Tag: Waste Incinerators

pet incinerator for sale

  • We are looking at a simple incinerator which should be fired using domestic LPG bottles. Other sources of

ignition can be considered as well but we need to keep it simple.

 

 

 

Section VI. Requirements 2-86

 

 

required for preventive maintenance for five years and where necessary include stock of recommended spare-parts for

corrective maintenance.

  1. n) Training
  2. i) The supplier is required to provide adequate training on each equipment on the proper use and operation of the

equipment.·         Compact laboratory style

 

  • Two combustion chambers

 

  • Ecologically friendly

 

  • Up to 50kg of waste / hour

 

  • To be used for animals

 

  1. ii) Similarly, suppliers are required to provide adequate manufacturer’s training on the installation and

maintenance(both preventive and corrective)

  1. o) Packaging and Storage Conditions of Equipment
  2. i) The equipment and components should withstand temperature and humidity extremes likely to be encountered during

storage and transport.

  1. ii) The manufacturer should recommend procedures for storage of the equipment.

medical waste diesel incinerator

medical waste diesel incinerator Burning Rate:47.5–50kg/hour
Minimum Operating Temperature:850o C(primary combustion)
Maximum Operating Temperature:1450 oC(Afterburner chamber)
Secondary Burning Capacity:Compulsory
Density Insulation:20mm High
Refractory Casting:Minimum 65mm
Heavy duty refracting lining to withstand:1500 oC
Average burn out time :maximum:3 hrs
Fuel type:Diesel
Fuel Consumption in L/hr:7.5 to 9
Residence time in secondary chamber:2sec
Residue ash post 100kg:Max 3.8kg
Device for preventing infectious spatter and/or cross-contamination by safely sterilizing needles, rings, etc. by infrared heat.
Electrical characteristics
1) A 120V, 60Hz mono-phase electrical source with line connection plug NEMA 5-15 type.
2) Protections against over-voltage and over-current line conditions.
3) Compliance with applicable Haitian standards and regulations.

Operational characteristics
4) Fast complete sterilization in around 5-7 s.
5) Fully isolated quartz/ceramic tube, to grant safety for the user (no open flame).
6) Working temperature around 820°C.
7) Mounted on a stable base, as per example below.

incinerator

  1. l) Ease of Use and maintenance
  2. i) The unit should be simple to learn to use, operate, and maintain.
  3. ii) The unit should have abbreviated operating instructions included on or with the unit (e.g., on a laminated card

attached to the unit).

iii) The unit should be easy to clean, disinfect, and/or sterilize, as appropriate. iv) The unit should be designed for

easy access to serviceable parts.

 

  1. m) Special maintenance tools, spare-parts and consummables
  2. i) Where necessary or required, the supplier must include any special tools required for the maintenance of the

proposed equipment

  1. ii) Each equipment must be supplied with the recommended spare-parts
  • The new incinerator is to be used for burning mostly paper but also cigarettes confiscated by customs.

 

  • The design is to be based on 1200 bags per year, standard brown bags for burning “ BANNER”, Product Code

971-0003, capacity 75 litres;

 

  • The quantity of cigarettes is not known but is not expected to be the deciding factor, at least in terms of

capacity.

Air Emissions Environmental Specifications CA


Air exhaust needs develop restrictions on the quantity of contaminants that can be launched into the ambience.

Table 1. Air Emission Demands for Solid Waste Incinerators

Requirements Numeric Criterion Description

Dioxins and Furans
80 pg I-TEQ/cubic metre
Gadget of procedure is picograms of International Toxicity
Matchings per cubic metre of air

Mercury
20 µg/ Rcubic metre
System of treatment is micrograms per Referral cubic metre (the quantity of gas adapted to 25oC and additionally 101.3 kilopascals)

Opacity is the level to which the exhaust gases decrease the transmission of light and cover the sight of any type of kind of item in the background. It is expressed as a portion standing for the degree to which a things watched with the gases is covered. Not a discharge requirement, opacity offers an indication of the general effectiveness of the burner during regular operation2. Opacity in the burner stack requirement to not exceed 5%. While it is not planned for that opacity levels would certainly surpass 1% to 2% under normal procedure, values more than 5% recommend the burner is not carrying out properly as well as included performance exam in addition to alteration is required.

Figure 6 – – – – Instances of Smoke Opacity Scores
The opacity rankings are price quotes in addition to are attended to illustratory goals only
Centre and likewise best photos thanks to GNWT Division of Environment as well as Natural Resources


pet incinerator price

  1. j) Controls
  2. i) The controls (i.e., switches, knobs, etc.) should be visible and clearly identified, and their functions should

be self-evident.

  1. ii) Device design should prevent misinterpretation of displays and control settings.

iii) Switches and controls should be protected against accidental setting changes (e.g., due to someone brushing

against the panel).

  1. iv) Controls should be sealed against penetration of liquids.

Capacity: 30 kg per hours for a maximum load of 120 kg.

GLP Gas

Voltage: 110V-120V

Semiautomatic control board

Stainless steel chimney, 3.5 meters above the incinerator.

High temperature painting for all the incinerator.

Front door for loading and unloading.

Hours of  Operation the burn 4000kg/day ( if to fed as batches , please mention )

 

  1. k) Labeling
  2. i) Labels and markings should be clear and legible.
  3. ii) Labels and markings should be durable enough to withstand routine cleaning and normal wear.

iii) Appropriate warning legends should be provided on the unit.

Relating To Hiclover Medical Enviromental


HICLOVER, Nanjing Clover Medical Development Co., Ltd, supply system options for medical ecological management, animal as well as also household pet dog cremation design, various other municipal solid waste incineration job.
We offer single combustion chamber, double burning chambers, 3 burning chambers as well as likewise multi-combustion chambers waste incinerators for research laboratory, center, university hospital, medical center, hygiene clinical waste destruction with medical non reusable, biological waste, professional plastic waste, contaminated materials, red bag waste, needle disposal, gauze as well as bandages, secured sharp containers, pathological waste, trace-chemotherapeutic wastes, and so on
.
Our collection of incinerators provide for little to large range pet dog cremation related solutions, such as poultry ranches, cattle ranches, lamb ranches, pig ranches, stables, kennels, evaluating research laboratory, catteries, family pet canine crematoriums.

The burner shed waste in primary burning chamber and additionally shed the smoke from crucial combustion chamber once more to ensure eco-friendly without black smoke, smelless, lower pathogenic bacteria infection.
System remedies for medical waste eco-friendly, consisting of waste incineration, smoke discharge therapy, high-temperature cleanliness, ultraviolet hygiene lamp, waste shredder, needle destroyer, clinical waste strategy, sharp containers, etc.

The household pet dog cremation devices humanized style with movable system, little area covers for modern pet dog cremation regional business owner throughout the world.
The containerized mobile incinerator mounted in ISO container prior to leave making center, pre-installation, no incineration house develop building and also construction, movable by vehicle and likewise ultraviolet light hygiene inside.
HICLOVER is growing brand name for environmental protection field, and additionally market show a lot of Africa, Center East, Southeast Asia nations in addition to part of The United States and Canada, Europe area. We a re relied on friend for governmental organizations, charitable organizations, global specialists, logistics organizations, military, pet cremation entrepreneur, etc. We have export experience greater than 40 countries, including battle zone like Iraq, Afghanistan, Somalia, South Sudan.

We are china incinerator manufacturer, professional as well as also merchant. Producer clear up rate for incinerator client, supply clinical heater, university hospital burner, animal burners, hog heaters, family pet dog cremation devices, little incinerator, household pet incinerator, animal heater, mobile burner, little animal heater, communicable waste pyrolysis equipment, research laboratory incinerator. HICLOVER help client minimize purchase spending plan, personalized made function, quality products and likewise positive option.


Required Specs for Mobile Burner


Functional Abilities

  • PROCESS MINIMUM 1 TON PER DAY
  • OPERATED WITH LIMITED TRAINING
  • REGULAR MAINTENANCE CAN BE COMPLETED WITH LIMITED TRAINING
  • COMPLIES WITH EURO / OR US-EPA EMISSION STANDARDS
  • ABILITY TO BURN WASTE LUBRICANTS (POL)
  • HANDLE ORGANIC SOLIDS (TO INCLUDE RMW)
  • DEPLOYABLE
  • MOBILE
  • 24 HRS OF CONTINUOUS USE
  • AUTOMATIC LOADING SYSTEM
  • AUTOMATED ASH REMOVAL SYSTEM
  • GAS SCRUBBING SYSTEM
  • 95% REDUCTION OF SOLID WASTE
  • OPERATE OFF DIESEL OR FUEL OIL
  • CAPABLE OF BURNING 4 UNITS OF WASTE PER UNIT OF FUEL
  • ABLE TO TAKE ALL COMBUSTIBLE WASTE TO INCLUDE: PAPER, PLASTIC, CARDBOARD, FOOD, USED OILS, SLUDGE, OILY RAGS, WOOD
  • NO PRE-TREATMENT OF WASTE REQUIRED
  • FIVE (5) YEAR COMPONENT WARRANTY

Technical Specs

  • OPERATION MANUAL AND TRAINING MANUAL FOR EACH INCINERATOR
  • SET UP AND INSTALLATION INSTRUCTION MANUALS
  • BLUE PRINT/ SCHEMATIC PROVIDED THAT OUTLINES THE PHYSICAL DIMENSIONS OF THE 20’ INCINERATORS
  • INCINERATORS COMPOSED WITH HEAVY DUTY WELDED CONSTRUCTION
  • OPERATED AND TRANSPORTED IN 20’ INCINERATORS (CONTAINERS)
  • FULL FRONT AND OPTIONAL REAR ACCESS
  • PRIMARY / SECONDARY TEMPERATURE CONTROLS


waste incinerator manufacturers from china

Incinerate: medical waste and general waste Capacity to burn waste:
400-500kg/hr
Fuel: Diesel
Fuel Consumption: 10 liters/hr maximum
Incineration temperature: 950-1300 degrees centigrade
Casing: thick (min 5mm) stainless steel casing and fully insulated to
withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz
high-capacity, powerful, European Standard incinerator,ideal for high volume incineration,with integral after-burner for greater efficiency and emissions control.
Waste Type and Burn Rate
Designed specifically for use by poultry farmers,
sheep farm owners,   abbatoirs and for pet
cremation. The incinerator will burn up to 50kg of
waste per hour (up to 150kg burn
Construction
Mild steel welded fabrication consisting of sheet steel
and structural section supports.
Lining
Monolithic high grade refractory concrete with high grade insulation backing.
Burners
Fully automatic, high-efficiency burners with electronic ignition, flame recognition and combustion control devices fitted.
Loading – Ash removal
Manual ash removal from the primary chamber. (Ash doors are available on request).
Exterior finish
Multi-coat high quality, high-temperature aluminium enamel top coat paint, finished in silver.
Control
Fully automatic sequential control provided by internal
waste incinerator manufacturers from china, PLC system providing control of:
1. Secondary chamber pre-heat
2. Burn cycle (variable)
3. Cool down cycle
Fuel Options
Diesel, LPG, Natural or Bio Gas.
Typical Fuel Consumption
Diesel: 8 / 10 litres per hour
Liquid Propane Gas: 6 / 8 litres per hour
Natural Gas: 7 / 9 Nm3 per hour
Electrical supply
240volt 16 amp.
Key Specifications
Chamber Volume 2.38m3:
2.2m (l) x 0.9m(w) x 1.2m(h)
Load Capacity up to 1000kg
Load Method Top.·         Type: Pyrolytic

·         Use: For drugs

·         With Chassis to be Mounted in truck/lorry

·         May have a primary and secondary combustion chamber

·         Must have a dilution chamber

·         Capacity: 100 Kgs per hour

·         Power Source: Diesel or Natural Gas or Liquified Natural Gas

clinical facility incinerator manufacturers


SCHEDULE 2

  • TECHNICAL SPECIFICATIONS OF THE INCINERATOR
  • General Description

Previous experience in the supply, installment as well as appointing of burners

  1. Overall plant layout
  2. Feed chamber/charging
  3. Primary combustion chamber
  4. Particulate scrubbers
  5. Acid gas
  6. The stack/chimney.
  7. Minimum capacity of primary chamber = 10cubic meters
  8. Burn rate (rate of waste incineration) = 10 kg per hour
  9. Should have a full width counterbalance loading door allowing easy access to the main chamber for loading and removing ash.
  10. The INCINERATOR should be NEMA approved in accordance with Environmental management and coordination (Waste management) Regulations of 2006.
  • Scope Of Work

at least10kg per day

  1. Supply, install and commission an incinerator as provided   in the technical specifications
  1. Provision for adherence to OSHA and other statutory requirement relating to Health and Safety of workers during execution of the works covered in this
  1. Assessment and preparation  and construction of  a standard incinerator shed with one waste  storage room  ( see the design )
  1. Provision of operation and maintenance manuals and drawings complete with maintenance schedule and
  1. Fuel oil storage tank- Mild steel 1000 liters capacity
  1. Onsite training for operation and maintenance

Basic Strategy design to Supply Overall plant layout.

Genuine estate center with one waste storage room

Deal Real estate designs with ideal cross air circulation

  1. TECHICAL SPECIFICATIONS OF THE INCINERATOR

Chamber (Afterburner Optimum departure temperature must not be much less than 1100oC

Security interlock, Fan Newbie, Heating System on/ off switch/door safety button, Vehicle layer button, temperature levels regulate device.

  • Primary Combustion
  • This chamber should be equipped with burners that use low sulphur
  • The chamber should ensure a minimum exit temperature of 850 degrees
  • This unit should operate at over 1100 deg C to ensure complete
  • This chamber should be equipped with burners that use low sulphur
  • Heavy-duty steel casing
  • High quality refractory lining and insulation
  • Large full size top load door and liquid retention
  • 1 x oil fired ignition burners operated on/off
  • Secondary Combustion Chamber (After burner)
  1. Heavy-duty steel casing
  2. High quality refractory lining and insulation
  3. 1 x oil burner
  4. Should be fitted with burners that use low sulphur
  5. Ensure secondary air supply is controlled.
  6. Ensure residence time is not less than two seconds.
  7. Ensure that the gas temperature as measured against the inside wall in the secondary chamber and not in the flame zone is not less than 1100 degrees
  8. Ensure the emitted oxygen content of the emitted gases is not less than 11%
  9. Ensure both primary and secondary combustion temperatures are maintained until all waste is completely
  • Particulate Removers

Key Combustion Chamber Minimum departure temperature level need to not be much less than 850oC

  1. Cyclone separator
  2. Electrostatic precipitators
  3. Fabric filters
  • Chimney/Stack
  1. The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all The topography and height of adjacent buildings within 50 meters radius should be taken into account.
  2. The chimney should be visible to the operator from the feeding
  1. The minimum exit velocity should be 10 meters per second and at least twice the surrounding wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of exiting
  2. The point for measurement of emissions shall be
  • Instrumentation
  1. Instrument for determining the inside wall temperature and not burner flame temperature must be provided for both primary and secondary
  2. An audible and visible alarm must be installed to warn the operator when the secondary chamber temperature drops to below the required
  3. A carbon monoxide and oxygen meter/recorder should be
  4. A smoke density meter/recorder should be
  5. A solid particulate meter/recorder should be
  6. Any other instrument that may be considered
  • Location / Siting of the Incinerator
  1. a) The incinerator must be sited in accordance with the relevant local municipal authority planning regulations and the topography of the site must be compatible with premises in the
  • Emission Limits
  1. Combustion efficiency (C.E) shall be at least00% where C.E = %Carbon dioxide x 100 / [% Carbon dioxide + carbon monoxide]
  2. The temperature of the primary chamber shall be 800 +/- 50 degrees centigrade
  3. The secondary chamber gas residence time shall be at least 1 second at 1050 +/- 50 degrees centigrade with 3% oxygen in the stack
  4. Opacity of the smoke must not exceed 20% viewed from 50 metres with naked
  5. All the emission to the air other than steam or water vapour must be odourless and free of mist, fume and
  6. A 99.99% destruction and removal efficiency (DRE) for each principal organic hazardous constituent (POHC) in the waste feed where DRE [ ( Win – Wout) /Win ] x

Second Burning Optimum leave temperature level need to be not a lot less than 1100oC

  1. The average dioxin and furan concentration in the emission should not exceed 80mg/m3 total dioxins and furans if measured for a period of 6 to 16
  • Ease of Use
  1. Auto
  2. No pilots to
  3. Automatic control and temperature monitoring
  4. Built-in skid facilitates placement
  • Fuel Efficiency
  1. Rapid incineration means low fuel
  1. Up to 20kgs per hour (dependant on application).
  2. Thick refractory lining rated to 1400 deg C in main chamber retains heat, increasing
  • Quality Built to Last
  1. Heat resistant 3mm
  2. Stainless steel
  • Key Features
  1. Low running and maintenance costs
  2. Fully Automatic and simple to operate control panel
  3. Afterburner Preheat
  4. Incineration Temperatures in Excess of 900 degrees C
  5. 3 mm Steel Casing and Fully insulated
  6. Dense Refractory Concrete Lining Rated to 1400 degrees C
  7. Solid Hearth to Allow Maximum Burnout
  8. Large Top Opening Lid For Easy Loading
  9. Stainless Steel Flue as standard
  10. 12 Months or 1000 hours
  11. Optional Stainless Steel Casing
  12. Heat Recovery System option
3.13 Fuel and Capacity  
1. Low sulphur fuel
2. Capacity (Cubic Mtr) .10
3. Average Capacity 40kg
4. Fuel Consumption (ltrs / hr) 3
  • External Dimensions
1. Length (mm)               735  
2. Width (mm)                500
3. Height Incl. Flue (mm) 1960
4. Door Opening (mm) 325 x 325
  • Internal Dimensions
1. Length (mm) 620
2. Width (mm) 390
3. Height 500
  • Operation
  1. Minimum Operating Temperature 950
  2. Maximum Operating Temperature 1320
3. Burn rate per hour 5-20kgs
4. Temperature Monitoring Available
  • Particulate Removers

SECTION VII

  1. Cyclone separator
  2. Electrostatic precipitators
  3. Fabric filters
  • Chimney /Stack
  • The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all The topography and height of adjacent buildings within 50 meters radius should be taken into account.
  • If possible the chimney should be visible to the operator from the feeding
  • The addition of dilution air after combustion in order to achieve the requirement of these guidelines is
  • The minimum exit velocity should be 10 m/s and at least twice the surrounding wind speed (Efflux velocity = wind speed x 2) whichever is higher to ensure no down washing of exiting
  • Point for the measurement of emissions shall be
  • Control Panel
  1. Control of 2 burners
  2. Timer control 0- 12 hours
  3. Integral fan timer control
  4. Temperature and thermostatic control

COST TIMETABLE FOR THING

NO: REQUIREMENTS SUPPLIER’S REMARKS
1. Experience

Price schedule for Supply, Installment, Checking out as well as Appointing of an incinerator for Turkwel Power Terminal

 
2. 1 Year Maintenance Contract  
3. Work rate

WONDERFUL BARGAIN

 
4. Design

1

49,50,51,60,61,77,78,79,80,81,100

ENTIRE WHOLE LOT

GREAT DEAL

Offer Housing styles with appropriate cross air flow

Chamber (Afterburner Maximum departure temperature should not be less than 1100oC

 
5. Standard control panel

Security interlock, Follower Beginner, Heater on/ off switch/door safety switch, Car fold button, temperature levels regulate device.

 
6. Combustion Chambers

Key Combustion Chamber Minimum departure temperature level must not be much less than 850oC

Second Combustion Optimum leave temperature level need to be not much less than 1100oC

 

SECTION VII

PRICE SCHEDULE FOR ITEM

Rate schedule for Supply, Installment, Examining as well as Commissioning of an incinerator for Turkwel Power Station

1 2 3 4 5 6
Item Description Unit of sale Quantity Unit price Total price
1. Supply, install, and commission the incinerator as specified. LOT 1    
2. Construct a standard incinerator housing facility as per the drawing and architectural notes provided  

GREAT DEAL

 

1

   
4. Construct one  waste  storage  room (provide specs on room size, construction material etc) LOT 1    
5. Supply / adhere to  the requirement of OSHA 2007 act

49,50,51,60,61,77,78,79,80,81,100

LOT 1    
6. Onsite training of Operation and Maintenance staff. LOT 1    
7. All the key Spares (Attach a separate List) LOT 1    
8. Supply and install 1000 liters Fuel oil storage tank and its secondary containment with Diesel oil level indicator and necessary piping with valves for visual checking of fuel level. LOT 1    
9. Supply of Operation and Maintenance Manuals.  

WHOLE LOT

1    
10. All other items not specified but necessary to complete the Installation.   A separate list of these items to be attached.  

LOT

1    
11. Fencing of  a compound  of 10 meter length  by 10 meter  width   using Concrete  poles  high Gauge mesh wire , and a lockable gate. (Indicate size and design of gate) LOT 1    
  Sub Total        
           
  Discount  (%) if any        
  Applicable Taxes and Duties        
           
  Total Cost in Kshs        


mobile incinerator china

Temperature:  ambient temperature ranges between 21 – 450  C or more in poorly ventilated rooms. The hottest month

of the year is March. Environmental temperature can be such that inferior rubber and plastic materials can easily melt

or deformed. Bidders must ensure all materials will be able to withstand such temperatures

 

4)  Humidity: humidity is usually high about 65 – 90%. Electronic units must be protected to prevent the effect of

condensation.

 

5)  Dust: this is a major problem especially during the dry season. Dust get into equipment and clogs up filters.

Additional protection must be provided where necessary and where applicable spare filters supplied to last not less

than five years continuous use.

 

6)  Vermin: these are also available and occasionally enter into equipment to chew cables and urinate on boards to

cause short circuit. This can be prevented by providing vermin guard where necessary to prevent entry of such

destructive animals.

7)  The proposed equipment must conform to the current relevant international standard such as ISO; CE; IEC, ANSI

and/or BS

 

8)  Language:

  1. a) All labels and markings on the equipment must be in English language. b) All software programmes in the proposed

equipment must be in English

language