Pet Animal After Cremation
Pet Animal After Cremation
Pet Animal After Cremation
Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply veterinary hospital on site cremation, vietnam incinetaor, volume of combusted waste is reduced by approximately 90%, increasing the life of landfills, w2e incinerators, different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Nanjing Clover Medical Technology Co., Ltd., local in Nanjing city, China. CLOVER is manufacturer of medical product, waste incinerator and other environmental protection equipment. The market network across over the territory of China and more than 30 countries throughout the world.
CLOVER supply medical equipment, medical waste incinerators, china health care waste incinerator manufacturer, china hog farms incinerator, china hospital incinerator, china household incinerator, china incenirator medical waste, pet animal cremator, other solid waste treatment equipment, clean room equipment, fan filter units, air filter, etc. We supply technology service, installation service and customer made.
We are one of the largest waste incinerator manufacturer and exporter of China. Pyrolytic incinerator technical is main waste treatment method all over the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid waste. Presently, we supply small and large scale incinerators as local customer requirements and design updated incinerator with our leading technology.
Nanjing Clover Medical Technology Co., Ltd.
Tel: +86-25-8461 0201
Fax: +86-25-8461 0406
Add: RM. 7411, No. 58 Yunjin Rd., Nanjing, China 210019

平面口罩机参数:
Semi-Automatic Mask Machine
l Power supply: 3.3KW mono phase
l Mask Size: 175mm*80-100mm (two or three layers)
l Nonwoven (GMS): 10-50g
l Capacity: 120 to 150pcs/min
l Dimension(L*W*H):3800mm*500mm*1400mm
l Net Weight: about 1000kg

焊接机参数:
Welding Machine
l Capacity: 5 to 10pcs/min
l Power supply: 8.5KW mono phase
l Compressed Air connection: 0.5 to 0.7Mpa
l Dimension(L*W*H): 900mm*650mm*1380mm
l Net weight: approx. 50kg

KN95口罩机参数:
N95 Mask Machine
l Capacity: 130 to 160pcs/min
l Dimension(L*W*H): 1037*855*1780
l Power Supply 15.3kw mono phase
l Net Weight: approx.: 1500kg

2020-04-06
TABLE OF CONTENTS
The objective of the programme is to select technical criteria suitable for tender specification purposes that will enable the South African Department of Health to obtain the services and equipment necessary for the primary health care clinics to carry out small-scale incineration for the disposal of medical waste.
The test programme is being carried out in phases, as follows:
Phase 1 A scoping study to decide the responsibility of the different parties and
consensus on the test criteria and boundaries of the laboratory tests. The criteria for accepting an incinerator on trial was approved by all parties involved.
Phase 2 Laboratory tests with a ranking of each incinerator and the selection of the incinerators to be used in the field trials.
Phase 3 Completion of field trials, to assess the effectiveness of each incinerator under field conditions.
Phase 4 Preparation of a tender specification and recommendations to the DoH for the implementation of an ongoing incineration programme.
This document provides feedback on phases 2 and 3 of the work.
SA Collaborative Centre for Cold Chain Management SA National Department of Health
CSIR
Pharmaceutical Society of SA World Health Organisation UNICEF
The following stakeholders participated in the steering committee:
International visitors:
y Occupational safety
y Impact on public health from emissions
y The destruction efficiency
y The usability for the available staff
y Professional nurse; Mrs Dorette Kotze from the SA National Department of Health
y Emission specialist; Dr Dave Rogers from the CSIR
y Combustion Engineer; Mr Brian North from the CSIR
| Name used in report | Model no. | Description | Manufacturer |
| C&S Marketing
incinerator |
SafeWaste Model Turbo
2000Vi |
Electrically operated fan supplies combustion air
– no auxiliary fuel |
C&S Marketing cc. |
| Molope Gas incinerator | Medcin 400 Medical
Waste Incinerator |
Gas-fired incinerator | Molope Integrated
Waste Management |
| Molope Auto incinerator | Molope Auto Medical
Waste Incinerator |
Auto-combust incinerator – uses wood
or coal as additional fuel to facilitate incineration |
Molope Integrated
Waste Management |
| Name used in report | Model no. | Description | Manufacturer |
| PaHuOy
incinerator |
Turbo Stove | Auto-combust unit,
using no additional fuel or forced air supply |
Pa-Hu Oy |
Sampling of emissions followed the US-EPA Method 5G dilution tunnel method for stove emissions. Adjustments to the design were made to account for flames extending up to 0.5 m above the tip of the incinerator and the drop out of large pieces of ash. Emissions were extracted into a duct for isokinetic sampling of particulate emissions. The sampling arrangement is shown by a schematic in Figure 1. A photograph of the operation over the Molope gas fired incinerator unit is shown in Figure 2.
All tests were performed according to specified operating procedures. The instructions provided by the supplier of the equipment were followed in the case of the C&S Marketing Unit. No operating procedures were supplied with the Molope Gas, Molope auto-combustion and PaHuOy units. These procedures were established by the CSIR personnel using their previous experience together with information provided by the supplier.
Test facilities were set up at the CSIR and measurements were carried out under an ISO9001 system using standard EPA test procedures or modifications made at the CSIR.
Using the criteria listed under section 4.1 above, the incinerators were ranked as followed:
| Molope gas-fired
unit |
Molope wood-fired
unit |
C&S electric
unit |
PaHuOy wood-fired
unit |
|
| Safety | 6.8 | 4.8 | 5.5 | 3.3 |
| Health | 5.5 | 3.5 | 4.3 | 2.3 |
| Destruction | 9 | 2 | 6 | 1 |
| Usability | 2 | 3 | 3 | 5 |
| Average | 5.8 | 3.3 | 4.7 | 2.9 |
Quantitative measurements were used to rank the units in terms of destruction efficiency and the potential to produce hazardous emissions.
Conformance to the South African Department of Environmental Affairs and Tourism’s (DEAT) recommended guidelines on emissions from Large Scale Medical Waste Incinerators is summarized in Table 1. The measurements are listed1 in Table 2.
| Parameter Measured | Units | Molope
Gas-fired |
Molope
Wood-fired |
C&S
Electric |
PaHuOy
Wood-fired |
SA DEAT
Guidelines |
| Stack height | m | × | × | × | × | 3 m above
nearest building |
| Gas velocity | m/s | × | × | × | × | 10 |
| Residence time | s | × | × | × | × | 2 |
| Minimum combustion
temperature |
ºC | 4 | × | × | × | > 850 |
| Gas combustion
efficiency |
% | × | × | × | × | 99.99 |
| Particulate emissions | mg/Nm3 | 4 | × | 4 | × | 180 |
| Cl as HCl | mg/Nm3 | × | 4 | 4 | × | < 30 |
| F as HF | mg/Nm3 | 4 | 4 | 4 | 4 | < 30 |
| Metals | mg/Nm3 | 4 | × | × | 4 | < 0.5 and
< 0.05 |
1 Emission concentrations are reported in accordance with the South African reporting requirements, ie, normalized to Normal Temperature (0
oC) and Pressure (101.3 kPa) and corrected to a nominal concentration of
8 % of CO2 on a dry gas basis. If a measurement fell below the detection limit for the method is it either reported as the detection limit or as N.D., ie, not detectable.
|
Parameter Measured * |
Units |
Molope gas |
Molope auto |
C&S |
PaHuOy |
SA Process Guide1 |
Comments |
|
Stack height |
m |
1.8 |
1.8 |
1.9 |
0.3 |
3 m above nearest building |
None of these unite has a stack. The height of the exhaust vent is taken as the stack height. If it is above the respiration zone of the operator it provides some protection from exposure to smoke. |
|
Gas velocity |
m/s |
0.8 |
0.5 |
1.1 |
0.5 |
10 |
Gas velocities vary across the stack for the Molope gas, Molope auto-combustion, and the PaHuOy units. |
|
Residence time |
s |
0.4 |
0.7 |
0.6 |
0.4 |
2 |
Residence time is taken to be the total combustion time, and the maximum achievable |
|
Minimum combustion zone temperature |
oC |
800 -900 |
400 – 650 |
600 – 800 |
500 – 700 |
> 850 |
Molope auto-combustion temperatures are expected to be higher as the centre of the combustion zone is not expected to be at the measurement location. |
|
CO2 at the stack tip |
% vol |
2.64 |
3.75 |
4.9 |
3.25 |
8.0 |
Actual emission concentrations are less than the values reported here, which are normalized to 8 % CO2 and Normal temperature and pressure for reporting purposes. They are lower between 4 to 8 times. |
|
Gas |
% |
99.91- |
98.8 -98.4 |
99.69- |
98.9 |
99.99 |
Most accurate measurement in |
| Combustion | 99.70 | 99.03 | the duct where mixing of exhaust | ||||
| efficiency | gases is complete. Results of two
trials. |
||||||
|
Particulate emissions entrained in exhaust gas |
mg/Nm3 |
102 |
197 |
130 |
338 |
180 |
The total emissions are the sum of the both entrained and un- entrained particulates. Emissions are lower than expected for such units and this is attributed to the absence of raking which is the major source of particulate emissions from incinerators without an emission control system. |
|
Particulate fall- out |
mg/Nm3 |
42 |
105 |
n.d. |
n.d. |
– |
Large pieces of paper and cardboard ash rained out of the emissions. Totalling 0.8 to 2 g over a +/- 2 minute period. |
|
Soot in particulates |
% |
42.2 |
58.1 |
48.7 |
84.8 |
– |
Correlates directly with gas combustion efficiency |
1 Emission concentrations are reported in accordance with the South African reporting requirements, ie, Normalized to Normal Temperature (0
oC) and Pressure (101.3 kPa) and corrected to a nominal concentration of
8 % of CO2 on a dry gas basis. If a measurement fell below the detection limit for the method is it either reported as the detection limit or as N.D., ie, not detectable.
|
Parameter Measured * |
Units |
Molope gas |
Molope auto |
C&S |
PaHuOy |
SA Process Guide1 |
Comments |
|
% ash residual from medical waste |
% |
14.8 |
12.9 |
15.6 |
21.7 |
– |
Measurement of destruction efficiency of the incinerator. Typical commercial units operate at 85-90 % mass reduction. PaHuOy is lower due to the melting and unburnt plastic. |
|
Cl as HCl |
mg/Nm3 |
46 |
13 |
25 |
35 & 542 |
< 30 |
PaHuOy chloride concentrations varied considerably. This is expected due to the variability of the feed composition. |
|
F as HF |
mg/Nm3 |
< 6 |
< 1 |
<2 |
< 1 |
< 30 |
Fluoride not found in this waste. |
|
Arsenic (As) |
mg/Nm3 |
< 0.2 |
< 0.2 |
< 0.2 |
< 0.2 |
0.5 |
Arsenic is not expected as a solid. |
|
Lead (Pb) |
mg/Nm3 |
< 0.4 |
< 0.4 |
< 0.4 |
< 0.4 |
0.5 |
Lead not expected in waste |
|
Cadmium (Cd) |
mg/Nm3 |
< 0.2 |
< 0.2 |
< 0.2 |
< 0.2 |
0.05 |
Sensitivity of the x-ray method is adequate for ranking. Higher sensitivity not sought for this trial. |
|
Chromium (Cr) |
mg/Nm3 |
< 0.1 |
0.7 |
0.7 |
< 0.1. |
0.5 |
Chromium relative to iron ranges between 12 and 25% which is consistent with stainless steel needles |
|
Manganese (Mn) |
mg/Nm3 |
< 0.1 |
0.3 |
0.3 |
< 0.1 |
0.5 |
Manganese may be a component in the stainless steel needle. |
|
Nickel (Ni) |
mg/Nm3 |
< 0.1 |
0.3 |
< 0.1 |
< 0.1 |
0.5 |
Nickel may be a component in the needle. |
|
Antimony (Sb) |
mg/Nm3 |
< 0.2 |
< 0.2 |
< 0.2 |
< 0.2 |
0.5 |
Not expected in this waste. |
|
Barium (Ba) |
mg/Nm3 |
< 0.5 |
< 0.5 |
< 0.5 |
< 0.5 |
0.5 |
Lower sensitivity due to presence in the filter material |
|
Silver (Ag) |
mg/Nm3 |
< 0.2 |
< 0.2 |
< 0.2 |
< 0.2 |
0.5 |
Not expected in this waste. |
|
Cobalt (Co) |
mg/Nm3 |
< 0.1 |
< 0.1 |
< 0.1 |
< 0.1 |
0.5 |
Cobalt might be present in stainless steel. |
|
Copper (Cu) |
mg/Nm3 |
< 0.5 |
< 0.5 |
< 0.5 |
< 0.5 |
0.5 |
Lower sensitivity due to copper in the sample blanks. May be background in the analytical equipment. |
|
Tin (Sn) |
mg/Nm3 |
< 0.2 |
< 0.2 |
< 0.2 |
< 0.2 |
0.5 |
Tin not expected in this waste. |
|
Vanadium (V) |
mg/Nm3 |
< 0.1 |
< 0.1 |
0.4 |
< 0.1 |
0.5 |
Vanadium might be present in stainless steel. |
|
Thallium (Tl) |
mg/Nm3 |
< 0.4 |
< 0.4 |
< 0.4 |
< 0.4 |
0.05 |
Not expected in this waste. Sensitivity of the x-ray method is adequate for ranking. Higher sensitivity not sought for this trial. |
The main conclusions drawn from the trials are as follows:
::: All four units can be used to render medical waste non-infectious, and to destroy syringes or render needles unsuitable for reuse.
::: The largest potential health hazard arises from the emissions of smoke and soot. (the combustion efficiency of all units lies outside the
regulatory standards). The risk to health can be reduced by training operators to avoid the smoke or by installation of a chimney at the site.
::: The emissions from small scale incinerators are expected to be lower than those from a wood fire, but higher than a conventional fire-brick-
lined multi-chambered incinerator.
::: Incomplete combustion, and the substantial formation of smoke at low height rendered the PaHuOy unit unacceptable for field trials. Figure 3
below shows this unit during a trial burn. Molten plastic flowed out of
the incinerator, blocked the primary combustion air feed vents, and burnt outside of the unit.
The CSIR performed a quantitative trial in the field for gas combustion efficiency, temperature profiles and mass destruction rate on the Molope Auto wood-fired unit at the Mogale Clinic.
The results of this trial are compared to the laboratory trial results below:
Temperatures were higher but for a shorter time and this was
correlated with the type of wood available to the clinic. The fuel was burnt out before the medical waste was destroyed completely and this resulted in lower temperatures, lower combustion efficiency and higher emissions while burning the waste.
prior to full ignition of the waste.
It was concluded that:
The following recommendations are made as the result of the laboratory trials:
::: A comprehensive operating manual must be supplied with each unit.
Adequate training in the operation of the units must be provided, especially focussed on safety issues.
::: It is recommended that the height of the exhaust vent on all units be
addressed. In order to facilitate the dispersion of emissions and reduce the exposure risk of the operators.
::: The suppliers of the incinerators must provide instructions for the safe handling and disposal of ash.
After completion of the laboratory trials, the project steering committee recommended that the Molope Gas and C&S Marketing units be submitted for field testing. The Molope Auto was recommended for field testing on the condition that the manufacturer modified the ash grate so as to prevent the spillage of partially burnt needles and syringes.
The objective of the field trials was to obtain information in the field and assess the strengths and weaknesses of each of the incinerators during use at primary health care clinics.
A participative decision making process was used for the trials. It was based on expert technical evaluation by the CSIR and the National Department of Health as well as participation in the trials by experienced end users and participating advisors. All decisions were made by the Steering Committee, which consisted of representatives of stakeholders in the clinical and medical waste disposal process. These included representatives from the National, Provincial, and Local Government departments of Health, Safety and the Environment, as well as Professional Associations, Unions, NGOs, UNICEF, the WHO and local community representatives.
The Provinces in which the trials were done selected clinics for the field trials. The criteria set by the Steering Committee for the selection of the clinics were the following:
y No medical waste removal
y No existing incineration
y No transport
The clinics that were selected were as follows:
incinerator, wood-fired.
incinerator
MAP OF SOUTH AFRICA INDICATING WHERE THE CLINICS ARE SITUATED
NORTHERN PROVINCE
GAUTENG PROVINCE
NORTH WEST PROVINCE
MPUMALANGA PROVINCE
FREE STATE PROVINCE
NORTHERN CAPE PROVINCE
KWAZULU-NATAL PROVINCE
|
EASTERN CAPE PROVINCE
WESTERN CAPE PROVINCE
The criteria for the ranking of the incinerators in accordance with performance in the field were:
The South African National Department of Health coordinated the field trials.
Information regarding the field trials as well as questionnaires were supplied to the coordinators in the participating provinces.
The team in the field consisted of the operator, supervisor and inspector (coordinator). The manufacturer of the incinerators did the training of the operators.
The questionnaires used during the trials were set so as to obtain information with regard to the criteria set for the ranking of the incinerators in accordance with performance in the field. The questionnaires were received from the clinics at two-weekly intervals.
Questions with regard to the criteria were the following:
y Volume and thickness
y Colour
y Odour
y Complete
y Partial
y Minimal
y Residue content
y Operator
y Nurse
y Head of the clinic
y Local Authority representative
y Community leader
During the trials the clinics were visited and the incinerators evaluated by members of the Steering Committee and the CSIR as well as Dr L Diaz from WHO, Mr M Lainejoki from UNICEF and the coordinator from the National Department of Health.
Type of incinerator at the clinic: Molope Auto-Combustion (Fired with wood)
Difficulty in controlling the operating temperature and avoiding smoke emissions made this incinerator user unfriendly.
As a result of the heavy, black smoke emission the unit was not acceptable to the community.
Type Of Incinerator: C&S Auto-Combustion (Uses an electrically actuated fan)
Considered user friendly by operator, supervisor and inspector.
The incinerator was accepted by the community and was not considered to be harmful.
Type of incinerator: Molope Gas incinerator
This incinerator was considered user friendly.
The incinerator was accepted by the community and was not considered to be harmful.
| INCINERATOR | RANKING |
| Molope Gas | 1 |
| C&S Auto-Combustion (Uses electrical fan) |
2 |
| Molope Auto- Combustion (Fired with
wood, coal also an option) |
3 |
| Incinerator | Safety | Destruction Capability | Usability | Community Acceptability |
| Molope Gas | Good | Good | Good | Good |
| C&S Auto- Combustion
(Uses Electricity) |
Good |
Good |
Good |
Good |
| Molope Auto-
Combust Incinerator |
Un-Acceptable | Good | Un-Acceptable | Un-Acceptable |
2011 year is an important foundation for us. We reach to developed country market and stabilize our old customers. Our incinerator use in Southeast Asia, incineration burner, incineration chamber, incineration chien de 50 kilos, incineration disposal of solid waste, incineration equipment manufacturer, Central Asia, Europe, Middle East, Africa and Australia, etc. Clover Incinerator has grown to be one of the famous and biggest incinerator supplier all over the world.
Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime. *according to order
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.
* PLC Control Plane. *according to order
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.
| Item | Customer Request | Example |
| Application Scope | |
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc |
| What kind of waste? | ____, _____% ____, _____% ____, _____% |
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent if for animal/pet, indicate animal size like: cat, dog, cattle, etc |
| Quantity Request | 01.02.03^…unit |
|
| Budget | $US Dollar. |
|
| Operating Time | The staff work Hours per day. Our incinerator can work up to around 18 hours per day. |
|
| Realization Date of project | In ___ year | |
| Waste Output Capacity per Day? | |
1000kgs Per Day^ |
| Request waste burn rate | Capacity: 100kgs Per hour^ | |
| Request waste feed capacity | Capacity: 100kgs per feed^ | |
| Whether Natural Gas Supply Local? | Yes or No. | |
| Local Power | If 380V and 220V valid? | |
| Product Installation Destination | |
Country or City name |
| DestinationSeaport name? | To check sea freight charge. |
|
| Customer | End-Customer, Agent, Government. |
|
| Method of contract | Tender or Negotiation | |
| Date of Tender limit | ||
| How did you know our company? | ||
| Other request or information | |
TS model PLC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, animal pet incinerator for sales,animal shelter incinerator for sale,animal waste cremator,animal waste furnace,animal waste incinerator for 50 kg,animal waste incinerator with heat exchanger,like hospital, environmental department, animal cremation agencies, etc. CLOVER Incinerator supply updated models with dual combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg |
| Control Mode | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm |
| Secondary Chamber | 50L | 110L | 180L | 280L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 |
| Temperature Monitor | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| 1st. Chamber Temperature | 800–1000 degree | 800–1000 degree | 800–1000 degree | 800–1000 degree |
| 2nd. Chamber Temperature | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm |
Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime. *according to order
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.
* PLC Control Plane. *according to order
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.
Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below:
Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant.
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators
Incinerator fuel: Gas incinerator, oil incinerator
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator
Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India)
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| 1st. Chamber Temperature | 800–1000 degree | 800–1000 degree | 800–1000 degree | 800–1000 degree | 800–1000 degree |
| 2nd. Chamber Temperature | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both incinerators in hospitals, incinerators in unkraine, incinerators italy, incinerators lab scale, incinerators manufacturer china, incinerators manufacturers, man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc.
A Model animal crematory burning rate from 20-400kgs per hour. Heavy duty combustion chamber and suit for large animal cremation.
Secondary Chamber & Mix-Combustion Chamber. Residency time 2.0 sec. In post combustion chamber. Virtually smoke and smell free.
Smoke Filter Chamber with filter brick, Virtually smoke and smell free after burning.
Italy original oil or gas burner, quality reliable. It suit for diesel oil, natural gas, LPG gas.
User guider, full installation and operation document for customer.
| Items/Model | A1500 | A2400 | A4000 | A5500 |
| Burning Rate *animal | 90 kgs/Hr. | 150 kgs/Hr. | 200 kgs/Hr. | 400 kgs/Hr. |
| Feed Capacity *animal | 120 kgs | 200 kgs | 300 kgs | 500 kgs |
| Equipment Weight | 7000 kgs | 8300 kgs | 13000 kgs | 16500 kgs |
| Picture | ||||
| Primary Chamber (Liters) | 1500 | 2400 | 4000 | 5500 |
| Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 |
| External Dimensions (cm) | 240x170x380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 |
| Internal Dimensions (cm) | 150x100x96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 |
| Oil Tank(Liters) | 500 | 500 | 500 | 500 |
| Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 |
| Chimney (M) | 10 | 10 | 14 | 14 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |
Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime. *according to order
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.
* PLC Control Plane. *according to order
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.
Application Scope:
1. Hospital& clinic: China incinerator cost, china incinerator factory, china incinerator manufacturer dual chamber, china incinerator manufacturer large, china incinerators
Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.
3. Community & Sea Port & Station: Municipal Solid Waste, etc.
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation