Tag: incinerator

Medical Waste Burner Capability Requirement 100kgs per hr



Temperature Level Show & & & & PLC Control Instance

Main Burning Chamber

Incinerator Text

Italy Oil/Gas Heating Unit

***Primary Combustion Chamber

*** 2nd Burning Chamber *** Smoke Filter Chamber

***Chimney:10.0Meters

*** Heater PLC Control Circumstances

***Italy oil/gas burner: 02 units
***Oil Tank (if oil fuel): 200Liters


Items/Model

TS100( PLC)

Principle

Waste Incineration Therapy

Melt Cost

Standard 100 kg/hour

Feed Capacity

Average 200kg/feeding

Control Mode

PLC( Programmable Thinking Controller Incinerator)

Burning Chamber

1200L

Inner Measurements

120x100x100cm

Extra Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Mode

Guidebook

Voltage

220V

Power

0.7 Kw

Oil Usage (kg/hour)

14—- 28

Gas Usage (m3/hour)

10—- 32.2

Temperature Display

Digital Program

Temperature Defense

Yes

Oil Tank

200L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Level

800 ℃—- -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Outside Measurements

260x150x180cm

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-16



Twin heat heaters in addition to dual chamber heater Burning capability up to 30 Kg per hr with wet scrubber



Dual heat burners and dual chamber incinerator Burning capacity up to 30 Kg per hour
Main Product List
Primary Combustion Chamber(Main body stainless steel)
Secondary Combustion Chamber(Main body stainless steel)
Mix-Combustion Chamber
Wet Scrubber( Washing Tower)(Main body stainless steel)
Incinerator Control Case
Chimney:5.0Meters  Stainless Steel
Italy gas burner: 02 sets
Oil Tank (if oil fuel): 100Liters

Model

YD-30C

Feed Ability

Ordinary 50 kgs per feeding

Burning Cost

Common 30 kgs per hour

Burning Time per Feed

2 hours

Voltage

380V

Power

6 Kw

Fuel

Natural Gas

Heating Unit

Italy Heating Unit

Feed Setting

Manual

Gas usage (Oil)

10.2-20.0 Kgs/Hour

Gas usage (Gas)

12.2-24.0 m3/Hour

Outside Measurements

170 x 140 x 190cm (text)

Inside Measurements

55 x 55 x 85cm( Main Chamber)

Waste burning chamber

250Liters

Post Combustion Chamber

140Liters

Oil Tank Ability

100 Litres

Door Opening

38 x 48cm

Chimney

5.0 M

Gross Weight

3300kgs

Chamber Product

Refractory Concrete

Max. Warm Well Worth

200,000 Kcal/Hr.

Operation Technical Specifications

Solid Chamber temperature

8000C -10000 C

Concentration camp temperature degree

10000C -12000 C

Chamber Anti-Rate

13500C

Residency time

2.0 Sec.

Burning performance

> 98%

Waste Lower Calorific Power

3000Kcal

Water showering cyclone air cleaner Stain less steel 304 grade sheet for water scrub chamber

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-02-26



hiclover waste burner additional components



We are china incinerator manufacturer, contractor and exporter. Manufacturer make reasonable price for incinerator customer, supply medical incinerator, hospital incinerator, animal incinerators, hog incinerators, pet cremation equipment, small incinerator, pet incinerator, animal incinerator, portable incinerator, small animal incinerator, infectious waste pyrolysis machine, laboratory incinerator. HICLOVER help customer reduce purchase budget, custom made function, quality products and friendly service.
Refractory cement,Ignition transformer – Secondary burner,Ignition transformer – Primary burner,Emergency push button,Temperature thermos couple with Locknut – 1600oC,Temperature thermos couple with Locknut – 1300oC,Temperature display controller – Secondary Chamber,Temperature display controller – Primary Chamber (Parameter – Digital Adjust Instrument),Burner Lighting Sensor (Photo Cell) PBT/PC
Circuit board (LM44.255C2BT) High Stage Secondary,Circuit board (LOA24.171B2BT) Primary
Fire proof flange gasket,Fire proof flange gasket
CA50-600,EB14HPM,26-48-3371T JT04,K1600,k1300,XMT – 3000,XMT – 2000 QRB1,LM44.255C2BT,LOA24.171B2BT,SN834457 8023020001,SN834451,3713798,AS47B,FO03,BTL20,SPARK35
Ignition electrode with leads(for burner BTL20/SPARK35),Solenoid(for burner BTL20/SPARK35),Burner fuel pump(for burner BTL20/SPARK35),Fuel filter(for burner BTL20/SPARK35)
Burner – Baltur,Burner – Baltur,Solenoid,Burner fuel pump
Ignition Cable,Ignition Switch -(Control Box),Photo Cell

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-06



Containerized Mobile Heater Pre-assembled, containerized type



Version

CA100

Image

Waste Therapy

Medical Waste Incineration Treatment

Feed Capacity

Ordinary 100-200 kgs per feed

Burning Price

Typical 100-120 kgs per human resources

Burning Time per Feed

Criterion 1-2 hr

Control Setting

PLC( Programmable Reasoning Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Fuel

Diesel oil

Burner

Italy Heater

Feed Mode

Handbook

Temperature Level Monitor

Digital Display

Gas intake (Oil)

Regular 20.4 Kgs/Hour

Inside Measurements

100x80x70cm (Key Combustion Chamber)

External Capacities

230 x 130 x 155cm (main body)

Waste burning chamber

560Liters

Blog Site Article Burning Chamber

280Liters

Oil Storage Tank Capability

200 Litres

Door Opening

70 x 50cm

Smokeshaft

5.0 M

Gross Weight

4500kgs

Chamber Product

Firebrick, Refractory Concrete

Max.

Treatment Technical Specs

Solid Chamber temperature level

8000C -10000 C

Concentration camp temperature

10000C -12000 C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

2.0 Sec.

Burning effectiveness

> 98%

Waste Lower Calorific Power

3000Kcal

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-20



Pyrolytic Twin Chamber Incinerator Small Size : Burning Rate : 30-45 kg/hr ; Optimum Tons Ability : 400 kg



Items/Model

TS50( PLC)

Image

Principle

Strong Waste Incineration

Burn Price

30-45 kg/hour

Control Mode

PLC( Programmable Reasoning Controller Heater)

Burning Chamber

560L

Inner Measurements

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Establishing

Manual

Voltage

220V

Oil Consumption (kg/hour)

Regular 13.3

Gas Intake (m3/hour)

***

Temperature Level Display

Digital Show

Temperature Level Degree Protection

Yes

Oil Storage Tank

800L

Feed Door

70x55cm

Chimney

5Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Level Degree

800 ℃– – -1000 ℃

second. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

Exterior Measurements

230x130x155cm

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



Device Measurement : Burning Rate : 60-80 kg/hr Pyrolytic Double Chamber Burner



Items/Model

TS100( PLC)

Image

Concept

Waste Incineration Treatment

Shed Rate

60-80 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

1200L

Inside Measurements

120x100x100cm

Second Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Establishing

Manual

Voltage

220V

Oil Usage (kg/hour)

Common 20.4

Gas Consumption (m3/hour)

***

Temperature Level Monitor

Digital Existing

Temperature Level Degree Defense

Yes

Oil Container

1100L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃– – -1000 ℃

second. Chamber Temperature Level Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Outside Measurements

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



Plus Size Burning Rate : 150-200 kg/hr Strong Waste Devices Main as well as 2nd Combustion Chamber Burner



Items/Model

TS500( PLC)

Photo

Principle

Waste Incineration Therapy

Melt Rate

150-200 kg/hour

Control Setting

PLC( Programmable Reasoning Controller Heater)

Combustion Chamber

2700L

Inside Dimensions

190x120x120cm

Second Chamber

1300L

Smoke Filter Chamber

Yes

Feed Setting

Manual

Voltage

220V

Oil Intake (kg/hour)

Common 28

Gas Use (m3/hour)

***

Temperature Show

Digital Show

Temperature Level Safety And Security

Yes

Oil Tank

1400L

Feed Door

90x80cm

Chimney

10Meter

Smokeshaft Kind

Stainless Steel

1st.

Gross Weight

15000kg

Outdoors Dimensions

400x210x300cm( without chimney)

2020-03-21

400x210x300cm( without chimney)

The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The minimum combustion temperature of the primary chamber should not be less than 850°C;
The primary combustion chamber should be equipped with a means to provide supplemental liquid fuel supply.
The primary chamber should be cold face refractory lining, with a minimum thickness 100 mm.
The following conditions should be met in the secondary combustion chamber:
The air supply should be controlled efficiently;
Flame contact with all the gases should be achieved;
The size of the secondary chamber should be properly designed to ensure that the gas retention time should not be less than 2 seconds;
The secondary chamber should be cold face refractory lining, with a minimum thickness 100 mm;
The chamber should incorporate an integrated combustion burner air fans with automatically controlled distribution;
The gas temperature, as measured against the inside wall in the secondary chamber (not in the flame zone) should not be less than 1,100°C;

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-21



Mobile Cremation Instruments



Layout

CA-200

Picture

Burning Rate

Ordinary 100 kgs/hour

Key Burning Chamber

2000 Liters

Extra Burning Smokeshaft

Yes

Feed Setting

Guidebook

Voltage

220V

Power

3.0 Kw

Fuel Kind

Diesel Oil

Heater

Italy Original

Oil Use (Diesel Oil)

Normal 53 kg/hour

Inside Dimensions

230 x 100 x 90cm (key chamber)

External Dimensions

290 x 200 x 170cm (trick chamber)

Temperature Screen

Yes

Oil Container Ability( if oil gas)

500 Liters

Door Opening

90 x 90cm

Smokeshaft Size

5.0 Meters

Smokeshaft Type

Stainless-steel

Gadgets Gross Weight

9000 kgs( with container)

Procedure Technical Specs

Paimary Chamber Temperature Level

800 ℃–– – – 1000 ℃

2nd Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Performance

> 98%

Waste Lower Calorific Power

3000Kcal


Mobile crematorium 
HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-03-22



Burner for medical center waste monitoring



Heater for health care facility waste surveillance with the adhering to attributes:

– – In high temperatures( pyrolytic burner 2 chambers with temperatures varying from 950 º C to 1320 º C;

– – Capability to damage of 400 to 600kg per hr;

– – Effective in ruining germs;

– – Drain ash;

– Drain needle as well as glass crusher;

– – Patio with faucet water for hand cleaning and decontamination;

– – Observe the trouble of ecological high quality requirements, discharges proficient in addition to plan on the concern of waste; place big incinerator to among the largest veterinary university hospital in KSA so if you will certainly support us with one system (big incinerator) and also ecological with onsite training, the ability for the tool is 2000 Kg for cattle, equines as well as additionally farm animals in addition ideal to all animal waste kinds, we require it diesel fired. OES-Industrial MultiWaste Burner System (Solid/Liquid)

Level of the Job:
Style, setup along with appointing of multi hazardous waste burner.
Ability: 315 KG/HOUR STRONG WASTE/ OR 200 LITRES/HOUR FLUID WASTE (with dual chamber system).
1st chamber-870 Deg.C – – – – 900 Deg.C. Second chamber-1000 deg.C – 1200 Deg.C

Resources Of The Wastes.
The following types of wastes can be taken care of by using burner.
a). biography medical waste/pharmaceutical waste.
b). solid chemical waste/textile markets waste.
c). liquid chemical waste.
d). dyes in addition to intermediate waste.
e). all-natural chemical waste.
f). fluid ink waste/acidic deposit.
g). insecticides/herbicides/pesticides.
h). fungicide waste.
i). ethanolamine.
j). amino ethanol.
k). mono ethanolamine.
l). ETA, MEA waste.
m). wastes after treatment of chemicals in etp plant.
n). combined alcohol waste water.
o). alcoholic waste.
p). farming liquid chemical waste.
q). sludge mix fluid.
r). slurry/adhesive/grease/ powder coating wastes.
s). semi strong fluid chemical waste.
t). mass completely dry chemical waste.
u). pharma chemical wastes.
v). solvent chemicals/paint wastes/used glass grains.
w). used tires.
x). made use of cotton fabrics.
y). contaminated plastics/resin wastes.
Series of Job:.
Blaze all sorts of liquid/solid hazardous/chemical/non contaminateds products avaliable in the markets with proper scrubbing up system with typical emission rates.
The twin stage incinerator aids to burn the waste in 2 phases, initially at a tool temperature level of 870- 900 Deg C and likewise the 2nd stage at 1200 deg C.
Producing ash as well as Aeriform fumes which are treated with cyclone type wet scrubber in addition to caustic scrubber to produce air with contaminants in the enabled variety as well as Non dangerous ash mostly not natural salts.

Incinerator utilities.
Heater should have adhering to demands:.
Metallic seal framework with ceramic insulation to stay free from cozy radiation and additionally regulate radiant temperature degree.
Advanced gas treatment system to avoid discharge of dangerous gases (massaging system).
Reduced consumption high performance compact computerized burning system.
Low operating as well as maintenance rates.
Fully automatic and also very easy to operate control panel.
Afterburner Preheat.
Thick refractory concrete lining ranked at 1600 C.
Solid Hearth to make it possible for optimal Fatigue.
Large Leading opening cover for simple loading.
Wide door for ash removal.
Optional Stainless-steel Situation.
Warmth healing choice



Medical Center Waste Monitoring



Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description        Minimum Requirements
Design standard    Multiple chamber incinerator to the design of EPA  standards, Air pollution control
Description of the Chimney    Top mounted, self supporting
Incinerator performance    150kg/hr
Refuse     Hospital waste and carcasses
Recommended Temperatures    Minimum 1000⁰C
Dimensions:
Length
Width
Height
Extra width for burners    At least 3000mm
Loading door opening    Minimum 700mm x 600mm
Hearth area    5.00square meters
Description or grate/hearth    A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume    At least 3 cubic meters
Mixing chamber volume    At least 1 cubic meters
Settling chamber volume    At least 3 cubic meters
Weight excluding chimney    15, 000kg at manufacture
Firing tools supplied    Hoe, Poker and rakeMaterial of construction    Case – 5mm mild steel.
Bracing – Heavy angle and channel.
Hearth – 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Ashing door – High grade cast iron.
Loading door – 5mm mild steel lined with 1550⁰C castable  general purpose high strength, high abrasion resistant monolithic refractory concrete.
Refractory  concrete:
Alumina content of refractory
Refractory thickness
Minimum 49%
At least 127mm.
Insulation  to walls     1000⁰C Castable insulation
Chimney stack:
Chimney
Height from base    3.5 mm mild steel
9 meters above ground level and clear the highest point of the building by not less than 3 meters
At least 560mm
At least 750Kg
Controls:
Draught

Air supply

Electric

Barometric indicator, door operated draught limiter

Built-in forced heated air ducts, primary and secondary (intensifier)
Control panel – Circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer.
Electricity supply required    415 Volts Three phase.
Auxiliary  fuel    Electrically operated only
Emission     Multiple chamber design with inbuilt emission control
Paint: Case and stack    400⁰C Heat Resistant Grey
Temperature of case    100⁰C