Tag: waste

Incinerator YD-500 for Vietnam”

We finish this project in year 2010 to 2011 and delivery to Hochiminh port, Vietnam with 1×40’feet open top full container.

Big size combustion chamber up to 4.0m3 and Internal Dimensions is 257 x 147 x 108cm with feeding door opening 108 x 128cm. This model can be a small waste incineration factory with little amount of budget funds. If end customer use this for farm to burn animals like cow, horse or camel, no problem!

 

Model YD-500
Burning Rate 500 kgs/hour
Feed Capacity 800 kgs
Primary Combustion Chamber 4000 Liters
Secondary Combustion Chamber 1500 Liters
Mix Combustion Chamber Yes
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V/380V
Power 2.24Kw
Fuel Type Diesel Oil/ Natural Gas/LPG
Burner Italy Original
Oil Consumption (Diesel Oil) 31–59.1 kg/hour
Gas Consumption (Natural Gas) 19.2–64.2 m3/hour
Internal Dimensions 257 x 147 x 108cm (primary chamber)
External Dimensions 320 x 220 x 460cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 500 Liters
Door Opening 108 x 128cm
Chimney Length 14.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 13000 kgs
Operation Technical Specifications
Paimary Chamber Temperature 800℃–1000℃
Secondary Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Burning Efficiency >98%
Waste Lower Calorific Power 3000Kcal

Small Waste Incinerator 30kgs per hour Delivery”

Six Sets Medical Waste Incinerator with 30kgs per hour capacity for Afghanistan.

 

Items/Model TS30(PLC)
Burn Rate 30 kg/hour
Feed Capacity 60kg
Control Mode PLC
Combustion Chamber 330L
Internal Dimensions 75x75x60cm
Secondary Chamber 180L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) 10.2–20
Gas Consumption (m3/hour) 9.8–20
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 55x50cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 3000kg
External Dimensions 175x120x140cm

New waste incinerator for Macau”

New waste incinerator for Macau.

 

Items/Model TS50(PLC)
Burn Rate 50 kg/hour
Feed Capacity 100kg
Control Mode PLC
Combustion Chamber 560L
Internal Dimensions 100x80x70cm
Secondary Chamber 280L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 12.1–24
Gas Consumption (m3/hour) 9.9–26.1
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 70x55cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 4500kg
External Dimensions 230x130x155cm

Containerized Incinerator to NewZealand”

Containerized waste incinerator is our latest design for market. This incinerator is build in ISO container before leave factory. After customer received container, install the chimney and connect with electric power and setup oil tank, that’s all. Now, the burning capacity can be 30 kgs/50kgs/100kgs per hour for ISO 20′feet container. This moveable/mobile incinerator can be move by truck to any site by local customer.

This kind of incinerator is good choice for different end-customer site, Service personnel can move to there and service at local site. It is also best service type for family pet cremation service and other emergency status.

Hot sale small waste incinerators 30kgs and 50kgs per hour”

ts30

Items/Model TS30(PLC) TS50(PLC)
Burn Rate 30 kg/hour 50 kg/hour
Feed Capacity 60kg 100kg
Control Mode PLC PLC
Combustion Chamber 330L 560L
Internal Dimensions 75x75x60cm 100x80x70cm
Secondary Chamber 180L 280L
Smoke Filter Chamber Yes Yes
Feed Mode Manual Manual
Voltage 220V 220V
Power 0.5Kw 0.7Kw
Oil Consumption (kg/hour) 10.2–20 12.1–24
Gas Consumption (m3/hour) 9.8–20 9.9–26.1
Temperature Monitor Yes Yes
Temperature Protection Yes Yes
Oil Tank 100L 100L
Feed Door 55x50cm 70x55cm
Chimney 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec.
Gross Weight 3000kg 4500kg
External Dimensions 175x120x140cm 230x130x155cm

Oil fired incinerator,Medical Waste Incinerator”

Medical Waste Incinerator

 

Items/Model TS100(PLC)
Burn Rate Average 100 kg/hour
Feed Capacity Average 200 kg/feed
Control Mode PLC
Combustion Chamber 1200L
Internal Dimensions 120x100x100cm
Secondary Chamber 600L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 14–28
Gas Consumption (m3/hour) 10–32.2
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 200L
Feed Door 80x60cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 6000kg
External Dimensions 260x150x180cm

incinerator, medical incinerator, small incinerator,waste incinerators”

Nanjing Clover Medical Technology Co., Ltd.  is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. to 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.

Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime. *according to order
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.
* PLC Control Plane.*according to order
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.

Application Scope:
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.
3. Community & Sea Port & Station: Municipal Solid Waste, etc.
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

clinical waste burner



Australian burning style exclusive 5 25kg/hour
double chamber( LPG) burner or equal approved. burner
casing to be light steel with 125mm refractory lining containing
essential and second chamber, protected draft area above
second chamber, bundle burners, electronic temperature level control
systems, ash rake as well as poke, 2nd door in main chamber,
hands-on filling chute, semi automated operated counter well balanced
packing door with packing tray complete with stainless-steel flue
recommended extra components.