UNAMID supports its dependants via the operation of several self-sustained camps located across the mission AOR. These camps contain all elements representative of small communities. These communities include hospitals and medical facilities, power generation stations, grocery shops, kitchen and dining facilities and large scale use of packaged material in plastic, cardboard and similar. The waste generated in these camps are therefore representative of average small communities without heavy industry. The main objective of this document is to provide potential bidders with necessary information to supply the large capacity containerized incinerators to UNA M I D as described in subsequent clauses.
1. Medical waste incinerator – Small
2. Medical waste incinerator – Medium
3. General waste incinerator – Small
4. General waste incinerator – Medium
5. General waste incinerator – Large
5. General waste incinerator – Large with automated feeding system
Supply of Medical and General waste incinerators
FOR THE PROVISION OF
LARGE CAPACITY CONTAINERIZED INCINERATOR AND ACCESSORIES
The proposed incinerators shall be built into standard 20ft lSO contai ners or alternatively built into similar footprint complete with ISO load handling facil ities (hooks噜 eyelets, etc). The number of conta iners/container sized modules required for each unit is at the discretion of the Contractor.
•Thermocouple
•temperature gauge
•fire rope
•burn er
•induction air fan
•digital temperature display panel
The incinerator combustion chamber(s) should be designed for easy maintenance of all internal parts including the refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also be protected against oxidation, corrosion , etc. The incinerator shell shall be made of mild steel with an adequate thickness (minimum 15 mm) and painted externally with heat resistant aluminium paint suitable to withstand 250 °C. The outside surface temperature of the incinerator casing should not exceed 50 °C above ambient temperature and shall include a safety mesh around all hot surfaces. Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.
•Heavy steel construction.
•Fixed hearth geometry and starved air gasification operationa l mode.
•Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm.
•Cold face refractory lining of calciu m si l icate or superior material, minimum thickness 100mm.
•Refractory lining of all the ducts shall be done with refractory castings. Su perior quality ceramic wool shall be used at all hot duct flanges and expansion j oints.
•Multi ple electric ignition fuel bu rners designed to use automotive d iesel fuel.
•Flame of the primary burner shall be oriented towards the center of the uni t which does not impinge directly on the refractory floor or wall. The secondary burner shall be positioned in such a way that the flue gas passes through the flame.
•The unit shal l prevent leakage of the hot flue gas and any backfire.
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator
Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. animal incinerators is the way forward for Bio-secure waste disposal. Modern incineration is recognized as a most efficient solution for significant risk reduction in animal waste management.
HICLOVER is currently offering a broad selection of medical waste incinerators, designed to provide efficient waste destruction, using best available technologies and environmentally friendly procedure. Due to the secondary room with its 2 minute retention period, our healthcare incinerator range is well suited to process clinical waste.
Our products guarantee effective, clean and hassle-free disposal of medical waste is possible. The incineration of clinical waste such as pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies, Medication Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste.
Items/Model
TS100(PLC)
TS150(PLC)
TS300(PLC)
TS500(PLC)
Burn Rate (Average)
100 kg/hour
150 kg/hour
300 kg/hour
500 kg/hour
Control Mode
PLC Auto.
PLC Auto.
PLC Auto.
PLC Auto.
Combustion Chamber
1200L
1500L
2000L
3000L
Internal Dimensions
120x100x100cm
150x100x100cm
170x120x100cm
210x120x120cm
Secondary Chamber
600L
750L
1000L
1500L
Smoke Filter Chamber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Feed Mode
Manual
Manual
Manual
Manual
Voltage
220V
220V
220V
220V
Electricity
1.38Kw
1.69Kw
2.57Kw
4.88Kw
Diesel Oil Consumption (kg/hour)
Ave.20.4
Ave.24.2
Ave.33
Ave.44
Natural Gas Consumption (m3n/hour)
Ave.24.5
Ave.29
Ave.39.6
Ave.52.8
Infection Monitor
Yes
Yes
Yes
Yes
Temperature Protection
Yes
Yes
Yes
Yes
Oil Tank
200L
300L
500L
500L
Feed Door
80x60cm
80x60cm
Chimney
10Meter
10Meter
14Meter
14Meter
Chimney Form
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
1st. Chamber Temperature
800℃–1000℃
800℃–1000℃
800℃–1000℃
800℃–1000℃
2nd. Chamber Temperature
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
Residency Time
2.0 Sec.
2.0 Sec.
2.0 Sec.
2.0 Sec.
Gross Weight
6000kg
8500kg
11000kg
16000kg
External Dimensions
260x150x180cm
300x160x190cm
400x210x300cm
450x210x300cm
Type of waste: medical and industrial (solid and semi solid hazardous)
Type of waste : Bio-medical & Hazardous (Solid and Semi Solid)
If you are a hospital then Please also tell how many bedded hospital : No aren’t a hospital
Quantity of waste generated per day in kg : 6000 kg
Duration C incinerator will be used per day :1 C 16 hours
Approximate moisture content: 47 to 53%
Availability of power and type : 3 Phase, 440 Volts
Details of space available : Min. 10000 Sq. ft.
Do you require an automatic loading system? Depends if it is a continuous burning or interval burning.
How soon do you require the system to be delivered? 8 weeks
Whether the location is a coastal area : No
An other specific requirements: Automatic PLC Control System.
Burning Rate: 500kg/hour
Volumetric capacity Primary Chamber: 500kg
Burner Type: Diesel Operated
Burning Process: Continuous
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator
Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. Incineration is the way forward for Bio-secure waste disposal. large animal incinerators is recognized as a most efficient solution for significant risk reduction in animal waste management.
All kindly pets owners hope their lovely dog or cat be in heaven after they leave us. We understand the special bond between pet and owner and believe that it should never be forgotten. Losing a pet can be devastating and we built our business so families can remember their pets forever. pet incinerators are cremation equipment for family dead pets, including cat, dog and small pig, etc.