100 Kgs Per Hr Medical Waste Incinerator

Product Description

Nanjing Clover Medical Technology Co., Ltd..

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

YD incinerator is newest layout for waste treatment, include health care waste, animal cremation and other solid waste. This gear quality structural for kinds of site, like hospital, hospital waste incinerators, hospital waste incinerators china, hous hol waste incinerator technologies, the way to apply for an incinerator licence in south africa, environmental department, animal cremation bureaus, etc.. CLOVER Incinerator supply updated models with double combustion chamber, mix combustion chamber and smoke filter chamber using refractory lines, and the combustion chamber temperature up to 1200 deg C.

Small Mobile Veterinary Incinerator 20 Kg Hour Burn Rate

Basic Info.

Model NO.:waste incinerator china suppliers
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste can utilize within this gear?  A: This gear for medical waste, pet animal, Municipal waste, reside waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001.  The animal/pet combustion speed around 2/3 of average capacity. 

Clover incinerator utilize time per day up to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time plus time for feeding waste. Actual combustion time daily is around 16 hours. The lifetime of incinerator involving 5-10 year according to utilize. 

Ordinarily, we proposal small lab, small clinic use capability under 20 kgs per hour. Mobile incinerator, small monster incinerator, small scale incinerators,, chinese incinerator makers, clover incinerater, hospital waste incinerator, When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people every day. If there are 200 sickbed at the clinic, that’s mean you need one incinerator capability around 400kgs every day, switch to capacity per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, funding, development, etc, you can use capacity from 30-50 kgs per hour incinerator.  *The best way to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Meeting and Testing  A: We supply all documents and incinerators easy to setup and functionality. Client can send people visit our factory to learn installation and operation. Generally, We do not send engineer to local site if not ask. The dispatch cost is additional according to order.  The next combustion chamber: 1000-1200 centi level.  PLC mode according to model and order. 

Q: Operation and maintenance costs  A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual approximately $500-$1000USD annually maintenance according version, utilize situation. 

One person can service 02 device incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in combustion chamber  A: 02 sec.

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items Specification
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Cremation Equipment for Medical Waste

Basic Info.

Model NO.:controlled air dual chamber incinerator capacity
Export Markets:Global

Product Description

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Nanjing Clover Medical Technology Co., Ltd..

20 Kgs Capacity Medical Incinerator

Product Description

Key Features:  * All versions with Dual combustion room.  * Stainless Steel chimney/stack, long lifetime. *according to order  * High temperature, long lifetime of incinerator.  * Free or minimum installation onsite.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton daily.  *according to order  New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock. 

Nanjing Clover Medical Technology Co., Ltd.. Is a leading waste incinerator maker in China. We’re local producer and among the greatest exporter of China. Pyrolytic incinerator gear technical is main waste treatment each one of the world, for Medical Waste, Animal Incineration, residence waste incinerator in china, hospital burner manufacturere, hospital diesel fuel fired incinerators, hospital gear burner 100kg daily, hospital incinerater, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr. Up to 6ton daily. Presently, we provide different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our assortment of incinerators make them among the most cost effective in the world.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator in Hospital

Basic Info.

Model NO.:incinerator for medicial waste
Export Markets:Global

Product Description

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Picture  
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Medical Waste Incinerators

Basic Info.

Model NO.:medical waste incinerator manufacturers
Export Markets:Global

Product Description

Key Features:  * All models with Dual combustion room.  * Stainless Steel chimney/stack, long life. *based on order  * High temperature, long life of incinerator.  * Free or minimal installation onsite.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton daily.  *based on order  New Design for pet animal cremation enterprise.  * One year guarantee on incinerator and parts in stock. 

Program Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Is a top waste incinerator maker in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment each one the world, such as Medical Waste, Animal Incineration, combustion chambers incinerator, company sale equipments of medical waste, concrete combustion chamber, concrete incinerator, containerized incinerator, Pet cremation and other Solid wste. The potential from 10kgs/Hr. To 500kgs/Hr. , up to 6ton daily. Presently, we provide different show for local client requirements and design upgraded incinerator with our top technology. The upgraded design characteristic of our assortment of incinerators make them one of the most cost effective on the planet.

Items Specification
YD Model YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

Hiclover Incinerator

Product Description

Nanjing Clover Medical Technology Co., Ltd..

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
           
           
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

incinerators spacification

  • Installing a readymade concrete base (Precast) with Height 30 cm above the ground and 20 cm below the surface of the earth.
  • The dimensions of the base are increased by (2 meters) from the edge of incinerators
  • The rest of the accessories in all the trends even allows the worker directly feeding and maintenance work, cleaning and move easily taking into account the tendencies of the base toward the door for drainage of water.
  • The floor coating must be high-quality epoxy paint.
  • Install anti-rust and heat Umbrella of brick and steel (pyramid shape) of (5) meters height above the ground which installed with the edge of the concrete base by thick galvanized columns
  • This umbrella Cover the site furnace and allow bringing the chimney
  • The site is surrounded by an iron fence (sheet metal) 3 meters height from the surface of the earth in order to protect the incinerators from dust storms
  • The iron fence must have a 5 meters Width gate
  • Automatic anti-rust and heat electrical circuit must be provided
  • The furnaces are highly efficient, emissions-free, safe, and environmentally friendly and have capacity of not less than 3,000 kg of materials and the rate of burning at least 400 kg / h
  • The method of feeding the furnace through a side slot or from the top and the emission of the smoke is completely prevented.
  • a furnace Must have two rooms, one of them is the main room of not less than the “5” stoves to the process of burning materials and other secondary room of not less “2” stoves to burn resulting gas from the first process as well as the chimney
  • The main component of the body of the furnace is stainless steel box, the thickness of not less than 7 mm with a layer of zinc phosphate plated with aluminium reflector to heat
  • the thickness of the door of 150 mm and a hardness of not less than 170 kg / m 3 to be burnt, automatic comprehensive remote system.
  • Furnaces must be destructive enough to burn and incinerate the material which mentioned previously
  • furnaces must have certificates are supported global enterprises and government competent for environmental protection In the country of origin or the General Presidency of Meteorology and Environment Protection in Saudi Arabia
  • The oven can work for 24 hours so as to allow for the burning of materials for a period of not less than 12 consecutive hours and the remainder for cooling and provides full fuel tank with a capacity of 1000 L to turn on the oven.
  • Must have an automatic ignition and diesel is used
  • a furnace has the ability to withstand extreme temperatures up to “130o c And also, it guarantees continuous operation of which can be utilized for 24 hours with the ability to remove residues during the work of the oven, Insulating layer of calcium must be present in the rooms with Thickness not less than 50 mm and a wall thickness of 100 mm
  • Isolation of burning room: the space between the walls must be of the “stainless steel”. In addition, burn room must fill with Thermal insulation material.
  • Ensure that the combustion of materials emitted in the secondary room should be at least two seconds period and the room is lined with high-density ceramic fibbers
  • Incinerators must contain a system for processing (purification) gasses before emission of the smoke.
  • Incinerators must have the capacity of self-cooling after the end of the daily operating period.
  • Incinerators must have chimney not less than “4 meters” height from the surface of the oven, also, it must be thermally insulated and non-rust able, and must also be removable, installation and tide default.
  • Electrical capacity required “220/ 380-volt “60 hertz
  • Incinerators must be fitted with a control panel of the electronic keys to monitor all the necessary indicators of activation keys, as well as start-up and switch off so as to be isolated inside a metal box with the presence of the following:

Specifications of ovens:

Alarm Sensor at the event of (crashes “burner” or purification device or heat leakage       or Inner connections and Pipes )

Monitors for the temperature of the rooms

Aerosols Filter Signs / monitors

Space temperature sensors

Indicators for furnaces and index overload

  • All equipment must be highly resistant to external conditions such as high temperature (50oc)
  • All doors must have special lock are not allowed non-persons appointed to work.
  • Providing fire extinguisher for each site with a capacity of 10 kg at least

Timer for Extinguish the Toaster automatically depending on the time required.

10 Kg Per Hour Incinerator

Basic Info.

Model NO.:pet incinerators
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste can use within this gear?  A: This gear for medical waste, pet animal, Municipal waste, reside squander. Prohibit any volatile and radiation material, liquid gas and waste waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity  A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion rate around 2/3 of average capacity. 

Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding squander. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Ordinarily, we proposal small laboratory, small clinic use capacity under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output around 2kgs per people every day. If there are 200 sickbed at the clinic, that’s mean you need one incinerator capacity around 400kgs every day, switch to capacity per hour is around 30-40 kgs per hour. According the operation time every day, waste material, funding, development, etc, you can use capacity from 30-50 kgs each hour incinerator.  *The best way to compute Animal Cremation Burn Rate: 2/3 of this medical waste. 

Q: Meeting and Testing  A: We provide all files and incinerators simple to installation and functionality. Client can send people visit our factory to learn operation and installation. China incinerator producer and exporter, crematorium manufacturers, double chamber incinerator, incinerator producer in china, incinerator manufacturers china, Ordinarily, we don’t send engineer to local site or even request. The dispatch cost is additional according to order.  The second combustion chamber: 1000-1200 centi degree.  PLC mode according to order and model. 

Q: Operation and maintenance costs  A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One individual can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and understand risk of medical waste to safeguard worker self with essential protection component. 

Q: The Residency time in secondary combustion chamber  A: 02 sec.

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Gas Fired Incinerators

Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Nanjing Clover Medical Technology Co., Ltd..

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Program Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation