Tag: wasteincinerators

pet burners up for sale


SMART ASH INCINERATORS FOR THE DISPOSAL OF HAZARDOUS WASTE
? Quantity: 20 systems
? The Burner collaborates with a 55 gallon open ended up steel drum
? The system operates without fuel as well as used just 120v or 220v electric power for the blowers
? Unit can melting oil contaminated waste and additionally medical wastes with a wetness material of 0 to 15%.
? Each device is offered with 2 steel drums, to make certain that an extra is conveniently available.
? Each unit to be given with suggested spare elements.
? Solution warranty– – minimum one year from billing as well as authorization.
? Individual’s guidebook to be supplied in French and also English

HAZARDOUS WASTE TO BE INCINERATED

Unsafe Strong Chemicals.
Various kind of combustible solids, taken advantage of fabrics, oil and printer toner cartridges, chemicals for water filtration and also image consumables, as well as plastic product, vacant steel/ plastic cans that still have deposits of hazardous items, oil absorptive

Risky Fluid Chemicals.
Primarily numerous kinds of Acid, Paint, Varnish, White Spirit, Aromatic-Less Solvents, Artificial Fluid For Brake Solutions, Airplane De-icing Liquid, Hydraulic And Likewise Compressor Oil, Freon made use of in some older refrigeration systems, Chemical Liquid/Spray, Air Refresh Spray and also various other comparable chemicals

Contaminated Gas.
Primarily diesel or gas infected by water or solvents

Made use of and/or Polluted Oil.
Utilized electrical motor oils and/or mineral oils unfit for their initially implied usage. Usually motor/gear box oil (approx. 80%) contaminated by a combination of white spirit and additionally acetone (approx. 5%) hydraulic liquid (approx 5%)

Polluted Water.
Waste oils/water, seeps, hydrocarbons/water combinations, solutions as well as likewise leachate

Infected Dirt.
Dirt polluted by oil gas of chemicals,.
Soil infected that needs to be reused in garbage dump,.
Dirt dealt with along with transformed on website

Oil Polluted Solids.
Fabrics, absorbents, cardboard, oil and also gas filters, air filters are not considered as dangerous products

Digital Waste.
Waste electric or digital setups or appliances up, including published circuit card having dangerous product and/or significant steel and/or releasing minimized radiation

Used Battery Cells.
Dry battery, ups battery or various other kinds unsorted waste batteries/battery cells, having items that are hazardous

Used Lead Acid Batteries.
Waste lead acid batteries, drained pipes/ un-drained as well as whole or wrecked

Hazardous Medical Waste.
Scientific along with associated waste arising from clinical, nursing or comparable techniques and also waste created in facilities throughout the examination or treatment of individuals (biography risk)

Finished Medicines Strong.
Waste medications, medicines along with drugs, consisting of delicate medicines

Ran out Medicines Fluid.
Waste liquid pharmaceuticals, different kind liquid chemicals for treatment, medical oil in addition to paraffin based finished drugs

Finished and/Or Infected Food.
Spoiled fresh food or meaningless recipe prepared to consume dishes (MRE’s) entirely dry food


hog incinerator

(B) Features and Specifications  of the Steam Boiler: Features of the Boiler:

  • It must be an Electrical boiler
  • Splash proof electric enclosure and switches
  • Door Isolator to main electric enclosure
  • Alarm lights and Safety/protection against excel pressure
  • Level control on feedback water tank

 

Technical Specification of the Boiler:

  • Output: between: 90-110 kg/h (F&A 100 deg C)
  • Working pressure : between 7-10 bar
  • Boiler water content : between 80-100 litre
  • Feed water take content : between 60-80 litre
  • Power consumption : between 60-75Kw
  • Number of Heating Elements: 3-4 nos.
  • Electrical requirements: 400Vac, 50 Hz, 3 ph

 

(C) Technical Specifications of Tab washer Features:

  • Fully automatic and manual modes.
  • Metal construction, SA 240/304
  • Sensors to maximize both machine efficiency and operator safety.
  • Must use Re-circulating cold wash water to minimize water consumption and operating costs
  • Disinfects all bin surfaces
  • Uses Powerful blow dryer to remove excess surface water
  • Must be compliant with all North American and EU regulations

 

Specification:

  • Tub washer able to wash bins of a suitable size, the norm being 38 g
  • Must have an water reservoir of capacity minimum: 225 litre
  • Perfectly suited for hospitals and clinics by processing up to min. 300 bins per hour.
  • Time to wash and dry one bin after loading approximately 30 secs.
  • Bins loading on wash station at a time — approximately 12 nos.
  • Overall length : approx 30.0 feet
  • Overall height : approx 8.0 feet
  • Overall width: between 3.0-3.5 feet
  • Height to Conveyer from ground: approx 3 feet.

 

Drive of the Tub washer:

  • Motor driven
  • Moto: Horsepower: approx 4.0 HP
  • Power: 220 vac, 1ph or 400 VAC, 3 ph or the suit customer needs

 

Bins to be included:

  • 200 nos with different color (based on the requirement of the hospital)

healthcare facility burner


Supply, arrangement and also screening of medical waste burner with an ability of 75 kg/ human resources gas (LPG) total amount with all devices and also as a result with the chimney based on the technical specs along with problems of public wellness
make a room for the burner that fit 3 burners as in thing 3.1.1 as well as affixed to the heater space waste store that match waste for a duration of 7 days as well as all the structures of boosted concrete with preparingg heater structure as well as also store with all the job of wiring, electric as well as illumination systems, water as well as likewise sanitation
supply incinerator structure in addition to the waste storeroom with a fire snuff out sprinkler system counts on the resource of the water from network of teh basic website, in addition to a fire alarm system consists of noticing systems for cozy, smoke as well as this system is related to the medical facility emergency situation alarm system systems
Supply, arrangement along with testing of the air circulation system of the burner room and additionally the stockroom with fans ROOF COVERING LEADING EXHAUET FANS supplying them with filters with high efficiency (HEPA FILTER trip to draw followers with taking the air modification price of 5 times per human resources with streams and additionally air needed grilles
Supply, arrangement, checking various conditioning system for waste database DUCTED SPLIT UNITES and capability sufficient to maintain the interior temperature level at 14 levels Celsius in summer season as well as winter season
Supply, setup, testing of the air conditioning store of shielded premade wall surfaces inside the waste space with an ability of 35 cubic meters to save the clinical waste at a temperature of no Celsius till losing consisting of the cooling device and also all accessories
RISKY wood.
play hardwood.
petroleum residual waste.
hydraulic hose system.
calcium hydroxide bags.
bags or wood boxes including cyanide.
medical waste.
filters.
pharmaceuticals.
NO HAZARDOUS sawdust.
plastic.
plastic as well as likewise textil awnings.
wood.
plastic bathtubs.
rubber.
hygienic waste.
EPPs.
plastic bags.
structure and also building and construction reoccuring.
infected dustcloths or towels.
plastic or packaging of food.
polyestirene recipes, glasses, spoon, fork, etc.Capacity burner medical waste to high burning temperature degree.
With an electric gizmo to shield the setting as well as with 2 combustion chambers furnished with burner or oil.
– – heater to lose big volume things of 70 centimeters.
discrepancy: Automatic Control System.
– – harmful ability from 20 to 30 kgs.
First-room/ Temperature level = 900 ° C combustion.
2nd space/ Temperature degree = 1200 ° c afterburner


nanjing clover incinerator price


Significant incinerators – – – – INDUSTRIAL INCINERATORS – – – specifications listed below.

2.) Measurement requirement for the heaters is 750 — — — — 850 kg ability

3.) The bum price require to be 80 LL 100 kg/ hour.

4) The key chamber shouId have an operating temperature level of 900 -1200 degree C.

5) The incinerator should despise a heat 2nd chamber along with 2 second gas
retention time at 850- 1150 degree C so that it appropriates for high risk materials.

6). The incinerator needs to have temperature degree surveillance and also thermostat control for simplicity of
procedure as well as also warranty of lower temperature to confirm ideal treatment.

7). The heater should can shedding any one of the contaminateds materials detailed in the
subsequent location.

8) The burner need to can burning diesel oil and additionally need to consist of a bigger gas
container (10-500 litres) as well as likewise generator (3 –– – – 40 kV) developed that can be carried on the trailer with the
incinerator to see to it that the device needs no exterior electrical power supply.

9.) The heater requires to be trailer installed to ensure that it is a po

Infected products to be Blazed

Hazardous strong chemical:

Various types of flammable solids, used fabrics, oil, along with toner cartridges, chemicals
for water filtration as well as picture consumables and also plastic item, vacant
plastic/metal containers that still have residue hazardous product, oil absorbing.

Damaging fluid chemical:

Normally different kinds. of Acid, Paint, Varnish, Acetone, White Spirit Aromatic-less
Solvents, Artificial Fluid for Break Solutions, Aircraft De-icing Fluid, Hydraulic as well as
Compressor oil, Freon, utilized in some older refrigeration systems, Pesticide liquid/spray, air
freshen spray and various other comparable chemicals.

Contaminated gas:
Primarily diesel or gasoline contaminated by water or solvents.

Used and/or Infected oil:

Taken advantage of electrical motor oils and/or mineral oils unfit for their originally meant use. Primarily electrical motor
as well as likewise transmission oil (approximately 80%) polluted by a mix of white spirit and likewise acetone (concerning 51%), hydraulic fluid (about 5%).

Contaminated water:

Waste oilshvater, seeps, hydrocarbons/water blends, services as well as also leachate.

Polluted dirt:

Soil infected by oil, gas or 11 chemicals.
Polluted soil polluted by chemicals that needs to be reused in land fill.
Contaminated dirt—— — — dealt with as well as changed on web site.

Oil Infected Solids
Cloths, Absorbents, Cardboard, oil and additionally gas filters, air filters are dismiss as unsafe materials.

Electronic waste:

Waste digital or electric house appliances or settings up, consisting of printed circuit card,
including toxic material and/or heavy metal and/or emitting low radiation.

Used battery cells:

Dry battery, UPS battery or other kinds, unsorted waste batteries/ battery cells, having
items that are hazardouy.

Used lead-acid batteries:
Waste lead-acid batteries, rained/un-drained, as well as whole or smashed.

Harmful clinical waste:

Expert as well as associated waste, arising from professional, nursing or similar methods and likewise waste
generated in facilities throughout the examination or therapy of individuals (biography threat).

Ran out medications, strong:

Waste medicines, medications and likewise medicines, containing delicate medicines.

Ended medications Iiquid:

Waste liquid pharmaceuticals, numerous kind liquid chemicals for treatment, clinical
oil, along with paraffin based xpired medications.

Ran out and/or contaminated fod:

Ruined fresh food or unusable MRE’s (Meal Ready for Consume – – – – completely dry food)

Onsite Training and also Assem Option for Industrial Incinerators

I. The prospective customers should includ 1a rate in their bargain for training in a central place (Goma or
Bukavu) approximately 15 workers in the procedure and maintenance of the
devices.

Smart Ash Incinerators

1. Size demand for the burners is that the gadget works together with a 55 gallon open ended up
steel drum.
2. The system ought to operate wit. no gas and also make use of just 120V or 220V electric energy for the blowers.
3. The system needs to can melting oil contaminated wastes as well as additionally clinical wastes with a moisture product of 0-15% J.
4. Each tool should certainly consist of 2 steel drums, to make sure that an extra drum is offered.

Spare Components Selection.
If there are any type of provider recommended extra components, that list in addition to price should certainly be consisted of as a choice in the bargain.


dual chamber burner


Waste calorific worth: 4000KCAL/KG
Moisture Web content: 10-25%.
Small Ability: 50Kg/Hour set load.
Additional Chamber: 2 Secs @ 850degrees C
The main burning chamber must make certain very little separation temperature degree is not much less than 850 degrees C.

INSULATION.
Calcium Silicate.
Restricting Constant solution restriction 1000 degrees C.
Density 25mm

THROUGHPUT.
50kg/hour at a tiny calorific worth of 4,000 kcal/kg as well as an average bulk density of 120kg/MCubed for standard waste as well as 160kg/MCubed for medical care waste.All type of chemicals substances (Biocides) that made use of for Oil procedure sites (water base Exploration, oil operating centers for the corrosion as well as additionally others: The circumstances of the biocides are “WS-36, HAI-85M, SOFT DRINK ASH, DSMA, MICRO MATRIX, CALCIUM CARBONATE PENALTY, BARAKLEAN, GILSONITE, MIXED WASTE DIRT CHEMICALS, ZINC CARBONATE, CAUSTIC SODA, ENVIROTHIN, BARAZAN D,. etc) in addition to the products are solid and fluid.

2. In regards to the quantity of dropping the waste, possibly 200 – – – – 500 kg per human resources.

3. Our Operational time can be in Day in addition to can be during the night.

4. Can you please provide me the expenditure of device operated with Diesel as well as Gas.The primary burning chamber is the major structure of the heater, produced from light steel plate as well as tensed with rolled steel areas. It is brought from the flooring degree on a substantial steel assistance framework. Internally the covering is lined with calcium silicate insulation and additionally a warm face combination of incredibly duty brickwork or high strength castable.
The vital burning chamber must see to it minimum departure temperature level is very little less than 850 ° C
. One Hands-on Lots Incinerator comprising:.
·???????? Guidebook Loading door.
·???????? Horizontal strong fire place, refractory lined main combustion chamber. Approximate dimensions 800 mm dimensions x 2100mm long.
·???????? Complete sized bulk load/ash elimination door.
·???????? 1 off diesel-fired ignition heater– – temperature level managed. ·???????? 1 off shedding air supply fan in addition to distribution system, automated control.
·???????? High capacity additional burning chamber with residence time very little less than 2 secs @ >> 850 ° C. ·???????? 1 off diesel-fired afterburner– – temperature handled.
·???????? Control board– – automated operation.
e????? Temperature level sign key as well as likewise second chambers 0-1200 ° C.
e????? Refractory lined flanged smokeshaft to an elevation of 10M over ground degree


animal cremation

Technical Specifications of External SHREDDER Controls:

  • Pre-programmed PLC controlled
  • Password activated and reversal history indication
  • Motor starter with overload protection
  • Automatic instantaneous stop on hard object in shredder bed
  • Automatic heavy cutting load reversal and re-try , up to three times
  • Control housing Nema type 12

 

Cutting Hardwires:

  • Chamber Dimensions(WxLxH): approx 33 c m x 38 cm x 25cm
  • Number of knives: Approx 18 or to suit customer needs
  • Knife Thickness: Approx 18mm or to suit customer needs
  • Knife Diameter: Approx 16cm or to suit customer needs
  • Tecth per Knife : minimum 3
  • Number of Shafts: 2 ie double shaft shredder

 

Drive of the shredder:

  • Must be motor driven
  • Motor Horsepower : approx, 10 HP
  • Motor RPM: minimum 1750
  • Speed Reduction: 60:1
  • Generated Torque; min 40 Nm or 350 lbs/in
  • Gearbox: should be parallel shaft
  • Shock protection: Rubber mount torque arm
  • Power : 220vac, 1ph or 400 VAC, 3 ph or suit customer needs

 

Ancillaries to be included:

  • Sherdder stand, fabricated from 3” sq. steel tube, standard height 30 inches
  • Shredder hopper , fabricated form 16 gauge steel, with optional switched hopper lid.

 

(E) Features & Technical Specification of Conveyer:

To carry processed waste from vessel to shredder

 

Control:

  • Motor starter overload protection
  • Control housing Nema Type 12
  • Safety pull stops along both sides of conveyor

 

Ancillaries:

  • Conveyor stand , fabricated from 2” sq. steel tube
  • Raised sidewalls fabricated form 16 gauge steel

 

dimension:

  • Over-all length: between 20-25 feet or appropriate length depending on the installation requirement.
  • Over-all width: between 24-30 inch
  • over-all (without including stand) : between 12-14 inch
  • Available inclines: 0-40 degrees

 

Belt:

  • Belt Speed: 75 fi/min
  • Dam spacing; approx, 16 inch

 

Drive:

  • Motor driven
  • Horsepower: Approx .075
  • Motor RPM: approx.60
  • Electrical power input: 220 vac. 1ph or 400 VAC, 3 ph or to suit customer needs.

 

(F) Technical Specification of tipper features:

  • It is to be designed to allow for easy bin positioning under the door to unload processed waste and easy

inaneuverapility for lifting and tipping the waste into the shredder hopper.

  • Equipment with 2 bins to accommodate processed waste loads to be loaded into the shredder and shredded waste to be

transported to the disposal bin.

  • Frame: Rugged heavy duty frame constructed of formed and welded steel formed and welded steel for extra strength.
  • Mast: Fabricated with channel steel for greater strength and dependability. Open structure design complete with

safety cage to offer greater visibility

  • Lifting Chains: Must be dual lifting chain of roller style & must meet safety factor at least 6:1
  • Hydraulic system: durable cylinder with a chrome plated ram and a relief valve for overload protection
  • Forks: Heavy duty approx 4.0” wide x 42” long fixed forks.
  • Platform; solid steel
  • Battery: A heavy duty 12 volt, 125 amps/hour industrial strength battery.
  • Overload protection plugs into any 220 VAC outlet.
  • Steering: A pallet truck style steer handle for steering and approx. 4” phenolic wheels with roller bearings located

in the straddle legs.

  • Brake: A hand controlled floor lock brake that secures the unit in place.

 

Specifications:

  • Load capacity; Approx 1500 lbs
  • load centre: Approx 24 inch
  • Raised fork height: to suit customer needs
  • Overall must height: to suit customer needs
  • Lowered height: minimum 4.0 inch
  • Fixed fork width: approx 7 inch
  • Fork length : approx 42 inch
  • Platform of approx.25”x25”
  • overall width approx 25 inch
  • castors: approx 5 inch phenolic
  • Front wheel : approx 4 inch phenolic

STRONG WASTE BURNER


Primary chamber – Consists of a monolithic high grade refractory concrete with high grade insulation backing, . Utilising a refractory hearth or equivalent for continuous ash removal.

Secondary Chamber – Consists of high density, low thermal mass refractory ceramic fibre with an innovative low emissivity protective coating. bio medical waste treatment plant ( Incineration )with panel.

SOLID WASTE INCINERATOR    Feeding Capacity:    200 to 220 Kg.
Burn Rate *    60 Kg / hr
Ingredients to be burned    Cotton, Rubber, PVC Sheets, PE Gloves, Oil, Plastic Bottles, Paper etc.
Chambers *    Dual Chamber.
1: Primary Controlled Air
2: Secondary Excess Air
Temperature Monitoring    Required
Temperature Control to Primary & Secondary Chambers    Required
System Status & Alarms    Required for all necessary parameters.
Fittings & Accessories    Complete Package is required ( Including Nozzles & Flanges etc.)
Installation Requirements.    As low as possible . Almost Plug & Play type.
Dimensional Sketch, Operation & Installation Manuals.    Required
Off – Gas System    Required
Heat Insulation    Required for indoor installation
Delivery    Karachi Sea Port – Pakistan

The details of Components of incinerator is as follows:
Component Name        Features                 Range.
Primary Chamber    Temperature Required*    800 – 1000 deg C.
Heating Source    Natural Gas

Secondary Chamber    Temperature *    1100 – 1300 deg. C
Heating Source    Natural Gas + Propane or Fuel Oil as an additional source
Off – Gas Residence Time     2 Seconds.
Refractory Material    Material *    Alumina ( 56 – 80 % Pure )
Lining *    SS 316L
Life Span *    10 – 15 years.
Rating Temperature    1600 – 1800 deg. C
Media    Slightly acidic
Insulation    Material    Ceramic Fiber
Thickness    25 “ minimum
Feeding & Ash Removing     System    Air Tight ventilating locked doors ( Feeding from Top will be preferred)
Spares    Required for 5 Years trouble free operation


infectious waste pyrolysis machine chinalarge animal incinerators

Major components are – Ethanol, Paraffin, Silicon, Aluminium chloro hydrate, Bentone ,LPG

quote for incinerators for industrial chemical wastes treatment,

1 burning rate must be Average 30kgs/h
2 inside of chamber material must be refractory concrete cement
3 it works in three system diesel oil/ Natural gas or LPG
4 voltage must be 220V

5 inside temperature first must be 1000c  and second must be 1200c
6 pipe length must be 20 M

Our requirements are  for 125 kg/hr and 42 kg/hr, please send quote with catalog for both options
We are currently dealing in Defense Related Equipment, Construction Assistance and Medical Equipment, Modular Solutions

for Hospitals, Waste Management System, CSSD, Hospital Furniture and Services. We are based in the Capital city of

Pakistan i.e. Islamabad ,where there are all the head offices of Military and Govt. institutions. We have the capacity to

Participate in tenders and we also have a strong network of energetic/active dealers and sales staff in Pakistan and

Afghanistan.
5 incinerator 15 kg the specifications High temperature incinerator​99% combustion efficiency Temperature up to 1200°C or

Smoke and smell free Excellent heat retention Electric powered​ Fast heatup times Temperature Up to 1200°C or as required

Capacity​15 Kg Burning Efficiency 98% Noise- <78db Power – Electric Chamber​Single / Dual chamber Safety Alarm Emergency

vent Monitoring device​ Air Pollution Control Device​ CE and ISO Certified

I ‘d like to ask you about a power plant by burning waste. We have many of camps for displaced people in Syria, and we