and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.
Main Product List per 01 collection
Primary Burning Chamber
Additional Combustion Chamber
Smoke Filter Chamber
Incinerator PLC Control Instance
Smokeshaft:10.0 Meters
*( upgrade to Stainless-steel, complimentary expense)
Italy oil/gas heater: 02 units
Oil Tank (if oil fuel): 300Liters
Items/Model
TS200( PLC)
Picture
Principle
Strong Waste Incineration Therapy
Burn Rate
Average 250 kg/hour
Feed Capability
Standard 350kg/feeding
Control Setting
PLC( Programmable Logic Controller Burner)
Combustion Chamber
1800L
Internal Measurements
150x110x110cm
Second Chamber
750L
Smoke Filter Chamber
Yes
Feed Mode
Handbook
Voltage
220V
Power
0.9 Kw
Oil Intake (kg/hour)
Ordinary 28
Gas Usage (m3/hour)
Typical 33.6
Temperature Level Screen
Digital Present
Temperature Level Security
Yes
Oil Tank
300L
Feed Door
80x60cm
Smokeshaft
10Meter
Smokeshaft Kind
Stainless-steel
1st. Chamber Temperature
800 ℃–– -1000 ℃
2nd. Chamber Temperature Level
1000 ℃ -1200 ℃
Residency Time
2.0 Sec.
Gross Weight
8500kg
Exterior Dimensions
300x160x190cm
Heater procedure ought to be Automatic On/Off
Gas : diesel
The vendor must supply required information for the best of the installment
This incinerator with “PYROLYTIC” combustion have to have:
;
・ Refractory concrete:
§. Density: ≥ 100 mm
§. Nature: 42% of Al203
・ Shield in coarse panels:
§. Thickness: ≥ 75 mm
・ Nature: Calcium silicate.
* Burner of illumination of waste, with gas, common mono-bloc casting directing diving flame, lights and also safety of electronic ignition, irreversible air flow, electro-magnetic sluice entrance of regulation as well as isolating valve.
* Plate of burning in Carborundum, avoiding the dealing with of glass as well as slags.
A chamber of article burning of gases
* A heater of burning of gases,
* A device of shot of air enabling a complete recombustion of gases,
* A tool of air inlet of air conditioning of waste gases,
* A sheath of emptying of the gases charred.
* Carcass in solid sheet steel with support of link.
Waste is thermally decayed in the main chamber at temperature levels of 800 ° C +. The resulting aeriform items are entirely oxidized in the second chamber at higher temperature levels with adequate resident time. Other specifications are as follows. A burning chamber of waste:
* Perfectly limited door for the manual loading of waste. The loading ought to be Manual, Set Load
* A burner of lights which the use is restricted to the ignition of waste.
* Frontage of loading with door seals risen on hinges, wheel of screw plug, flexible joint, as well as packing protecting out of refractory.
* The insulation of the burning chamber need to be made up of refractory bricks, having a high web content of aluminum and shields bricks in order to assure a minimum temperature on the outside sheet steel.
* Composition of the refractory
Burning Ability
Max. 200kgs/h
Supporting Gas
Diesel
Kind of Heater
Monoblock automatic heaters
Temperatures
Primary Chamber: 800 ° C ± 50 ° C. Additional Chamber: 1300 ° C ±
50 ° C. Kind. Static strong fireplace.
Product of Building and construction.
Mild Steel.
Refractory thickness.
115 mm thick.
Product.
Refractory blocks.
Insulation density.
50 mm thick.
Waste Charging.
Manual.
Ash Elimination.
Handbook.
Kind.
Static solid fireplace.
Material of Construction.
Mild Steel.
Refractory thickness.
115 mm thick.
Product.
Refractory blocks.
Insulation density.
50 mm thick.
Type.
Centrifugal.
Inflection.
Manual damper control.
Product of Construction.
Mild Steel.
Sort of temperature controller.
Digital.
End up & & paint kind.
Dual coat.
Material of construction & & capacity
. Mild Steel/ Plastic, appropriate capacity.
Other Standard Accessories.
Diesel oil degree sign, piping with shutoffs & & Non-return shutoff.
Aesthetic Monitoring of Gas.
Offered.
No. of Burners.
2 one in primary and also in second chamber).
Type & & Design
. Monoblock automated oil fired.
Make.
Riello.
Fuel.
Diesel.
Fuel shipment.
10 C 20 kg/h.
Discharging phase.
1.
Thermal power.
118 C 236 kW.
Motor power.
240 W.
Pump pressure.
10 C 12 bar (basic calibration), Max. pressure 15 bar.
Electrical supply.
Single phase 220V, 50Hz.
Material of building and construction.
Burned bricks.
Height.
9 meters from ground degree.
Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day).
Items/Model
TS50( PLC)
Image
Concept
Waste Incineration Therapy
Burn Price
Standard 50-100 kg/hour
Feed Capacity
Ordinary 200-300 kg/feeding
Control Mode
PLC( Programmable Logic Controller Incinerator)
Optional Upgrade Containerized Mobile Kind Incinerator
We supply Double Chamber Incinerator with primary chamber size average 1570Liters and burnning rate 50kgs per hour,100kgs per hour,150kgs per hour,200kgs per hour.
the incinerators are now ready for shipping.
Contact with us for quick respond: +86-13813931455
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed. Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures, eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal for military and civil camps and remote locations where infrastructure is scarce.
※ Main Attribute:— — Double Burning Chamber— — Double Italy Burner–– Burning Price: 10-100kgs per hour–– Burning Chamber: 0.1M3-1.2 M3— — Mobile Incinerator, Standard delivery containers, Easy to move/transport system— — Free Installation, Pre-installed burner, Suitable for camps— — Ultraviolet light sterilization inside
Items/Model
TS10(PLC)
TS20(PLC)
TS30(PLC)
TS50(PLC)
TS100(PLC)
Burn Rate (Average)
10 kg/hour
20 kg/hour
30 kg/hour
50 kg/hour
100 kg/hour
Feed Capacity(Average)
20kg
40kg
60kg
100kg
200 kg
Control Mode
PLC
PLC
PLC
PLC
PLC
Combustion Chamber
100L
210L
330L
560L
1200L
Internal Dimensions
50x50x40cm
65x65x50cm
75x75x60cm
100x80x70cm
120x100x100cm
Secondary Chamber
50L
110L
180L
280L
600L
Smoke Filter Chamber
Yes
Yes
Yes
Yes
Yes
Feed Mode
Manual
Manual
Manual
Manual
Manual
Voltage
220V
220V
220V
220V
220V
Power
0.5Kw
0.5Kw
0.5Kw
0.7Kw
0.7Kw
Oil Consumption (kg/hour)
5.4–12.6
7.8–16.3
10.2–20
12.1–24
14–28
Gas Consumption (m3/hour)
6.2–11.4
8–15.7
9.8–20
9.9–26.1
10–32.2
Temperature Monitor
Yes
Yes
Yes
Yes
Yes
Temperature Protection
Yes
Yes
Yes
Yes
Yes
Oil Tank
100L
100L
100L
100L
200L
Feed Door
30x30cm
45x40cm
55x50cm
70x55cm
80x60cm
Chimney
3Meter
3Meter
5Meter
5Meter
10Meter
Chimney Type
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
1st. Chamber Temperature
800℃–1000℃
800℃–1000℃
800℃–1000℃
800℃–1000℃
800℃–1000℃
2nd. Chamber Temperature
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
Residency Time
2.0 Sec.
2.0 Sec.
2.0 Sec.
2.0 Sec.
2.0 Sec.
Gross Weight
1500kg
2200kg
3000kg
4500kg
6000kg
External Dimensions
140x90x120cm
160x110x130cm
175x120x140cm
230x130x155cm
260x150x180cm
Equipment Double chamber medical infectious waste incinerator Capacity 10-30 kg per hour Characteristics of waste Mainly syringes and needles from immunization routine and campaign activities. However, the following average characteristics are considered*: heating value above 2000 kcal/kg (8370 kJ/kg); content of combustible matter above 60%; content of non combustible solids below 5%; content of non-combustible fines below 20%; moisture content below 30% by weight Combustion performance: The medica waste incinerator shall be capable of reducing waste to ash not exceeding 10% of the total combustible charges. Outdoor installation. The medical waste incinerator will be installed outdoors.All incinerator components shall be suitable for but not limited to outdoor shaded installation, including electric motors, be resistent to corrosion, moisture and related weather elements.
Products of building and construction: The incinerator will not have any asbestos, asbestos-containing materials, mercury thermostats, as well as mercury switches. Refractory materials will be able to meet appropriate standards under ISO TC33 and also CEN/TC 187.
Kinds of incinerator design acceptable: Dual-chamber controlled air incinerator or dual- chamber pyrolytic incinerator
Medical waste is posing a growing problem all over the world, jeopardizing the health of staff, patients, disposal workers and anyone else coming into contact with the often hazardous materials discarded by hospitals and other healthcare sites. Hospital waste varies from site to site and the biggest challenge is to dispose of this wide range of waste streams. Incineration is still the preferred way to process medical waste without endangering the heath patients, staff or anyone else coming into contact with them. Clinical waste is costing more and more to dispose of safely. Health Clinics and Health center can now handle their own waste streams using one of our specialist medical incinerators. Destroying hazardous waste at source is by far the most effective and efficient way of handling waste that could potentially spread diseases or viruses.
Standard 20% -25% of the complete waste generated by medical care facilities is related to as hazardous and may create a selection of health as well as environmental dangers if not handled and damaged in an proper way. With years worth of experience in this sector, our clinical array of burners are made to provide for the economical needs of tiny facilities to the more demanding and also specialized requirements of big medical facilities in their waste monitoring processes.
HICLOVER is now offering a full range of medical waste incinerators, designed to provide efficient waste destruction, utilizing best available technologies and environmentally friendly process. Due to the secondary chamber with its 2 second retention period, our medical incinerator range is well suited to process medical waste.
Our products make sure reliable, tidy as well as easy disposal of medical waste is possible. The incineration of clinical waste including pathological waste ( red bag waste), Biohazards & & Sharps, General Medical Waste, from Hospitals, Study Center, Drug Companies , Drug Produces, Main Treatment Trusts, Aesthetic Surgical Procedure Centers, Nursing Residences, Care Homes and other Medical Waste.
● Service before and also after Setup — — Manufacturing facility training for installment, operational and also upkeep with totally free expense.— — Online solution support for installment, operational as well as maintenance with complimentary cost.— — Onsite installation , operational and maintenance training — Onsite solution assistance after setup
● Spare components supportHICLOVER currently uses extra parts including: — Burners( diesel oil, LPG or gas) — Element for burners — Fire ropes — Burner chamber upkeep materials — Air Fan — Temperature level aspect — Smoke filter block — Control box — Other components
Nanjing Clover Medical Technology Co., Ltd.
Tel: +86 -25 -8461 0201 Fax: +86 -25 -8461 0406
Web site : www.hiclover.com Email— : [email safeguarded] Email: [email protected]