hiclover

Medical Facility Waste Monitoring

Hospital Waste Management as well as Competitive prices as Pakistan is a competitive market. We have a complete setup with Office, Customer Relations, Import / Export, Biomedical Department, Application Support Department & Project Designing Department.Description        Minimum Requirements
Design standard    Multiple chamber incinerator to the design of EPA  standards, Air pollution control
Description of the Chimney    Top mounted, self supporting
Incinerator performance    150kg/hr
Refuse     Hospital waste and carcasses
Recommended Temperatures    Minimum 1000⁰C
Dimensions:
Length
Width
Height
Extra width for burners    At least 3000mm
Loading door opening    Minimum 700mm x 600mm
Hearth area    5.00square meters
Description or grate/hearth    A full hearth supplied to prevent contaminated liquids from flowing into the ash pit without being incinerated
Primary chamber volume    At least 3 cubic meters
Mixing chamber volume    At least 1 cubic meters
Settling chamber volume    At least 3 cubic meters
Weight excluding chimney    15, 000kg at manufacture
Firing tools supplied    Hoe, Poker and rakeMaterial of construction    Case – 5mm mild steel.
Bracing – Heavy angle and channel.
Hearth – 1550⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
Ashing door – High grade cast iron.
Loading door – 5mm mild steel lined with 1550⁰C castable  general purpose high strength, high abrasion resistant monolithic refractory concrete.
Refractory  concrete:
Alumina content of refractory
Refractory thickness
Minimum 49%
At least 127mm.
Insulation  to walls     1000⁰C Castable insulation
Chimney stack:
Chimney
Height from base    3.5 mm mild steel
9 meters above ground level and clear the highest point of the building by not less than 3 meters
At least 560mm
At least 750Kg
Controls:
Draught

Air supply

Electric

Barometric indicator, door operated draught limiter

Built-in forced heated air ducts, primary and secondary (intensifier)
Control panel – Circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer.
Electricity supply required    415 Volts Three phase.
Auxiliary  fuel    Electrically operated only
Emission     Multiple chamber design with inbuilt emission control
Paint: Case and stack    400⁰C Heat Resistant Grey
Temperature of case    100⁰C

утилизировать Медицинские отходы IV

инсинератор может использоваться для утилизации медицинских отходов внутривенно, использованных игл, использованных шприцев, скальпелей, использованных перевязочных материалов, средств индивидуальной защиты, таких как халат, перчатки и т. д., ампутированных частей тела, испражнений пациентов и других лабораторных отходов. смесь медицинских и опасных отходов. Медицинские отходы включают (но не ограничиваются ими) материалы, загрязненные кровью, биологическими жидкостями, фекалиями и человеческими тканями / органами после хирургических операций. Опасные соединения включают (но не ограничиваются ими): ксилол, толуол, хлороформ, метиленхлорид, трихлорэтилен, ацетонитрил, отходы формальдегида, отходы химиотерапии (например, хлорамбуцил, цитоксин, дауномицин и т. Д.), Отходы радиологии (например, глутаральдегид), и ртутьсодержащие соединения. включает ампутированные части тела, биологические жидкости, включая зараженную кровь, продукты крови, экскременты пациентов, культуры инфекционных вирусов и другие лабораторные отходы и т. д.
Медицинские услуги также могут включать использованные иглы, использованные шприцы, использованные, просроченные или загрязненные перевязочные материалы, такие как бинты, пластыри, пластмассы и т. Д. Установки для сжигания должны также обеспечивать удаление других отходов, образующихся в больничной среде. Технические характеристики переносных установок для сжигания отходов.

Объем камеры около 0,37 м3 и
1 объем горючего груза (объем материала)
примерно 0,30 м3

2 Мощность горелки около 189 000 ккал / час.
Максимальная температура сгорания до 1250

Градус Цельсия
Тип выбрасываемого газа: инертный и нулевой эффект загрязнения окружающей среды
Электрическая мощность: 220 В / 50 или 60 Гц

Топливо: Дизель

Приблизительное потребление электроэнергии: 0,35 кВт / ч.

Диапазон расхода топлива: 7-11 л / час

Органы управления: управление инсинератором, включая панель управления, таймер, дисплей для контроля температуры сгорания, отображение системных ошибок и т. Д.
Упаковка / Установка: Инсинератор полностью собран и готов к подключению к источнику питания.

Руководство по эксплуатации: пакет должен сопровождаться инструкцией по эксплуатации, включая подробную информацию по установке, эксплуатации, техническому обслуживанию, интерпретации сигналов устранения неисправностей и контактных телефонов.
номера / адреса электронной почты технических специалистов местного или зарубежного производителя, с которыми можно связаться для получения рекомендаций по эксплуатации оборудования, если это необходимо.

учебное руководство / руководство на компакт-диске, включая демонстрацию установки, эксплуатации и
техническое обслуживание, а также правила техники безопасности и т. д.

Объем поставки: должен быть предоставлен пакет, включающий
все необходимые аксессуары для установки и должны
включать запасные части / расходные материалы, необходимые для
один год при скорости горения до 8 часов
ежедневно

Гарантия должна быть предоставлена сроком на 5 лет.
начиная с установки инсинератора и
включая предоставление аксессуаров и
расходные материалы

Horizontal Solid Rubbish Incinerator



Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Key Features: 
* All models with Dual combustion chamber. *according to order 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane for Intelligent operation. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

The factory workshop local in liuhe Economic Development Zone, suburb of Nanjing and business office local in downtown area. Presently, incinerator line products market cover former Soviet Union area, Africa countries, Asia countries and middle east area.
From year 2010, we negotiated with updated technology from Europe and America manufacturers and establish cooperation relationship in the territory of China market. Unfortunately, poultry cremation equipment, poultry incinerator china, poultry incinerator in italy, poultry incinerators, poultry incinerators manufacturers, competition in other countries market, country discrimination and worries of intellectual property rights cause failure finally. Presently, we investment more effort, funds and technology development in our own brand, we are to be one of the largest incineration equipment in the world. We have trading branch company for professional export business service.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Контейнерный передвижной инсинератор для сжигания медицинских отходов Модель CA50

HICLOVER – контейнерная мобильная установка для сжигания медицинских отходов, модель CA50


Модель

CA50

Картина

Обработка отходов

Сжигание медицинских отходов

Емкость подачи

В среднем 100 кг на кормление

Скорость горения

В среднем 50 кг в час

Время горения на корм

В среднем 2 часа

Режим управления

ПЛК (Инсинератор с программируемым логическим контроллером)

Напряжение

220В

Мощность

1.0 кВт

Топливо

Дизельное топливо

Горелка

Италия Горелка

Режим подачи

Руководство по эксплуатации

Монитор температуры

Цифровой дисплей

Расход топлива (масло)

В среднем 16,9 кг / час

Внутренние размеры

100x80x 70см (Первичная камера)

Внешние размеры

230 х 130 х 155см (основной корпус)

Камера сгорания для отходов

560литров

Пост камера сгорания

280 литров

Емкость масляного бака

200 литров

Открытие двери

70 х 50см

Камин

5,0 млн

Вес брутто

4500кг

Материал камеры

Огнеупорный кирпич, огнеупорный бетон

Максимум. Тепловая ценность

166000 ккал / час.

Технические характеристики эксплуатации

Температура твердой камеры

800 0 С -1000 0 С

Температура газовой камеры

1000 0 С -1200 0 С

Камера Anti-Rate

1750 0 С

Время проживания

2.0 сек.

Эффективность горения

98%

Отходы с более низкой теплотворной способностью

3000 ккал


Установки для сжигания отходов
Установка для сжигания медицинских отходов
Кремация домашних животных
Твердые отходы   Мусоросжигатель

Телефон: + 86-25-8461 0201
Мобильный: + 86-13813931455 (WhatsApp / WeChat)
Сайт: www.hiclover.com
Электронная почта: [электронная почта защищена]
Электронная почта: [электронная почта защищена]
Наньцзин Клевер Медицинские Технологии Лтд.

2020-03-24

WASTE BROCHURES As Well As CONTAMINATED MATERIALS LIST

1 Burner 30 =KG burn/h and also it need to have a Scrubber.

2 Burner should have Electric Plastic Shredder for cutting of glass container, surange of Medication.

3 Burner need to have Electrical Car Clave or Microwave for Dis Infection independently with burner.
4 Incinerator needs to have Double Chambers initially Chamber should provided 800C temperature level as well as additional Chamber working 1200C temperature level.
5 Incinerator in out place must have a Specification to show internal temperature level of incinerator.
6 Burner has to operate in 2 systems Electric and also fuel explain in which type of fuel jobs.
Note we want it works on gasoline and also electrical also.for a small pig slaughterhouse task in Vietnam we are looking for a.
solution to ruin securely inedible and confiscated pet items.

As the slaughtered pigs are consumed by more than 90% (from hooves to.
head, blood, etc) the waste volume is fairly tiny also in.
slaughter-points with as much as 100 slaughtered pigs each day.

Although using meat and also bone meal is not banned in Vietnam the.
small quantities of waste do not seem to warrant the installment of a.
rendering system, not also of a batch stove, so incineration seems to be.
the very best option.

I wish to get even more technological details e.g. gas usage for.
blazing 100/200 kg of animal items per day as well as also the FOB.
cost of the unit.The types of waste to be treated are (after EUROPEAN WASTE BROCHURE AND CONTAMINATED MATERIALS CHECKLIST, 2002):

18 01 01 sharps (other than 18 01 03)

18 01 02 body components and organs including blood bags and also blood maintains (other than 18 01 03)

18 01 03 * wastes whose collection and also disposal undergoes special needs in order to avoid infection

18 01 04 wastes whose collection as well as disposal is not subject to unique requirements in order to protect against infection (for example dressings, cast, linen, disposable clothes, baby diapers)

18 01 06 * chemicals containing or consisting of unsafe compounds

18 01 07 chemicals besides those stated in 18 01 06

18 01 08 * cytotoxic as well as cytostatic medications

18 01 09 medications aside from those discussed in 18 01 08

18 01 10 * amalgam waste from dental treatment

fabricantes de incineradores china

El incinerador tomará el suministro del tanque de OD a través de sus bombas de alimentación de OD a sus respectivos quemadores. Un

Se instalará un medidor integrador para medir el volumen de OD consumido por el incinerador. Medición previa adecuada

Los filtros se deben proporcionar junto con una derivación bloqueable a través del filtro y el medidor. El medidor debe tener un

lectura digital en litros y registrará cantidades de 1 a 99999 con una precisión de ± 1%.

El control de las bombas de alimentación de OD y las válvulas de control asociadas será completamente automático. El sistema PLC controlará el

DO los quemadores automáticamente para lograr un consumo mínimo de aceite diesel durante el arranque y el servicio.

2.6 Condiciones del sitio:

Localización:

Port Louis, Mauricio

Temperatura ambiente: 18-35 ° C

Humedad relativa: 74 – 95%

Otros: Entorno corrosivo debido a la proximidad con el

mar

2.7 PRUEBAS DE FABRICACIÓN Y FÁBRICA

El Licitante seleccionado deberá realizar una prueba de ‘aceptación en fábrica’ del incinerador dentro de sus instalaciones /

laboratorio para verificar las cifras garantizadas El procedimiento de prueba, las instalaciones de prueba y los resultados de las pruebas del Licitante serán

Verificado y certificado por un organismo de acreditación internacional aprobado por CEB. incinerator es para uso en el hospital

para la quema de residuos peligrosos y químicos, capacidad mínima 300 por hora. Revenderé a mi cliente ?. A continuación es

la información que me dieron y nada más. El incinerador hospitalario para su uso en los desechos clínicos según lo requiera

gestión ambiental internacional. Capacidad mínima de 300 kg / h, combustión, revestimiento refractario, chimenea y toma de muestras.

prot. La temperatura mínima de 1100 grados Celsius amablemente me cotice el mejor precio para la reventa.

Tanzania’s Waste Management Challenges

Tanzania Hospital Waste Incinerator: UNDP Supported Projects and HICLOVER Solutions

Hospital waste management is a growing concern in Tanzania, where expanding healthcare infrastructure, rising population, and international donor-funded programs demand safe and sustainable disposal of biomedical waste. In recent years, initiatives such as the UNDP supported incinerator project in Tanzania and other UN projects and donor-funded healthcare facilities have emphasized the need for modern, reliable, and environmentally compliant incineration technologies. The HICLOVER hospital waste incinerator series has emerged as a strong solution, specifically designed for Tanzania’s environmental, regulatory, and operational conditions.

Tanzania’s Waste Management Challenges

Hospitals in Tanzania, from national referral hospitals in Dar es Salaam to regional facilities in Arusha, Mwanza, and Mbeya, face pressing challenges in handling biomedical waste. Infectious waste, sharps, and pathological residues are often mixed with general solid waste, creating high risks of contamination. Many district-level hospitals still rely on outdated brick incinerators or open burning, which fails to meet environmental standards.

At the same time, international donors including the United Nations Development Programme (UNDP), the World Bank, and bilateral partners have funded healthcare projects aimed at strengthening waste management systems. These programs specifically highlight the adoption of dual-chamber hospital waste incinerators with secondary combustion and sufficient gas retention time to reduce emissions such as dioxins and furans.

UNDP Supported Incinerator Projects in Tanzania

The UNDP supported incinerator project in Tanzania has targeted healthcare facilities across several regions, with emphasis on safe disposal capacity, environmental protection, and sustainable operation. Specifications from these projects often include:

  • Dual-Chamber Combustion: Primary chamber for waste destruction and a secondary chamber operating at 1000C1300°C with at least 2 seconds residence time.

  • Capacity Range: From small-scale 30 kg/hour units for rural health centers to 200C300 kg/hour systems for regional hospitals.

  • Flue Gas Treatment: Optional wet scrubbers and filtration systems to meet international emission standards.

  • Containerized Configuration: Mobile or modular systems that can be installed quickly without permanent civil works, suitable for remote hospitals and donor-supported clinics.

These requirements align closely with the HICLOVER TS Series of hospital waste incinerators, which have already been deployed in donor-funded projects across Africa, including in Kenya, Rwanda, Somalia, and Uganda.

HICLOVER Hospital Waste Incinerators for Tanzania

For Tanzania’s healthcare sector, HICLOVER offers specialized models designed to comply with both Tanzania Bureau of Standards (TBS) regulations and international benchmarks:

  • HICLOVER TS30 PLC: Compact incinerator for small hospitals and health centers, with 30C35 kg/hour capacity, twin chambers, and PLC-controlled operation.

  • HICLOVER TS200 PLC: Suitable for regional hospitals, with 180 kg/hour burn rate, 1.98 m3 primary chamber, and full PLC automation for safe handling of biomedical waste.

  • HICLOVER TS300 PLC: High-capacity unit with 220 kg/hour throughput, 2.4 m3 combustion chamber, dual chamber design, and optional wet scrubber system.

Technical Features Beneficial for Tanzania

  • PLC Automatic Control: Minimizes operator error and enhances safety.

  • Top Loading Design: Ensures easy waste feeding for hospital staff.

  • Italy-Brand Burners: Stable combustion with diesel or natural gas, both readily available in Tanzania.

  • Optional Containerized Build: Ideal for donor-funded projects requiring rapid installation at hospitals in rural or semi-urban areas.

  • High-Temperature Retention (HTR): Automated adjustment for efficient waste destruction and reduced fuel consumption.

UN and Donor-Funded Healthcare Facilities in Tanzania

Projects supported by UNDP, the World Bank, and other partners have provided incinerators for county-level hospitals, maternal health centers, and emergency response facilities. These installations are critical in preventing the spread of infections, especially in regions where outbreaks like cholera or Ebola pose risks.

By integrating HICLOVER hospital waste incinerators, Tanzania’s healthcare system benefits from:

  • Safe Disposal: Ensuring syringes, sharps, and infectious materials cannot be reused or cause contamination.

  • Environmental Compliance: Meeting WHO guidelines and donor funding conditions.

  • Durability in Harsh Conditions: Designed to withstand Tanzania’s coastal humidity, rural dust, and inconsistent power supply.

Conclusion

The demand for modern hospital waste incinerators in Tanzania continues to grow, driven by UNDP supported incinerator projects and other international donor-funded healthcare initiatives. The HICLOVER TS30 PLC, TS200 PLC, and TS300 PLC models provide proven solutions that meet both technical requirements and on-the-ground realities.

For hospitals, NGOs, and donor agencies seeking reliable waste treatment technology in Tanzania, HICLOVER containerized dual-chamber incinerators are the ideal choice for safe, efficient, and sustainable biomedical waste disposal.

For inquiries and technical specifications, visit www.hiclover.com or contact [email protected].


Mobile: +86-13813931455(WhatsApp)

Email:     [email protected]     
Email:     [email protected] 

 

2025-08-23/22:05:03

КАТАЛОГ ОТХОДОВ И ПЕРЕЧЕНЬ ОПАСНЫХ ОТХОДОВ

1 инсинератор 30 = кг сжигания / час, и в нем должен быть скруббер.

2 Мусоросжигательный завод должен иметь электрический пластиковый измельчитель для резки стеклянной бутылки, например, для медицины.

3 Инсинератор должен иметь электрический автоматический клав или микроволновую печь для дезинфекции отдельно от инсинератора.
4 Инсинератор должен иметь двойные камеры. Первая камера должна обеспечивать температуру 800 ° C, а рабочая температура вторичной камеры – 1200 ° C.
5 Установленная инсинератор должна иметь параметр, показывающий внутреннюю температуру инсинератора.
6 Инсинератор должен работать в двух системах. Электрическая и топливная. Укажите, в каком виде топлива работает.
Обратите внимание, мы хотим, чтобы он работал и на дизельном топливе, и на электричестве. Для проекта небольшой свиноводческой бойни во Вьетнаме мы ищем
решение для безопасного уничтожения несъедобных и изъятых продуктов животного происхождения.

Поскольку убитые свиньи съедаются более чем на 90% (от копыт до
голова, кровь и т. д.) объем отходов невелик даже в
пункты убоя до 100 свиней в сутки.

Хотя во Вьетнаме употребление мясокостной муки не запрещено,
небольшие объемы отходов, кажется, не оправдывают установку
единицы рендеринга, даже не печи периодического действия, поэтому сжигание кажется
лучший вариант.

Я хотел бы получить более подробную техническую информацию, например, расход топлива для
сжигание 100/200 кг продуктов животноводства в сутки, а также FOB
Цена единицы. Типы отходов, подлежащих переработке (по ЕВРОПЕЙСКОМУ КАТАЛОГУ ОТХОДОВ И СПИСОК ОПАСНЫХ ОТХОДОВ, 2002):

18 01 01 острые предметы (кроме 18 01 03)

18 01 02 части тела и органы, включая мешки для крови и консервы для крови (кроме 18 01 03)

18 01 03 * отходы, сбор и утилизация которых подлежат особым требованиям для предотвращения заражения

18 01 04 отходы, сбор и утилизация которых не подлежит особым требованиям для предотвращения заражения (например, перевязочные материалы, гипсовые слепки, белье, одноразовая одежда, подгузники)

18 01 06 * химические вещества, состоящие из опасных веществ или содержащие их

18 01 07 химические вещества, кроме упомянутых в 18 01 06

18 01 08 * цитотоксические и цитостатические препараты

18 01 09 лекарственные средства, кроме указанных в 18 01 08

18 01 10 * отходы амальгамы стоматологической помощи

dispose Medical waste IV

the incinerator can be made use of to get rid of Medical waste IV, used needles, made use of syringes, scalpels, used dressing material, individual safety devices like gown, gloves and so on truncated body parts, excreta from clients and also various other research laboratory waste.incineration devices that can handle a mix of clinical as well as contaminateds materials. The clinical wastes consist of (yet are not limited to) materials contaminated with blood, physical liquids, feces, and also human tissue/organs from surgical treatment. The dangerous compounds include (however are not limited to): xylene, toluene, chloroform, methylene chloride, trichloroethylene, acetonitrile, formaldehyde wastes, radiation treatment wastes (e.g., Chlorambucil, Cytoxin, Daunomycin, and so on) radiology wastes (e.g., glutaraldehyde), and mercury-containing compounds.includes amputated body parts, body fluids including contaminated blood, blood items, excreta from people, cultures of transmittable infections as well as various other research laboratory wastes e.t.c.
Medical might also consist of used needles, made use of syringes, made use of, expired or infected clothing products like plasters, plasters and plastics, e.t.c. The Burners ought to likewise enable disposal of other wastes created in healthcare facility environment.Technical Requirements for Portable Incinerators

The Chamber volume of around 0.37 m3 and also a.
1 combustible lots quantity (quantity of material) of.
around 0.30 m3

2 Burner power of around 189,000 kcal/hour.
Optimum Burning Temperature Level of approximately 1250

Degree Celsius.
Kind of sent out Gas: Inert as well as zero ecological air pollution effect.
Electric Power: 220V/50 or 60 Hertz

Fuel: Diesel

Electric intake of roughly: 0.35 kw/hr

Gas usage variety: 7 – – 11 ltrs/hr

Controls: Incinerator control including control panel, timer, display screen for keeping an eye on combustion temperature level, system mistake display screen, and so on
. Packaging/Installation: Burner completely set up as well as all set to be connected in power source

User’s manual: Bundle has to be given with user’s manual including described information to installment, procedure, upkeep, analysis of problem shooting signals and also contact telephones. numbers/emails of neighborhood or abroad supplier’s specialists that can be called for assistance on procedure of the devices, if required.

training guide/manual on a compact disc including a demonstration for installment, operation and also. maintenance, in addition to safety standards, etc.

Scope of Supply: Bundle needs to be supplied including. all the called for devices for installation and also must. consist of spare parts/consumables that are needed for a. one year period at a burning rate of approximately 8 hrs. daily

Guarantee must be provided for a 5-years period. beginning with the burner’s setup and. consisting of the arrangement of accessories as well as.
consumables

Incinerator Burner



Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover
Origin:Nanjing

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Please fill in following items and send back to us. Advantage of diesel hospital incinerator, algeria incinerators, animail incenrator, animal by-products of the incineration plant scheme, animal carcas incineration, We will study following important information and proposal our product models, specification and so on.

Item Customer Request Example
Application Scope  
 
 
 
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc
What kind of waste?  
____, _____%
____, _____%
____, _____%
 
 
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent
if for animal/pet, indicate animal size like: cat, dog, cattle, etc
Quantity Request    
01.02.03^..unit
 
Budget    
$US Dollar.
 
 
Operating Time    
The staff work Hours per day.
Our incinerator can work up to around 18 hours per day.
Realization Date of project In ___ year  
Waste Output Capacity per Day?  
 
1000kgs Per Day^
Request waste burn rate   Capacity: 100kgs Per hour^
Request waste feed capacity   Capacity: 100kgs per feed^
Whether Natural Gas Supply Local?   Yes or No.
Local Power   If 380V and 220V valid?
Product Installation Destination  
 
Country or City name
DestinationSeaport name?   To check sea freight charge.
 
Customer    
End-Customer, Agent, Government.
 
Method of contract   Tender or Negotiation
Date of Tender limit    
How did you know our company?    
Other request or information