Tag: wasteincinerators

medical waste diesel incinerator


medical waste diesel heater Burning Cost:47.5–– – – 50kg/hour.
Minimum Operating Temperature level:850 o C( key combustion).
Optimum Operating Temperature level:1450 oC( Afterburner chamber).
Second Burning Capacity: Compulsory.
Thickness Insulation:20 mm High.
Refractory Casting: Minimum 65mm.
Strong refracting lining to hold up against:1500 oC.
Regular burn out time: optimum:3 humans resources.
Fuel type: Diesel.
Gas Consumption in L/hr:7.5 to 9.
Home time in additional chamber:2 sec.
Residue ash article 100kg: Max 3.8 kg.
Gizmo for safeguarding versus communicable spatter and/or cross-contamination by securely disinfecting needles, rings, and more by infrared warmth.
Electric characteristics.
1) A 120V, 60Hz mono-phase electrical source with line connection plug NEMA 5-15 kind.
2) Defenses versus over-voltage and over-current line problems.
3) Conformity with relevant Haitian standards as well as regulations.

Operational qualities.
4) Quick complete sanitation in around 5-7 s.
5) Completely separated quartz/ceramic tube, to give safety and security for the person (no open flame).
6) Operating temperature level around 820 ° C.
7) Placed on a steady base, as per instance listed below.


waste heater suppliers from china


Incinerate: medical waste as well as additionally basic waste Capability to melt waste:
400-500kg/ human resources.
Gas: Diesel.
Gas Consumption: 10 liters/hr optimum.
Incineration temperature: 950-1300 levels centigrade.
Case: thick (mins 5mm) stainless-steel covering as well as absolutely safeguarded to.
stand up versus sea humidity Voltage 220/240v or 380/415V Uniformity 50Hz.
high-capacity, powerful, European Requirement heater, ideal for high quantity incineration, with indispensable after-burner for higher performance in addition to exhausts manage.
Waste Type as well as Melt Rate.
Made specifically for usage by fowl farmers,.
lamb farm owners, abbatoirs along with for pet dog.
cremation. The heater will certainly lose approximately 50kg of.
waste per hour (as long as 150kg shed.
Building and construction.
Light steel bonded construction having sheet steel.
As structural area sustains.
Cellular cellular lining.
Monolithic premium quality refractory concrete with high grade insulation support.
Heating units.
Absolutely automated, high-efficiency burners with electronic ignition, flame recommendation as well as burning control devices fitted.
Packing– – Ash elimination.
Hands-on ash removal from the key chamber. (Ash doors are readily offered as needed).
Outside finishing.
Multi-coat premium quality, high-temperature aluminium enamel leading layer paint, finished in silver.
Control.
Completely automated sequential control given by interior.
waste heater manufacturers from china, PLC system providing control of:.
1. Extra chamber pre-heat.
2. Lost cycle (variable).
3. Great cycle.
Fuel Options.
Diesel, LPG, Natural or Biography Gas.
Regular Gas Intake.
Diesel: 8/ 10 litres per hr.
Fluid Gas Gas: 6/ 8 litres per hr.
Gas: 7/ 9 Nm3 per hour.
Electrical supply.
240volt 16 amp.
Secret Requirements.
Chamber Amount 2.38 m3:.
2.2 m (l) x 0.9 m( w) x 1.2 m( h).
Lots Capability approximately 1000kg.
Heaps Technique Top. · Kind: Pyrolytic

· Usage: For medicines

· With Chassis to be Placed in truck/lorry

· May have a main along with added combustion chamber

· Should have a dilution chamber

· Capability: 100 Kgs per hr

· Resource Of Power: Diesel or Natural Gas or Liquified Gas


hospital incinerator manufacturers

The Incinerator Plant is output wastes incineration from Different petrochemical units. In this project we want to incinerate all output wastes from petrochemical units and also produced high pressure steam from incinerator plant heat generated.
At first output waste from petrochemical collects and transfers to transit and sorting center in various forms. Input feeds of incinerator plant are shown in below table:

hospital incinerator manufacturers, Waste streams of petrochemical unit collect and store in Transit and Sorting Center.
In Transit and Sorting Center one laboratory must be considered.
In this center, waste will be classified in two groups:
–    Unsuitable for burning
–    Suitable for burning
Unsuitable waste for burning can be divided into the 4 categories:
–    Buried materials
–    Materials (wastes) that need to be stabilized before buried
–    Materials (wastes) that can be sold.
–    Wastes that can be returned to petrochemical.
Suitable wastes are classified into the two categories:
–    Input wastes to rotary kiln, consist of solids and waste fluids.
–    Input wastes to static kiln, consist of clean fluids and gasses.
All solid wastes must be transferred to storage pit from Transit and Sorting Center. Solid wastes storage pit is input of rotary kiln.
All fluid wastes must be stored and stabilized in Transit and Sorting Center. All storage and stabilization devices or facility must be considered. Storage and stabilization devices (facility) consist of:
Tanks, Pumps (Transfer, Loading & Unloading), Agitator (Mixer), Blanketing System, Flare system, Instrumentation and Control Systems, etc
Storage and stabilization capacity must be considered based on worst case (shut down).
Generally incinerator plant consists of two similar trains (capacity of each train is 100%). Each train consists of a rotary kiln and a static kiln.

burner for professional waste


MINIMUM CRITERIA FOR ENGINE OF INCINERATION
CAPACITY OF INCINERATION 30KG/ H

1. BASIC SPECS:

The burner for clinical waste need to be designated for the damages of all sort of waste created by the Facility for Health (waste type medical facility, center, medical lab for ruining ability of 30kg/ h).

Pyrolytic gasification combustion control shall:

? Protect against advancement of black smoke as well as also dirt development point loading of waste;
? Supply normal and complete burning of the waste;
? Provide controlled assuring the absence of color, cloud of smoke or shedding smell;
? Allow limited gas intake

The incinerator with pyrolytic combustion have to have:

a. Combustor:

– – – – Chamber solid steel assistance legs sheet;
– – – – The cellular lining is made from refractory blocks as well as likewise a thermal insulation making sure a minimum temperature of the sheet;
– – – – The sole burning is comprised of a refractory lining particularly created to satisfy the thermal, mechanical in addition to corrosive fluid waste needs and liquified glass;
– – – – The dimensions of the floor are prepared laterally primary air nozzles that sustain burning;
– – – – The fireplace is outfitted with a blending system of waste burning is regulated button;
– – – – The recovery procedure of the ashes will certainly take place daily line before starting the day’s procedure.

Framework of the refractory cellular lining:
* Insulation:
– – – – Operating temperature degree: 1000 ° C max
– – – – Nature: Calcium Silicate – – – Thickness: 80 mm * Refractory: – – – Running temperature: 1650 ° C max – – – Nature: Refractory blocks with 42 alumina – – Density: 110mm

Heater burning:

– – The burning chamber is geared up with a heater to line to make certain right temperature degree for the general damages of waste burning; – – Automatic monobloc burner and also fire dive provided with an electronic ignition system and likewise irreversible air circulation. Air follower: – – A major air and also second air follower gives the needed oxygen shipment – – There is an electrical motor ran shutoff that regulates the blood circulation according to the combustion. – – The stress and anxiety of the fan is 500 mm CE to pierce the mass of – waste throughout burning.

b. Article – – burning chamber:

– Manage the gas has a marginal temperature degree of 1100 ° C with a minimal residence time of 2 secs the afterburner is to; – – An additional air injection is expected in addition to offers best oxygen material; – – The heater ensures a minimum temperature of 1100 ° C continuous; – – The design of this heating system looks like shedding burners; – – The afterburner is – outfitted with accessibility doors in order to ensure typical cleansing– – of dust; – The afterburner is lined with high thermal insulation with a density of 150 mm

c. Closet, control and likewise guideline: – – The entire installation will certainly adapt European criteria( EU ). – – The electrical power is 220V 50Hz singular phase. – – Regulatory authorities of temperature with digital display screen:.
––? 1 to take care of the temperature level of the burning chamber.? 1 for regulating the temperature level of the afterburner.
? The hands-on controls are supplied on each thing.

2. PRODUCT DIMENSIONS

Recap Dimensions. Gas diesel oil.
Amount of combustion

chamber Burning: 0.3 m3.
‘ TEMPERATURE LEVEL LEVELS:. Burning. Afterburner

0.11 KW.
0.11 KW0

Follower power 0.37 kW


small medical waste incinerator

i- burners:

use diesel , natural gas , liquefied petroleum gases according to standards burners should have main vent to be used

for protection.

2- materials:

-the chamber should be covered from inside with refractory brick with thickness 22 cm aluminum silicate insulation 11cm

thickness with the ability to change this layer .

– All surfaces made of carbon steel should be surface treated and covered with primary layer. That holds the working

condition and easy to clean it is recommended that materials are chosen according to standard codes.

Chimney exhaust gas filtration:

To meet the European standard 2000/76/EC

Chimney height should not be less than 12 meter and radius 8 cm.

 

– Treat the gas has a minimum temperature of 1100 ° C with a minimum residence time of two seconds the afterburner is

to;

– A secondary air injection is expected and provides perfect oxygen content;

– The burner ensures a minimum temperature of 1100 ° C continuous;

– The design of this burner is similar to combustion burners;

– The afterburner is equipped with access doors in order to ensure regular cleaning of dust;

– The afterburner is lined with high thermal insulation with a thickness of 150 mm

 

  1. Cabinet, control and regulation:

– The entire installation will conform to European standards (EU)

– The electrical power is 220V 50Hz single phase.

– Regulators of temperature with digital display:

? 1 to regulate the temperature of the combustion chamber

? 1 for controlling the temperature of the afterburner

? The manual controls are provided on each item.

  1. Should have preparation, Incineration, Scrubber steps to burn waste completely and waste gas should be non-

polluted

 

  1. Heavy duty steel, heat resistant coating, stainless steel lid, painted tubular steel frame, 2-blowers, axial

vane, suitable drum (S/S, thick) for the incinerator must be provided.

 

  1. Approx. 20 to 25 Kg per batch and the time required for 1 batch not more than 1 hour on average.

tiny range scientific waste burner


Hazardous as well as likewise hazardous wastes,
Medical pharmaceutical along with pleasant fluids Wastes
Residential trash
Electric as well as electronic wastes
Hazardous waste
Generally, all kind of wastes and also rubbishes
Ability 50-60Kg/ h

Combustion sustaining materials
Coal oil, diesel oil

Temperature degree inside
800-10000C

1000-12000C

Burning performance
> 98%

Power intake
1.3 KW

Sound
< 78dB

Index of let smoke as well as waste gas
Ringelman’s smoke index < level 1

Smoke focus
Oil
45.5

( mg/m3 ).
Gas.
25.5

( mg/m3 )

SO.
Oil.
0.176.
Gas.
0.065

NOX.
Oil.
0.031.
Gas.
0.038

H2S.
Oil.
0.016.
Gas.
0.008

CO
.
Oil. 8.32.
Gas.
35.64

tiny scale clinical waste burner Demands.
Additionally eruptive as well as fireproof products not confessed

Refine way.
2 shedding storage rooms (wetness drying, warm dirt elimination)

Burning/ Heater.
Top quality made in Italy

Blower.
High quality made in China

Control Electrical.
High quality made in China

Ability 50 Kg/h

Performance Voltage.
220 V

Power.
1000 W

Applied For.
200 beds

Input Style.
Hands-on

Medical Burner, 24 kg/hr.
Clinical Heater, 24 kg/hr including panel board, regulates in addition to accessories.
Heating unit entry.
Chimney.
Blower.
Combustion heater

Medical Incinerator, 12 kg/hr.
Medical Heater, 12 kg/hr including panel board, controls as well as also devices.
Heater portal.
Smokeshaft.
Blower.
Burning burner

Medical Incinerator, 6 kg/hr.
Clinical Heater, 6 kg/hr including panel board, regulates in addition to tools.
Heater entrance.
Chimney.
Blower.
Burning heating unit


DROPPING AND ALSO INCINERATION OF SOLID WASTE

Biomedical Waste Any type of type of fluid or strong waste which may supply a danger of infection to individuals consisting of non-liquid tissue, body parts, blood or blood products as well as body fluids, research laboratory and also veterinary waste which includes human disease- setting off representatives, as well as disposed of sharps (i.e. syringes, needles, scalpel blades).

Base Ash The program likewise unburned and non-combustible product which remains at the shed site after burning is complete. This consists of products remaining to remain in the melt chamber, exhaust piping as well as air pollution control tools where such tools are utilized.

Burn Box A significant metal box used to lose solid waste. Burning air is commonly offered passively by means of openings or vents cut above lowest level of bundle. An exhaust pipeline or pile might or might not be attached.

Industrial Camp A short-term, seasonal or multi-year center with a capability greater than 15 individuals as well as likewise which has in fact been established for research study, commercial or business purposes. An industrial camp does not contain a standard camp or area camp.

Commissioner’s Land Lands that have in fact been relocated by Order-in-Council to the Federal Government of Nunavut. This consists of roads as well as land subject to block land transfers. The majority of Commissioner’s Land is located within districts.

Contamination Any kind of sound, heat, substance or vibration and also includes such numerous other substance as the Priest could prescribe that, where launched right into the ambience,

  • endangers the health, safety or welfare of persons,
  • interferes or is likely to interfere with the normal enjoyment of life or property,
  • endangers the health of animal life, or
  • causes or is likely to cause damage to plant life or to propert

Developed Initiative The reoccuring examination of possibilities for declines as well as the application of adjustments or discharge control upgrades that are practically and also financially useful along with which lead to on-going reductions in exhausts. Identified campaigns consist of the growth and execution of waste management preparation which is concentrated on air contamination avoidance.

De Novo Synthesis The manufacturing of complicated particles from easy particles.

Setting The aspects of the World as well as includes

  • air, land and water,
  • all layers of the atmosphere,
  • all organic and inorganic matter and living organisms, and
  • the interacting natural systems that include components referred to in paragraphs (a) to (c) above.

Field Camp A temporary, seasonal or multi-year facility consisting of outdoors tents or various other comparable short-term frameworks with a capacity of 15 people or less as well as which has been developed for research study, business or commercial objectives. An area camp does not consist of a traditional camp or industrial camp.

Fly Ash Unburned product that is sent right into the air in the type of smoke or excellent bit concern throughout the burning procedure.

Hazardous Waste An impurity that is a hazardous great and is no longer wanted or is pointless for its preliminary assigned purpose as well as additionally is intended for storage area, reusing, therapy or disposal.

Incineration A treatment technology including the damage of waste by regulated burning at heats.

Incinerator A gadget or framework intended primarily to blaze waste for the function of decreasing its volume, ruining a dangerous product in the waste or wrecking an infectious product in the waste. A heater has suggests to control the burning as well as air circulation processes.

Assessor A specific appointed under subsection 3( 2) of the Environmental Protection Act as well as likewise contains the Principal Ecological management Policeman.

Changed Burn Barrel A metal drum taken advantage of to shed waste that has been secured with gadgets or functions which supply minimal boosted warm generation, warm retention in addition to holding time.

Open up Burning of waste with restricted or no control of the melt treatment. For clearness, open burning consists of shedding on the open ground or utilizing a thaw box or altered or unmodified melt barrel.

Certified Person An individual that has a proper level of experience and also experience in all essential aspects of waste management.

Accountable Party The owner or person in charge, administration or control of the waste.

Smoke The gases, bit issue in addition to all other items of combustion generated right into the setting when a compound or product is thawed consisting of dirt, triggers, ash, residue, cinders and also fumes.

Strong Waste Unwanted strong products discarded from a residence (i.e. single or many building residences, various other comparable irreversible or short-lived homes), institutional (i.e. institutions, government centers, healthcare facilities in addition to health and wellness and health centres), organization (i.e. shops, eating facilities) or commercial (i.e. mineral, oil as well as gas exploration and growth) facility. For quality, solid waste does not contain biomedical waste, hazardous waste or sewage sludge.

Typical Camp A seasonal or brief camp used primarily for camping, searching, angling or various other regular or social jobs. A regular camp does not include a field camp or commercial camp.

Unmodified Burn Barrel A steel drum made use of to shed waste that has not been attached with tools or functions which offer enhanced warm generation, warmth retention along with holding time.

Ignored Timber Hardwood that has actually not been chemically fertilized, repainted or likewise altered to increase resistance to pests or weathering.

Waste Audit A supply or study of the quantity in addition to type of waste that is generated at an area.

incinerator manufacturers china

  1. Ash should be only 5% of the waste material

 

  1. Weight of Incinerator – 50-60 Kg

Municipal incinerators with a 10-metric ton/24-hour capacity, complete with Stacks, control panels and all accessories,

complying with 01015 par. 5.16.1

LOT

2.0

 

Medical incinerator with a 10 kg/hour (15 lbs/hour) capacity shall be constructed on the site, complete with Stacks,

control panels and all accessories

 

 

  1. 220V AC

 

  1. Surgical , medical & laboratory waste

 

 

  1. PRODUCT DIMENSIONS

 

Description   Dimensions

Destructive capacity  30 Kg / hour

Operation     12h/24, 6d / 7

Fuel       diesel oil

Chimney       Height: 5m, Diameter: 280mm

Volume of combustion

 

chamber Combustion: 0.3 m3

Post combustion: 0.2m3

Mixed combustion chamber: 0.3m3

` TEMPERATURES:

. Combustion

. Afterburner

900 ° C

1100 ° C

POWER BURNER

Combustion

Afterburner

 

0.11 KW

0.11 KW0

 

Fan power    0.37 kW

hiclover burner 100-150kgs per hour


Version

YD-100

Photo

Burning Price

100-150 kgs/hour

Trick Burning Chamber

2000 Liters

Secondly Combustion Chamber

500 Liters

Feed Establishing

Handbook

Voltage

220V/380V

Power

2.5 Kw

Gas Kind

Diesel Oil

Heating Unit

Italy Original

Oil Intake (Diesel Oil)

Average 28 kg/hour

Gas Use (Gas)

***

Inner Measurements

180x115x98 centimeters (key chamber)

Outside Measurements

270x185x280cm (without chimney)

Temperature Level Present

Yes

Oil Tank Capability( if oil gas)

200 Liters

Door Opening

55 x 80cm

Chimney Size

6.0 Meters

Smokeshaft Kind

Steel

Equipment Gross Weight

9000 kgs

Treatment Technical Specs

Primary Chamber Temperature Level

800 ℃–– – – -1000 ℃

Second Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98%

Waste Lower Calorific Power

3500Kcal


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22


Biomedical Waste Heater, 10-15 KG.


The first is a small
20kg/per hr incinerator for a small-medium sized hospital, and the
second is a 500kg per/hr incinerator for a company planning to start a
incineration service in Lahore.Burn Rate : >200 kg per hour
Average fuel consumption : ~29 kg per hour ( Or lesser)
Gas Retention in Secondary Chamber : 2 secs
Temperature Monitoring : Yes
Average Ash Residue : 3%Medical waste management practises here are sub-standard. I have come across your small scale medical waste management units.Biomedical Waste Incinerator, 10-15 kg
Manufacturer:
Brand:
Type / Model:
Country of Origin:
Description of Function
The Biomedical Waste Incinerator is used for Incineration of each type of Biomedical Waste.
The Disposal of such Biomedical waste is a very important as it is a dangerous wastes for
human life, and It is only possible with a perfect incinerator.
Operational Requirements
It shall be operated by manual and automated mode.
The combustion efficiency (CE) shall be at least 99.00%.
The combustion efficiency is computed as follows:
C.E.= __%CO2______ x 100
%CO2 + %CO
Emission Standards: Lower emission rates are preferred.
Parameters                   Concentration in mg/Nm3 (12% CO2 correction
Max total dust              30mg/m3
Max Sulphur Dioxide      200mg/m3
Max Nitrogen dioxide    400mg/m3
Max Carbon                     100mg/m3
Monoxide
Minimum stack height shall be 30 metres above ground.
Volatile organic compounds in ash shall not be more than 0.01%.
System Configuration
Biomedical Waste Incinerator, complete unit.
Technical Specifications
Incinerator:
It shall be Electrical or Diesel Fired Incinerator or Controlled Air & pyrolytic.
Type of Waste: Biomedical Waste
It shall have burning capacity 10-15 kg/hr.
Fuel: Diesel
Burner: Monoblock fully automatic burners.
Temperature: Primary Chamber 800 ± 50 oC, Secondary Chamber 1050 ± 50 oC.
Type of Waste: Biomedical waste with moisture content up to 85%.
Destruction Efficiency: 99%.
It shall have separate digital display of temperature for both chambers.
It shall have provision for measuring primary & secondary chamber temperatures using external
thermo coupler.
Secondary chamber gas residence time shall be minimum 1 second at 1050 oC.
Primary Chamber:
Type: Static Solid Hearth
Material of Construction: Mild Steel, 5mm thick
Refractory thickness: approx.115mm thick
Material: Refractory bricks confirming to international standard.
Temperature resistance: 1400 oC
Insulation thickness: approx.115mm thick
Material: Insulation bricks confirming to international standard.
Waste Charging: Manual & Automatic waste charging.
Ash Removal: Manual/automatic
Secondary Chamber:
Type : Static Solid Hearth
Material of Construction: Mild Steel, 5mm thick
Refractory thickness: approx.115mm thick
Material: Refractory bricks confirming to international standard.
Temperature resistance: 1400 oC.
Insulation thickness: approx.115mm
Material: Insulation bricks confirming to international standard.
Waste Charging: Manual & Automatic waste charging.
Emergency Stack:
Type: cylindrical, top mounted on venturi ejector.
Material of Construction: Mild Steel, 3mm thick.
Refractory: 75mm thick castable.
Insulation: 25mm thick castable.
Quencher:
Material of construction of outer body: Mild Steel refractory lined from inside.
Shall have water circulation system with centrifugal pump.
It shall have to reduce flue gas temperature before venturi scrubber.
Shall provide pump motor of suitable capacity.
Air Pollution Control Device – Venturi Scrubber
Type: High pressure jet type.
MOC: Stainless steel – 316L.
Temperature at the outlet: 78-80 oC
Scrubbing Media: Water with 5% caustic
Re- Circulation Pump for Venturi Scrubber
Type: Centrifugal
Application: PP/SS
Piping : PPR
Droplet Separator & Re-Circulation Tank (Integral)
Type: Cyclonic
Application: To separate water droplets from flue gases
Material of Construction: Mild Steel Rubber lined 3mm thick
I.D. Fan:
Type: High pressure centrifugal
Material of Construction: Stainless steel 304, impeller and mild steel rubber lined casting
Drive: Bel
Combustion Fan:
Type: Centrifugal
Modulation: Manual damper control
Material of Construction: Mild Steel
Drive: Direct drive
Burners:
No. of burners: 2 Nos. (1 No. in Primary Chamber and 1No. in Secondary Chamber)
Type: Monoblock fully automatic
Fuel: Diesel
Fuel Oil Storage Tank:
Shall provide suitable capacity of oil storage tank.
Material of Construction: Mild steel.
Facility for visual checking of fuel shall be there.
It shall have diesel consumption monitoring system.
It shall come with diesel oil level indicator, piping with valves & N.R. valve.
Control Panel:
Type: Manual & Automated PLC based control panel with printer & recording device.
Material of Construction: CRCA sheet
It shall have digital temperature controller.
Epoxy powder coated washable paint finish.
It shall have audio-visual alarm system.
Chimney of 30 meters Height:
Material of Construction: Mild Steel
It shall be self-supporting type.
Height shall be 30 meters from ground level.
Paint The chimney is painted externally with two coats of heat resistant aluminum paint
Shall provide ladder till the top.
It shall have 3mm thick rubber lining from inside for protection.
It shall come with aviation lamp, lightening arrestor, stack, drain, inspection platform, sampling
port.
Consumption certificate:
The bidder must submit diesel consumption for a daily operation of 6 hours.
Turnkey:
Prices offered shall be inclusive of all civil works, electrical requirements including cabling and
switches required for installation & commissioning of the equipment.
Bidder shall submit detail drawings, design, and layout plan of civil works.
The bidder shall submit the details of BOQ of civil and electrical works.
Accessories, spares and consumables
All standard accessories, consumables and parts required to operate the equipment, including
all standard tools and cleaning and lubrication materials, to be included in the offer. Bidders
must specify the quantity of every item included in their offer (including items not specified
above).
Operating Environment
The system offered shall be designed to store and to operate normally under the conditions of
the purchaser’s country. The conditions include Power Supply, Climate, Temperature,
Humidity, etc.
Power supply: 220-240 VAC, 50Hz single phase/400 – 420 VAC, 50Hz three phase as
appropriate fitted with appropriate plug. The power cable must be at least 3 meter in length.
Standards and Safety Requirements
It shall have approval of “Pollution Control Board” of purchaser’s country.
All mandatory approvals required for the installation and operation of incinerator shall be done
by the bidder.
Must submit ISO 9001 AND
CE or USFDA approved product certificate.
User Training
Must provide user training (including how to use and maintain the equipment).
Warranty
Comprehensive warranty for 2 years after acceptance.
Maintenance Service during Warranty Period
During the warranty period supplier must ensure preventive maintenance along with
corrective/breakdown maintenance whenever required.
Installation and Commissioning
The bidder must arrange for the equipment to be installed and commissioned by certified or
qualified personnel; any prerequisites for installation to be communicated to the purchaser in
advance, in detail.
Documentation
User (Operating) manual in English.
Service (Technical / Maintenance) manual in English
List of important spare parts and accessories with their part number and costing.
Certificate of calibration and inspection from factory.