Tag: incinerator

Process Engineering Design of Pathological Waste Incinerator

Basic Info.

Model NO.:small medical waste incinerator manufacturers
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can use in this equipment? 
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard 
A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity 
A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that's mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. 
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing 
A: We supply all documents and incinerators easy to installation and operation. Customer can send people come to our factory to learn installation and operation. Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order. 

Q: Combustion Temperature 
A: The first combustion chamber: 800-1000 centi degree. 
The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode 
A: Default Control mode is common control case. PLC mode according to model and order. 

Q: Operation and maintenance costs 
A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. Medical waste diesel incinerator, medical waste incinerators, mobile incinerator china, nanjing clover medical technology co., ltd., pet crematorium equipment, The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

incinerators to install on the island of Aruba

incinerators to install on the island of Aruba.
the island does not have medical waste & other waste incinerators.
we are in the process of exploring the feasabilty and setting up an incinerator facility
on the island of Aruba.
this is an island of 120.000 habitants.
we have 2 hospitals,more then 20 dentist offices,and over 50 doctor offices.
would it be possible to give us info on the capacity of incinerator we need
on this island.

Technical Requirements for Medical Waste Incinerator

Basic Info.

Model NO.:purchase pet incinerator cremator united airlines
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can use in this equipment? 
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard 
A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity 
A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that's mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. 
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing 
A: We supply all documents and incinerators easy to installation and operation. Customer can send people come to our factory to learn installation and operation. Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order. 

Q: Combustion Temperature 
A: The first combustion chamber: 800-1000 centi degree. 
The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode 
A: Default Control mode is common control case. PLC mode according to model and order. 

Q: Operation and maintenance costs 
A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, animal crematorium equipment, animal crematory bid, animal incinerater, animal waste incinerators, cattle incinerator, cheap incinerator, china incinerator exporter, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinerator

Basic Info.

Model NO.:clover medical limited china
Export Markets:Global

Product Description

YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, like hospital, mobile incinerator design, mobile incinerators, msw incinerator manufacturers, pet animal cremation equipment, pet cremation incinerator, pet cremation incinerator cost, environmental department, animal cremation agencies, etc. CLOVER Incinerator supply updated models with dual combustion chamber, mix combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Diesel Fuel Incinerator

Basic Info.

Model NO.:medical incinerator design
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What is kind of waste can use in this equipment? 
A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard 
A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity 
A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that's mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. 
*How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing 
A: We supply all documents and incinerators easy to installation and operation. Customer can send people come to our factory to learn installation and operation. Diesel oil fired medical waste incenerator, dual chamber incinerator, ecological incinerator, encenerator, farm incinerator, Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order. 

Q: Combustion Temperature 
A: The first combustion chamber: 800-1000 centi degree. 
The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode 
A: Default Control mode is common control case. PLC mode according to model and order. 

Q: Operation and maintenance costs 
A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinerators in Fiji

IT is a daily occurrence to see black smoke being emitted from the chimneys at the Colonial War Memorial Hospital in Suva.

And following a recent letter to the editor from Satish Nakched, The Fiji Times followed up with an investigation into the smoke that poses an obstruction for the nearby residents of Waimanu Rd.

A common belief is that the smoke is a product from body parts being incinerated in the hospital.

Minister of Health and Medical Services, Jone Usamate clarified “the incinerator at CWM burns all clinical waste produced at the hospital”.

“The selection of type of wastes that should be incinerated follows international standards for infection control and disposal of clinical waste,” Mr Usamate said.

Clinical waste includes blood, tissue, human organs and other body parts.

“Incineration occurs in a controlled environment where items are incinerated at a very high temperature to kill all microorganisms in the waste.

“Incinerators are used in hospitals all over the world and are the chosen method to dispose of the waste as it keeps the chances of spreading disease and infection to a minimum.”

by: http://www.fijitimes.com/story.aspx?id=334379

 

Containerized Incinerators

Containerized Incinerator incinerator house mobile incinerator

Model CA50
Feed Capacity Average 60 kgs per feed
Burning Rate Average 70 kgs per hour
Burning Time per Feed 1 hour
Voltage 220V
Power 0.7Kw
Fuel Diesel oil
Burner Italy Burner
Feed Mode Manual
Fuel consumption (Oil) Average 18 Kgs/Hour
Internal Dimensions 100x80x70cm (Primary Chamber)
External Dimensions 230 x 130 x 155cm (main body)
Waste combustion chamber 560Liters
Post Combustion Chamber 280Liters
Oil Tank Capacity 100 Liters
Door Opening 70 x 50cm
Chimney 5.0M
Gross Weight 4500kgs
Chamber Material Firebrick ,Refractory Concrete
Max. Heat Value 240,000Kcal/Hr.
Operation Technical Specifications
Solid Chamber temperature 8000C -10000C
Gas Chamber temperature 10000C -12000C
Chamber Anti-Rate 14500C
Residency time 2.0 Sec.
Burning efficiency >98%
Waste Lower Calorific Power 3000Kcal

Animal waste management plant inaugurated in Marsa

The new plant would help in reducing energy losses in the incineration process as well as reducing harmful emissions

Wasteserv inaugurated a €12 million animal waste management in Marsa earlier today.

Speaking at the inauguration of the new Wateserv EU-funded autoclave rendering plant for the treatment of animal waste, Wasteserv CEO Tonio Montebello said that the project was part of its drive to improve the country’s waste treatment infrastructure.

Montebello also explained that the plant would result in substantial savings made in the incineration plant, which processes some 6,000 tonnes of waste a year.

Projects manager Jean Luke Zarb said that the problem with the current system was that a lot of energy was being wasted in incinerating water or fats on the carcasses.

“This plant will work essentially as an industrial pressure cooker in that it will dry up the carcasses beforehand,” he said, adding that this would ultimately result in less energy required by the incinerator.

He added that the fats would also be used as fuel for the plant itself, therefore reducing its fuel consumption.

Stressing that the plant would also be used to treat materials coming from Gozo, Montebello said that the new plant would also banish issues that normally rose when the incinerator was under maintenance, ensuring a seamless transition and operation.

Environment minister Leo Brincat said that the drop in fuel consumption would also ultimately lead to less harmful greenhouse gas emissions.

“Another novelty the plant will introduce, is in expired foodstuffs containing animal by products, which would normally have to be incinerated,” he said using a pizza with meat as an example.

“The plant will allow us to treat these foods and then forward them to other treatments plants to turn them into biofuels,” he added.

Brincat said that the project would also increase Wasteserv’s overall operation, and that the company was also looking forward to the inauguration of the Malta North MBT in the coming months.

EU funds parliamentary secretary Ian Borg added that the project, 85% of which was funded by the EU, was also completed in record time – about a year.

“The government is also currently evaluating projects for the latest €200 million fund package under the European Regional Development Fund,” he said.

From: http://www.maltatoday.com.mt/news/national/61095/animal_waste_management_plant_inaugurated_in_marsa#.VqX95lK-LmK

Made-in-Vietnam waste incinerator shows its power

Made-in-Vietnam waste incinerator shows its power

VietNamNet Bridge – The waste incinerator of Vietnamese inventor Trinh Dinh Nang has been used in Bac Kan, Tuyen Quang and Thanh Hoa. But if it is used in other provinces as well, and therefore, can be produced on a large scale, the production costs will be much lower.

Nang’s waste incinerator was displayed at the Vietnam 2015 International Equipment and Technology Trade Fair, which caught the attention from many visitors.

He began working on such an incinerator some years ago, encouraged by the idea that his incinerator may help reduce the negative impact caused by hundreds of tons of medical waste.

In 2009, after successfully creating an incinerator, he filed a patent registration for his ‘hazardous waste incinerator’ to the Ministry of Science and Technology and got the patent in 2012.

Nang’s incinerator is a system which comprises a comprehensive combustion chamber which can burn waste in an uninterrupted process. The incinerator utilizes nano technology which disintegrates hazardous smoke, dust and frog.

The product is believed to have outstanding features which allow it to operate more effectively than products of the same kind.

Nang said that his waste incineration system is movable. The system can work properly if users have a small water tank and can treat the water.

He also said that all the incinerators available in Vietnam don’t have the pressure balance like his. The incinerator can burn waste, eject fire and not oil into burning materials. In the center of the combustion chamber, the temperature can reach 1,800oC.

With Nang’s incinerator, it doesn’t take much time to burn waste. The oil is durable, and there is no technical trouble with oil tubes.

The Ministry of Science and Technology (MST) has certified that Nang’s incinerator is the first medical waste incinerator in Vietnam which can satisfy the Ministry of Natural Resources and the Environment’s standards and it consumes the volume of fuel 80 percent lower than import products.

If the incinerator runs with diesel, it will need VND5,000 only to burn one kilo or waste. Meanwhile, the incinerators from US, Japan and UK would consume VND70,000-80,000 worth of fuel to burn a kilo of waste.

The outstanding feature of the made-in-Vietnam incinerator is that it can treat many kinds of waste, including domestic garbage and medical waste.

Director of the Bac Kan Science and Technology Department Do Tuan Khiem said the incinerator is a suitable choice for localities with moderate waste capacity. The machine is highly efficient and fuel-saving, which is big advantage in Vietnam’s conditions.

From: http://english.vietnamnet.vn/fms/science-it/145663/made-in-vietnam-waste-incinerator-shows-its-power.html

incinerators spacification

Specifications of ovens:

  • Installing a readymade concrete base (Precast) with Height 30 cm above the ground and 20 cm below the surface of the earth.
  • The dimensions of the base are increased by (2 meters) from the edge of incinerators
  • The rest of the accessories in all the trends even allows the worker directly feeding and maintenance work, cleaning and move easily taking into account the tendencies of the base toward the door for drainage of water.
  • The floor coating must be high-quality epoxy paint.
  • Install anti-rust and heat Umbrella of brick and steel (pyramid shape) of (5) meters height above the ground which installed with the edge of the concrete base by thick galvanized columns
  • This umbrella Cover the site furnace and allow bringing the chimney
  • The site is surrounded by an iron fence (sheet metal) 3 meters height from the surface of the earth in order to protect the incinerators from dust storms
  • The iron fence must have a 5 meters Width gate
  • Automatic anti-rust and heat electrical circuit must be provided
  • The furnaces are highly efficient, emissions-free, safe, and environmentally friendly and have capacity of not less than 3,000 kg of materials and the rate of burning at least 400 kg / h
  • The method of feeding the furnace through a side slot or from the top and the emission of the smoke is completely prevented.
  • a furnace Must have two rooms, one of them is the main room of not less than the “5” stoves to the process of burning materials and other secondary room of not less “2” stoves to burn resulting gas from the first process as well as the chimney
  • The main component of the body of the furnace is stainless steel box, the thickness of not less than 7 mm with a layer of zinc phosphate plated with aluminium reflector to heat
  • the thickness of the door of 150 mm and a hardness of not less than 170 kg / m 3 to be burnt, automatic comprehensive remote system.
  • Furnaces must be destructive enough to burn and incinerate the material which mentioned previously
  • furnaces must have certificates are supported global enterprises and government competent for environmental protection In the country of origin or the General Presidency of Meteorology and Environment Protection in Saudi Arabia
  • The oven can work for 24 hours so as to allow for the burning of materials for a period of not less than 12 consecutive hours and the remainder for cooling and provides full fuel tank with a capacity of 1000 L to turn on the oven.
  • Must have an automatic ignition and diesel is used
  • a furnace has the ability to withstand extreme temperatures up to “130o c And also, it guarantees continuous operation of which can be utilized for 24 hours with the ability to remove residues during the work of the oven, Insulating layer of calcium must be present in the rooms with Thickness not less than 50 mm and a wall thickness of 100 mm
  • Isolation of burning room: the space between the walls must be of the “stainless steel”. In addition, burn room must fill with Thermal insulation material.
  • Ensure that the combustion of materials emitted in the secondary room should be at least two seconds period and the room is lined with high-density ceramic fibbers
  • Incinerators must contain a system for processing (purification) gasses before emission of the smoke.
  • Incinerators must have the capacity of self-cooling after the end of the daily operating period.
  • Incinerators must have chimney not less than “4 meters” height from the surface of the oven, also, it must be thermally insulated and non-rust able, and must also be removable, installation and tide default.
  • Electrical capacity required “220/ 380-volt “60 hertz
  • Incinerators must be fitted with a control panel of the electronic keys to monitor all the necessary indicators of activation keys, as well as start-up and switch off so as to be isolated inside a metal box with the presence of the following:

Alarm Sensor in the event of (crashes “burner” or purification device or heat leakage       or internal connections and wiring)

Monitors for the temperature of the rooms

Aerosols Filter indicators/ monitors

Room temperature sensors

Indicators for furnaces and index overload

Timer for Extinguish the oven automatically depending on the time required.

  • All equipment must be highly resistant to external conditions such as high temperature (50oc)
  • All doors must have special lock are not allowed non-persons appointed to work.
  • Providing fire extinguisher for each site with a capacity of 10 kg at least