Tag: wasteincinerators

a pet cremator

an animal cremator for our organization in malaysia.currently we are doing specific personal cremation as well as mass cremation for animals in addition to clinical waste.a burner which can shedding between 3 to 5 tonnes daily of mixed waste items, plastics, rubber, combustible putrescible waste, clinical waste, rubber tyres, paper as well as cardboard, fabrics, eco-friendly timber waste etc. As a few of the waste products will contain non-flammable solids, the burner should be capable of removing those materials possibly using a rotating kiln procedure.

It is not intended to utilize any kind of gas, such as oil or diesel, to advertise the burning of the waste, as the waste products are needed to be incinerated making use of a free burning procedure. Warm air nevertheless from a downstream procedure will be offered to enhance the burner temperature level and burning rate as needed. Very heats in the incinerator are not needed and are not called for.

The burning of the waste products is expected to create hazardous discharges which will be cleaned up by means of other existing downstream procedures and also an Article Burning process in the burner is as a result not required.

The burner must be capable of suiting an automated waste feed process.Incinerator Requirements

S. No.
Summary

1
Feeding Ability
100 Kg.

2
Burning Capacity
50 Kg./ Hour

3
Feed Setting
Hands-on

4
Gas
Diesel Oil

5
Incinerator Kind
Double Burning Chamber with Integrated In Smoke Filter (Dry Scrubber)

6
Smokeshaft Product
Non Corrosive/ Rust Resistant Ideally Stainless for longer Life (Height 5-7 Meter)

7
Burners
Premium Quality European CE Qualified Oil Burner

8
Control board
Standard PLC Control Panel

9
Power Supply
220/380 Volt A/c 50 Hz.

10
Oil Tank Capability
200 ~ ~ 300 Litre

11
Burning Chamber
Fire Brick, Refractoy Block, Concrete

BIOHAZARD DISPOSAL INCINERATOR CONTAINERISED IN A 20 FEET CONTAINER

BIOHAZARD DISPOSAL: CONTAINER

GENERAL INCINERATOR, IDEAL FOR INCINERATION OF VARIOUS TYPES OF WASTE, TOTALLY CONTAINERISED IN A 20 FT CONTAINER, TO CONSIST OF BUILT-IN FUEL CONTAINER As Well As GENERATOR.

TECHNOLOGICAL SPECS: BURNING CHAMBER QUANTITY (M3); 0.54 m3. SUGGESTED SET SIZE: 60 KG, BURN PRICE: 69 KG PER HOUR, AVERAGE GAS CONSUMPTION 13 KG PER HOUR, OPERATIONAL TEMPERATURE: 950-1320 CELSIUS, GAS RETENTION IN SECONDARY CHAMBER 0.5 SECS, WITH TEMPERATURE. TRACKING, AVERAGE ASH DEPOSIT: 3%, THERMOSTATIC TOOL: YES,
MEASUREMENTS: OUTSIDE LENGTH (mm): 1520MM, EXTERNAL SIZE (mm): 920MM, EXTERNAL HEIGHT (mm): 4020 MM
1. Burner for Bio-Medical Waste incineration needed
2. 50 kg/hr
3. 2 chambers have to exist
4. temperature level of primary chamber ought to be 850 degrees Celsius
temperature level of additional chamber should be 1200 degrees Celsius

install a diesel fired burner

blaze mostly pharmaceuticals (all kinds of dosage kinds … … syrups, tablets, injectables) medical consummabables, as well as likewise biological fluids …….
Capacity around 10 kg/ hour. install a diesel discharged incinerator that can accommodate a set tons of approximately 100 kg with a day-to-day burning need of up to 500kg per 8 hour day. Industrial Incinerator to damage.
the pharmaceuticals waste like Alu, PVC, PVDC etc.Installation for burning of pet waste price, existence, payment terms where it is possible to purchase in Russia? I am aiming to for capacity in between 200 -400 kg.
1.2 FIELD PAINT.
Perform painting required for surface areas not otherwise specified, and also surface paint of items only keyed at the factory

1.3 AREA TRAINING.
a. Submit [6] full duplicates of operating instructions laying out the detailed procedures needed for system startup, operation and also shutdown. Consist of in instructions the supplier’s name, version number, service manual, components listing, as well as quick summary of all devices as well as their standard operating features. And also [Six] total copies of maintenance instructions providing regular upkeep treatments, possible breakdowns and also repair services, repairing guides, as well as streamlined schematic representations for the system as set up.

3.6. Efficiency.
Preheat the incinerator for 4 hrs to reach the firing temperature of 982degrees C [1800] levels F. Weigh and tape the overall fee weight. Charge the burner at the ranked burning capability in kg pounds per hour for a duration of [4] hrs as well as run according to the maker’s written guidelines. Consist of in efficiency testing the procedure of the mechanical billing centers, the incinerator, the air contamination control tools, the ash.
handling devices, and the procedure surveillance facilities. Execute testing complete scale for a full- operation cycle, and also monitor performance to verify compliance with the agreement needs submit a record on surveillance results. Decrease the waste to a great ash deposit. Comply with typical burnout treatment. After the incinerator has actually cooled down, consider the residue. The weight of the residue will not go beyond 5.0 percent combustible material of the overall fee weight.
After clean-out, the incinerator will disappoint any type of evidence of wear and tear, such as shagged or spilling refractory, warping of parts, as well as stained exterior paint.

– Control.
Test the incinerator under real firing problems. Validate with screening that all controls operate within the optimum as well as minimum limitations for temperature or timing. Simulate real risky problems such as heats and also fire failure by lowering the setups for the activation of limitation and security controls.

– Covering Temperature.
Operate the incinerator under normal lots problems for not less than 6 hours. After 6 hrs, temperature readings of the external covering, taken at not much less than 5 arbitrary places, will not exceed the temperature level constraint of paragraph furnace building.
– – capability: 300-400 kg/hour.
– – Fuel syetem: Double gas( both oil and also gas)

50 to 60kg/hr as well as 100 to 120kg/hr diesel powered incinerator

50 to 60kg/hr and 100 to 120kg/hr diesel powered burner.1. Ability to Incinerate the Complying With Types of Waste:
Family waste, glass, steel, light weight aluminum containers and also window extrudes, steel canisters (smashed), hardwood, tires, white goods, plastic containers, pressure packs, medical waste as well as quarantine waste.
2. Needed Blazing Capacity:
Around 4,500 loads annually. The incinerator has to efficient in blazing sort of waste mentioned or any mixes thereof at a price of 3 heaps per hour. The system will be created to compete at least five consecutive days non-stop if needed.
3. Incinerator Layout Needs:
The system ought to be simple in design and procedure, with marginal digital components.
The incinerator and connected air pollution control modern technology will certainly be:
a.Low being used of supporting fuel;
b.Low in electric power usage;
c.Require very little pre-processing of Local strong waste;
d.The air contamination system shall adhere to EU Waste Incineration Regulation 2000/76 and also creates component of the entire incinerator arrangement.
3.1 Particular Data that must be Given with the Style
3.1.1 Incinerator Information:
a.Batch Lots Capability;
b.Primary chamber style (density, diameter, length, insulation, cellular lining, quantity hearth location, weight); c. Second chamber design (thickness, diameter, length, insulation, lining, volume hearth location, weight);.
c.Exhaust stack style (density, diameter, lining number of sections, overall stack size, height above base, weight);.
d.Type and variety of supporting gas heaters;.
e.Fuel demands– type, quantities;.
f.Electrical power usage;.
g.Electrical services called for;.
h.Water requirements– amounts;.
i.Any various other input demands and also consumables;.
j.Temperatures to be achieved to ensure appropriate destruction of waste and adhere to called for air pollution control requirements (EU Waste Incineration Regulation 2000/76);.
k.Residence time to guarantee ideal devastation of waste as well as comply with needed air pollution control criteria;.
l.Potential weight reduction (percent) of waste;.
m.Options to instantly and also continually display and document information such as days, time of day, batch sequential number;.
n.A temperature or aesthetic sign to show warmth status of equipment; and also.
o.Details on visuals screens as well as/ or computer system recording gadgets.

3.1.2 Air Pollution Control System Information.
a.The sort of air pollution control devices selected will follow EU WID Waste Incineration.
b.Directive 2000/76;.
c.Details on the gas cleansing systems to improve the elimination of great bits, acid gases and also hefty.
d.metals;.
e.Details on elements, such as:.
quencher;.
condenser/ absorber;.
venturi scrubber;.
entrainment separator and.
emissions pile( s).
Electrical power usage;.
f.Any various other input demands as well as consumables (e.g. lime);.
g.Details on graphic displays as well as/ or computer recording devices;.
h.Environmental needs – – The system would certainly have the ability/ ability to abide by pertinent air quality standards; i.e.EU Waste Incineration Regulation 2000/76. (or similar standards as well as requirements acceptable to the Australian Commonwealth Federal Government Department of the Setting);.
i.Specify air contamination parameters that are kept an eye on.
3.1.3 Site Demands for the Incinerator.
a.Total land area dimentions;.
b.Infrastructure needed (supply of water, power supply water drainage); and.
c.Any particular ecological or climatic/meteorological aspects that requires consideration.
3.1.4 Housing Needs and also Style.
a.Details on needs for a protected unit for the burner and connected air contamination control system. The room will certainly be designed to attain job-related health and safety needs such as: a. Free space is readily available on all sides as well as warm radiation is kept at a minimum giving the operators an:.
b.easy workable environment and also ventilation;.
c.There are safe storage space centers for waste;.
d.There are measures to stay clear of vermin as well as pests;.
e.The materials will be of adequate architectural thickness for security and to hold up against sea corrosion.
4. Training, Upkeep And Direction Manuals.
4.1 Upkeep Handbooks.
Supply information on maintenance demands, such as:.
a.General cleaning as well as upkeep– regularity, skills/ technological experience required;.
b.Expected life span of components as well as the system as a whole;.
c.Expected regularity of the requirement for substitute of components;.
d.Availability of parts as well as location of vendors;.
e.Frequency of requirement for significant overhauls; and also.
f.Estimated down time needed for general upkeep as well as significant overhauls.an incinerator for our dead pets in the ranch particularly poultry.

For incineration, basic and also pathological incinerators

Main unit
Application    For incineration, general and pathological
Capacity      50 – 60 kg/h burn rate
Type    Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit
Operating time                   Minimum 8 hours daily
Operating temperature        From 850 0C to 1200 0C, Automatic controlled
Residual Ash                       5 to 10%
3.2     Primary Chamber
Construction    Constructed from heavy duty mild or aluminized  steel Or
equal and approved equivalent
Insulation material               Refractory material lining similar or equal to calcium
Silicate and hot face combination of heavy duty brickwork
Internal Construction           Fixed hearth type complete with gratings, concave bottom
and charging door, lined with refractory material
Charging Door                      Suitable for manual loading of wastes and with smooth
Dear seal equivalent of Ceramic seals with hinges.
Door Lock                             Automatic, Electric type
Ash removal door       Provided, for removing resultant bottom ash leftovers                              from the Primary chamber
Gratings      Provided
Loading    Manual loading of waste
Primary Burner                           Fully automatic, with fuel, temperature and speed controls with ignition system, flame detector, Air fan complete with safety features, flame failure,  Diesel fired fuel injector type and Flange mounted
Blower    Provided. For supplying excess combustion air through the distribution system with speed control system
Temperature    Minimum exit 850 0C
Observation port    To be provided with protective glass type
3.3       Secondary chamber
Construction      Constructed from heavy duty mild or aluminized steel or equal and approved equivalent
Insulation    Refractory material lining
Combustion Temperatures           Above 850 0C, controlled electronically
Gas residue or retention Time          > 2 second at minimum 850 0C
Secondary Burner                       Provided, Diesel fired, fully automatic, with fuel, temperature and speed controls, With ignition system,                                                                  Flame detector, Air fan, Complete with safety features, flame failure Diesel fired fuel injector type.                                                                  Flange mounted
Ejector    Provided, Venturi type, for cooling the flue gases
Combustion Air Fan    Provided for supplying combustion and creating a negative drift and turbulences
Temperature    Maximum  1600 0C
3.4       Chimney
Construction      Constructed from heavy duty mild or aluminized steel  or equal and approved equivalent                                                                 Refractory material lining
Length    10 m above ground
Bore    about 350mm diameter
Discharge temperatures             About 850 0C
Emissions      To comply with standards in section 9 of third schedule of the waste management regulations, 2006.
3.5       Electrical System
Control unit                                    Fully automatic with microprocessor based control                                                                      unit (PLC) automating all operations of the                                                                      incinerator. Capable of monitoring all incinerator parameters With large LCD or similar for display of all progress
Parameters  i.e. temperature of primary and secondary chambers, turbulence and time
With status lamp
With user of defined and differed programmed operating cycles for different type of loads/conditions
With safety interlocks, display of errors and visible and audio alarms.
System for continuous  emission monitoring
Isolator switch                                  Supply and install isolator switch 240V, 100A for the                                                                    incinerator unit, including all necessary cables 10m
Distribution Board    Supply and install distribution board. 100 A, complete with MCBs suitable for the rating of the incinerator unit and associated equipment.  Wiring   to be done according IEE regulations.
Wiring    Make provisions for wiring the isolator switch, Distribution Board control unit to Incinerator and all associated equipment inside to incinerator room.                                                                       Working length 20m.  Wiring to be done using PVC Sheath cable on steel conduits and trucking and in accordance with IEE regulations
Fuel System                                       Supply and install storage fuel tank inside the incinerator room at an elevated position (about 1.5 m above the floor)
Fuel Tank                                            Tank capacity, 400 liters, constructed from preferable suitable metallic material or high temperature resistance material
Fuel type    Diesel
Fuel Lines                                           Supply and install fuel lines, complete with fuel filters, pump, sight glass, fuel level and all other safety devices and connect from fuel tank to incinerator.
Working length , 20m
Fuel pipe material; Special copper pipes or similar                                                                        and approved materials
4             Physical characteristics
Main unit                                           Floor mounted, stand alone, fixed hearth type
Dimensions      About 1.2 x 2.2m (WxD)
5  Operating environment
Power Requirements                       240V,A/C 50Hz, single phase, with PE
Ambient temperature                     10 0C to 40 0C
Relatively humidity                          40% to 90%
6. Accessories
Rack, 2 m long                               1 piece
Waste cart, stainless steel               1 piece
Spare parts
Burner    1 set
Fuel Filters                                         6 sets
All other spare parts                   required for replacement during and after 12 months of operations.    2 pieces of each
8              Quality Standards
Manufacturing standards               NEMA Kenya Act, 1999
Legal Notice No.121 of 29th September 1999 on waste Management Regulations
EU waste incinerator Directive- EC 76/2000
BS 3316
WHO Emission Standards
World Bank Emission Standards
or any other internationally recognized standards
Conformity to standards                      CE marked or any other internationally recognized documents
9          Local back up service
Available    Should be available locally
Capacity to service equipment                                                                         Manufacturer/Agent shall have adequate facilities, spare parts, qualified and skilled technical staff to offer comprehensive maintenance  service and spare parts sales for the lifespan of the incinerator
10       Delivery point
KEMSA    For inspection and verification
Moi Voi, Makindu
Maragua, Eldama Ravine and Isiolo Hospitals      For installation, testing, NEMA Certification and commissioning
Pre installation works
Provide for foundation plinth, necessary plumbing works, Fuel piping works, Elevated Diesel oil storage tank, electrical works including cabling, trunking and switch gears required to install the incinerator and all its accessories to required IEE standards
Installation and testing    Complete installation and set up of the incinerator at designated as per manufacturer’s instructions
Provide fuel and test run the incinerator for 3 hours daily for 7 days
Training
User training                                           On site user training on operation and daily up keep
Maintenance training                            On-site maintenance training on Preventive Maintenance, repair and trouble shooting
Technical Documentations
User manuals                                          2 sets
Service manuals                                     2 sets
Drawings    2 sets
15        Commissioning
Testing and Commissioning of the machine to the satisfaction of the user
Warranty
Equipment      Minimum of one year after commissioning on all parts.
Equipment system                                     Nil
17.    Maintenance contract
Comprehensive preventive & repair         service      Provided a 12 months comprehensive preventive and repair service contract inclusive of spare parts and material from date of commissioning

2 combustion chambers type burner

Load Capacity minimum:  1500 kg
Burner fuel type:  Diesel
Burner fuel rate max.:   20-25 Liter diesel/ per hour
Burners minimum: 3
Burning rate minimum: 200-300kg/per hour
Furnace bar area minimum: 2 м3
Fuel tank capacity minimum: 300L
Main chamber burning temperature min. 1100 0C
Afterburner chamber burning temperature min.  1300 0C
Power supply 220V
Incinerator items and electrical appliances should be weather proof
and humidity resistant within the range of 30-90 %
Incinerator should be compliant to the environmental protection rules
in accordance to national legislation
Maximum dimensions – Length – 5m, width – 3.5m, height – 5m.Medical and Biological wastage.
3.1              Main unit
3.1.1
Application      For incineration, general and pathological
3.1.2                                            Capacity       100 – 120 kg/h burn rate
3.1.3
Type    Two  combustion chambers type; primary  and Secondary, controlled/forced combustion air type with a flue gas emission scrubbing unit
3.1.4         Operating time                   Minimum 8 hours daily
3.1.5          Operating temperature        From 850 0C to 1200 0C, Automatic controlled
3.1.6          Residual Ash                       5 to 10%
3.2     Primary Chamber
3.2.1
Construction    Constructed from heavy duty mild or aluminized  steel
Or equal and approved equivalent
3.2.2
Insulation material               Refractory material lining similar or equal to calcium
Silicate and hot face combination of heavy duty brickwork
3.2.3
Internal Construction           Fixed hearth type complete with gratings, concave bottom and charging door, lined with refractory material
3.2.4
Charging Door                      Suitable for manual loading of wastes and with smooth
Dear seal equivalent of Ceramic seals with hinges.
3.2.5          Door Lock                             Automatic, Electric type
3.2.6
Ash removal door       Provided, for removing resultant bottom ash leftovers                              from the Primary chamber
3.2.7                                    Gratings       Provided
3.2.8                                            Loading    Manual loading of waste
3.2.9           Primary Burner                           Fully automatic, with fuel, temperature and speed  controls with ignition system  flame detector                                                         Air fan Complete with safety features, flame failure                                                                    Diesel fired fuel injector type
Flange mounted
3.2.10    Blower      Provided.  3 phase for supplying excess combustion air through the distribution system with speed control system
3.2.11    Temperature    Minimum exit 850 0C
3.2.12                               Observation port    To be provided with protective glass type
3.3    Secondary chamber
3.3.1
Construction    Constructed from heavy duty mild or aluminized steel or equal and approved equivalent
3.3.2                                            Insulation    Refractory material lining
3.3.3             Combustion Temperatures      Above 850 0C, controlled electronically
3.3.4             Gas residue or retention time                                              > 2 second at minimum 850 0C
3.3.5    Secondary Burner    Provided,
Diesel fired,
Fully automatic, with fuel, temperature and speed controls
With ignition system
Flame detector
Air fan
Complete with safety features, flame failure
Diesel fired fuel injector type
Flange mounted
3.3.6    Ejector    Provided, Venturi type, for cooling the flue gases
3.3.7
Combustion Air Fan                      Provided for supplying combustion and creating a
negative drift and turbulences with variable speed control
3.3.8                                         Temperature    Maximum  1600 0C
3.4       Chimney
3.4.1
Construction    Constructed from heavy duty mild or aluminized steel  or equal and approved equivalent
Refractory material lining
3.4.2                                                    Length    10 m above ground
3.4.3                                                        Bore    about 350mm diameter
3.4.4            Discharge temperatures             About 850 0C
3.4.5                                            Emissions    To comply with standards in section 9 of third schedule of the waste management regulations, 2006.
3.5       Electrical System
3.5.1    Control unit                                           Fully automatic with microprocessor based control
unit (PLC) automating all operations of the incinerator
Capable of monitoring all incinerator parameters
With large LCD or similar for display of all progress
Parameters  i.e. temperature of primary and second chambers , turbulence and time
With status lamp
With user of defined and differed programmed operating cycles for different type of loads/conditions
With safety interlocks, display of errors and visible and audio alarms.
System for continuous  emission monitoring
3.5.2    Isolator switch                                  Supply and install isolator switch 100A, 3 phase, 415V, 50Hz, for the incinerator unit , including all necessary cables 10m
3.5.3
Distribution Board           Supply and install distribution board 100 A, 3 phase 415V, 50Hz, complete with MCBs suitable for the rating of the incinerator unit and associated equipment.  Wiring   to be done according IEE regulations.
3.5.4
Wiring       Make provisions for wiring the isolator switch,
Distribution Board control unit to Incinerator and all associated equipment inside to incinerator room.
Working length 20m.
Wiring to be done using PVC Sheath cable on steel conduits and trucking and in accordance with IEE regulations
3.6    Fuel System
3.6.1          Fuel Tank                                            Supply and install storage fuel tank inside the incinerator room at an elevated position (about 1.5 m above the floor)
Tank capacity, 500 liters, constructed from preferable
suitable metallic material or high temperature
resistance material
Fuel type    Diesel
3.6.2
Fuel Lines                                       Supply and install fuel lines, complete with fuel filters, pump, sight glass, fuel level and all other safety devices and connect from fuel tank to incinerator.  Working length , 20m
Fuel pipe material    Special copper pipes or similar and approved materials
4. Physical characteristics
4.1              Main unit                                           Floor mounted, stand alone, fixed hearth type
Dimensions    About 2.5 x 2.8m (WxD)
5.  Operating environment
5.1              Power Requirements                      415V, A/C 50Hz, Three phase, with PE
Ambient temperature                     10 0C to 40 0C
Relatively humidity                          40% to 90%
6             Accessories
6.1             Rack, 2 m long                               1 piece
Waste cart, stainless steel               1 piece
7. Spare parts
7.1                                                      Burner        1 set
7.2              Fuel Filters                                         6 sets
7.3
All other spare parts                 required for replacement during and after 12 months of operations.    2 pieces of each
8              Quality Standards
8.2
Manufacturing standards               Environmental Management and Coordination Act, 1999
Legal Notice No.121 of 29th September 1999 on                                                                         waste Management Regulations
EU waste incinerator Directive- EC 76/2000
BS 3316
WHO Emission Standards
World Bank Emission Standards or any other internationally recognized standards
Conformity to standards                      CE marked or any other internationally recognized documents
9          Local back up service
9.1                                                         Available    Should be available locally
9.2           Capacity to service equipment                                                                         Manufacturer/Agent shall have adequate facilities, spare parts, qualified and skilled technical staff to offer comprehensive maintenance  service and spare parts sales for the lifespan of the incinerator
10       Delivery point
10.1                                                        KEMSA    For inspection and verification
10.2
Moi Voi, Makindu
Maragua, Eldama Ravine and Isiolo Hospitals      For installation, testing, NEMA Certification and commissioning
11    Pre installation works
Provide for foundation plinth, necessary plumbing works, Fuel piping works, Elevated Diesel oil storage tank, electrical works including cabling, trunking and switch gears required to install the incinerator and all its accessories to required IEE standards
12    Installation and testing    Complete installation and setup of the incinerator at designated as per manufacturer’s instructions
Provide fuel and test run the incinerator for 3 hours daily for 7 days
13            Training
13.1
User training                                           On site user training on operation and daily up keep
13.2
Maintenance training                            On-site maintenance training on Preventive Maintenance, repair and trouble shooting
14    Technical Documentations
14.1         User manuals                                          2 sets
14.2         Service manuals                                     2 sets
14.3                                                     Drawings    2 sets
15        Commissioning
15.1    Testing and Commissioning of the machine to the satisfaction of the user
16    Warranty
16.1                                                  Equipment      Minimum of one year after commissioning on all parts.
16.2       Equipment system                                     Nil
17.    Maintenance contract
17.2         Comprehensive preventive & repair         service      Provided a 12 months comprehensive preventive and repair service contract inclusive of spare parts and material from date of commissioning

Capacity per day around 8-10 kg wastage/day.·         Which product do you offer, only incinerator or also compactor, shredder machine, any other equipment related to waste treatment ?

·         For the incinerator, can you propose (and of so please send us specs and price) incinerator for 25 kg/hr, 50 Kg / hr, 100 kg / hr, 200 kg / hr ? what is your minimum and maximum size available ?

·         As we are not so experience in incineration process, can you tell us which type of waste can go into the incinerator and still respecting international environmental regulation ?

·         Do you equipped your incinerator with filters ? if so which one and they are following which standard ?

·         Can you supply exhaust pipe from incinerator to the roof, and then whirly bird to avoid the rain water to go into the pipe ?

·         When we install an incinerator within a building, what are the distance to observe between equipment and wall and roof (as we need to supply also the building to house the incinerator )

Gasified incineration for melting medical wastes incinerator

Gasified incineration for burning clinical wastes.

Gas kind: Natural Gas
Burning Capacity:
–– 30-50 kg/time
–– Daily 3-6 times

Burner size: max 2000x1200x3200 mm
Burning room volume:
–– Gasification space max 0.7 m3,
–– Additional burning area max 0.5 m3 ,

Dimension of the filling up entry: max 650×× 850 mm Air blower: max 0,5 kW Combustion-support burning devices: – Power max 0,2 kW INCINERATOR (WASTE BURNER).
Created to burn disposables that can as well as ought to be ruined on-site. Theses wastes consist of transmittable and also infected “red bag.” Surgical dressings, plastic examination tools as well as various other wastes.
Rapid, total, efficient garbage disposal.
Twin chamber combustion, Chambers insulated and also lined with high temperature refractory. Programmable digital temperature controls, temperature signs and also cost recorder. Modulating control for gas as well as air decreases gas consumption.
Minimum installment and also launch time.
Aluminized steel jacket lined with refractory and firebrick. Screens recorders and also other accessory equipment must be available.
Billing system:.
– Vertical cost door on key chamber.
– Pneumatic or hydraulic ram charging system.
– Auto closed down of the door after billing.
– Main as well as secondary chamber temperature presented and recorded (optional).
Charging price:.
– As much as 100kgs per hour of waste or red bag waste ranked at 2200 BTU’s per kg.
Fuel:- Natural Gas.
Capacity (Cubic Mtr): 1.65 M3 or even more.
Ave Ability: 100kg per hr.
Additional Chamber Capacity (CubicMtr):3.88 or more.
Size (mm): 1880 or far better.
Width (mm): 1280 or better.
Height Incl. Flue (mm): 7700 or far better.
Ash Door Opening (mm): 475×× 900 or much better.
Min. Running temperature level: 90 degree centigrade.
Max, Operating Temperature: 1350 level centigrade.
Residency time in Second Chamber: 2 sec.
Temperature Monitoring: Both for main and secondary chambers.
Filling SystemManual/semi-automatic.
Waste destruction efficiency:> > 90% by weight.
Filter: Ceramic or various other equal filters in order to lower the induction of unsafe air contaminants, particulates, carbon monoxide, dioxin/furane into the environment.
De ashing system: Manual/semi-automatic.
The System needs to be priced estimate total with:-.
– Pipes.
– Electric panels.
– Civil functions.
– Waste collection Trolleys.
Re-burning machine: Power max 0,2 kW Voltage: 220V/ 380V.
Weight: max 5000 kg

Containerized diesel fueled incinerators

Burner Kind: Containerized, gasoline
Burning Rate:100–– 120kg/hour.
Minimum Operating Temperature:850 o C( primary combustion).
Maximum Operating Temperature:1450 oC( Afterburner chamber).
Additional Burning Capacity: Compulsory.
Thickness Insulation:20 mm High.
Refractory Spreading: Minimum 65mm.
Sturdy refracting lining to withstand:1500 oC.
Typical stress out time: maximum:3 humans resources.
Fuel kind: Diesel.
Fuel Consumption in L/hr:7.5 to 9.
Home time in secondary chamber:2 sec.
Residue ash pot 100kg: Max 3.8 kg.
Burner kind: Animal waste incinerator.
Load Capacity minimum: 1500 kg.
Heater fuel kind: Diesel.
Burner fuel price max.: 20-25 Litre diesel/ per hr.
Heaters minimum: 3.
Burning rate minimum: 200-300kg/ per hr.
Furnace bar location minimum: 2 м3.
Gas tank capability minimum: 300L.
Key chamber burning temperature level min. 1100 0C.
Afterburner chamber burning temperature min. 1300 0C.
Power supply 220V.
Incinerator items and also electric devices ought to be weather proof and also moisture immune within the series of 30-90 %.
Incinerator needs to be compliant to the environmental management regulations in accordance to national legislation.
Maximum dimensions– Size– 5m, width– 3.5 m, elevation– 5m

Medical Waste Incinerator Trailer Mounted

*Double combustion chambers
*Smoke filter chamber and S.Steel chimney
*Italy Riello Oil burner and PLC Auto. control
*Heavy duty mobile trailer with safe parts 
*Minimal installation
*Mobile by truck tractor 
1. Should be Trailer mounted Trailer Type
2. Be able to burn Medical waste 100-200kgs per hour
3. Diesel diesel oil type
4. 220 V single phase
5. Incinerating temperature range 800-1200 degree Celsius  

Items/Model

TS100(PLC) (Mobile Type)

Picture

 

Principle

Medical Waste Incineration Treatment

Burn Rate

Average 100-200 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1200L

Internal Dimensions

120x100x100cm

Secondary Chamber

600L

Smoke Filter Chamber

Yes(Dry Scrubber)

Feed Mode

Manual

Voltage

220V

Power

0.9Kw

Oil Consumption (kg/hour)

average 20.4

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

200L

Feed Door

80x60cm

Chimney

3Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800

Diesel/LPG/LNG burning key burning chamber/primary combustion incinerator

Main burning
Diesel/LPG/LNG burning key combustion chamber/primary combustion zone
Second burning
Home time in the second chamber not less than 2 secs
Both key as well as the secondary temperatures preserved up until all the waste has actually been completely ignited
Chimney
Chimney with a minimal height of 4 meters above ground level
Minimum leave velocity of the discharges not much less than 10 metres/second
Temperature level Cautions
Distinct and/or visible alarm to warn the driver when the second temperature drops to below the required temperature
General
Control box that can be separated as well as installed on different stand a minimum of 1.5 meters from burner at around 1.6 meter

heightItem 1
Burner design A

Melt Rate 65kg/h minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time – – 2 Secs

– Fuel – Diesel/LPG/LNG, please show

Power Supply for Control Box – 220V-240V 50Hz single phase

Minimum running temperature level 850 ° C, please suggest

One year Spare Components Plan for complete maintainability

10m Tube Pipe, suggest size

I000 Litre Gas Tank + Pipeline System, show volume

Additional smokeshaft expansion, indicate elevation

Service warranty, suggest no of years

Item 2
Incinerator design B

Melt Rate 150kg/h minimum

Weight (kg), please suggest:

Additional Chamber

Gas Retention Time – – 2 Seconds

Diesel/LPG/LNG, please show

Power Supply for Control Box- 220V-240V 50Hz solitary stage
Minimum operating temperature level 920 ° C, please indicate
One year Spare Parts Bundle for total maintainability
10m Hose Pipe, indicate size
I000 Litre Gas Storage Tank + Pipeline System, suggest volume
Added smokeshaft expansion, suggest elevation
Warranty, show no of years

Product 3
Incinerator version C.
Burn Rate 250kg/h minimum

Weight (kg) please show:.
Second Chamber.
Gas Retention Time 2 Secs.
Fuel Diesel/LPG/LNG, please show.
Power Supply for Control Box 220V-240V 50Hz single stage.
Minimum running temperature 920 ° C, please suggest.
One year Spare Components Bundle for full maintainability.
10m Hose pipe Pipe, indicate size.
I000 Litre Gas Tank + Pipeline System, indicate quantity.
Extra chimney expansion, indicate height.
Warranty, indicate no of years

Heat Waste Incinerator

Capacity at least (4000) kg/day (( Day= 16 Working Hrs))

Ability at least (4000) kg/day (( Day= 24 Working Hrs))

With the following attributes:

* Automatic feeder as original part of the unit.

* Automatic ash/ leftovers elimination as initial component of the unit.

* Water Injection System to control the temperature> >

* Flue gas filtering system abiding by EU.

* Continual discharge tracking and recording system.

* It should include setup, testing, and also personnel training.

* 6 nos. of sturdy filling containers.

Item 4.
HTW Incinerator design D.
Burn Price – – 150kg/hour minimum.
Weight (kg), please indicate:.
Secondary Chamber.
Gas Retention Time 2 Seconds.
Gas Diesel/LPG/LNG, please show.
Power Supply for Control Box 220V-240V, solitary phase 50-60Hz.
Minimum running temperature 1200 ° C, please show

One year Spare Parts Plan for complete maintainability

10m Tube Pipe, show size.
1000 Litre Fuel Tank + Pipeline System, indicate quantity.
Extra chimney extension, suggest height.
Mobile Burner

Item 5.
Mobile Burner version E

Melt Price 50kg/h minimum

Weight (kg), please show:

Secondary Chamber

Gas Retention Time – – 2 Seconds

– Gas – Diesel/LPG/LNG, please suggest

Power Supply for Control Box – 220V-240V 50Hz solitary stage

Minimum running temperature level 850 ° C, please suggest

One year Spare Components Bundle for full maintainability.
Mobile Incinerator

Thing 6.
Mobile Incinerator version F

Melt Rate 100kg/h minimum

Weight (kg), please indicate:

Second Chamber

Gas Retention Time – – 2 Seconds

– Fuel – Diesel/LPG/LNG, please suggest

Power Supply for Control Box – 220V-240V 50Hz solitary stage

Minimum operating temperature level 850 ° C, please indicate

One year Spare Parts Bundle for full maintainability

10m Pipe Pipe, suggest size

1000 Litre Gas Container + Pipeline System, show quantity

Additional smokeshaft extension, indicate height

Warranty, indicate no of years.
Heat Waste Mobile Incinerator.
Product 7.
HTW Mobile Burner version G.
Burn Price 100kg/h minimum.
Weight (kg), please suggest:.
Second Chamber.
Gas Retention Time – – 2 Seconds. Fuel – Diesel/LPG/LNG, please indicate

Power Supply for Control Box – – 220V-240V 50Hz solitary stage

Minimum operating temperature 1200 ° C, please suggest.
Main burning.
Diesel/LPG/LNG burning main burning chamber/primary combustion zone.
Second burning.
House time in the second chamber not less than 2 seconds.
Both main and the secondary temperatures preserved up until all the waste has been entirely ignited.
Smokeshaft.
Chimney with a minimal elevation of 4 meters above ground level.
Minimum exit velocity of the emissions not less than 10 metres/second.
Temperature Warnings.
Audible and/or noticeable alarm system to advise the driver when the additional temperature goes down to below the called for temperature level.
General.
Control box that can be separated as well as mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter

elevation.
Guarantee, show no of years