Archive: May 6, 2021

medical incinerators

● Able to burn 25-30kg per hour
● Consist of two chambers to ensure significant reduction in emission
● Be capable of temperature in range of 800c to 1000c
● Low maintenance design
● Must be Diesel fuelled
● Need more than 15amp 220- 250V power
● kW Consumption power consumption to be stated
● Onboard or in-built fuel storage storage tank & should use no more than 12L of dies el per hour to burn 25-30kg of waste
● Solid waste reduction in range of 90-97% ( should be routinely achieved)
·         General wastes produced on a daily basis  include paper, plastic, organic materials, boxes, plastic containers, leaves, etc;

·         Total waste produced per day: 10-12 tonnes;

·         Hours of Operation: 10 hours a day;

·         Fuel requirement: Diesel or waste oil preferred but LP gas will be considered;
Fuel options    Oil
Fuel consumption (diesel)    10 litre/hour
Average Capacity    900kg
Diamention: Length (mm)
Width (mm)
Height Excl. Flue (mm)
Door Opening (mm)    2570
1120
1340
1000×1670
Internal Chamber Dimen:
Length (mm)
Width (mm)
Height Incl Flue (mm)
2200
790
790
Operation:
Min. Operation Temprature
Max. Operation Temprature
Residence Time in Second Chamber
Temprature Monitoring
950
1320

2 sec.
YES
Key Features
-Auto ignition
-Automatic control and temprature
-Upto 250 kg per hour
-Thick refratory lining rated to 1600 deg C in main chamber retain heat, increase efficiency
-Heat resistant 5 mm steel
-Stainless steel stack
-12 cm of refractory lining- steel reinforced.
-12 month or 1000 hours waranty
-Heat recovery system
-Wide door for ash removal
-Large top opening lid for easy loading

Incinerator Components Mineral Insulated Thermo pair sensor K-Type 300SS



Incinerator Parts Mineral Insulated Thermo couple sensor K-Type 300SS
K type 300SS: M27*2, 300mm Ins,2520 S.S, 2.5mm core 

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27



laboratory incinerator

the entire carcass of animals ( cattle , horses ,
Sheep, pigs , etc.) , as well as biologically hazardous waste
Products in the fuel stove .
? Opening Doors – the closure and fixation automated system ,
Which are managed remotely by the operator .
? designed to work in long mode and fast
Action ( Quick Start EP – i)
? Fully mobile – mounted on wheeled chassis
Even during the operation . Incinerators must be provided
As standard equipment a special truck

air retention for at least 2 seconds at a temperature of less than 850C, the combustion
In order to achieve the proper effect.
? must be a two-chamber incinerators, primary and secondary
Fuel stoves
? The waste products to reduce the initial volume
Possible to minimize (approximately 5% sterile ash
Form).

Incinerators should be provided in the fuel tank (diesel )
? The minimum capacity of the animal carcass incinerator
The destruction of 1000 kg / hour. Incinerator capacity is calculated
8MJ/kg- material and 60 % humidity.
? It must be possible to use the incinerator +40
C to – 15 0C laboratory incinerator
Temperature and 5% – 95% – of moisture conditions.
? PLC controller and a built-in temperature panelita complete
Automatic control, a control computer, which is stored
Information on the variation of temperature with respect to time and
Graphic images.
? must have fuel with automatic control and malfunction
Detection system.
?the ability to pre- warm-up , body waste burning on and off
Consistency is independent of the first and secondary chambers.
? ensuring the incinerator with electricity , it
Must be installed on the generator.
? clean the incinerator should be simple tools ,
Without using any additional equipment

General requirements of a 100 kg/hr 3 burning Chambers Burner



General specifications of a 100 kg/hr incinerator
No. Description Parameter value  
  model   HICLOVER YD100
1 Machine working mode Oil + Power Oil + Power
2 Voltage 220V C 3 phase or 1 phase 220V 1P
3 Oil consumption (lit/hr) Average 25-32 lit/hr/chamber Average 33Liters/hour/total incinerator 3 burners
6 Incineration rate 100 kg/hr = 400-600 kg/8hr average 100kgs per hour
7 Feed mode Manual manual
8 Primary combustion rate 1000 lit 1080 liters
9 Secondary combustion rate 240 lit 207 Liters
10 Tertiary combustion rate 416 lit 452 liters
11 Combustion chamber material High temp. resistant concrete High temp. resistant concrete
12 Internal dimensions (1st chamber) 100*100*100 cm (l*w*h) = 1000 lit 120*100*90cm(l*w*h) = 1080 lit
13 Internal dimensions (2nd  chamber) 40*40*150 cm = 240 lit Diameter 42*150cm=207 Liters
14 Internal dimensions (3rd  chamber) 40*40*260 cm = 416 lit Diameter 60*160cm=452 Liters
15 External dimensions 300*155*200 cm (l*w*h) 220*160*370 cm (l*w*h)
16 Door opening 90*90 cm 90*90 cm
17 Additional air fan 1 fan (on the door) 1 fan (on the door)
18 Fuel type Diesel oil/ Diesel oil
19 Burner Brand: Radiator or Hofmat Italy Baltur
20 Chimney length 3-4 meters 5 Meters
21 Chimney type and material H-type stainless steel, or High temp. resistant concrete 1 Meter High temp. resistant concrete +4 Meter Stainless steel
22 Smoke and smell filter Yes, two stages. Dry Scrubber 2 stages
23 Temperature monitor Yes, (for 1st and 3rd chambers) Yes, (all 3 chambers)
24 Temperature control Optional yes
25 Oil tank 500 lit needed. yes
26 Burning efficiency >98% yes
27 1st chamber temperature 300-700 oC 800-1000 oC
28 2nd chamber temperature 500-1000 oC 1000-1200 oC
29 3rd chamber temperature 800-1200 oC 1000-1300 oC
30 Smoke residency time >2 sec. >2 sec.
31 Gross weight 5-8 tons average 6.5 Ton
32 No. of Burners 3 3


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27



DIESEL ENDED BURNER, WITH 1000 LTR GAS STORAGE TANK As Well As 6M SMOKESHAFT



Items/Model

TS250( PLC)

Photo

Idea

Waste Incineration Treatment

Burn Price

Average 250 kg/hour

Feed Ability

Criterion 400kg/feeding

Control Establishing

PLC( Programmable Reasoning Controller Burner)

Combustion Chamber

2000L

Inner Measurements

210x88x110cm

Second Chamber

1000L

Smoke Filter Chamber

Yes

Feed Setting

Guidebook

Voltage

220V

Power

2.0 Kw

Oil Consumption (kg/hour)

Regular 24.2( DO)

Gas Consumption (m3/hour)

***

Temperature Display

Digital Present

Temperature Level Protection

Yes

Oil Tank

1000L

Feed Door

2.04 x 1.06 M

Smokeshaft

3Meter

Chimney Kind

Stainless-steel

1st.

Gross Weight

9000kg

Exterior Measurements

3.00 mx1.60 mx3.00 m (without chimney)

TWO (2) YEAR UPKEEP SPARES STRATEGY FOR LINE THING 2 X OIL DISCHARGED HEATING SYSTEM

2 X CONCRETE REPAIRING BUNDLE (25KG)

2 X THERMOCOUPLE

2 X FIRE ROPE (1M)

2 X HT MASTIC (PER BURNER)

INCINERATION IS A WASTE TREATMENT PROCESS THAT INVOLVES THE COMBUSTION OF ORGANIC SUBSTANCES CONTAINED IN WASTE MATERIALS. INCINERATION AND OTHER HIGH-TEMPERATURE WASTE TREATMENT SYSTEMS ARE DESCRIBED AS “THERMAL TREATMENT”. INCINERATION OF WASTE MATERIALS CONVERTS THE WASTE INTO ASH, FLUE GAS AND HEAT. THE ASH IS MOSTLY FORMED BY THE INORGANIC CONSTITUENTS OF THE WASTE AND MAY TAKE THE FORM OF SOLID LUMPS OR POWDER.

1 X PPE BUNDLE

2020-06-27

2 X FIRE ROPE (1M)

2 X HT MASTIC (PER INCINERATOR)

1 X PPE PACKAGE


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27



Incinerator with 1 or 3 area kind moist scrubber



Medical waste is currently managed via an old medical waste incinerator; which also manages the associated medical waste delivery and ash removal arrangements.Pathological waste: organs, tissues, surgical specimens, bodily fluids removed during surgery or autopsy.  Mix and moisture content not known.Allow for weekly deliveries @ 8 hour per day operation = 11 kg per hour capacity.

Layout

YD-150

Image

Burning Rate

Normal 150 kgs/hour

Feed Capacity

Standard 300 kgs/feeding

Secret Burning Chamber

1500 Liters

Added Burning Chamber

500 Litres

Mix Burning Chamber

Yes

Smoke Filter Chamber

Damp Scrubber System( 3 Location Kind)

Feed Setting

Manual

Voltage

380V

Power

9.0 Kw

Gas Kind

Diesel Oil/ All-natural Gas/LPG

Burner

Italy Original

Oil Usage (Diesel Oil)

Ordinary 24 kg/hour

Gas Intake (Gas)

***

Inner Measurements

150 x 100 x 96cm (primary chamber)

Exterior Dimensions

240 x 170 x 380cm( without chimney/wet scrubber)

Temperature Monitor

Yes

Oil Container Ability( if oil gas)

300 Litres

Door Opening

59 x 81cm

Chimney Size

10.0 Meters

Chimney Kind

Stainless-steel

Equipment Gross Weight

11000 kgs

Treatment Technical Specifications

Main Chamber Temperature Degree

800 ℃–– – – -1000 ℃

2nd Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Performance

> 98%

Waste Lower Calorific Power

3000Kcal

HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27



Mobile Containerized Waste Incinerators HICLOVER CA-200



Mobile Containerized Waste Incinerators pets or human cremation emergency use



Layout

CA-200

Photo

Burning Rate

Common 100 kgs/hour

Key Burning Chamber

2000 Liters

Secondly Burning Smokeshaft

Yes

Feed Establishing

Hand-operated

Voltage

220V

Power

3.0 Kw

Gas Kind

Diesel Oil

Heater

Italy Original

Oil Usage (Diesel Oil)

Typical 53 kg/hour

Interior Measurements

200 x 100 x 100cm (main chamber)

Outside Measurements

290 x 200 x 170cm (key chamber)

Temperature Degree Screen

Yes

Oil Storage Tank Capacity( if oil gas)

500 Liters

Door Opening

90 x 90cm

Smokeshaft Size

5.0 Meters

Chimney Kind

Stainless-steel

Tools Gross Weight

9000 kgs( with container)

Procedure Technical Specs

Paimary Chamber Temperature

800 ℃–– – – 1000 ℃

Additional Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Efficiency

> 98%

Waste Lower Calorific Power

3000Kcal


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-27



Waste Incineration Treatment BURNING COST: 100-150kgs per human resources HICLOVER TS150



BURNING RATE: -100 -150 kgs per hr

MINIMUM OPERATING TEMPERATURE: 800-1000 oC (PRIMARY BURNING)

MAX OPERATING TEMPERATURE LEVEL LEVEL: 1000-1200 oC (AFTER HEATING UNIT BURNING)

SECONDARY MELTING ABILITY: COMPULSORY

THICKNESS INSULATION: 50 mm high

Refractory ability: mins 114mm

STURDY REFRACTING LINING TO WITHSATND 17500C

AVEARGE WEAR OUT TIME: MAXIMUM 3HRS

GAS KIND: GAS OIL (DIESEL)

GAS CONSUMPTION IN LTRS/HR: average 14

RESIDNECY TIME IN SECONDARY CHAMBER: 2 PHASES

Items/Model

TS150( PLC)

Image

Idea

Waste Incineration Therapy

Melt Cost

Criterion 100-150 kg/hour

Feed Capability

Standard 750kg/feeding

Control Setting

PLC( Programmable Reasoning Controller Burner)

Chamber Product

High Alumina Fire Block Wall Surface, 1750 ℃ Rate

Paint for outdoors deal with

800 ° C Cost

Burning Chamber

1570L

Inner Measurements

150x100x105cm

Additional Chamber

750L

Smoke Filter Chamber

Yes

Feed Setting

Guidebook

Voltage

210/230V 50/60Hz

Power

0.9 Kw

Oil Consumption (Liter/hour)

Common 14( D.O)

Gas Consumption (m3/hour)

***

Temperature Screen

Digital Show

Temperature Level Protection

Yes

Oil Storage Tank

2000L

Feed Door

80x60cm

Smokeshaft

10Meter

Smokeshaft Kind

Stainless Steel

1st. Chamber Temperature

800 ℃–– – – -1000 ℃

secondly. Chamber Temperature Level Degree

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

8500kg

Exterior Dimensions

300x160x280cm( without chimney)



HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28



medical incinerator manufacturer

1.The double chamber incinerator shall preferably be designed. Air supply in the primary and secondary chamber shall be regulated between 30%-80% and 170%-120% of stoichiometric amount respectively. Flow meter/suitable flow measurement device shall be provided on the primary and secondary air ducting. The combustion air shall be supplied through a separate forced draft fan accounting for the air supplied through burners. Provision shall be made in the primary chamber to measure the water column pressure.
2. Capacity : up to 4000kg      burn not less than 500 kg /hr
3. medical incinerator manufacturer The refractory lining of the chamber shall be strong enough to sustain minimum temperature of 1000dc in the primary chamber and 1200 dc in the secondary chamber. The refractory& insulation bricks shall have minimum 115mm thickness each & conform to IS:8-1983 & IS:2042-1972 respectively.
4. The incinerator shell shall be made of SS/MS plate of adequate thickness (minimum 5mm) and painted externally with heat resistant aluminium paint suitable to withstand temp.of 250 dc with proper surface preparation. Refractory lining of the hot duct shall be done with refractory castable (minimum 45mm thick)& insulation castable(minimum 80mm thick). Ceramic wool shall be used at hot duct flanges & expansion joints.
5.There shall be a separate burner each for the primary & secondary chamber. The heat input capacity of each burner shall be sufficient to raise the temp.in the primary & secondary chambers as 800+/- 50dc and 1050+/-50dc respectively within maximum of 60 minutes prior to waste charging. The burners shall have automatic switching off/on control to avoid the fluctuations of temperatures beyond the required temp.range.
6.Incinerator shall have graphic or computer recording device which shall automatically and continuously monitor and record dates, time of day, batch sequential number,Co,Co2,O2 in gaseous emission shall also be  measured daily.
7. Structural design of the chimney/stack shall be as per IS:6533-1989.The chimney/stack shall be lined from inside with minimum of 3mm thick natural hard rubber suitable for the duty conditions and shall also conform to IS:4682 part I-1968 to avoid corrosion to oxygen and acids in the flue gas.

8.The incinerator must have an emergency vent. The emergency vent shall remain closed ie. it shall not emit flue gaseous during normal operation of the incinerator.

9.Metal fuel tank from black steel (capacity not less than 2500 litres) and shall be installed at the incinerator Room. The tank shall be provided with all necessary fittings including fill, vent, drain and overflow line, level indication and access for inspection and maintenance. Level switches shall be provided for the following services.

(a) Low level alarm
(b) High level alarm
(c) Low level start of transfer pump
(d) High level stop of transfer pump

10.A ready built fabricated room shall be supplied for housing the incinerator. The room will be designed in such a way that free space is  available  on all sides and heat radiation  kept at minimum and giving the operators an easy workable environment and ventilation. The materials will be sufficient structural thickness of mild steel angles neatly coated with metal primer and epoxy paint to withstand sea corrosion
– effectiveness for the treatment of placenta? and expired or spoiled drugs, cytotoxic and cytostatic drugs prescribed: narcotics eg
– Does it allow to treat drug or waste containing glass (whatever color: transparent or colored white) without causing explosions?
– The ability of the liquid waste treatment (blood, urine stained, other body fluids contaminated, regardless what volume packaging?
– The efficiency of process chemicals (after neutralization and detoxification: solids and liquids)
– Is there  microbiological testing especially: the processing efficiency bascillus

HICLOVER Heater mobile little With Wheel along with Brake



Version

YD-30 Mobile Kind

Picture

Burning Price

Ordinary 30 kgs/hour

Feed Capacity

Common 60 kgs/feeding

Chamber Text

Stainless-steel

Mobile Attribute

With Wheel and likewise Brake

Main Burning Chamber

280 Liters

Second Combustion Chamber

150 Litres

Mix Burning Chamber

Yes

Feed Setting

Handbook

Voltage

220V

Power

1.5 Kw

Gas Kind

Diesel Oil

Burner

Italy Original

Oil Consumption (Diesel Oil)

Criterion 13.3 kg/hour

Internal Measurements

80 x 60 x 60cm (major chamber)

Outside Capacities

125 x 90 x 260cm (without smokeshaft)

Temperature Level Degree Present

Yes

Oil Container Capacity( if oil fuel)

100 Litres

Door Opening

50 x 50cm

Smokeshaft Size

2.0 Meters

Chimney Type

Stainless-steel

Equipment Gross Weight

1600 kgs

Operation Technical Specifications

Key Chamber Temperature

800 ℃–– – – -1000 ℃

Additional Chamber Temperature

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Burning Effectiveness

> 98%

Waste Lower Calorific Power

3000Kcal


HICLOVER – Medical Environmental 


 
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

2020-06-28