Archive: September 15, 2026

medical waste incinerator manufacturer

GOODS:  ONE INCINERATORS IN ACCORDANCE WITH THE   SUPPLIER’    
REQUIREMENT   S OWN    
      PROPOSED    
         
      SPECIFICA    
      TION/      
      CONFIRM    
      ATION    
      SPECS    
  Incinerator walls and roof : 1550 °C castable monolithic refractory          
  concrete          
  Temperature: ≥90 °C          
  Insulation to walls: 1000 °C castable insulation          
  Electricity supply required: 220volt, 15amp single phase          
  Controls          
  Draught control: barometer indicator, door operated draught limiter          
  Air supply: built-in forced heated air ducts, primary and secondary          
  (intensifier)          
  Electric: control panel includes-circuit breakers, main switch, timer,          
  pilot lights, 2 set point pyrometer and one set point pyrometer          
             
  3.Experience and Qualifications          
  Experience and Qualifications          
  Company          
  The companies responding to this ToRs must have at least 5 year          
  experience of incinerator installation and maintenance or related          
  field. It must be registered, have trader’s licence and be compliant          
  with tax requirements.          
  Project Leader          
  The proposed expert should be able to demonstrate a breadth of          
  relevant experience in operations and maintenance of incinerators or          
  environmental management. The project leader should have at least          
  a degree in environmental management or mechanical engineering          
  or  related  field  with  at  least  5  year  experience  in  project          
  coordination.  Previous  work  in  Lesotho  or  Southern  African          
  Development Community (SADC) experience will be an advantage.          
  Health and Safety Officer          
  He/she  should  be  a  health  and  safety  professional,  such  as          
  occupational health and safety; safety, health and environment, with          
  at least 4 years of carrying out compliance inspections and audits of          
  incinerators or construction projects.  A minimum of a diploma in          
  health  and  safety  or  a  relevant  discipline  is  required.   Prior          
  experience in Lesotho will be an added advantage.          
37        

Animal Waste Incinerator



Basic Info.

Model NO.:dual chamber medical waste incinerator specific
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. 

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Hazardous waste incinerators in china, hospital incinerator design, incineration combustion chamber, incinerator 10 kg/h price, incinerator 500kg per hr, incinerator capacity calculation, Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 

Key Features: 
* All models with Dual combustion chamber. *according to order 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane for Intelligent operation. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 

The factory workshop local in liuhe Economic Development Zone, suburb of Nanjing and business office local in downtown area. Presently, incinerator line products market cover former Soviet Union area, Africa countries, Asia countries and Middle East area. 
From year 2010, we negotiated with updated technology from Europe and America manufacturers and establish cooperation relationship in the territory of China market. Unfortunately, competition in other countries market, country discrimination and worries of intellectual property rights cause failure finally. Presently, we investment more effort, funds and technology development in our own brand, we are to be one of the largest incineration equipment in the world. We have trading branch company for professional export business service.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

incinerator manufacturers

GOODS:  ONE INCINERATORS IN ACCORDANCE WITH THE   SUPPLIER’    
REQUIREMENT     S OWN    
        PROPOSED    
           
        SPECIFICA    
        TION/      
        CONFIRM    
        ATION    
        SPECS    
  Height from base: 11m and if there are buildings within 30m of the          
  incinerator, chimney must extend at least 3m above the apexes of all          
  the roofs of such buildings            
  Diameter of chimney at top: 430mm          
  Weight of stack: ± 500kg            
  case and stack be painted with 400 °C heat resistant black paint          
  Burners            
  1st chamber 850 oC -900oC            
  2nd chamber 1000oC            
  Variable speed combustion air blowers          
  Primary chamber volume ±1.05 cubic metres          
  Mixing chamber volume ±0.30 cubic meters          
  Settling chamber volume ±0.89 cubic meters          
  Weight excluding chimney ±6 400kg at manufacture          
  Firing tools supplied: Hoe, poker and rake          
  Dimensions            
  Length ±2 125mm            
  Width ±1 890mm            
  Height  ±2 125mm            
  Extra width for burners ±1 000mm          
  Loading door opening 610mm×540mm          
  Hearth area ±1.19 square metres          
  Description of grate/hearth: A full hearth to be supplied to prevent          
  contaminated  liquids  from  flowing  into  ash  pit  without  being          
  incinerated            
  Compliance with South African Atmospheric Pollution Prevention          
  Act No. 45 of 1965 or equivalent air pollution standard          
  Documents to be supplied : Operations and maintenance manual and          
  standard operating procedures (SOPs)          
  Emission controls:            
  heated refractory screen            
  Low velocity grit settling chamber          
  Stainless steel arrester screen            
  Refractory material: alumina content ≥49% and thickness average          
  102mm            
  Bake out: to be done over 2-3 days          
  Materials of construction            
  Case: 5mm mild steel            
  Bracing: heavy angle and channel          
  Hearth: 1550 °C            
  Ashing door: high grade cast iron          
  Loading door 5mm mild steel lined with 1550 °C castable general          
  purpose high strength, high abrasion resistant monolithic refractory          
  concrete            
    36        

INCINERADOR PIROLÍTICO de residuos clínicos

REQUISITOS TÉCNICOS: QUEMADOR PIRROLÍTICO

Parámetro Cumplimiento
Tipo de residuo Para el tratamiento de residuos médicos, categorías A, B, C, D, E
Tipo de incinerador Pirolítico
Tasa nominal de quemado 50 t0 60 kg / ha 3500Kcal / Kg
Cargando Carga manual, por lotes
De Ashing Eliminación de cenizas automática o manual por lotes
El incinerador debe evitar la liberación de humo negro y polvo fino durante la carga.
Capacidad de la cámara primaria 2-3 m³
El aislamiento de la cámara de combustión debe estar compuesto por ladrillos refractarios, con mayor contenido de aluminio y aislantes,
La placa de combustión en carborundo evitando la fijación de vidrios y escorias
Horas de funcionamiento / día > 10 horas
Temperaturas máximas de funcionamiento 1400 ° C
Temperaturas de funcionamiento normales (primaria) > 850 ° C
Temperatura de funcionamiento (secundaria) > 1100 ° C
Debe tener regulador de temperatura digital (regulador de temperatura en reloj digital)
Contenido de carbono de las cenizas <2%
La instalación debe estar completamente libre de humo visible y olores desagradables.
Tiempo de residencia en segunda cámara 2 segundos mínimo
El diámetro interno de la chimenea. : Ø 400
Altura de la pila > 8 m
Funcionamiento del quemador Encendido / apagado automático
Combustible Diesel
Consumo de combustible a capacidad raed > 7 kg de residuos / l
Consumo de electricidad <2kW a capacidad nominal
Tensión de funcionamiento 220 – 240 V CA 50 Hz
Piezas de repuesto Suministro por 1 año cotizado como opción
Consumibles Suministro por 1 año de funcionamiento a mencionar como opción
Garantía Soporte de repuestos y servicio: 1 año mínimo después de la puesta en servicio
Servicio de ayuda <72 horas
Cumplimiento del estándar de emisión BS3316 o estándar equivalente
Sistema de filtrado de procesos Scruber para ser mencionado como opción
Cumplimiento de fabricación CE BS EN 746-2-1997
Especificación de diseño Tipo A, B, C, D y E de desechos médicos
Instalación y puesta en servicio Incluido en condición de suministro
Capacitación en mantenimiento y uso preventivo y curativo del incinerador Formación de operadores incluida en oferta
Capacidad para tratar plástico No menos del 40% en peso

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals in Kenya

TECHNICAL INCINERATORS SPECIFICATIONS FOR 2 hospitals

 

INTRODUCTION

  • All the incinerators to be supplied and installed must meet the Government of Kenya waste Management Regulation 2006 in particular 3rdschedule regulation (26, 47) pertaining classification, standards, criteria, and procedure for installing/operating incinerators as authored by the National Environmental Management and Coordination (waste management) regulation 2006, legal notice No. 121 of 29th September 2006
  • The capacity of the incinerator required should be to the specifications with a capacity to burn 100kgs/Hr
  • The incinerator shall be run on a 3-phase power supply (mains)
  • For the technical evaluation, not only the treatment plant but the entire system will be considered.  It will be the responsibility of the Bidder to supply a full system, including all eventually additionally necessary secondary systems and additional equipment.
  • The system offered shall be designed to operate normally under the conditions of the purchaser’s country. The conditions include Power Supply, Climate, Temperature, Humidity, etc.
  • The Bidder must provide a warranty for one year.
  • All text, parameter etc. on all control operating interfaces as well as on information displays and on print-outs shall be in English language.
  • The Bidder is responsible for all permits and approvals for importation. The Bidder shall provide all the necessary documentation in order to facilitate the legal requirements for the installation and putting into use of the equipment.
  • Period of Execution is 90 days from contract signature for delivery to site and completion of all verification operations required for the issuance of provisional acceptance.
  • Representatives of the Contracting Authority and the Beneficiary, together with the Bidder’s representative, shall carry out the controls, testing and initial approval for provisional and final acceptance as.  The provisional and final acceptance shall take place at the final destination.
  • After-Sales Service: The Bidder is required to ensure that a maintenance, service and repair centre, which is authorised by the Manufacturer, and which is able to rapidly supply genuine spare parts and consumables recommended by the Manufacturer is available throughout the one year warranty period. In fulfillment of this requirement with their offer Bidders must submit a statement signed by a representative of the manufacturer:
    • Providing the name and address of its authorised maintenance, service and repair centre,
    • Confirming that this authorised maintenance, service and repair centre is able to rapidly supply genuine spare parts and the consumables recommended by the Manufacturer; and

 

  • The Bidder will be responsible to deliver and install all to be supplied equipment at to be set up waste handling areas in the Republic of Kenya. The Bidder shall deliver a time schedule over the complete construction and assembling period. The delivery and installation time must be agreed between bidders, target Hospital and the Contracting Authority. The treatment plant must arrive pre-assembled. The Bidder shall ensure that all parts of the plant transported by sea shall not be shipped as “deck cargo”.

 

  • It is expected that the Bidder cooperates closely with the contractor for the new waste handling building/area and will make available all needed technical information, drawing, etc. to the contractor.

 

  • The Bidder shall supply and install the incinerator with the following attached specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

           
TECHNICAL INCINERATORS SPECIFICATIONS FOR EAPHLNP
           
ITEM DESCRIPTION UNIT QTY RATE KSHS.
           
  Incinerator        
  To supply and install the following    2NO.    
  Hospital Incinerators to Nema standards        
  The following are the incinerator specifications :-        
A Ø      Waste type:      Mixed type 0,1,2,3 & 4 hospital/clinical bio hazard waste        
  Ø      Waste density:   125 to 350Kg/M³        
  Ø      Waste CV:        4000 KCAL/Kg        
  Ø      Moisture content:   10-25%        
  Ø      Estimated ash residue: 5-10%        
  Ø      Nominal capacity:   100Kg/hour batch load        
  Ø      Secondary chamber:  2 second @ 1100ºC        
  Ø      Environmental:    NEMA ACT           (EMCA) 1999        
                Clean Air Act 1999        
  BS3316 1987        
  Equipment Set      
  The Incinerator must comprise of: –        
  Ø      Manual Loading door (heavy duty steel door with appropriate refractory lining)        
  Ø      Horizontal solid hearth, refractory lined primary combustion chamber 800mm diameter x 2100mm long        
  Ø      Full sized bulk load/ash removal door        
  Ø      1 off diesel-fired ignition burner – temperature controlled        
  Ø      1 off combustion air supply fan and distribution system, automatic control        
  Ø      High capacity secondary combustion chamber 2 second @ 1100ºC with        
  Ø      1 off diesel-fired afterburner – temperature controlled        
  Ø      Control Panel – automatic operation        
  Ø      Temperature indication primary and secondary chambers 0-1200ºC. Both chambers must be insulated with refractory material (super duty 100mm thick firebrick with 25mm thick calcium silicate insulation)        
  Ø      Refractory lined flanged chimney to a height of 10M and it must be 3m above the height of any existing roof adjacent to the incinerator        
  Carried Forward To Collection Page.        
 

 

 

NOTE: WE REQUIRE TWO INCINERATORS. ONE        
ITEM DESCRIPTION UNIT QTY RATE KSHS.
B Diesel Tank:        
  To provide for diesel service tank (Capacity 400 litres) including level indicator

The tank should be connected to the incinerator at a higher level to enable free-flow of diesel from the tank to the incinerator. The connecting pipe must be a black pipe of approved gauge and diameter. Include other accompanying accessories and fittings

Item 1    
C Installation & commissioning works        
D Positioning of Incinerator: –

Provide lifting gears as forklift, gantry, rollers, and lifting jacks and position incinerator.

Item 1    
E Connect burners to fuel supply. No. 2    
F Chimney Installation:        
 G Composition of the chimney: –

Provide a chimney with scrubber (for filtration)

Provide lifting gear to hoist, erect and mount chimney, and provide supports slings as necessary. Allow for cutting of tree branches to facilitate the exercise.

The chimney shall be painted with approved heat resistant paint after installation.

Item. 1    
H Commissioning & Training:        
  Testing set operating parameters, training of operators and technical staff. Item 1    
I Commissioning Maintenance Contract        
  Before the expiry of the warranty/signing off, the suppler shall provide a one-year replacement service parts (e.g. filters, air filters), the Quarterly routine maintenance price per quarter for three (3) quarters. Maintenance contract proposal).  The maintenance contract price includes labour, transport and accommodation for the attending technicians. Item 3    

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EVALUATION CRITERIA

Evaluation shall be carried out in four stages namely preliminary examination of documents for conformance with mandatory requirements, technical evaluation, site visit and commercial evaluation.

Stage One: Preliminary Examination

– Preliminary Evaluation under special condition of the tender. These are mandatory requirements.

This shall include confirmation that a bidder has complied with the special condition of tender above.

Failure to meet any one of the above requirements stated in the special conditions of the contract shall lead to automatic disqualification.

Stage Two: TECHNICAL EVALUATION (70 MARKS)

 

ITEM DESCRIPTION UNIT QTY MARKS ALLOCATED   MARKS RECEIVED  
           
  Incinerator        
  To supply and install the following    2NO.    
  Hospital Incinerator to Nema standards        
 

 

The following are the incinerator specifications :-        
           
A Ø      Waste type:      Mixed type 0,1,2,3 & 4 hospital/clinical bio hazard waste     35  
  Ø      Waste density:   125 to 350Kg/M³        
  Ø      Waste CV:        4000 KCAL/Kg        
  Ø      Moisture content:   10-25%        
  Ø      Estimated ash residue: 5-10%        
  Ø      Nominal capacity:   100Kg/hour batch load        
  Ø      Secondary chamber:  2 second @ 1100ºC        
  Ø      Environmental:    NEMA ACT           (EMCA) 1999        
                Clean Air Act 1999        
  BS3316 1987        
  Equipment Set      
  The Incinerator must comprise of: –        
  Ø      Manual Loading door (heavy duty steel door with appropriate refractory lining)        
  Ø      Horizontal solid hearth, refractory lined primary combustion chamber 800mm diameter x 2100mm long        
  Ø      Full sized bulk load/ash removal door        
  Ø      1 off diesel-fired ignition burner – temperature controlled        
  Ø      1 off combustion air supply fan and distribution system, automatic control        
  Ø      High capacity secondary combustion chamber 2 second @ 1100ºC with        
  Ø      1 off diesel-fired afterburner – temperature controlled        
  Ø      Control Panel – automatic operation        
  Ø      Temperature indication primary and secondary chambers 0-1200ºC. Both chambers must be insulated with refractory material (super duty 100mm thick firebrick with 25mm thick calcium silicate insulation)        
  Ø      Refractory lined flanged chimney to a height of 10M and it must be 3m above the height of any existing roof adjacent to the incinerator        
           
ITEM DESCRIPTION UNIT QTY RATE KSHS.
B Diesel Tank:        
  To provide for diesel service tank (Capacity 400 litres) including level indicator

The tank should be connected to the incinerator at a higher level to enable free-flow of diesel from the tank to the incinerator. The connecting pipe must be a black pipe of approved gauge and diameter. Include other accompanying accessories and fittings

Item 1 20  
C Installation & commissioning works        
D Positioning of Incinerator: –

Provide lifting gears as forklift, gantry, rollers, and lifting jacks and position incinerator.

Item 1 10  
E Connect burners to fuel supply. No. 2 5  
F Chimney Installation:        
 G Composition of the chimney: –

Provide a chimney with scrubber (for filtration)

Provide lifting gear to hoist, erect and mount chimney, and provide supports slings as necessary. Allow for cutting of tree branches to facilitate the exercise.

The chimney shall be painted with approved heat resistant paint after installation.

Item. 1 10  
H Commissioning & Training:        
  Testing set operating parameters, training of operators and technical staff. Item 1 10  
I Commissioning Maintenance Contract        
  Before the expiry of the warranty/signing off, the suppler shall provide a one-year replacement service parts (e.g. filters, air filters), the Quarterly routine maintenance price per quarter for three (3) quarters. Maintenance contract proposal).  The maintenance contract price includes labour, transport and accommodation for the attending technicians. Item 3 10  
  TOTAL      

100

 

 

Pass mark for technical evaluation is 70/100 marks

 

Stage Three: Site Visit

The evaluation committee will visit the premises of the bidders who are responsive to technical  evaluation stage to verify the authenticity of statutory document submitted; ascertain the accuracy of the information given in the tender documents, assess firm’s capacity, location, among others.

The Tenderer will be automatically disqualified where false or fraudulent Information is found to have been given.

 

Stage 4 Commercial Evaluation

Bids that pass the above three (3) stages shall be compared on the basis of prices / cost quoted and the lowest priced will be considered the lowest evaluated bid and subsequently recommended for award. Prevailing market prices will be used to determine the price responsiveness of the bidders.

 


SECTION V – SCHEDULE OF REQUIREMENTS

 

ITEM

NO

ITEM DESCRIPTION UNIT QTY. REQUIRED UNIT PRICE (KHS) REMARKS
1. Supply, Delivery, installation and commissioning of Incinerator in  

 

 

NO

 

 

 

 

 

 

1

   
2. Supply, Delivery, installation and commissioning of Incinerator  

 

 

NO

 

 

 

 

 

 

1

   

 

 

 

 

Signature of tenderer

 

Note: In case of discrepancy between unit price and total, the unit price shall prevail.

 

SECTION VI – STANDARD FORMS

 

  1. Form of tender
  2. Contract form
  3. Confidential Questionnaire form
  4. Tender security form
  5. Performance security form
  6. Bank guarantee for advance payment
  7. Declaration form

 

 

 

 

incineradores en 3 instalaciones para refinar los desechos de atención médica

una. 2.5 cargas métricas por día quemador de residuos sanitarios

B. 1,5 montones métricos por día quemador de residuos sanitarios

C. Quemador de desechos de atención médica de 300 kg por día

Nuestra tecnología preferida es la incineración de doble cámara, pero si sugiere una tecnología moderna diferente, eso es aceptable.

Solicitamos información sobre lo siguiente para cada una de las demandas anteriores:

1. Costo de capital (gasto proporcionado en Omán)

2. Gastos de funcionamiento y mantenimiento (anualmente)

3. Número de conductores solicitados

4. Especificaciones del artículo (tamaños, niveles de temperatura, tiempo de la casa, tiempo de ciclo, etc.)

5. Varios otros equipos auxiliares necesarios o recomendados por usted

Hopital Equipment



Basic Info.

Export Markets:Global

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, medical waste incinerator 150 kgs/hour, medical waste incinerator 15kgs per hour, medical waste incinerator 300kg/time, china, medical waste incinerator and a biological, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

00 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS

1) Policy

– Waste disposal management shall be taken special note to prevent hospital infection.

– Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site.

 

2) Waste Disposal Plan

  1. a)Classification

– Medical wastes in hospital are classified as follows;

 

Infections Waste Specially-controlled waste Organ, needle, etc.
Industrial waste Rubber gloves, etc.
General waste Gauze, etc.
General Waste Plastic, Rubber Infusion bottle, etc.
Paper, wood, Vinyl Voucher, etc.
Metal, Glass Can, Glass bottle

 

  1. b) Infections Waste Disposal

– Segregation: Infections waste disposal shall be segregated appropriately and packed in particular containers and delivered to particular storage. The segregation, packing and delivery shall be operated appropriately at each room such as outpatient, operation theater, blood collection room and dialysis room.

– Precaution: Infections waste shall not be place in other containers on the way of segregation, packing and delivery.

– Storage: Infections waste shall be stored at the storage in hospital site temporarily until infections waste is incinerated.

– Incinerator:

 

It is designed to sterilize medical waste , reduce its volume , and render its components unrecognizable all in one fully enclosed and automated system.

It combines direct heated steam , high pressure and shredding to treat infectious materials.

The contaminated waste is loaded into the upper stainless steel chamber where a heavy-duty shredder reduces the waste into small pieces. Using gravity, the processed material falls into the treatment chamber where every piece is steam heated to 134 and pressurized to 3 to bar for 20 minutes. The operating conditions are continuously monitored and validated to achieve complete sterilization.

The 60 minutes average duration process cycle is totally automated. A computerized system monitors the process and automatically prints a report with the essential sterilizing parameters at the end of the cycle for accurate record keeping.

The capacity is between 500 to 600 kg/cy.h or more.

Treatment cycle:

1- Loading ; the contaminated waste is automatically -loaded into the chamber of the unit

2-Shredding; the heavy-duty shredder cut the material into small pieces and features a unique reversing system to avoid jamming

3-Heat; saturated pressurized steam raises the temperature to 134 C and the pressure to 3 bar

4-Sterilization; the sterilization comes into direct contact with the shredding material (134 c , 3 bar) for 20 minutes

5-Cooling; temperature is lowered to 80 C by spraying cool water onto Double jacket of the treatment vessel, simultaneously, the unit returns to ambient pressure

6-Draining; the steam is condensed to water and discharged with the cooling water to the sanitary sewer system

7-vacuum; the remaining residual steam is vented out through a vacuum pump

8-Unloading; a digital signal informs the operator that all safe operating conditions have been met

The condition unlocks the unit and allows gravity unloading of the treated waste into a container

Teaching Specification

General Characteristics

Operational temp. max 160 C
Max Weight when filld with waste For a special hydraulic test. Kg 10500
Stress. Kg/ cm3 3.5
Steam Pressure. Bar 8
Max Steam Flow Kg/h 500
Compressed Air Bar 6
Electricity 380 V/3 – phase Surge Protection system 35KW
Operating Characteristics
Average Cycle Time. minutes 60
Process Wight Capacity . Kg 500 – 600
Density. Kg/m3 100
Average process wight capacity Kg./cycle microbial inactivation 200-300

8log 10

Waste volume reductin 80%
Consumption / Cycle
Steam. Kg 40
Electricity . KW/h 9
Water Liters 500

 

arrojar desechos peligrosos y también incineradores de chimeneas

3 tipos de incineradores, que son de 10 kg, 20 kg y 30 kg para nuestro centro de Tawfiq Healthcare en Malindi, Kenia. somos un

empresa de consultoría ecológica, como he comentado anteriormente, actualmente tenemos un contrato con una empresa francesa concentrada en

venta de quemadores de desechos sólidos (ATI) y también compramos un crematorio para la disposición de desechos sólidos, que consta de $ 180

miles de dólares, así como ahora deseamos entrar en el negocio de la comercialización de incineradores de residuos pet, así como ya que no tiene un

agente en Arabia Saudita. Los tres modelos que ha indicado se basan en un funcionamiento las 24 horas. ¿Podrías hacer lo ideal?

referencias para un turno de 8 a 10 horas todos los días (incluido el tiempo de enfriamiento)? Supongo que sin duda necesitaremos incineradores de mayor capacidad para

cada uno de los 3 requisitos. Estoy interesado en comprender requisitos y tarifas más completos para su incinerador SYC-20. I

permanezca en el mercado por un quemador pequeño y fácil de operar, sin embargo, tenga poca o ninguna experiencia con tales cosas.

instalación y edificación y construcción de RESIDUOS SÓLIDOS
COMPLEJO DE GESTIÓN, para esa función necesitamos Dieciséis (16) ton / día (7.538 kg / día) del Sistema de Quemador Ability. 1,5 toneladas de basura

diario,

llamado para número de dispositivos -10 a 25 números

Instalación de varios tipos de sistemas de monitoreo de desechos, idealmente Incineración y otros para el estado de Jammu y Cachemira India

fabricante y también comerciante de varios incineradores y otros artículos.

Tenga en cuenta que somos una empresa líder en Bangladesh que se ocupa de varios centros médicos, quirúrgicos, dentales y de salud.

artículos, planta y equipo, etc.

Lo esencial es transformador, motor eléctrico 220v, termopar de temperatura, soplador del quemador principal.

base sobre este incinerador móvil,
1. el tipo de residuo para el que se puede utilizar (terapia). Incineradores de residuos de instalaciones sanitarias con reducción de dióxido de carbono o CIF khartom–

Sudán

Diseños de quemadores de desechos clínicos para instalaciones médicas de cama 100-300 y cama 100-1000, envíe un presupuesto de todas las versiones YD

y modo de trato / entrega a nigeria

El quemador es para uso en el hospital para eliminar desechos peligrosos y también chimeneas, capacidad mínima de 300 por hora.

El quemador de hospital para uso en los desechos médicos según lo requiera la administración ecológica global. Mínimo 300 kg

capacidad / hr, combustible descargado, refractario revestido, pozo de humo y también degustación prot. Temperatura mínima de 1100 grados Celsius cotización de precio amable

me mejor costo para la reventa. El costo ideal para la reventa de entre $ 7000 a $ 12000 Usd Ya tengo cotizaciones solo requiere el

costo ideal por favor. el precio debe ser CIF Johannesburgo o Durban

incinerator manufacturer

“PYROLYTIC” combustion, by controlling the gasification of waste

The incinerator manufacturer must avoid the release of black smoke and fine dust, during the loadings.

It shall be able to reduce the volume of wastes by 98%.

It shall be able to hold emission in the second burn with gas residence of not less than 2 seconds.

 

The incineration should be completely free from visible smoke as well as offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

The primary combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a

complete layer of hote face refractory and high efficiency insulation.

The Internal diameter of the Chimney at least: ? 400 and its height: 8 m