Model TS30 oil terminated waste small incinerator 30kgs

Model TS30 oil fired waste small incinerator 30kgs/hr.

Items/Model

TS30( PLC)

Picture

Melt Rate

Typical 20-30 kg/hour

Feed Capability

Typical 60kg per feeding

Control Setting

PLC( Programmable Reasoning Controller Incinerator)

Burning Chamber

330L

Inner Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Setting

Handbook Feeding

Voltage

220V

Power

0.5 Kw

Oil Consumption (kg/hour)

Average 13.3

Gas Intake (N.G, m3n/Hour)

Typical 16

Gas Intake (L.P.G, m3n/Hour)

Ordinary 11.7

Temperature Level Screen

Four Digital Display

Temperature Defense

Yes

Oil Tank

100L or More( Optional)

Feed Door

55x50cm

Chimney

5Meter or More( Optional)

Chimney Kind

Stainless Steel

1st. Chamber Temperature

800 ℃–– -1000 ℃

2nd. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4000kg

Outside Dimensions

175x120x140cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-14

Containerized Mobile Incinerator Model CA50

Waste Incinerator

(Containerized Mobile Burner)

Capacity: Typical 50 kgs per hr


Design

CA50

Interior Dimensions

100 x 80 x 70 cm

Main Item List

Main Burning Chamber

Additional Burning Chamber

Smoke Filter Chamber

Burner Control Situation

Chimney:5.0 Meters

*( upgrade to Stainless-steel, cost-free price)

Italy oil/gas heater: 02 units

Oil Container (if oil fuel): 200Liters

ISO 20′ ′ Container( Delivery with Burner)














Version

CA50

Waste Treatment

Waste Incineration Therapy

Feed Capability

Typical 100 kgs per feed

Burning Price

Ordinary 50 kgs per hr

Burning Time per Feed

Standard 2 hour

Control Setting

PLC( Programmable Logic Controller Incinerator)

Voltage

220V

Power

0.7 Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Guidebook

Temperature Screen

Digital Display

Gas intake (Oil)

Typical 16.6 Kgs/Hour

Internal Dimensions

100x80x70cm (Main Chamber)

External Capacities

230 x 130 x 155cm (main body)

Waste combustion chamber

560Liters

Blog Post Combustion Chamber

280Liters

Oil Tank Capacity

200 Liters

Door Opening

70 x 50cm

Smokeshaft

5.0 M

Gross Weight

4500kgs

Chamber Product

Firebrick, Refractory Concrete

Max. Warmth Value

166,000 Kcal/Hr.

























HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-15

Medical Waste Incinerator Capacity Standard 100kgs per hour

Temperature Level Show & & PLC Control Instance

Main Burning Chamber

Incinerator Text

Italy Oil/Gas Heater

***Primary Combustion Chamber

*** Second Combustion Chamber *** Smoke Filter Chamber

***Chimney:10.0Meters

*** Burner PLC Control Instance

***Italy oil/gas burner: 02 units
***Oil Tank (if oil fuel): 200Liters


Items/Model

TS100( PLC)

Concept

Waste Incineration Treatment

Burn Price

Standard 100 kg/hour

Feed Ability

Average 200kg/feeding

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Combustion Chamber

1200L

Inner Measurements

120x100x100cm

Additional Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Mode

Manual

Voltage

220V

Power

0.7 Kw

Oil Usage (kg/hour)

14–– 28

Gas Usage (m3/hour)

10–– 32.2

Temperature Display

Digital Show

Temperature Protection

Yes

Oil Storage Tank

200L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Type

Stainless-steel

1st. Chamber Temperature Level

800 ℃–– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Exterior Measurements

260x150x180cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-16

Dual heat burners as well as double chamber burner Burning ability up to 30 Kg per hour with wet scrubber

Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour
Main Product List
Primary Combustion Chamber(Main body stainless steel)
Secondary Combustion Chamber(Main body stainless steel)
Mix-Combustion Chamber
Wet Scrubber( Washing Tower)(Main body stainless steel)
Incinerator Control Case
Chimney:5.0Meters  Stainless Steel
Italy gas burner: 02 sets
Oil Tank (if oil fuel): 100Liters

Model

YD-30C

Feed Ability

Ordinary 50 kgs per feeding

Burning Price

Typical 30 kgs per hour

Burning Time per Feed

2 hours

Voltage

380V

Power

6 Kw

Fuel

Natural Gas

Heater

Italy Heater

Feed Setting

Handbook

Gas usage (Oil)

10.2-20.0 Kgs/Hour

Gas usage (Gas)

12.2-24.0 m3/Hour

Outside Measurements

170 x 140 x 190cm (text)

Interior Measurements

55 x 55 x 85cm( Primary Chamber)

Waste combustion chamber

250Liters

Article Combustion Chamber

140Liters

Oil Tank Capacity

100 Litres

Door Opening

38 x 48cm

Chimney

5.0 M

Gross Weight

3300kgs

Chamber Material

Refractory Concrete

Max. Heat Worth

200,000 Kcal/Hr.

Operation Technical Specs

Solid Chamber temperature

8000C -10000 C

Concentration camp temperature level

10000C -12000 C

Chamber Anti-Rate

13500C

Residency time

2.0 Sec.

Burning efficiency

> 98%

Waste Lower Calorific Power

3000Kcal

Water showering cyclone air cleaner Stain less steel 304 grade sheet for water scrub chamber
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-26

hiclover waste burner extra parts

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.
Refractory cement,Ignition transformer – Secondary burner,Ignition transformer – Primary burner,Emergency push button,Temperature thermos couple with Locknut – 1600oC,Temperature thermos couple with Locknut – 1300oC,Temperature display controller – Secondary Chamber,Temperature display controller – Primary Chamber (Parameter – Digital Adjust Instrument),Burner Lighting Sensor (Photo Cell) PBT/PC
Circuit board (LM44.255C2BT) High Stage Secondary,Circuit board (LOA24.171B2BT) Primary
Fire proof flange gasket,Fire proof flange gasket
CA50-600,EB14HPM,26-48-3371T JT04,K1600,k1300,XMT – 3000,XMT – 2000 QRB1,LM44.255C2BT,LOA24.171B2BT,SN834457 8023020001,SN834451,3713798,AS47B,FO03,BTL20,SPARK35
Ignition electrode with leads(for burner BTL20/SPARK35),Solenoid(for burner BTL20/SPARK35),Burner fuel pump(for burner BTL20/SPARK35),Fuel filter(for burner BTL20/SPARK35)
Burner – Baltur,Burner – Baltur,Solenoid,Burner fuel pump
Ignition Cable,Ignition Switch -(Control Box),Photo Cell
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-06

Containerized Mobile Burner Pre-assembled, containerized type

Version

CA100

Photo

Waste Therapy

Medical Waste Incineration Therapy

Feed Ability

Ordinary 100-200 kgs per feed

Burning Rate

Typical 100-120 kgs per hr

Burning Time per Feed

Standard 1-2 hr

Control Setting

PLC( Programmable Logic Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Fuel

Diesel oil

Burner

Italy Heater

Feed Mode

Handbook

Temperature Monitor

Digital Display

Fuel intake (Oil)

Typical 20.4 Kgs/Hour

Interior Measurements

100x80x70cm (Main Combustion Chamber)

External Dimensions

230 x 130 x 155cm (main body)

Waste burning chamber

560Liters

Blog Post Burning Chamber

280Liters

Oil Tank Capacity

200 Litres

Door Opening

70 x 50cm

Chimney

5.0 M

Gross Weight

4500kgs

Chamber Product

Firebrick, Refractory Concrete

Max. Warm Worth

166,000 Kcal/Hr.

Procedure Technical Specs

Solid Chamber temperature

8000C -10000 C

Concentration camp temperature

10000C -12000 C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning effectiveness

> 98%

Waste Lower Calorific Power

3000Kcal

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-20

Incinerator A2400



Basic Info.

Model NO.:A2400
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, medical waste incinerators manufactures and suppliers, medical waste incinerators vs animal crematory, medical waste incinrators in china, medical waste italy, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chmaber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree

Pyrolytic Dual Chamber Incinerator Small Size : Burning Price : 30-45 kg/hr ; Optimum Load Capability : 400 kg

Items/Model

TS50( PLC)

Picture

Principle

Strong Waste Incineration

Burn Price

30-45 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

560L

Inner Measurements

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

220V

Oil Intake (kg/hour)

Typical 13.3

Gas Consumption (m3/hour)

***

Temperature Display

Digital Show

Temperature Level Defense

Yes

Oil Storage Tank

800L

Feed Door

70x55cm

Chimney

5Meter

Chimney Kind

Stainless Steel

1st. Chamber Temperature Level

800 ℃– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

Exterior Measurements

230x130x155cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Tool Dimension : Burning Rate : 60-80 kg/hr Pyrolytic Double Chamber Incinerator

Items/Model

TS100( PLC)

Photo

Concept

Waste Incineration Treatment

Burn Price

60-80 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Combustion Chamber

1200L

Interior Measurements

120x100x100cm

Second Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Setting

Manual

Voltage

220V

Oil Consumption (kg/hour)

Typical 20.4

Gas Intake (m3/hour)

***

Temperature Monitor

Digital Present

Temperature Level Defense

Yes

Oil Container

1100L

Feed Door

80x60cm

Smokeshaft

10Meter

Chimney Kind

Stainless Steel

1st. Chamber Temperature

800 ℃– -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

External Dimensions

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21

Plus Size Burning Price : 150-200 kg/hr Solid Waste Devices Primary and Second Combustion Chamber Burner

Items/Model

TS500( PLC)

Picture

Concept

Waste Incineration Treatment

Burn Price

150-200 kg/hour

Control Setting

PLC( Programmable Logic Controller Burner)

Combustion Chamber

2700L

Interior Dimensions

190x120x120cm

Second Chamber

1300L

Smoke Filter Chamber

Yes

Feed Mode

Handbook

Voltage

220V

Oil Intake (kg/hour)

Ordinary 28

Gas Usage (m3/hour)

***

Temperature Display

Digital Display

Temperature Security

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃– -1000 ℃

2nd. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

15000kg

Outside Measurements

400x210x300cm( without chimney)

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21