Medium Scale Solid Waste Incinerator

Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel…

Items/Model

TS150(PLC)

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*(50/100/200kgs/hour optional)

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Average 20.4-28.0(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

Containerized Incinerator Model CA30 from HICLOVER

Containerized Incinerator is one type of mobile incinerator. we build the incinerator and mounted the incinerator into shipping container(20′ container or 40′ container), with necessary Basic work, such as flooring, lighting, wiring, etc.

Items/Model

CA30

Picture

Burn Rate

Average 10 kg/hour

Feed Capacity

Average 30kg per feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

330L

Internal Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

Average 13.3

Gas Consumption (N.G, m3n/Hour)

Average 16

Gas Consumption (L.P.G, m3n/Hour)

Average 11.7

Temperature Monitor

Four Digital Display

Temperature Protection

Yes

Oil Tank

100L or More(Optional)

Feed Door

55x50cm

Chimney

5Meter or More(Optional)

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

4000kg(without container)

External Dimensions

175x120x140cm



 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

Incinerator Video

Key Features:
— Full range incinerator with Economized Small Scale incinerator, 
Standard Small-Large Scale incinerator, General Municipal Solid Waste Incinerator, 
Pet and Animal Cremation, Containerized Mobile Incinerator, High Efficient Environmental Waste Incinerator.
— Single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion chambers waste incinerators.
— System solutions for medical waste environmental.
— High burn rate, from 5kgs to 1000kgs per hour.
— New Design for pet animal cremation business.
— HICLOVER, trusted partner with years of experience.



 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

50-100-150-200 Kgs per Hour Solid Waste Incinerator Model TS150 PLC 1570Liters Chamber

Waste Incinerator Model TS150 PLC, Overview


This model is small-scale waste incineration equipment for small waste output. 

Construction is dual/double combustion chamber with 02 sets oil burner, batch load 
incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. 
Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.


Primary Combustion Chamber: 

※Main Feature:

— Double Combustion Chamber
— Double Italy Burner
— Smoke Filter included
–Burning Rate: 50-200kgs per hour optional
–Primary Combustion Chamber: 1.57M3(1570Liters)
— Incinerator Mainbody steel: 8mm thickness 
— Paint for outside face: 800°C Rate

Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate
— Idea for campsite average or below 600 people

— Chimney: 10 Meters, Stainless steel


Feeding door primary chamber:


Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*(50/100/200kgs/hour optional)

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Average 20.4-28.0(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)




 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

50-100-150-200 Kgs per Hour Solid Waste Incinerator on Sale

Waste Incinerator Model TS150 PLC, Overview


This model is small-scale waste incineration equipment for small waste output. 

Construction is dual/double combustion chamber with 02 sets oil burner, batch load 
incineration equipment. Waste feed chamber is 1570Liters (1.57m3, TS150 PLC). 
Primary & Secondary combustion chambers and smoke filter chamber. 
Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation.


Primary Combustion Chamber: 

※Main Feature:

— Double Combustion Chamber
— Double Italy Burner
— Smoke Filter included
–Burning Rate: 50-200kgs per hour optional
–Primary Combustion Chamber: 1.57M3(1570Liters)
— Incinerator Mainbody steel: 8mm thickness 
— Paint for outside face: 800°C Rate

Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate
— Idea for campsite average or below 600 people

— Chimney: 10 Meters, Stainless steel


Feeding door primary chamber:


Items/Model

TS150(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 150 kg/hour

*(50/100/200kgs/hour optional)

Feed Capacity

Average 750kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Main Body Steel

8mm thickness

Chamber Material

High Alumina Fire Brick Wall, 1750℃ Rate

Paint for outside face

800°C Rate

Combustion Chamber

1570L

Internal Dimensions

150x100x105cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/230V 50/60Hz

Power

0.9Kw

Oil Consumption (kg/hour)

Average 20.4-28.0(D.O)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x280cm(without chimney)




 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

Waste Incineration Treatment Model TS75(PLC)

Average 50-100 kg/hour Burn Rate


 

Items/Model

TS75(PLC)

Principle

Waste Incineration Treatment

Burn Rate

Average 50-100 kg/hour

Feed Capacity

Average 200-300 kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Face Oil Paint

800

Combustion Chamber

768 Liters (0.768M3)

Internal Dimensions

1200x800x800mm

Secondary Chamber

384 Liters (0.384M3)

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/240V 50Hz 1P

Power

1.3Kw

Oil Consumption (kg/hour)

Average 20.4(D.O)

Thermal capacity(kw/hour)

166-332

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Oil Tank

3000L

Feed Door

60x50cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

7500kg

External Dimensions

260x160x250cm(without chimney)

We supply single combustion chamber, double combustion chambers, three combustion chambers and multi-combustion 

chambers waste incinerators for laboratory, clinic, hospital, medical center, hygiene clinical waste destruction with medical 

disposable, biological waste, medical plastic waste, hazardous waste, red bag waste, needle disposal, gauze and bandages, 

sealed sharp containers, pathological waste, trace-chemotherapeutic wastes, etc.

      

Our range of incinerators cater for small to large scale animal cremation related businesses, such as poultry farms, cattle 

farms, sheep farms, pig farms, stables, kennels, testing laboratory, catteries, pet crematoriums.

The incinerator burn waste in primary combustion chamber and burn the smoke from primary combustion chamber again to 

make sure environmentally friendly with no black smoke, smelless, reduce pathogenic bacteria infection.

System solutions for medical waste environmental, including waste incineration, smoke emission treatment, high-temperature 

sterilization, ultraviolet sterilization lamp, waste shredder, needle destroyer, medical waste package, sharp containers, etc.

The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation 

business owner all over the world.

The containerized mobile incinerator mounted in ISO container before leave factory, pre-installation, no incineration house 

build construction, movable by truck and ultraviolet lamp sterilization inside.

We are growing brand for environmental protection field, and market share with most of 

Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental 

organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. 

We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan.

We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, 

supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, 

pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory 

incinerator. 

250kgs per hour capacity waste incinerator

Incinerator Model TS250 PLC, Overview

This model is small-scale waste incineration equipment for small waste output. Construction 

is dual/double combustion chamber with 02 units oil burner, batch load incineration equipment. 
Waste feed chamber is 1800Liters (1.8m3, TS250 PLC). Primary & Secondary combustion chambers
and smoke filter chamber. Batch load on the bottom of chamber. Incinerator PLC panel control suit for local operation. 

Main Product List per 01 set

Primary Combustion Chamber

Secondary Combustion Chamber

Smoke Filter Chamber

Incinerator PLC Control Case

Chimney:10.0Meters

*(upgrade to Stainless Steel, free cost)

Italy oil/gas burner: 02 units

Oil Tank (if oil fuel): 300Liters








Items/Model

TS200(PLC)

Picture

 

Principle

Solid Waste Incineration Treatment

Burn Rate

Average 250 kg/hour

Feed Capacity

Average 350kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

1800L

Internal Dimensions

150x110x110cm

Secondary Chamber

750L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.9Kw

Oil Consumption (kg/hour)

Average 28

Gas Consumption (m3/hour)

Average 33.6

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

300L

Feed Door

80x60cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

8500kg

External Dimensions

300x160x190cm

Burner operation should be Automatic On/Off

Fuel : diesel

The supplier must provide  necessary information for the best of  the installation

This incinerator with “PYROLYTIC” combustion must have:

;

・ Refractory concrete :

§ . Thickness : ≥100 mm

§ . Nature: 42% of Al203

・ Insulate in fibrous panels :

§ . Thickness: ≥75 mm

・ Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.

 

A chamber of post combustion of gases

* A burner of combustion of gases,

* A device of injection of air allowing a total recombustion of gases,

* A device of air inlet of cooling of waste gases,

* A sheath of evacuation of the gases burnt.

* Carcass in strong sheet steel with support of connection.

* Composition of the refractory;

・ Refractory concrete :

§ Thickness : ≥150 mm

§ Nature: 65% of Al203

・ Insulate in fibrous panel :

§ Thickness: ≥85 mm

 Nature: Calcium



incinerator manufacturer 200kgs/h

Waste is thermally decomposed in the primary chamber at temperatures of 800 °C +. The resulting gaseous products are completely oxidized in the secondary chamber at higher temperatures with sufficient resident time. Other specifications are as follows. A combustion chamber of waste:

* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load

* A burner of lighting which the use is limited to the ignition of waste.

* Frontage of loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.

* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminum and insulates bricks in order to assure a minimum temperature on   the outside sheet metal.

* Composition of the refractory


Burning Capacity

Max. 200kgs/h

Auxiliary Fuel

Diesel

Type of Burner

Monoblock automatic burners

Temperatures

Primary Chamber: 800°C ± 50°C

Secondary Chamber: 1300°C ± 50°C

Type

Static solid hearth

Material of Construction

Mild Steel

Refractory thickness

115 mm thick

Material

Refractory bricks

Insulation thickness

50 mm thick

Waste Charging

Manual

Ash Removal

Manual

Type

Static solid hearth

Material of Construction

Mild Steel

Refractory thickness

115 mm thick

Material

Refractory bricks

Insulation thickness

50 mm thick

Type

Centrifugal

Modulation

Manual damper control

Material of Construction

Mild Steel

Type of temperature controller

Digital

Finish & painting type

Double coat

Material of construction & capacity

Mild Steel/ Plastic, suitable capacity

Other Standard Accessories

Diesel oil level indicator, piping with valves & Non-return valve

Visual Checking of Fuel

Provided

No. of Burners

2 one in primary and in secondary chamber)

Type & Model

Monoblock automatic oil fired

Make

Riello

Fuel

Diesel

Fuel delivery

10 C 20 kg/h

Firing stage

1

Thermal power

118 C 236 kW

Motor power

240 W

Pump pressure

10 C 12 bar (standard calibration), Max. pressure 15 bar

Electrical supply

Single phase 220V, 50Hz.

Material of construction

Burnt bricks

Height

9 meters from ground level

Containerized Mobile Type Medium Unit Waste Incinerator

Medium Unit – to handle an average waste production of 500 kg/day.Minimum load capacity: 600 kg.Maximum load capacity: 1,000 kg.Nominal burning rate: 55-80 kg/hr (= 440 C 640kg range per 8hour day).

Items/Model

TS50(PLC)

Picture

 

Principle

Waste Incineration Treatment

Burn Rate

Average 50-100 kg/hour

Feed Capacity

Average 200-300 kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Optional Upgrade Containerized Mobile Type Incinerator

ISO 20′ Full Container

Combustion Chamber

560L

Internal Dimensions

1000x800x700mm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

210/240V 50Hz 1P

Power

1.3Kw

Oil Consumption (kg/hour)

Average 20.4(D.O)

Thermal capacity(kw/hour)

166-332

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Oil Tank

1000L

Feed Door

60x50cm

Chimney

10Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

7500kg

External Dimensions

260x160x250cm(without chimney)