Municipal Waste Incinerator

Municipal Waste Incinerator



Basic Info.

Model NO.:medical waste incinerator manufacturer
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, 50 questions about the philippines, 500 kg animal incinerator size, 500 kg per hour incinerator, 50kg capacity incinerator, 50kg/hr diseal incinerator, 6-8 ton per hour capacity trash burner, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock.

Items/Model MSW2000 MSW3000 MSW4000 MSW5500
Burning Rate  150 kgs/Hr. 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr.
Feed Capacity  400 kgs 600 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 9500 kgs 13000 kgs 16500 kgs
Picture  
Primary Chamber (Liters) 2000 3000 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270x185x380 280x230x425 320x220x460 360x220x475
Internal Dimensions (cm) 180x115x96 240x120x105 257x147x108 300x147x125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Capacidad de destrucción del calentador de 350 kg / hora.

La masacre diaria común involucra a 120 cerdos. El artículo condenado, así como los subproductos del matadero para su eliminación, es de alrededor de 1000 kg diarios.
incinerador de una línea para la destrucción de residuos clínicos nocivos.

– – – – Capacidad de daño del calentador de 350 kg / hora, el valor calorífico de los desechos definitivamente será de 13-25 MJ / kg

[3500 kcal / kg] y también capacidad de acogida ideal 1,225,000 kcal / h.

– – – – La capacidad de daño del quemador definitivamente será de 8.4 toneladas / día y, además, el tiempo de procedimiento definitivamente será de 24 recursos humanos / día.

– – – – Los residuos serán con sistema de alimentación automático directamente al quemador.

-El grado de temperatura definitivamente se regulará en un flujo variable y también en una porción de oxígeno, el gas quemado se vuelve a quemar

en la cámara de combustión [adicional] a un nivel de temperatura mínimo de 1.100 C durante 2 seg.

– – – – El tablero de control estará ciertamente equipado con una vista sinóptica útil que revele las circunstancias operativas de todo el

calentador y también manejado por el sistema DCS / PLC.

– – – – El sistema de terapia de gas apreciará absolutamente la norma EE [Directiva 2000/76 / EC -4 / 12/2000.

– – – – El TOC de la escoria y las cenizas de fondo serán ciertamente mucho menos del 3% del peso seco.

– – – – Sin duda, la instalación estará completamente libre de humo visible.

– – – – El calentador ciertamente se creará como un sistema empaquetado, con un enlace eléctrico precableado y últimas tuberías

en posición.

– – – – El incinerador contará con un sistema de eliminación de cenizas automático con dirección ascendente.

– – – – El quemador ciertamente tendrá un sistema completo de terapia de gases de combustión [pila de derivación para situaciones de emergencia, sistema de enfriamiento de gas,

dos activadores así como también sistema de filtrado de partículas] así como aseguramiento de descargas fuera del quemador.

– – – – Formación de trabajadores de AKU en sitio web.

– – – – El sitio web podría revisarse y también echar un vistazo al fabricante de ATI existente, capacidad 150 kg / h. en 1 día de tratamiento.

– – – – El espacio de las instalaciones existentes está convenientemente disponible en el sótano, 100 ′ ′ Tamaño x 30 ′ grande x 20 ′ Altitud para el segundo incinerador.

– – – – El tamaño actual del conducto de humo es de 12 metros, y también el tamaño es de 24 ″ ″ de diámetro.

Incinerator with 1 or 3 section type wet scrubber

Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy.  Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour capacity.

Model

YD-150

Picture

Burning Rate

Average 150 kgs/hour

Feed Capacity

Average 300 kgs/feeding

Primary Combustion Chamber

1500 Liters

Secondary Combustion Chamber

500 Liters

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Wet Scrubber System(3 Section Type)

Feed Mode

Manual

Voltage

380V

Power

9.0 Kw

Fuel Type

Diesel Oil/ Natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Average 24 kg/hour

Gas Consumption (Natural Gas)

***

Internal Dimensions

150 x 100 x 96cm (primary chamber)

External Dimensions

240 x 170 x 380cm(without chimney/wet scrubber)

Temperature Monitor

Yes

Oil Tank Capacity(if oil fuel)

300 Liters

Door Opening

59 x 81cm

Chimney Length

10.0 Meters

Chimney Type

Stainless Steel

Equipment Gross Weight

11000 kgs

Operation Technical Specifications

Primary Chamber Temperature

800–-1000

Secondary Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Burning Efficiency

98%

Waste Lower Calorific Power

3000Kcal

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27

waste incinerator manufacturers from china

Incinerate: medical waste and general waste Capacity to burn waste:
400-500kg/hr
Fuel: Diesel
Fuel Consumption: 10 liters/hr maximum
Incineration temperature: 950-1300 degrees centigrade
Casing: thick (min 5mm) stainless steel casing and fully insulated to
withstand sea humidity Voltage 220/240v or 380/415V Frequency 50Hz
high-capacity, powerful, European Standard incinerator,ideal for high volume incineration,with integral after-burner for greater efficiency and emissions control.
Waste Type and Burn Rate
Designed specifically for use by poultry farmers,
sheep farm owners,   abbatoirs and for pet
cremation. The incinerator will burn up to 50kg of
waste per hour (up to 150kg burn
Construction
Mild steel welded fabrication consisting of sheet steel
and structural section supports.
Lining
Monolithic high grade refractory concrete with high grade insulation backing.
Burners
Fully automatic, high-efficiency burners with electronic ignition, flame recognition and combustion control devices fitted.
Loading – Ash removal
Manual ash removal from the primary chamber. (Ash doors are available on request).
Exterior finish
Multi-coat high quality, high-temperature aluminium enamel top coat paint, finished in silver.
Control
Fully automatic sequential control provided by internal
waste incinerator manufacturers from china, PLC system providing control of:
1. Secondary chamber pre-heat
2. Burn cycle (variable)
3. Cool down cycle
Fuel Options
Diesel, LPG, Natural or Bio Gas.
Typical Fuel Consumption
Diesel: 8 / 10 litres per hour
Liquid Propane Gas: 6 / 8 litres per hour
Natural Gas: 7 / 9 Nm3 per hour
Electrical supply
240volt 16 amp.
Key Specifications
Chamber Volume 2.38m3:
2.2m (l) x 0.9m(w) x 1.2m(h)
Load Capacity up to 1000kg
Load Method Top.·         Type: Pyrolytic

·         Use: For drugs

·         With Chassis to be Mounted in truck/lorry

·         May have a primary and secondary combustion chamber

·         Must have a dilution chamber

·         Capacity: 100 Kgs per hour

·         Power Source: Diesel or Natural Gas or Liquified Natural Gas

pequeño incinerador de matriz de capacidad de derramamiento

Quemador de pollos – – – – 400 kg de alimento por día Un incinerador a pequeña escala con capacidad de desprendimiento 30 kg / h = 1 No. Tenga en cuenta que debe ser móvil, ya que está destinado a campamentos de tiendas de campaña de servicio en áreas petroleras. Tiene que funcionar con diesel ya que nuestra ubicación es remota. 150! kg por recurso humano Quemador eléctrico de GLP a utilizar en el aeropuerto internacional. Este es un requisito para la seguridad de la biografía y también la seguridad de que todos los vuelos globales necesitan que toda la basura se sofoque dentro de un tiempo reconocido.
Cámara – – – – Primar 900 litros Adicional: 300Litros
Eje de humo 8M
Costo de combustión: 50 kg / h Sí.
Capacidad de alimentación: 150 kg Sí.
Cámara de quemado de llaves: 900 litros Sí.
Segunda cámara de combustión: 300 litros Sí.
Cámara de combustión mixta: Sí Sí.
Cámara de filtro de humo: Sí Sí.
Configuración de alimentación: Manual Sí.
Potencia: 0,7 Kw Sí.
Tipo de gas: Gasóleo / Gas natural / GLP Sí. Varios Precio si es combustible de petróleo o gas.
Dimensiones internas: 120 x 90 x 85 cm (cámara de truco) Sí.
Dimensiones exteriores: 200 x 160 x 310 cm (sin conducto de humos) Sí.
Rendimiento de combustión: >> 98% Sí

Clover Medical Limited a Leading Waste Incinerator



Basic Info.

Model NO.:construction of an incinerator
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our rang 

Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. 

Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 

Incinerator fuel: Gas incinerator, oil incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 

Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

DIESEL FIRED INCINERATOR, WITH 1000 LTR FUEL TANK AND 6M CHIMNEY

Items/Model

TS250(PLC)

Picture

Principle

Waste Incineration Treatment

Burn Rate

Average 250 kg/hour

Feed Capacity

Average 400kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

2000L

Internal Dimensions

210x88x110cm

Secondary Chamber

1000L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

2.0Kw

Oil Consumption (kg/hour)

Average 24.2(DO)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

1000L

Feed Door

2.04 x 1.06 M

Chimney

3Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

800–-1000

2nd. Chamber Temperature

1000-1200

Residency Time

2.0 Sec.

Gross Weight

9000kg

External Dimensions

3.00mx1.60mx3.00m (without chimney)

INCINERATION IS A WASTE TREATMENT PROCESS THAT INVOLVES THE COMBUSTION OF ORGANIC SUBSTANCES CONTAINED IN WASTE MATERIALS. INCINERATION AND OTHER HIGH-TEMPERATURE WASTE TREATMENT SYSTEMS ARE DESCRIBED AS “THERMAL TREATMENT”. INCINERATION OF WASTE MATERIALS CONVERTS THE WASTE INTO ASH, FLUE GAS AND HEAT. THE ASH IS MOSTLY FORMED BY THE INORGANIC CONSTITUENTS OF THE WASTE AND MAY TAKE THE FORM OF SOLID LUMPS OR POWDER.

TWO (2) YEAR MAINTENANCE SPARES PACKAGE FOR LINE ITEM 2 X OIL FIRED BURNER

2 X CEMENT REPAIR KIT (25KG)

2 X THERMOCOUPLE

2 X FIRE ROPE (1M)

2 X HT MASTIC (PER INCINERATOR)

1 X PPE KIT


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27

quemador eco placentero

Centro de atención médica de 50 camas y, además, le gustaría tener su recomendación para un quemador que pueda manejar de manera efectiva las toneladas de hospital de 50 camas. Incinerador para basura quemable (papel & & & & natural) capacidad de dispositivo (100/150 lts). Incineradores de desechos biomédicos,

Capacidad: 50 kg por hora Diseño de quemador de desechos médicos TS50 (PLC) con ambas opciones de combustible (gas y adicionalmente / o quemadores Diesel2
Termopar de 2 grados de temperatura
5 metros para junta térmica
1 instancia de control de calentador
1 soplador incinerador ecológico para el desprendimiento de bolsas de polipropileno tenemos 10 lotes semanales

General specifications of a 100 kg/hr three combustion Chambers Incinerator

General specifications of a 100 kg/hr incinerator
No. Description Parameter value  
  model   HICLOVER YD100
1 Machine working mode Oil + Power Oil + Power
2 Voltage 220V C 3 phase or 1 phase 220V 1P
3 Oil consumption (lit/hr) Average 25-32 lit/hr/chamber Average 33Liters/hour/total incinerator 3 burners
6 Incineration rate 100 kg/hr = 400-600 kg/8hr average 100kgs per hour
7 Feed mode Manual manual
8 Primary combustion rate 1000 lit 1080 liters
9 Secondary combustion rate 240 lit 207 Liters
10 Tertiary combustion rate 416 lit 452 liters
11 Combustion chamber material High temp. resistant concrete High temp. resistant concrete
12 Internal dimensions (1st chamber) 100*100*100 cm (l*w*h) = 1000 lit 120*100*90cm(l*w*h) = 1080 lit
13 Internal dimensions (2nd  chamber) 40*40*150 cm = 240 lit Diameter 42*150cm=207 Liters
14 Internal dimensions (3rd  chamber) 40*40*260 cm = 416 lit Diameter 60*160cm=452 Liters
15 External dimensions 300*155*200 cm (l*w*h) 220*160*370 cm (l*w*h)
16 Door opening 90*90 cm 90*90 cm
17 Additional air fan 1 fan (on the door) 1 fan (on the door)
18 Fuel type Diesel oil/ Diesel oil
19 Burner Brand: Radiator or Hofmat Italy Baltur
20 Chimney length 3-4 meters 5 Meters
21 Chimney type and material H-type stainless steel, or High temp. resistant concrete 1 Meter High temp. resistant concrete +4 Meter Stainless steel
22 Smoke and smell filter Yes, two stages. Dry Scrubber 2 stages
23 Temperature monitor Yes, (for 1st and 3rd chambers) Yes, (all 3 chambers)
24 Temperature control Optional yes
25 Oil tank 500 lit needed. yes
26 Burning efficiency >98% yes
27 1st chamber temperature 300-700 oC 800-1000 oC
28 2nd chamber temperature 500-1000 oC 1000-1200 oC
29 3rd chamber temperature 800-1200 oC 1000-1300 oC
30 Smoke residency time >2 sec. >2 sec.
31 Gross weight 5-8 tons average 6.5 Ton
32 No. of Burners 3 3

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27

Incinerator (YD-10C)



Product Description

We are one of the largest waste incinerator manufacturer and exporter of China. Pyrolytic incinerator technical is main waste treatment method all over the world, for Medical Waste, double chambered incinerator, double chambered incinerators, double champer incineration pdf, double-chamber pyrolytic incinerators, Animal Incineration, Pet cremation and other Solid waste. Presently, we supply small and large scale incinerators as local customer requirements and design updated incinerator with our leading technology. 

Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Equipment Technical Specifications
Model YD-10C
Feed Capacity 40-80 kgs per feed
Burning Rate 10 kgs per hour
Burning Time per Feed 3.0 -5.0hours
Voltage 220V
Power 0.50Kw
Fuel Natural Gas or Diesel oil
Burner Italy Burner
Feed Mode Manual
Fuel consumption (Oil) 4.4-9.4 Kgs/Hour
Fuel consumption (Gas) 5.3-11.2m3/Hour
External Dimensions 170 x 140 x 160cm (mainbody)
Internal Dimensions 55 x 55 x 65cm(Primary Chamber)
Waste combustion chamber 200Liters
Post Combustion Chamber 140Liters
Oil Tank Capacity 50 Liters
Door Opening 38 x 48cm
Chimney 5.0M
Gross Weight 1200kgs
Chamber Material Refractory Concrete
Max. Heat Value 94,000Kcal/Hr.
Operation Technical Specifications
Solid Chamber temperature 800 0 C -1000 0 C
Gas Chamber temperature 1000 0 C -1200 0 C
Chamber Anti-Rate 1350 0 C
Residency time 2.0 Sec.
Burning efficiency >98%
Waste Lower Calorific Power 3000Kcal