Archive: May 3, 2021

Containerized Mobile Heater CA100



Incinerator Variation CA100, Summary

100Kg/Hour Burning price with Secondary burning Capability

This design is tiny medical waste incineration gadgets. Building and building is dual/double

combustion chamber with 02 units oil burner, batch load incineration equipment. Animal feed 
chamber is 560Liters (Model CA100). Primary & Secondary combustion chambers and smoke 
filter chamber with firebrick and  refractory concrete chamber. Batch load on the bottom of 
chamber. Incinerator panel control suit for local operation.

Version

CA100

Waste Treatment

Medical Waste Incineration Treatment

Feed Ability

Normal 100-200 kgs per feed

Burning Cost

Typical 100-120 kgs per human resources

Burning Time per Feed

Standard 1-2 hr

Control Mode

PLC( Programmable Reasoning Controller Incinerator)

Voltage

220V

Power

1.0 Kw

Gas

Diesel oil

Burner

Italy Heating System

Feed Setup

Manual

Temperature Screen

Digital Display

Fuel consumption (Oil)

Ordinary 20.4 Kgs/Hour

Inner Dimensions

100x80x70cm (Secret Burning Chamber)

External Capacities

230 x 130 x 155cm (main body)

Waste melting chamber

560Liters

Post Combustion Chamber

280Liters

Oil Container Capability

200 Liters

Door Opening

70 x 50cm

Smokeshaft

5.0 M

Gross Weight

4500kgs

Chamber Product

Firebrick, Refractory Concrete

Max. Heat Worth

166,000 Kcal/Hr.

Procedure Technical Specifications

Solid Chamber temperature level

8000C -10000 C

Concentration camp temperature degree

10000C -12000 C

Chamber Anti-Rate

17500C

Residency time

2.0 Sec.

Burning efficiency

> 98%

Waste Lower Calorific Power

3000Kcal

Pre-assembled, containerized type,do not included chimney installation.Burning rate: 100 – 120kg / hour.
Minimum operating temperature 800-1000 degree.Maximum operating temperature:1000-1200 degree.
Secondary Burning capacity.Density insulation.Refractory casting.Heavy duty refracting lining to 
withstand 1750 degree.Fuel type: fuel oil (diesel).


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


pet incinerator

The incinerator plant shall incorporate a control panel for its operation. On the control panel we shall have a visual

display of the chamber temperatures. This visual display must control and monitor the incinerator and his performance.

Capacity of destruction in weight shall be 60 Kg/h.

It should be able to operate not less than 10 hours/day

This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories,

institutes, etc…

Design Specification : Types A, B, C, D, and E of medical waste

Supply, installation & testing DUCTED SPLIT UNITS at waste store with sufficient capacity to maintain the internal

temperature at 14 degrees Celsius in summers and winters

100-150kgs Burning cost with Second burning to be usage in the health center



Oil tank with 2000Liters capacity

Items/Model

TS150( PLC)

Image

Principle

Waste Incineration Therapy

Burn Rate

Requirement 100-150 kg/hour

Feed Ability

Standard 750kg/feeding

Control Setting

PLC( Programmable Thinking Controller Burner)

Text Steel

8mm thickness

Chamber Product

High Alumina Fire Brick Wall Surface, 1750 ℃ Rate

Paint for outside face

800 ° C Rate

Combustion Chamber

1570L

Interior Measurements

150x100x105cm

Added Chamber

750L

Smoke Filter Chamber

Yes

Feed Establishing

Guidebook

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Intake (Liter/hour)

Normal 14( D.O)

Gas Consumption (m3/hour)

***

Temperature Level Show

Digital Present

Temperature Protection

Yes

Oil Storage Tank

300L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless-steel

1st. Chamber Temperature Degree

800 ℃–– – – -1000 ℃

second. Chamber Temperature Level Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Outside Measurements

300x160x280cm( without smokeshaft)


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


small scale medical incinerator

The burners shall comply with the requirements of BS 799 or DIN Standards. Each shall be the packed type and

incorporate automatic stop/start programmed timer control, flame failure equipment and ignition failure equipment to

close off the fuel supply in the event of malfunction.

 

  1. Each burner shall be designed and mounted for ease of access and so that they may be fully maintained from

outside the combustion chamber. The burners shall be mounted so that waste cannot block the flame ports.

SL No   Description   Fill up the bidder

Lot-A Specification

1     Hydroclave for Medical waste Treatment Plant

 

General Requirements

  • The processor must be approved to sterilize & treat the following types of medical waste:

—   Liquids: Blood, body fluids etc.

—   Blood bags & tubing, gloves, Gowns, drapes, etc.

—   Contaminated packaging: bandage etc

—   Sharps & Sharp containers

—   Disposable instruments

—   Glass products

— Human and animal tissue (surgical and pathologic)- Based upon MWM regulations.

— Cultures, stocks and glassware

 

*  The processor must comply with a documented efficacy level of 6 log10 reduction in spore survival (99,9999%) of the

Bacillus Stearothermophilus

* The processor should reduce the volume of the waste by 60% to 80% through complete dehydration and sterilization of

the waste

* The processor must have ZERO harmful emission level and meet or exceed all standards required by the EU.

 

The whole waste treatment system should be offered as a complete unit consisting of following equipment and

ancillaries-

(A) The sterilization processing unit

(B) Steam Boiler

(C) Tub washer

(D) Heavy duty external shredder

(E) Conveyer belt — based on Manufacturer’s Recommendations

(F) Bin Lift/Tipper

(G) Spore tester

 

 

(A) Features and Specifications of the Sterilization Processor unit:

Technical specification of the processor.

*  Steam autoclave in combination with a heavy duty Fragmenting System inside the vessel/ chamber

*  The vessel must be of Double Chamber

* Capacity (kg/load): minimum 2001cg/batch/cycle

*  Volume of 140-190 liters of bulk per cycle

*  Average Cycle time: 60 minutes

*  Operating temperature : 121°C to 135°C

*  Operating pressure: 1.1 Bar to 2.4 Bar

* Sterilization time : approx. 30 minutes at 121°C/1.1 Bar or approx 15 minutes at 132°C/2.5 Bar to achieve 6log10

sterility

* Fragmentation inside the chamber: Heavy duty with maximum size of final product <20 cm.

*  Volume reduction of the waste after processing : by 60-80% through complete waste dehydration including liquid

content of the waste

*  All actions after loading for sterilization, fragmentation of product is to be occurred in the same chamber/vessel

*  Pre or Post-air evacuation should not be necessary or used

*  Exhaust air quality: Does not require any venting for odor control

* Operating System: Fully automated with manual over-ride. (On board PLC capable of generating written report with

cycle time, cumulated time at > 121°C

* The option should be there for Internet connectivity by phone, cable or

* Boiler: should not require pre-heated water

* Electrical requirements: 220Vac, 1ph or 400vac 3ph to suit customer needs

* Noise level at full operation: < 80 dB

Working Principle of the processor:

*  The processor should utilize steam technology in conjunction With a mechanical fragmentor (grinder) to sterilize

medical waste, thereby  making the  residual waste safe for disposal in landfills.

*  The sterilization vessel MUST be a double walled (jacketed) cylindrical vessel

* Pre-shredding of infectious waste must not be accepted, the fragmentation must occur safety inside the scaled vessel

continuously.

* The sterilization vessel/chamber must be fitted with a motor driven shaft to which a heavy duty grinder(fragmenting

arm)  is attached inside the vessel to produce all unrecognizable size of the waste product.

* The Fragmenting are must rotate to agitate waste continuously throughout the heating and sterilization cycle to

ensure that the fragmented q agitated wastes (including sharps and liquids) are exposed evenly to sterilization

temperature and pressure.

* Steam heat should be applied to the jacket only, while the agitated waste absorbs the heat from the jacket and makes

its own steam from its moisture content.

* Should not need for special autoclave bags — simple bag or box should be workable

* MUST not need for hi c-treatment of the waste.

* Liquids and gases MUST remain locked inside the vessel until sterilization is complete – nothing should be vacuumed

or pumped out in its infected state.

* Jacket steals heat to dehydrate the waste completely regardless of its original water content.

* All the hot condensate from the jacket is recycled, making the processor very economical to operate

Burning ability 50kg/hr with damp scrubber with dual released heater



This model is small-scale waste incineration equipment for small waste output. 
Construction is dual/double combustion chamber with 02 units oil/gas burner. 
Waste feed chamber is around 900Liters (0.9m3, YD-50). Primary & Secondary 
combustion chambers and included mix-combustion chamber. Waste load on the 
bottom of chamber. Incinerator panel control suit for local operation.

Design

YD-50 with wet scrubber

Photo

Burning Cost

Ordinary 50 kgs/hour

Feed Ability

Typical 100 kgs

Main Combustion Chamber

900 Liters

Secondary Burning Chamber

200 Litres

Mix Burning Chamber

Yes

Smoke Filter Chamber

Damp Scrubber( Laundering Tower)

Feed Establishing

Manual

Voltage

220V

Power

7 Kw

Gas Kind

Diesel Oil/ All-natural Gas/LPG

Heater

Italy Original

Oil Use (Diesel Oil)

16.9 kg/hour

Gas Consumption (Gas)

***

Internal Measurements

120x90x85cm (vital chamber)

Outside Measurements

400x200x230cm (without smokeshaft)

Temperature Level Degree Screen

Yes

Oil Container Ability( if oil gas)

300 Litres

Door Opening

62 x 68cm

Chimney Size

5.0 Meters

Smokeshaft Type

Stainless Steel

Equipment Gross Weight

6000 kgs

Treatment Technical Specifications

Main Chamber Temperature

800 ℃–– – – -1000 ℃

Extra Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98%

Waste Lower Calorific Power

3000Kcal



 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


Pet crematorium as high as 200KG/day



Animal Crematory Burner

Ability: Normal 80kgs per feeding



Thing

Spec

Layout

A900

Interior Measurements

120 x 90 x 85 CM

Match for Family Pet

Feline – – – – yes

– Family pet – yes

Pig – – small

Cow – – no

Key Product Checklist

Key Burning Chamber

Additional Burning Chamber

Mix-Combustion Chamber

Smoke Filter Chamber

Burner Control Instance

Smokeshaft:5.0 Meters

*( upgrade to Stainless-steel, free cost)

Italy oil/gas burner: 03 collections

Oil Container (if oil gas): 500Liters

















Design

A900

Image

Burning Cost

Common 30 kgs/hour

Feed Capacity

Ordinary 80 kgs/feeding

Trick Combustion Chamber

900 Litres

Second Burning Chamber

300 Litres

Mix Burning Chamber

Yes

Smoke Filter Chamber

Yes

Feed Establishing

Manual

Voltage

220V/380V

Power

1.5 Kw

Fuel Type

Diesel Oil/ All-natural Gas/LPG

Burner

Italy Original

Oil Consumption (Diesel Oil)

Normal 34 kg/hour

Gas Intake (Natural Gas)

Normal 41 m3/hour

Interior Measurements

120 x 90 x 85 centimeters (key chamber)

Outside Dimensions

200 x 160 x 310 centimeters (without chimney)

Temperature Display

Yes

Oil Container Capability( if oil gas)

500 Litres

Door Opening

60 x 80cm

Chimney Size

5.0 Meters

Smokeshaft Kind

Stainless-steel

Combustion Chamber Product

Refractory Concrete Cement( No Block)

Instruments Gross Weight

6000 kgs

Treatment Technical Specs

Main Chamber Temperature Level Degree

800 ℃–– – – -1000 ℃

Added Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98%

Waste Lower Calorific Power

3000Kcal



 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


Family Pet Crematory with Movable system & & & & Auto. Door & & Independent Placement



Incinerator Model A1500, Intro

This design is big-scale pet cremation tools for huge pets.

Construction is dual/double combustion chamber with 03 units oil/gas burner, 
batch load incineration equipment. Animal feed chamber is 1500Liters (Model: A1500). 
Primary & Secondary combustion chambers and included mix-combustion chamber, 
smoke filter chamber with firebrick and Refractory Concrete chamber. Batch load on 
the bottom of chamber. Incinerator panel control suit for local operation.

Model

A1500

Burning Rate

Average 50 kgs/hour

Feed Capability

Ordinary 150 kgs

Key Combustion Chamber

1500 Liters

Extra Burning Chamber

500 Litres

Mix Combustion Chamber

Yes

Smoke Filter Chamber

Yes

Feed Setting

Hand-operated

Voltage

220V/380V

Gas Kind

Diesel Oil/ All-natural Gas/LPG

Heater

Italy Original

Oil Consumption (Diesel Oil)

Normal 34 kg/hour

Gas Consumption (Gas)

Common 41 m3n/hour

Inner Measurements

150 x 100 x 96cm (key chamber)

Outdoors Measurements

240 x 170 x 380cm (without chimney)

Temperature Monitor

Yes

Oil Container Capability( if oil gas)

300 Litres

Door Opening

59 x 81cm

Smokeshaft Length

10.0 Meters

Smokeshaft Type

Stainless-steel

Tools Gross Weight

7500 kgs

Operation Technical Specifications

Main Chamber Temperature

800 ℃–– – – -1000 ℃

Second Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98%

Waste Lower Calorific Power

3000Kcal


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


Common 10kgs per human resources burner for small health care facility



This equipment quality structural for kinds of site, like hospital, environmental department, 
animal cremation agencies, etc. 
HICLOVER Incinerator supply updated models with dual combustion chamber, 
mix-combustion chamber and smoke filter 
chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.

Tools Technical Specifications

Version

YD-10C

Image

Feed Capability

Common 40 kgs per feed

Burning Price

Typical 10 kgs per hour

Burning Time per Feed

3.0 -5.0 hrs

Voltage

220V

Power

0.50 Kw

Gas

Natural Gas or Diesel oil

Heating unit

Italy Heating Unit

Feed Mode

Guidebook

Gas use (Oil)

4.4-9.4 Kgs/Hour

Gas intake (Gas)

5.3-11.2 m3/Hour

Outdoors Measurements

170 x 140 x 160cm (mainbody)

Inside Measurements

55 x 55 x 65cm( Trick Chamber)

Waste burning chamber

200Liters

Write-up Combustion Chamber

140Liters

Oil Container Capability

50 Litres

Door Opening

38 x 48cm

Chimney

5.0 M

Gross Weight

1800kgs

Chamber Product

Refractory Concrete

Max.

Operation Technical Specs

Solid Chamber temperature degree

8000C -10000 C

Gas Chamber temperature level

10000C -12000 C

13500C

Chamber Anti-Rate

2.0 Sec.

Residency time

2.0 Sec.

Burning efficiency

> 98%

Waste Lower Calorific Power

3000Kcal


































 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.


medical waste furnace

The incinerator to be fully assembled wired and logic function tested in the factory, prior to dispatch.

 

–      One high flue gas temperature indicator/alarm to provide an audio/visual warning in the event of high flue gas

temperatures occurring in two stages:-

 

First stage audible alarm, second stage incinerator shutdown, with one voltage free contact for connection to a

remote alarm system.

 

–      Flexible wire control linkages to bring under fire air, overfire air and burner slide plate control to front of

incinerator.

 

–      One fire protection system, comprising fusible links over burners, deadweight fire valve, electrically

interlocked with incinerator controls.

 

–      Special feeding door with thermal lock to protect the operator from accident.

 

2.2  PRIMARY CHAMBER

 

  1. The chamber shall consists of a welded steel shell of minimum 6mm thickness plate reinforcing strips and

connections for primary air supply, start-up burner, thermal reactor, water injection and all necessary measuring probe

sockets.

 

  1. The entire chamber, including all the connections shall be lined with a composition of castable hot face

refractory suitable for a continuous service temperature of 1500 deg. C. This lining shall be separated from the steel

construction by a second layer of insulation. Heat resistant cast steel plates with many fine holes shall be lied over

the refractory lined floor of the unit with a space between the two.

 

  1. The chamber shall be externally primed and sprayed with a silicone enamel paint.

 

2.3  THERMAL REACTOR

 

  1. The reactor shall consist of welded cylindrical steel sections of minimum 9.5mm thickness plate.

 

  1. The whole chamber shall internally be constructed with a refractory lining.

 

  1. The chamber shall be provided with connection for the low temperature carbonization gas intake, the flue gas

outlet, the secondary and tertiary air supply, the reactor burner and all the required measuring probes.

 

  1. Externally the reactor shall be primed and sprayed with a silicone enamel paint.

incinerator manufacturer

“PYROLYTIC” combustion, by controlling the gasification of waste

The incinerator manufacturer must avoid the release of black smoke and fine dust, during the loadings.

It shall be able to reduce the volume of wastes by 98%.

It shall be able to hold emission in the second burn with gas residence of not less than 2 seconds.

 

The incineration should be completely free from visible smoke as well as offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

The primary combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a

complete layer of hote face refractory and high efficiency insulation.

The Internal diameter of the Chimney at least: ? 400 and its height: 8 m