Archive: March 9, 2026

HIGH TECH MEDICALWASTE INCINERATOR

Incinerator model A
Burn Rate 65kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
I000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Warranty, indicate no of years
i.    The primary combustion chamber shall be accepted as the primary combustion zone;
ii.    The minimum combustion temperature of the primary chamber shall not be less than 800 degrees C;

Secondary combustion
The residence time in the secondary chamber shall not be less than 2 seconds;
The gas temperature as measured against the inside wall in the secondary chamber, not in the flame zone, shall not be less than as indicated in Lots 1-7 ;
Both the primary and the secondary temperatures shall be maintained until all the waste has been completely combusted;

Chimney
The chimney shall have a minimum height of 4 meters above ground level;
The minimum exit velocity of the emissions shall not be less than 10 metres/second;

Temperature Warnings
An audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature;

General
Control box can be detached and mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter height;

Lot 2
Item 5    Incinerator model B
Burn Rate 150kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Diesel/LPG/LNG, please indicate
Power Supply for Control Box- 220V-240V 50Hz single phase
Minimum operating temperature 920 °C, please indicate
One year Spare Parts Package for complete maintainability
Item 6    10m Hose Pipe, indicate length
Item 7    I000 Litre Fuel Tank + Pipe System, indicate volume
Item 8     Additional chimney extension, indicate height
Warranty, indicate no of years
Lot 3
Item 9    Incinerator model C
Burn Rate 250kg/h minimum
Weight (kg) please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box 220V-240V 50Hz single phase
Minimum operating temperature 920 °C, please indicate
One year Spare Parts Package for complete maintainability
Item 10    10m Hose Pipe, indicate length
Item 11    I000 Litre Fuel Tank + Pipe System, indicate volume
Item 12    Additional chimney extension, indicate height
Warranty, indicate no of years
Lot 4 – High Temperature Waste Incinerator
Item 13    HTW Incinerator model D
Burn Rate – 150kg/hour minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box 220V-240V, single phase 50-60Hz
Minimum operating temperature 1200°C, please indicate
One year Spare Parts Package for complete maintainability
Item 14    10m Hose Pipe, indicate length
Item 15    1000 Litre Fuel Tank + Pipe System, indicate volume
Item 16    Additional chimney extension, indicate height
Warranty, indicate no of years
Lot 5 – Mobile Incinerator
2.    Incinerator provides 2 chamber incineration and holds gasses for a minimum of 2 seconds.
3.    Each incinerator must have adequate labelling for parts/areas of high occupational health and safety risk on the incinerator.
4.    Evidence their product meets relevant national or international emissions standards, such as the United States Environmental Protection Agency, United Kingdom Department for Environment Food
& Rural Affairs, or European Union regulations and directives.

Item 17    Mobile Incinerator model E
Burn Rate 50kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
Item 18    10m Hose Pipe, indicate length
Item 19    1000 Litre Fuel Tank + Pipe System, indicate volume
Item 20    Additional chimney extension, indicate height
Lot 6 – Mobile Incinerator
Item 21    Mobile Incinerator model F
Burn Rate 100kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 850 °C, please indicate
One year Spare Parts Package for complete maintainability
Item 22    10m Hose Pipe, indicate length
Item 23    1000 Litre Fuel Tank + Pipe System, indicate volume
HTW Mobile Incinerator model G
Burn Rate 100kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate
Power Supply for Control Box – 220V-240V 50Hz single phase
Minimum operating temperature 1200 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
1000 Litre Fuel Tank + Pipe System, indicate volume

instalar un calentador descargado de diesel

resplandecen principalmente medicamentos (todo tipo de tipos de dosificación………… jarabes, tabletas, inyectables) consumibles clínicos, además de también líquidos biológicos ………….
Capacidad alrededor de 10 kg / h. Instale un quemador con descarga diésel que pueda albergar toneladas de recolección de aproximadamente 100 kg con un requerimiento diario de combustión de aproximadamente 500 kg por día de 8 horas. Quemador industrial para dañar.
los medicamentos se desperdician como Alu, PVC, PVDC, etc. ¿Instalación para la quema de desechos de perros, costo, existencia, términos de liquidación donde es factible adquirirlos en Rusia? Mi objetivo es una capacidad de entre 200 y 400 kg.
1.2 PINTURA DEL ÁREA.
Realice la pintura necesaria para el área no especificada o no especificada, y también pintura de superficie de las cosas recién marcadas en la fábrica

1.3 ENTRENAMIENTO DE UBICACIÓN.
una. Envíe [6] duplicados completos de las pautas operativas que establezcan los procedimientos detallados necesarios para la puesta en marcha, operación y cierre del sistema. Consiste en las pautas del nombre del proveedor, número de versión, guía de servicio, anotación de piezas, así como un resumen rápido de todas las herramientas además de sus atributos operativos típicos. Además de [Seis] duplicados completos adicionales de las instrucciones de mantenimiento que brindan terapias de mantenimiento regulares, averías factibles y, además, soluciones de reparación, guías de reparación, además de representaciones esquemáticas optimizadas para el sistema tal como está configurado.

3.6. Eficacia.
Precaliente el incinerador durante 4 horas para alcanzar la temperatura de disparo de 982 grados C [1800] grados F. Pese y pegue con cinta adhesiva el peso de la tarifa general. Cargue el quemador a la capacidad nominal de combustión en kg de libras extra por hora durante un período de [4] horas, además de funcionar de acuerdo con las pautas escritas del fabricante. Incluir en las pruebas de rendimiento el tratamiento de las instalaciones de facturación mecánica, el quemador, las herramientas de control de la contaminación del aire, las cenizas.
Realizar pruebas a escala completa para un ciclo de procedimiento completo y, de la misma forma, vigilar el rendimiento para validar el cumplimiento del acuerdo requiere enviar un registro de los resultados de seguridad. Una vez que el quemador se haya enfriado realmente, piense en los residuos. El peso del depósito no superará el 5,0 por ciento de producto combustible del peso total de la carga.
Después de la limpieza, el quemador dejará caer cualquier tipo de evidencia de desgaste, como refractario descascarillado o derramado, doblado de componentes, junto con pintura exterior manchada.

– – Control.
Pruebe el incinerador bajo verdaderos problemas de disparo. Valide con pruebas que todos los controles funcionan dentro de las restricciones óptimas y mínimas de temperatura o tiempo. Imita problemas genuinos de alto riesgo, como calentamientos y también fallas de incendio, reduciendo las configuraciones para la activación de la limitación y los controles de seguridad.

– – Temperatura de tratamiento.
Opere el quemador con problemas típicos de lotes por no menos de 6 horas. – – Sistema de gas: Doble gas (tanto aceite como también gas)

Инсинераторы

сжигают 5000-10000 кг в час. В основном это отходы из резервуаров для сырой нефти. стоимость строительства, монтажа и 6 месяцев обслуживания, включая технические характеристики. CMSD для двухкамерной роторной инсинератора типа Клин (температура 1-й камеры не менее 850 градусов Цельсия и температура 2-й камеры не менее 1200 ° C с выхлопной трубой длиной 100 метров с механизмом фильтрации выхлопных газов) , Гидроклав (медицинский) с вспомогательным оборудованием. Рабочие параметры: температура 250-275 градусов Фаренгейта, давление 15-35 фунтов на квадратный дюйм, время стерилизации 30 минус, емкость партии -463 кг. два мусоросжигательных завода для больницы в ВН. Предполагаемая мощность составляет около 1000 кг в сутки.

Infectious Waste Incinerator



Product Description

Principle of the Incinerator equipment is incineration/combustion/burn. Generally, the function is waste treatment for Solid waste, Liquid waste, Gas waste, etc. 

The main body is one combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is external oil or gas burner. The burner can be running until waste burnout but for some waste like plastic, paper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner has small medical incenerator, small medical office waste incinerators, small medical waste incineration, small medical waste incinerator manufacturers, small medical waste incinerators in china, a fan itself for Oxygen supply and also protect burner avoid heat damage from combustion chamber. And, there a external fan blow air into combustion chamber. The Exhaust gas blow out after combustion. 

Considering Environmental Protection requirements and rules, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even if third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure sufficient combustion, few black smoke and smell. 

The updated incinerator technology focus on Exhaust gas treatment to remove Hazardous material and other function from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation. 

In some Developed countries, some new waste treatment method like High-temperature cooking, waste carbonization, crushing sterilization technology is instead of incineration technology.

Item Customer Request Example
Application Scope  
 
 
 
Hospital, Pet Crematory, Slaughter House, Laboratories, School, Community, etc. if for animal/pet, indicate animal size like: cat, dog, cattle, etc
What kind of waste?  
____, _____%
____, _____%
____, _____%
 
 
Medical waste, dead animal, Municipal Waste, etc(detail name) or nature percent
if for animal/pet, indicate animal size like: cat, dog, cattle, etc
Quantity Request    
01.02.03^…unit
 
Budget    
$US Dollar.
 
 
Operating Time    
The staff work Hours per day.
Our incinerator can work up to around 18 hours per day.
Realization Date of project In ___ year  
Waste Output Capacity per Day?  
 
1000kgs Per Day^
Request waste burn rate   Capacity: 100kgs Per hour^
Request waste feed capacity   Capacity: 100kgs per feed^
Whether Natural Gas Supply Local?   Yes or No.
Local Power   If 380V and 220V valid?
Product Installation Destination  
 
Country or City name
DestinationSeaport name?   To check sea freight charge.
 
Customer    
End-Customer, Agent, Government.
 
Method of contract   Tender or Negotiation
Date of Tender limit    
How did you know our company?    
Other request or information  
 
 
 

Система зажигания

Зажигалка
Поставка, установка и испытание установки для сжигания медицинских отходов производительностью 75 кг / час, работающей на сжиженном нефтяном газе, включая все аксессуары с дымоходом, в соответствии с техническими спецификациями и правилами общественного здравоохранения. Пункт 2
Помещение для сжигания 3-х мусоросжигательных печей как позиция 3-1-1 и хранилище отходов для хранения отходов в течение 7 дней, включая все конструкции из железобетона с зажигательной установкой и складским оборудованием, всю электропроводку, освещение, водоснабжение и канализацию. Пункт 1
Обеспечение помещения для сжигания мусора и хранилища отходов системой пожаротушения, включая спринклеры, утверждение источника воды на объекте, система пожарной сигнализации содержит датчики тепла и дыма, которые должны быть связаны с системами пожарной сигнализации в больнице. Пункт 1
Поставка, установка и испытание системы вентиляции помещения и хранилища зажигательной печи ВЫТЯЖНЫМИ ВЕНТИЛЯТОРАМИ ROOF TOP с HEPA ФИЛЬТРОМ, скорость смены воздуха 5 раз в час, с воздуховодами и решетками. Пункт 1
Поставка, установка и испытание КАНАЛИЗАЦИОННЫХ РАЗЪЕМНЫХ БЛОКОВ на складе для отходов с достаточной емкостью для поддержания внутренней температуры на уровне 14 градусов Цельсия летом и зимой. Пункт 1

Incinerador diésel de 50 a 60 kg / h y de 100 a 120 kg / h

Calentador diésel de 50 a 60 kg / h y de 100 a 120 kg / h 1. Capacidad para incendiar la adherencia a los tipos de residuos:
Los miembros de la familia desechos, vidrio, acero, contenedores de aluminio livianos y ligeros, así como también extrusiones de ventanas, contenedores de acero (rotos), madera, llantas, productos blandos, contenedores de plástico, paquetes de estrés, desechos médicos y desechos de cuarentena.
2. Capacidad ardiente requerida:
Alrededor de 4.500 cargas al año. El incinerador debe ser eficaz para incendiar el tipo de desechos discutidos o cualquier tipo de mezcla de los mismos a un costo de 3 montones por hora. Si es necesario, el sistema ciertamente se producirá para completar al menos cinco días consecutivos sin parar.
3. Requisitos de diseño del quemador:
El sistema debe ser sencillo en diseño y tratamiento, con elementos digitales marginales.
El quemador, así como la tecnología moderna de control de la contaminación del aire vinculada, sin duda será:
a. Combustible de apoyo de bajo uso;
b. bajo consumo de energía eléctrica;
c. Requiere muy poco procesamiento previo de los residuos fuertes del vecindario;
d) El sistema de contaminación del aire cumplirá la Directiva de incineración de residuos de la UE 2000/76 y, además, creará parte de la disposición completa del incinerador.
3.1 Información particular que debe proporcionarse el diseño
3.1.1 Detalles del quemador:
Capacidad de lotes de lotes;
b. Estilo de la cámara primaria (espesor, diámetro, tamaño, aislamiento, revestimiento celular, cantidad de área de la chimenea, peso); C. Diseño de la segunda cámara (densidad, tamaño, tamaño, aislamiento, revestimiento celular, ubicación de la chimenea de volumen, peso) ;.
c. Estilo de la pila de escape (espesor, diámetro, variedad de áreas de revestimiento, tamaño total de la pila, elevación sobre la base, peso) ;.
d.Tipo y variedad de sistemas de calefacción de gas de apoyo ;.
e.Demandas de combustible– – tipo, cantidades ;.
f.Uso de energía eléctrica ;.
g. Soluciones eléctricas requeridas ;.
h.Demanda de agua– – cantidades ;.
i.Cualquier otra necesidad de insumos y también consumibles ;.
j.Temperaturas que deben alcanzarse para lograr una destrucción adecuada de los desechos y también cumplir con las necesidades de control de la contaminación del aire (Directrices de la UE sobre incineración de desechos 2000/76) ;.
k.Tiempo de residencia para asegurar una destrucción óptima de los desechos y seguir los criterios necesarios para el control de la contaminación del aire.
l.Posible disminución del peso (porcentaje) de los desechos ;.
m.Opciones para mostrar de forma inmediata y constante, así como información del documento, como días, hora del día, establecer un número secuencial ;.
n Un letrero estético o de temperatura para revelar el estado del calor del equipo; así como igualmente.
o.Detalles sobre pantallas visuales además de / o artilugios de grabación del sistema informático.

3.1.2 Información del sistema de control de la contaminación del aire.
El tipo de dispositivos de control de la contaminación del aire seleccionados ciertamente cumplirán con la incineración de desechos WID de la UE.
b.Directiva 2000/76 ;.
c. Detalles sobre los sistemas de limpieza de gases para mejorar la eliminación de pequeñas partículas excelentes, gases ácidos y también sustanciales.
d.metales ;.
e.Detalles sobre aspectos, tales como :.
bebida refrescante;.
condensador / absorbedor ;.
depurador venturi ;.
separador de arrastre y también.
descargas pila (s).
Uso de energía eléctrica ;.
f. Cualquier otra necesidad de insumos además de los consumibles (por ejemplo, cal);
g. Detalles sobre pantallas gráficas junto con / o dispositivos de grabación del sistema informático;
h. Requisitos ambientales – – – – El sistema tendría absolutamente la capacidad / capacidad para seguir los estándares esenciales de calidad del aire; Política de incineración de residuos de la UE 2000/76. (o estándares comparables, así como requisitos aceptables para la División de Configuración del Gobierno Federal del Commonwealth de Australia) ;.
i) Especifique los criterios de contaminación del aire que se deben vigilar.
3.1.3 Demandas del sitio para el quemador.
a.Dimensiones de la superficie total de la tierra ;.
b) Infraestructura requerida (suministro de agua, drenaje de agua del suministro de energía); y también.
c. Cualquier aspecto particular ecológico o climático / meteorológico que requiera consideración.
3.1.4 Necesidades de vivienda y estilo.
a. Detalles sobre las demandas de una unidad protegida para el quemador y también un sistema de control de contaminación del aire conectado. El espacio se hará absolutamente para obtener demandas de seguridad y salud relacionadas con el trabajo tales como: a. El espacio libre se ofrece convenientemente en todos los lados, así como la radiación cálida se mantiene al mínimo ofreciendo a los operadores un :.
ambiente conveniente de b.easy así como también flujo de aire ;.
c.Existen instalaciones seguras para el almacenamiento de residuos ;.
d.Existen medidas para mantenerse alejado de las alimañas y los insectos.
e.Los productos serán de suficiente espesor arquitectónico para la seguridad y para resistir frente a la oxidación del mar.
4. Manuales de formación, mantenimiento e instrucciones.
4.1 Manuales de mantenimiento.
Suministrar información sobre demandas de mantenimiento, tales como :.
a. Limpieza general además del mantenimiento– – consistencia, habilidades / experiencia tecnológica necesarias ;.
b) Vida útil esperada de los elementos, así como del sistema en su conjunto.
c) Consistencia esperada de la demanda de reemplazo de componentes.
d.Disponibilidad de piezas y lugar de proveedores ;.
e) Frecuencia de necesidad de revisiones sustanciales; y adicionalmente.
f. Tiempo de inactividad estimado necesario para el mantenimiento general, así como revisiones importantes. Un quemador para nuestras mascotas muertas en el rancho ganadero, particularmente las aves.

Specifications for Double Chamber Incinerator

INCINERATOR DESCRIPTION
The Model is for up to 300kgs capacity per batch load and will burn at around 55kgs per hour.
The unit has top loading design and has a heavy duty refractory cement lining for maximum heat retention. Unit have large top lid for easy loading, and specially designed front ash door, for ash removal.
This unit operates at over 1100°C in the primary chamber to ensure complete combustion. This model also benefits
from a heavy duty secondary chamber and burner which ensures a complete re-burn of any smoke and emissions and a 0.5 second gas retention time.
Burn rate    150kg/h minimum
Secondary Chamber    Yes
Gas Retention Time    2 seconds
Fuel    Diesel/LPG/LNG
Power Supply for Control Box    220V-240V 50Hz single phase
Minimum Operating Temperature    920˚C

PRIMARY CHAMBER
Heavy-duty steel casing
High quality refractory lining and insulation
Large full size top load door and liquid retention sill
1 x diesel oil fired ignition burners operated on/off
SECONDARY CHAMBER
Heavy-duty steel casing
High quality refractory lining and insulation
1 x diesel oil fired ignition burners operated on/off
Specifications for Double Chamber Incinerator:
Primary Combustion
The primary combustion chamber shall be accepted as the primary combustion zone.
The minimum combustion temperature of the primary chamber shall not be less than 800 degrees c
Secondary Combustion
The residence time in the secondary chamber shall not be less than 2 seconds
The gas temperature as measured against the inside wall in the secondary chamber ,not in the flame zone shall not be less than as indicated in Lot 1-7
Both the primary and secondary temperatures shall be maintained until all the waste has been completely combusted
Chimney
The chimney shall have a minimum height of 4 metres above ground level
The minimum exit velocity of the emissions shall not be less than 10metres/second
Temperature Warnings
An audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature
General
Control box can be detached and mounted on separate stand of atleast 1.5metres from the incinerator at approximately 1.6 metre height
CE compliant or equivalent for incinerators of this size and model
Drawings and photos for the offered lots
1 year spare parts,fuel tanks and 10metre hose to come standard with every incinerator
Specifications for Mobile Incinerator Units
Trailer mounted mobile incinerator units suitable for the following applications
Medical waste
Domestic waste
Industrial waste
Animal cadavers
CHIMNEY
Heavy-duty stainless steel casing
1.5m length
0.6m refractory lined stack
CONTROL PANEL
Control of 1 burner
Timer control 0- 12 hours
Integral fan timer control
Temperature Monitoring
Thermostatic Control
Automatic Control
Cycle time set up
ANCILLARIES
Operating and maintenance manuals
Spares list
CONTAINERISATION
incinerator fully installed inside of 10 ft ISO certified container
3,5 kwA electricity generator, 1000 litres fuel tank
Incinerator mounted on the silenblock cushion.

сжигание опасных отходов и установки для сжигания химикатов

3 типа мусоросжигательных печей: 10 кг, 20 кг и 30 кг для использования в нашей больнице Тауфик в Малинди, Кения. мы

экологическая консалтинговая компания, как я уже упоминал ранее, мы уже заключили контракт с французской компанией, специализирующейся на

продажа установок для сжигания твердых бытовых отходов (ATI) и мы купили крематорий для утилизации твердых бытовых отходов, в том числе 180 долларов США

тысяч долларов, и теперь мы хотим заняться бизнесом по продаже мусоросжигательных заводов животных, а так как у него нет

агент в Саудовской Аравии. Указанные вами три модели рассчитаны на круглосуточную работу. Не могли бы вы сделать подходящие

рекомендации по 8-10 часовой смене каждый день (включая время охлаждения)? Я предполагаю, что нам понадобятся мусоросжигательные заводы большей мощности для

каждое из трех требований. Мне интересно узнать более подробные характеристики и цены на вашу установку для сжигания отходов SYC-20. я

Я ищу небольшой и простой в эксплуатации мусоросжигательный завод, но практически не имею опыта работы с такими предметами.

монтаж и строительство ТВЕРДЫХ ОТХОДОВ
КОМПЛЕКС УПРАВЛЕНИЯ, для этого нам потребуется система сжигания мусора мощностью 16 (шестнадцать) (16) тонн (7538 кг / день). 1,5 тонны мусора.

в день,

необходимое количество единиц от -10 до 25 номеров

Установка различных типов систем управления отходами, предпочтительно сжигание и другие для штата Джамму и Кашмир Индия

производитель и экспортер различных инсинераторов и другой продукции.

Обратите внимание, что мы являемся ведущим бангладешским бизнес-домом, занимающимся различными медицинскими, хирургическими, стоматологическими и больничными услугами.

продукты, установки и машины и т. д.

Наиболее важными являются трансформатор, двигатель 220 В, термопара, вентилятор первичной горелки.

база на этом переносном мусоросжигателе,
1. Тип отходов, для которых они могут быть использованы (обработка). Установки для сжигания бытовых отходов с пониженным содержанием диоксида углерода или CIF хартом

Судан

модели инсинераторов медицинских отходов для больниц на 100-300 коек и 100-1000 коек, пожалуйста, пришлите ценовое предложение на все модели YD

и способ транзакции / доставки в Нигерию

инсинератор предназначен для использования в больнице для сжигания опасных отходов и химикатов, минимальная производительность 300 в час.

Больничная установка для сжигания медицинских отходов в соответствии с требованиями международного экологического менеджмента. Минимум 300 кг

производительность / час, Топливо, огнеупорная футеровка, дымоход и пробоотборник. Минимальная температура 1100 градусов Цельсия.

мне лучшая цена для перепродажи. Лучшая цена для перепродажи от 7000 до 12000 долларов США. У меня уже есть расценки, просто нужны

лучшая цена, пожалуйста. цена должна быть CIF Йоханнесбург или Дурбан

Para incineración, quemadores fundamentales e igualmente patológicos

Unidad principal
Aplicación Para incineración, general y patológica.
Capacidad 50-60 kg / h velocidad de combustión
Tipo Dos cámaras de combustión; tipo de aire de combustión primaria y secundaria, controlada / forzada con una unidad de lavado de emisiones de gases de combustión
Tiempo de funcionamiento Mínimo 8 horas diarias
Temperatura de funcionamiento de 850 0C a 1200 0C, control automático
Ceniza residual 5 a 10%
3.2 Cámara primaria
Construcción Construida de acero suave o aluminizado de alta resistencia O
equivalente igual y aprobado
Material de aislamiento Revestimiento de material refractario similar o igual al calcio
Combinación de silicato y cara caliente de mampostería de alta resistencia
Construcción interna Tipo de hogar fijo completo con rejillas, fondo cóncavo
y puerta de carga, revestida con material refractario
Puerta de carga Adecuada para la carga manual de residuos y con
Estimado sello equivalente a sellos cerámicos con bisagras.
Cerradura de puerta automática, tipo eléctrico
Puerta de extracción de cenizas Provista, para eliminar los restos de ceniza de fondo resultantes de la cámara principal
Rejillas provistas
Carga Carga manual de residuos
Quemador primario Totalmente automático, con controles de combustible, temperatura y velocidad con sistema de encendido, detector de llama, ventilador de aire completo con características de seguridad, falla de llama, inyector de combustible diésel y montado en brida
Ventilador incluido. Para suministrar el exceso de aire de combustión a través del sistema de distribución con sistema de control de velocidad
Temperatura Salida mínima 850 0C
Puerto de observación Se suministra con vidrio protector
3.3 Cámara secundaria
Construcción Construido de acero suave o aluminizado de alta resistencia o equivalente y aprobado
Revestimiento de material refractario de aislamiento
Temperaturas de combustión superiores a 850 ° C, controladas electrónicamente
Tiempo de retención o residuo de gas> 2 segundos a un mínimo de 850 ° C
Quemador secundario incluido, encendido por diesel, completamente automático, con control de combustible, temperatura y velocidad, con sistema de encendido, detector de llama, ventilador de aire, completo con características de seguridad, falla de llama tipo inyector de combustible encendido por diesel. Brida montada
Eyector incluido, tipo Venturi, para enfriar los gases de combustión
Ventilador de aire de combustión Proporcionado para suministrar combustión y crear una deriva negativa y turbulencias
Temperatura máxima 1600 0C
3.4 Chimenea
Construcción Construido de acero suave o aluminizado de alta resistencia o un revestimiento de material refractario equivalente equivalente y aprobado
Longitud 10 m sobre el suelo
Agujero de unos 350 mm de diámetro
Temperaturas de descarga Aproximadamente 850 0C
Emisiones Cumplir con las normas del apartado 9 del tercer anexo del reglamento de gestión de residuos de 2006.
3.5 Sistema eléctrico
Unidad de control Totalmente automático con unidad de control basada en microprocesador (PLC) que automatiza todas las operaciones del incinerador. Capaz de monitorear todos los parámetros del incinerador Con pantalla LCD grande o similar para mostrar todo el progreso
Parámetros, es decir, temperatura de las cámaras primarias y secundarias, turbulencia y tiempo
Con luz de estado
Con usuario de ciclos operativos programados definidos y diferenciados para diferentes tipos de cargas / condiciones
Con enclavamientos de seguridad, visualización de errores y alarmas visibles y sonoras.
Sistema de monitorización continua de emisiones
Interruptor de aislamiento Suministrar e instalar un interruptor de aislamiento de 240 V, 100 A para la unidad incineradora, incluidos todos los cables necesarios de 10 m
Cuadro de distribución Suministrar e instalar cuadro de distribución. 100 A, completo con MCB adecuados para la clasificación de la unidad incineradora y el equipo asociado. El cableado debe realizarse de acuerdo con la normativa IEE.
Cableado Tome las medidas necesarias para cablear el interruptor del aislador, la unidad de control del tablero de distribución al incinerador y todo el equipo asociado dentro de la sala del incinerador. Longitud de trabajo 20 m. El cableado debe realizarse con cable con revestimiento de PVC en conductos de acero y transporte por carretera y de acuerdo con las regulaciones de la IEE.
Sistema de combustible Suministre e instale el tanque de almacenamiento de combustible dentro de la sala del incinerador en una posición elevada (aproximadamente 1,5 m sobre el piso)
Tanque de combustible Capacidad del tanque, 400 litros, construido con material metálico adecuado preferible o material resistente a altas temperaturas
Tipo de combustible Diesel
Líneas de combustible Suministre e instale las líneas de combustible, completas con filtros de combustible, bomba, mirilla, nivel de combustible y todos los demás dispositivos de seguridad y conecte desde el tanque de combustible hasta el incinerador.
Longitud de trabajo, 20 m
Material de la tubería de combustible; Tuberías de cobre especiales o materiales similares y homologados
4 Características físicas
Unidad principal Montado en el suelo, independiente, tipo hogar fijo
Dimensiones Aproximadamente 1,2 x 2,2 m (WxD)
5 Entorno operativo
Requisitos de energía 240V, A / C 50Hz, monofásico, con PE
Temperatura ambiente de 10 0C a 40 0C
Humedad relativa del 40% al 90%
6. Accesorios
Rack, 2 m de largo 1 pieza
Carro de basura, acero inoxidable 1 pieza
Piezas de repuesto
Quemador 1 juego
Filtros de combustible 6 juegos
Todas las demás piezas de repuesto necesarias para su sustitución durante y después de 12 meses de funcionamiento. 2 piezas de cada
8 estándares de calidad
Normas de fabricación NEMA Kenya Act, 1999
Aviso Legal No 121 de 29 de septiembre de 1999 sobre Normativa de Gestión de Residuos
Directiva de la UE sobre incineradores de residuos – EC 76/2000
BS 3316
Estándares de emisión de la OMS
Estándares de emisiones del Banco Mundial
o cualquier otro estándar reconocido internacionalmente
Conformidad con las normas marcado CE o cualquier otro documento reconocido internacionalmente
9 Servicio de respaldo local
Disponible Debería estar disponible localmente
Capacidad para dar servicio al equipo El fabricante / agente deberá contar con instalaciones adecuadas, repuestos, personal técnico calificado y capacitado para ofrecer un servicio integral de mantenimiento y venta de repuestos durante la vida útil del incinerador
10 Punto de entrega
KEMSA para inspección y verificación
Moi Voi, Makindu
Hospitales Maragua, Barranco Eldama e Isiolo Para instalación, prueba, certificación NEMA y puesta en servicio
Trabajos de preinstalación
Proporcionar el zócalo de los cimientos, los trabajos de plomería necesarios, los trabajos de tuberías de combustible, el tanque de almacenamiento de aceite diesel elevado, los trabajos eléctricos, incluidos el cableado, los canales y los interruptores necesarios para instalar el incinerador y todos sus accesorios de acuerdo con las normas IEE requeridas.
Instalación y prueba Instalación completa y configuración del incinerador en el lugar designado según las instrucciones del fabricante.
Proporcione combustible y pruebe el incinerador durante 3 horas diarias durante 7 días
Capacitación
Capacitación del usuario Capacitación del usuario in situ sobre el funcionamiento y el mantenimiento diario
Capacitación de mantenimiento Capacitación de mantenimiento in situ sobre mantenimiento preventivo, reparación y resolución de problemas
Documentaciones técnicas
Manuales de usuario 2 juegos
Manuales de servicio 2 juegos
Dibujos 2 juegos
15 Puesta en servicio
Prueba y puesta en servicio de la máquina a satisfacción del usuario
Garantía
Equipo Mínimo un año después de la puesta en servicio de todas las piezas.
Sistema de equipamiento Nil
17. Contrato de mantenimiento
Servicio integral de reparación y prevención Se brindó un contrato de servicio integral de prevención y reparación de 12 meses que incluye repuestos y material desde la fecha de puesta en servicio

Diesel/LPG/LNG burning primary combustion chamber/primary combustion incinerator

Primary combustion
Diesel/LPG/LNG burning primary combustion chamber/primary combustion zone
Secondary combustion
Residence time in the secondary chamber not less than 2 seconds
Both primary and the secondary temperatures maintained until all the waste has been completely combusted
Chimney
Chimney with a minimum height of 4 meters above ground level
Minimum exit velocity of the emissions not less than 10 metres/second
Temperature Warnings
Audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature
General
Control box that can be detached and mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter

heightItem 1
Incinerator model A

Burn Rate 65kg/h minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time – 2 Seconds

Fuel – Diesel/LPG/LNG, please indicate

Power Supply for Control Box – 220V-240V 50Hz single phase

Minimum operating temperature 850 °C, please indicate

One year Spare Parts Package for complete maintainability

10m Hose Pipe, indicate length

I000 Litre Fuel Tank + Pipe System, indicate volume

Additional chimney extension, indicate height

Warranty, indicate no of years

Item 2
Incinerator model B

Burn Rate 150kg/h minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time – 2 Seconds

Diesel/LPG/LNG, please indicate

Power Supply for Control Box- 220V-240V 50Hz single phase
Minimum operating temperature 920 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
I000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Warranty, indicate no of years

Item 3
Incinerator model C
Burn Rate 250kg/h minimum

Weight (kg) please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box 220V-240V 50Hz single phase
Minimum operating temperature 920 °C, please indicate
One year Spare Parts Package for complete maintainability
10m Hose Pipe, indicate length
I000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Warranty, indicate no of years

High Temperature Waste Incinerator

Capacity at least (4000) kg/day ((Day=16 Working Hours))

Capacity at least (4000) kg/day ((Day=24 Working Hours))

With the following features:

*Automatic feeder as original part of the unit.

*Automatic ash / leftovers removal as original part of the unit.

*Water Injection System to control the temperature>

*Flue gas filtration system complying with EU.

*Continuous emission monitoring and recording system.

*It should include installation, testing, and staff training.

*6 nos. of heavy duty loading containers.

Item 4
HTW Incinerator model D
Burn Rate – 150kg/hour minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time 2 Seconds
Fuel Diesel/LPG/LNG, please indicate
Power Supply for Control Box 220V-240V, single phase 50-60Hz
Minimum operating temperature 1200°C, please indicate

One year Spare Parts Package for complete maintainability

10m Hose Pipe, indicate length
1000 Litre Fuel Tank + Pipe System, indicate volume
Additional chimney extension, indicate height
Mobile Incinerator

Item 5
Mobile Incinerator model E

Burn Rate 50kg/h minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time – 2 Seconds

Fuel – Diesel/LPG/LNG, please indicate

Power Supply for Control Box – 220V-240V 50Hz single phase

Minimum operating temperature 850 °C, please indicate

One year Spare Parts Package for complete maintainability
Mobile Incinerator

Item 6
Mobile Incinerator model F

Burn Rate 100kg/h minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time – 2 Seconds

Fuel – Diesel/LPG/LNG, please indicate

Power Supply for Control Box – 220V-240V 50Hz single phase

Minimum operating temperature 850 °C, please indicate

One year Spare Parts Package for complete maintainability

10m Hose Pipe, indicate length

1000 Litre Fuel Tank + Pipe System, indicate volume

Additional chimney extension, indicate height

Warranty, indicate no of years
High Temperature Waste Mobile Incinerator
Item 7
HTW Mobile Incinerator model G
Burn Rate 100kg/h minimum
Weight (kg), please indicate:
Secondary Chamber
Gas Retention Time – 2 Seconds
Fuel – Diesel/LPG/LNG, please indicate

Power Supply for Control Box – 220V-240V 50Hz single phase

Minimum operating temperature 1200 °C, please indicate
Primary combustion
Diesel/LPG/LNG burning primary combustion chamber/primary combustion zone
Secondary combustion
Residence time in the secondary chamber not less than 2 seconds
Both primary and the secondary temperatures maintained until all the waste has been completely combusted
Chimney
Chimney with a minimum height of 4 meters above ground level
Minimum exit velocity of the emissions not less than 10 metres/second
Temperature Warnings
Audible and/or visible alarm to warn the operator when the secondary temperature drops to below the required temperature
General
Control box that can be detached and mounted on separate stand at least 1.5 meters from incinerator at approximately 1.6 meter

height
Warranty, indicate no of years