Tag: incinerator

Hospital Medical Waste Incinerators



Model Capacity/Burnning Rate For Hospital SickBed No. Fuel Type Qty. Ready for Shipping New Production  Shipping Volume Shipping Weight Delivery Location
TS30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5 m3 3000 kgs Shanghai Port
TS50 average 50kgs per hour Average 250 SickBed Diesel Oil 1 set 7 days 20sets/2 weeks 7m3 4500 kgs Shanghai Port
TS100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 7 days 15sets/2 weeks 10m3 6000 kgs Shanghai Port
TS150 average 150kgs per hour Average 750 SickBed Diesel Oil 5 sets 7 days 15sets/2 weeks 13m3 7500 kgs Shanghai Port
YD10 average 10kgs per hour Average 50 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 3m3 1200 kgs Shanghai Port
YD20C average 20kgs per hour Average 100 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 6m3 2000 kgs Shanghai Port
YD50C average 50kgs per hour Average 250 SickBed Diesel Oil 2sets 7 days 20sets/2 weeks 7m3 2300 kgs Shanghai Port
YD30 average 30kgs per hour Average 150 SickBed Diesel Oil 1 set 5 days 20sets/2 weeks 5m3 2300 kgs Shanghai Port
YD30 Small average 30kgs per hour Average 150 SickBed Diesel Oil 2sets 5 days 20sets/2 weeks 3m3 1500 kgs Shanghai Port
YD50 average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 5 days 20sets/2 weeks 8m3 4500 kgs Shanghai Port
YD100 average 100kgs per hour Average 500 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks 13m3 6000 kgs Shanghai Port
YD150 average 150kgs per hour Average 750 SickBed Diesel Oil 1 set 10 days 15sets/2 weeks 17m3 7500 kgs Shanghai Port
YD300 average 300kgs per hour Average 1500 SickBed Diesel Oil 10sets/2 weeks 20m3 9000 kgs Shanghai Port
YD500 average 500kgs per hour Average 2500 SickBed Diesel Oil 5sets/2 weeks 27m3 13000 kgs Shanghai Port
CA 50 Mobile Containerized average 50kgs per hour Average 250 SickBed Diesel Oil 2 sets 15 days 10sets/2 weeks 28m3 7000 kgs Shanghai Port
HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-08



Clinical Waste ncinerators for Health center 10-500kgs per hr



Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity(Average) 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800–1000 800–1000 800–1000 800–1000 800–1000
2nd. Chamber Temperature 1000-1200 1000-1200 1000-1200 1000-1200 1000-1200
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm


Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 5300 kgs 7000 kgs
Picture

Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 300
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chmaber Temperature 1000-1200 1000-1200 1000-1200 1000-1200
HICLOVER – Medical Environmental 
Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Picture

Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800–1000 800–1000 800–1000 800–1000
2nd. Chmaber Temperature 1000-1200 1000-1200 1000-1200 1000-1200


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-08



Medical Burner Manufacturers in Supply all set for delivery



Medical Waste Incinerators in Stock. Twitter: https://twitter.com/hiclovercom Phone/WhatsApp/Wechat: +8613813931455, Web: www.hiclover.com Web: www.clover-incinerator.com

Double Combustion Chamber,Double Italy Burner,Smoke Filter Included,Burning Rate: 50-200kgs per hour optional,Primary Combustion Chamber: 1.57M3(1570Liters),Incinerator Mainbody steel: 8mm thickness,Paint for outside face: 800°C Rate,Chamber Material: High Alumina Fire Brick Wall, 1750℃ Rate,Idea for campsite average or below 600 people,Chimney: 10 Meters, Stainless steel…

Items/Model

TS150( PLC)

Picture

Idea

Waste Incineration Treatment

Melt Rate

Typical 150 kg/hour

*( 50/100/200kgs/ hour optional)

Feed Capability

Requirement 750kg/feeding

Control Establishing

PLC( Programmable Logic Controller Incinerator)

Text Steel

8mm density

Chamber Product

High Alumina Fire Block Wall Surface, 1750 ℃ Cost

Paint for outdoors encounter

800 ° C Price

Burning Chamber

1570L

Internal Dimensions

150x100x105cm

Second Chamber

750L

Smoke Filter Chamber

Yes

Feed Establishing

Manual

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Intake (kg/hour)

Ordinary 20.4-28.0( D.O)

Gas Intake (m3/hour)

***

Temperature Degree Present

Digital Display

Temperature Level Safety

Yes

Oil Container

300L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Level Degree

800 ℃– – -1000 ℃

2nd. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Measurements

300x160x280cm( without smokeshaft)

HICLOVER – Medical Environmental 


 

Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-04-10



Tiniest Heater 30kgs



Standard 30kgs per hr

*** Secret chamber( 200Liters)

*** 2nd chamber

*** Mix burning chamber

*** Stainless-steel smokeshaft( 1meter)

*** Italy made oil heater( 2sets)

*** Dry Scrubber

*** Weight 1.7 T( can decrease to 1.0 Lot)

Trick Spare Components( Standard for incinerator, and also price contain presently):

*** 2 collections Italy Oil Heating system

*** 2sets Temperature Level Probe

*** 1 developed Control Instance

*** 1 developed Air Follower

*** 1 established Diesel Oil Tank

*** 1 established Maintain Item



HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-24



Heater with Movable platform & & & & Car. Door as well as likewise Style for Pets Person Cremation Company



Style for Pets Cremation Service

Movable system & & & & Vehicle. Door

Independent Placement for Small Pet

Incinerator with Movable platform & Auto. Door and Design for Pets Human Cremation Business

Design

A1500

Image

Burning Rate

Typical 150 kgs/hour

Feed Capacity

Standard 350 kgs/feeding

Main Burning Chamber

1500 Liters

Second Burning Chamber

500 Litres

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Setting

Hand-operated

Voltage

220V/380V

Gas Kind

Diesel Oil/ All-natural Gas/LPG

Heater

Italy Original

Oil Consumption (Diesel Oil)

Average 53.0 kg/hour

Gas Consumption (Gas)

Average 63.6 m3n/hour

Inner Measurements

150 x 100 x 100cm (major chamber)

Outside Measurements

240 x 170 x 380cm (without chimney)

Temperature Level Show

Yes

Oil Container Capability( if oil gas)

300 Litres

Door Opening

59 x 81cm

Chimney Size

10.0 Meters

Smokeshaft Type

Stainless Steel

Tools Gross Weight

8000 kgs


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-26



50kgs/hr iraq basic waste heater with 2 burning chambers



Items/Model

TS50M

Picture

Melt Rate

Typical 50 kg/hour

Feed Capacity

Average 50-150 per feeding

Control Setting

PLC( Programmable Thinking Controller Incinerator)

Combustion Chamber

450L

Internal Measurements

75x75x80cm

Extra Chamber

225L

Smoke Filter Chamber

Yes

Feed Setting

Manual Feeding

Voltage

220V

Power

0.5 Kw

Oil Use (kg/hour)

Average 13.3

Gas Use (N.G, m3n/Hour)

Ordinary 16

Gas Intake (L.P.G, m3n/Hour)

Normal 11.7

Temperature Level Degree Show

4 Digital Present

Temperature Degree Defense

Yes

Oil Storage Tank

100L

Feed Door

55x50cm

Smokeshaft

8Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature

800 ℃–– – – -1000 ℃

secondly. Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

4500kg

Outdoors Dimensions

175x120x140cm



Incinerator Components Mineral Insulated Thermo pair sensor K-Type 300SS



Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS
K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core 

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27



General requirements of a 100 kg/hr 3 burning Chambers Burner



General specifications of a 100 kg/hr incinerator
No. Description Parameter value  
  model   HICLOVER YD100
1 Machine working mode Oil + Power Oil + Power
2 Voltage 220V C 3 phase or 1 phase 220V 1P
3 Oil consumption (lit/hr) Average 25-32 lit/hr/chamber Average 33Liters/hour/total incinerator 3 burners
6 Incineration rate 100 kg/hr = 400-600 kg/8hr average 100kgs per hour
7 Feed mode Manual manual
8 Primary combustion rate 1000 lit 1080 liters
9 Secondary combustion rate 240 lit 207 Liters
10 Tertiary combustion rate 416 lit 452 liters
11 Combustion chamber material High temp. resistant concrete High temp. resistant concrete
12 Internal dimensions (1st chamber) 100*100*100 cm (l*w*h) = 1000 lit 120*100*90cm(l*w*h) = 1080 lit
13 Internal dimensions (2nd  chamber) 40*40*150 cm = 240 lit Diameter 42*150cm=207 Liters
14 Internal dimensions (3rd  chamber) 40*40*260 cm = 416 lit Diameter 60*160cm=452 Liters
15 External dimensions 300*155*200 cm (l*w*h) 220*160*370 cm (l*w*h)
16 Door opening 90*90 cm 90*90 cm
17 Additional air fan 1 fan (on the door) 1 fan (on the door)
18 Fuel type Diesel oil/ Diesel oil
19 Burner Brand: Radiator or Hofmat Italy Baltur
20 Chimney length 3-4 meters 5 Meters
21 Chimney type and material H-type stainless steel, or High temp. resistant concrete 1 Meter High temp. resistant concrete +4 Meter Stainless steel
22 Smoke and smell filter Yes, two stages. Dry Scrubber 2 stages
23 Temperature monitor Yes, (for 1st and 3rd chambers) Yes, (all 3 chambers)
24 Temperature control Optional yes
25 Oil tank 500 lit needed. yes
26 Burning efficiency >98% yes
27 1st chamber temperature 300-700 oC 800-1000 oC
28 2nd chamber temperature 500-1000 oC 1000-1200 oC
29 3rd chamber temperature 800-1200 oC 1000-1300 oC
30 Smoke residency time >2 sec. >2 sec.
31 Gross weight 5-8 tons average 6.5 Ton
32 No. of Burners 3 3


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27



DIESEL ENDED BURNER, WITH 1000 LTR GAS STORAGE TANK As Well As 6M SMOKESHAFT



Items/Model

TS250( PLC)

Photo

Idea

Waste Incineration Treatment

Burn Price

Average 250 kg/hour

Feed Ability

Criterion 400kg/feeding

Control Establishing

PLC( Programmable Reasoning Controller Burner)

Combustion Chamber

2000L

Inner Measurements

210x88x110cm

Second Chamber

1000L

Smoke Filter Chamber

Yes

Feed Setting

Guidebook

Voltage

220V

Power

2.0 Kw

Oil Consumption (kg/hour)

Regular 24.2( DO)

Gas Consumption (m3/hour)

***

Temperature Display

Digital Present

Temperature Level Protection

Yes

Oil Tank

1000L

Feed Door

2.04 x 1.06 M

Smokeshaft

3Meter

Chimney Kind

Stainless-steel

1st.

Gross Weight

9000kg

Exterior Measurements

3.00 mx1.60 mx3.00 m (without chimney)

TWO (2) YEAR UPKEEP SPARES STRATEGY FOR LINE THING 2 X OIL DISCHARGED HEATING SYSTEM

2 X CONCRETE REPAIRING BUNDLE (25KG)

2 X THERMOCOUPLE

2 X FIRE ROPE (1M)

2 X HT MASTIC (PER BURNER)

INCINERATION IS A WASTE TREATMENT PROCESS THAT INVOLVES THE COMBUSTION OF ORGANIC SUBSTANCES CONTAINED IN WASTE MATERIALS. INCINERATION AND OTHER HIGH-TEMPERATURE WASTE TREATMENT SYSTEMS ARE DESCRIBED AS “THERMAL TREATMENT”. INCINERATION OF WASTE MATERIALS CONVERTS THE WASTE INTO ASH, FLUE GAS AND HEAT. THE ASH IS MOSTLY FORMED BY THE INORGANIC CONSTITUENTS OF THE WASTE AND MAY TAKE THE FORM OF SOLID LUMPS OR POWDER.

1 X PPE BUNDLE

2020-06-27

2 X FIRE ROPE (1M)

2 X HT MASTIC (PER INCINERATOR)

1 X PPE PACKAGE


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27



Incinerator with 1 or 3 area kind moist scrubber



Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy.  Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour capacity.

Layout

YD-150

Image

Burning Rate

Normal 150 kgs/hour

Feed Capacity

Standard 300 kgs/feeding

Secret Burning Chamber

1500 Liters

Added Burning Chamber

500 Litres

Mix Burning Chamber

Yes

Smoke Filter Chamber

Damp Scrubber System( 3 Location Kind)

Feed Setting

Manual

Voltage

380V

Power

9.0 Kw

Gas Kind

Diesel Oil/ All-natural Gas/LPG

Burner

Italy Original

Oil Usage (Diesel Oil)

Ordinary 24 kg/hour

Gas Intake (Gas)

***

Inner Measurements

150 x 100 x 96cm (primary chamber)

Exterior Dimensions

240 x 170 x 380cm( without chimney/wet scrubber)

Temperature Monitor

Yes

Oil Container Ability( if oil gas)

300 Litres

Door Opening

59 x 81cm

Chimney Size

10.0 Meters

Chimney Kind

Stainless-steel

Equipment Gross Weight

11000 kgs

Treatment Technical Specifications

Main Chamber Temperature Degree

800 ℃–– – – -1000 ℃

2nd Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Performance

> 98%

Waste Lower Calorific Power

3000Kcal

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27