Tag: waste-incinerator

High Temperature Incineration Process HICLOVER YD30

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Model YD-30 
Burning Rate  average 30 kgs/hour
Feed Capacity average 40 kgs
Paimary Combustion Chamber 200 Liters
Secondary Combustion Chamber 100 Liters
Mix Combustion Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.59Kw
Fuel Type Diesel Oil
Burner Italy Original
Oil Consumption (Diesel Oil) average 13.3 kg/hour
Gas Consumption (Natural Gas) ***
Internal Dimensions 80 x 50 x 50cm (paimary chamber)
External Dimensions 125 x 90 x 180cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 60 Liters
Door Opening 40 x 40cm
Chimney Length 1.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 1000 kgs



what is incineration
what is the cost of building incenerator in uganda
3d drawing of incinerator

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

Medical Waste Incinerator for covid19 waste 100-150-300-500kgs per hour

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

● Double Combustion Chambers
All waste incinerator design with double combustion chamber. High Temperature, Smoke Treatment,No black smoke, Environmentally friendly. 
● Containerized Mobile Incinerators
The incinerator mounted in ISO Container before leave factory, free-installation, no incineration house build construction,movable by truck. 
● Family Pets Dog&Cat Cremation
Special design with movable platform, combustion chamber material and custom made for pets crematory business. 
● Installation and Commissioning
Clover’s engineers install,train for most of the region and free-cost train in our factory. 


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Optional Optional Optional Optional

Smoke Wet Scrubbers

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm


hospital incinerator ash
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

450x210x300cm

 

Medical Waste Incineration Model TS20(PLC) Wet Scrubber (Water Spary tower)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items/Model

TS20(PLC)

Picture

 

Principle

Medical Waste Incineration 

Burn Rate

Average 20 kg/hour

Feed Capacity

Average 40kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

210L

Internal Dimensions

65x65x50cm

Secondary Chamber

110L

Smoke Filter

Wet Scrubber (Water Spary tower)

Feed Mode

Manual

Voltage

380V

Power

5Kw

Oil Consumption (kg/hour)

7.8–16.3

Gas Consumption (m3/hour)

8–15.7

Temperature Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

100L

Feed Door

45x40cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st.

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

4000kg

External Dimensions





HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

160x110x130cm(Incinerator)

 

Integrated Solid Waste Management System medical waste incinerator

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


Capacity: Average 300 kgs per hour

Model

YD–300

Picture

 

Burning Rate

Typical 300 kgs/hour

Feed Capacity

Average 500 kgs/feeding

Main Combustion Chamber

2400 Liters

Secondary Combustion Chamber

1200 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Wet Scrubber System(3 Part Type)

Feed Mode

Manual

Voltage

380V

Power

12.0 Kw

Fuel Type

Diesel Oil/ Organic Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Typical 33kg/hour

Gas Consumption (Natural Gas )

***

Internal Dimensions

220 x 110 x 100cm (primary chamber)

External Dimensions

260 x 220 x 420cm (without chimney/wet scrubber)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

500 Liters

Door Opening

90 x 110cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

14000 kgs

Operation Technical Specifications

Main Chamber Temperature

800℃–1000℃

Secondary Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Burning Efficiency

>98%

Waste Lower Calorific Power



3000Kcal

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy. 

 

Medical Waste Incinerators for Clinics and Small Hospitals

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Item

Serie No.

SN

 Item

Specification

1

Model

TS100

2

Burning Rate

Ave.50-100Kgs/Hour

3

Feeding Capacity

Ave.200Kgs/Feeding

4

Main Chamber

1000 Liters

5

Secondary Chamber

540 Liters

6

Chimney

Yes

7

Wet Scrubber

Yes

8

Wet Scrubber Parameter

Dia. 100cm Hight 2500cm

9

Feeding Model

Manual

10

Power

380V 3P 50Hz

11

Power

6.0 Kw

12

Fuel Type

Diesel Oil

13

Burner

Italy

14

Oil Consumption (Diesel Oil)

Typical 20.4 Kgs/Hour

15

Internal Dimensions Main Chamber

120 x 100 x 90 cm

16

External Dimensions (Main Body)

270 x 190 x 170cm

17

Temperature Monitor

Yes

18

Oil Tank (Daily)

1.8M3

19

Oil Tank(Deposit) Parameter

10M3, Dia. 200cm Length 3500cm

20

Feeding Door

80 x 60cm

21

Chimney

6.0 M

22

Chimney Material

S.Steel

23

Weight

Ave.8500Kgs

24

1st. Chamber Temperature

1000℃-1200℃

26

Residency Time

2Sec.

2020-07-27

Part Name

Packing List

1#

Incinerator Mainbody

 

2#

Oil Tank(Deposit)

 

3#

Oil Tank(Daily)

 

4#

Chimney(Vertical,High Temperature)

 

5#

Chimney(Flat,High Temperature)

 

6#

Wet Scrubber

 

7#

Chimney(S shape)

 

8#

Chimney(Below)

 

9#

Chimney(Top)

Hospital Incinerators for Medical Waste Destruction


 

2020-07-27

Small Medical Waste Incinerator 2 combustion chambers with scrubber

Small Medical Waste Incinerator 2 combustion chamber with scrubber for Virus medical waste

On-Site Incineration Solution‎

Medical waste incineration involves the burning of wastes produced by hospitals, veterinary facilities, 
and medical research facilities. These wastes include both infectious (“red bag”) 
medical wastes as well as non-infectious, general housekeeping wastes.

Items/Model

TS30(PLC)

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

2020-07-27

Nanjing Clover Medical Technology Co.,Ltd.

Secondary Chamber
4000kg
Yes
Feed Door
Oil Tank
2nd. Chamber Temperature
Power
Average 11.7
Residency Time
Gross Weight
External Dimensions
Combustion Chamber
Burn Rate
 
Stainless Steel


 

HICLOVER Waste Incinerator 10-500kgs/Hr.Double Combustion Chambers

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor



Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Feed Door

80x60cm

80x60cm

 

 

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2020-07-27

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration

General Waste Incinerator

For MSW

Mobile Incinerator(Optional)

Small-Middle scale, cellular function by

1. ) Wheel

2.) 3 Sections Wet Scrubber

1 Section Wet Scrubber

S.S304 Cooling Spray tower

3 Sections Wet Scrubber

1.) S.S304 Cooling Spray tower

2.) S.S304 Dust Scrubber

3.) S.S304 Fog and Water Separator

Feeding Door

1.) Front/Side Manual Loading

2.) Top Feeding Door(Optional)

3.) Auto. Feeding Door(Optional)

3rd Combustion Chamber(Optional)

 

Stainless Steel Main Body(Optional)

S.S201 or S.S304

Control Model

1.) Electric control box(Semi-automatic)

2.) PLC Auto.control box(Automatic)

 

Light Weight Upgrade(Optional)

 

W2E(Waste to Energy)(Optional)

Hot Water(Non-drinking water)

Fuel Burner

Italy Baltur Brand

4.) Both D.O and N.G/LPG(not 2in1 burner, exchange burner type)

Temperature Thermocouple

1.) K Type,Stainless Steel 1300(Standard)

2.) K Type,Corundum 1300(Optional)

3.)  S Type,Platinum Rhodium 1600(Optional)

Control Case Material

1.) Steel (Standard)

2.) Stailess Steel(Optional)

 

Chimney/Stack

1.) Stailess Steel (Standard)

2.) Steel(Optional)

3.) Length(Optional)

4.) Thickness(Optional)

300x160x190cm

400x210x300cm

450x210x300cm

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

2020-07-27

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste

Needle Incinerator(Needle & Syringe Destroyers) and Micro Incinerator for COVID 19 waste.



HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

Smallest Waste Incinerator for PPE waste face mask glove waste

Smallest Waste Incinerator for PPE waste face mask glove waste
Ave 400kgs for shipping, 1 chamber, 1 burner ,1 air fan, 1 control box, 1.5Meter chimney
ave 10kgs per hour, 100kgs per day(10hr/day working)

Equipment Technical Specifications

Model

YD-10

Picture

 

Feed Capacity

Typical 20 kgs per feeding

Burning Rate

Typical 10 kgs per hour

Burning Time per Feed

2 hours

Voltage

220V

Power

0.5Kw

Fuel

Diesel oil

Burner

Italy Burner

Feed Mode

Manual

Fuel consumption (Oil)

Ave. 4.2 Kgs/Hour

External Dimensions

Dia.100 x 130cm (mainbody)

Internal Dimensions

Dia.50 x 80cm

Waste combustion chamber

200Liters

Oil Tank Capacity

100 Liters

Door Opening

35 x 35cm

Chimney

1.5M

Gross Weight

Ave.400kgs

Chamber Material

Refractory Concrete&Ceramic Fiber 

Max.

42,000Kcal/Hr.

Operation Technical Specifications

Chamber temperature

8000C -10000C

Chamber Anti-Rate

14000C

Burning efficiency

>98%

Waste Lower Calorific Power

3000Kcal

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


 

Incinerator YD-150 with Stainless Steel Wet scrubber-Cooling Spray tower

Model

YD-150

Burning Rate

Average 150 kgs/hour

Feed Capacity

Average 300 kgs/feeding

Main Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V/380V

Power

1.03Kw

Fuel Type

Diesel Oil/ Organic Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

17–36 kg/hour

Gas Consumption (Natural Gas )

11–36.7 m3/hour

Internal Dimensions

150 x 100 x 96cm (primary chamber)

External Dimensions

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

before start the 2nd burner, full close all air valve on the 1st chamber. other operation keep same. 
reason: at the first 10-20 min burnning the plactic waste, deflagration combustion in the chamber. 
after 10-20 min, gradually increase air injection by air valve on the 1st chamber.
meanwhile, proposal 20-30 min burnning of the 1st chamber, stop the 1st burner(stop fire only, the fan inside the burner 
still working), let the plastic burn itself(Spontaneous combustion) to save diesel oil.
a small waste to energy project to turn municipal solid waste 

7500 kgs

Model

YD-150

Main Product List

Main Combustion Chamber

 

Secondary Combustion Chamber

 

Mix-Combustion Chamber

 

Smoke Filter Chamber(Dry Scrubber)

 

Incinerator Control Case(PLC Auto.Type)

 

Chimney:10.0Meters

*(upgrade to Stainless Steel, free cost)

 

Italy oil/gas burner: 02 sets

 

Oil Tank (if oil fuel): 300Liters

 

Optional Part:

Stainless Steel Wet scrubber(Cooling Spray tower)

into electricity. The project is to cater for a local council with a population of around 60,000 people and will serve as a 
pilot project. If project is successful than other such plants will be installed in other towns and villages. The villages 
will all cater for the MSW in their locality instead of a central large incineration plant to cate for the whole county.for a 7 ton per 
hour plant on turn-key basis with your best price and delivery including full technical specifications, literature, drawings 
and best export price.
Provided you can offer a good solution there is a chance of selling many more such plants for the local councils of the same 
country, so this is an excellent chance for you to join forces with our company for market penetration with your products in 
Europe.
1. TS100 model with dry scrubber system
2. YD150 with a wet scrubber system

 

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.