional Upgrade Containerized Mobile Kind Incinerator

ISO 20′ ′ Complete Container

Burning Chamber

560L

Interior Measurements

1000x800x700mm

Second Chamber

280L

Smoke Filter Chamber

Yes

Feed Setting

Handbook

Voltage

210/240V 50Hz 1P

Power

1.3 Kw

Oil Consumption (kg/hour)

Ordinary 20.4( D.O)

Thermal ability( kw/hour)

166-332

Gas Consumption (m3/hour)

***

Temperature Level Monitor

Digital Display

Oil Tank

1000L

Feed Door

60x50cm

Chimney

10Meter

Chimney Kind

Stainless-steel

1st. Chamber Temperature Level

800 ℃–– -1000 ℃

2nd. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

7500kg

Outside Dimensions

260x160x250cm( without smokeshaft)


Double Chamber Incinerator for sale 50-200kgs per hr( in stock).

We supply Double Chamber Incinerator with primary chamber size average 1570Liters and burnning rate 50kgs per hour,100kgs per hour,150kgs per hour,200kgs per hour.

the incinerators are now ready for shipping.

Contact with us for quick respond: +86-13813931455

Key Product Listing per 01 collection

Key Burning Chamber

Second Combustion Chamber

Smoke Filter Chamber

Incinerator PLC Control Case

Chimney:10.0 Meters

*( upgrade to Stainless Steel, free cost)

Italy oil/gas burner: 02 units

Oil Container (if oil gas): 300Liters

Items/Model

TS150( PLC)

Concept

Waste Incineration Treatment

Burn Price

Standard 50/100/150/ 200 kg/hour

Feed Capability

Average 750kg/feeding

Control Setting

PLC( Programmable Reasoning Controller Incinerator)

Combustion Chamber

1570L

Inner Measurements

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Consumption (kg/hour)

Average 20.4( D.O)

Thermal capability( kw/hour)

166-332

Gas Usage (m3/hour)

***

Temperature Level Display

Digital Present

Temperature Defense

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Level

800 ℃–– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Measurements

300x160x280cm( without chimney)

Just how you can locate reasonable incinerators for your local site?

Hiclover supply medical waste incinerators with ability 10kgs per hour to 500kgs per hr.

The burner with dual/double combustion chamber as well as dry filter chamber, two fuel burner from

Italy produced, hot sale version for small scale waste result, the capability is 30kgs per hour

and also 50kgs per hr.

We are famous small scale incinerator manufacturer and brand, dispatch incinerator products 
and best services with lower price for customer all around the world.

Just how you can locate affordable incinerator for your neighborhood site?

Burner is not an economical devices, normally the tiny scale model’s cost around $5,000 usd per unit

as well as huge scale version’s rate more than $50,000 usd each. Before purchase one unit incinerator,

you have to make clear adhering to products:

A, burn what? Incinerator is a incineration tools, function is fire waste. What kind of

waste you want to treatment?

B, tiny or huge? This according to the waste result each day or the waste volume per

feed time, like animal dimension.

C, fuel? Incinerator use oil or gas fuel, usually, gas fuel is cheaper than oil and the smoke

cleaner than oil gas version. Some neighborhood website do not have gas supply system.

As well as other technology items, like power( 220v, 380v), waste feed door kind, burner framework, etc.

WWW.HICLOVER.COMWaste Incinerators Auto Roll Air Filters
Nanjing Clover Medical Technology Co.,Ltd.

Tel: +86 -25 -8461 0201

Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Hiclover biography waste incineration

HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce.

※ Main Attribute:— — Double Burning Chamber— — Double Italy Burner–– Burning Price: 10-100kgs per hour–– Burning Chamber: 0.1M3-1.2 M3— — Mobile Incinerator, Standard delivery containers, Easy to move/transport system— — Free Installation, Pre-installed burner, Suitable for camps— — Ultraviolet light sterilization inside

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm
Equipment Double chamber medical infectious waste incinerator Capacity 10-30 kg per hour Characteristics of waste
Mainly syringes and needles from immunization routine and campaign activities. However, the following average characteristics are considered*:
heating value above 2000 kcal/kg (8370 kJ/kg); content of combustible matter above 60%; content of non combustible solids below 5%; content of 
non-combustible fines below 20%; moisture content below 30% by weight
Combustion performance: The medica waste incinerator shall be capable of reducing waste to ash not exceeding 10% of the total combustible 
charges.
Outdoor installation. The medical waste incinerator will be installed outdoors. All incinerator components shall be suitable for but not 
limited to outdoor shaded installation, including electric motors, be resistent to corrosion, moisture and related weather elements.

Products of building and construction: The incinerator will not have any asbestos, asbestos-containing materials, mercury thermostats, as well as mercury switches. Refractory materials will be able to meet appropriate standards under ISO TC33 and also CEN/TC 187.

Kinds of incinerator design acceptable: Dual-chamber controlled air incinerator or dual- chamber pyrolytic incinerator


WWW.HICLOVER.COM|Waste Incinerators |Auto Roll Air Filters

Nanjing Clover Medical Modern Technology Co., Ltd.

Tel: +86 -25 -8461 0201 Site: www.hiclover.com Email: [e-mail   safeguarded] Email: [e-mail   secured]

Concerning Medical Waste

Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses.

Standard 20% -25% of the complete waste generated by medical care facilities is related to as hazardous and may create a selection of health as well as environmental dangers if not handled and damaged in an proper way. With years worth of experience in this sector, our clinical array of burners are made to provide for the economical needs of tiny facilities to the more demanding and also specialized requirements of big medical facilities in their waste monitoring processes.
HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste.

Our products make sure reliable, tidy as well as easy disposal of medical waste is possible. The incineration of clinical waste including pathological waste ( red bag waste), Biohazards & & Sharps, General Medical Waste, from Hospitals, Study Center, Drug Companies , Drug Produces, Main Treatment Trusts, Aesthetic Surgical Procedure Centers, Nursing Residences, Care Homes and other Medical Waste.

○ Middle-Small Capability( TS Model) ※ Key Qualities:— — Dual Burning Chamber— — Double Italy Heater–– Burning Rate: 10-100kgs per hour–– Burning Chamber: 0.1M3-1.2 M3 ※ Optional Function/Parts/Material/ Burning Price: — — Stainless Steel Chimney — — Dry Smoke Filter Chamber— — Chimney Elevation Customized Made— — Upgrade/Downgrade Burning Rate


○Large-Middle Capacity(YD Model)
※Main Feature:
–Three Combustion Chambers
— Double Italy Burner
–Burning Rate: 30-600kgs per hour
–Combustion Chamber: 0.36M3-5.5M3
※Optional Function/Parts/Material/Burning Rate: 
— Stainless Steel Chimney 
— Dry Smoke Filter Chamber
— Chimney Height Custom Made
— Semi-Automatic Waste Feeding
— 3-Section Wet Scrubber System
— Movable Platform Feeding Door
— Additional Burner
— Upgrade/Downgrade Burning Rate

● Service before and also after Setup — — Manufacturing facility training for installment, operational and also upkeep with totally free expense.— — Online solution support for installment, operational as well as maintenance with complimentary cost.— — Onsite installation , operational and maintenance training — Onsite solution assistance after setup

● Spare components supportHICLOVER currently uses extra parts including: — Burners( diesel oil, LPG or gas) — Element for burners — Fire ropes — Burner chamber upkeep materials — Air Fan — Temperature level aspect — Smoke filter block — Control box — Other components

Nanjing Clover Medical Technology Co., Ltd.

Tel: +86 -25 -8461 0201 Fax: +86 -25 -8461 0406

Web site : www.hiclover.com Email— : [email   safeguarded] Email: [email   protected]