Hot sale small waste incinerators 30kgs and 50kgs per hour”

ts30

Items/Model TS30(PLC) TS50(PLC)
Burn Rate 30 kg/hour 50 kg/hour
Feed Capacity 60kg 100kg
Control Mode PLC PLC
Combustion Chamber 330L 560L
Internal Dimensions 75x75x60cm 100x80x70cm
Secondary Chamber 180L 280L
Smoke Filter Chamber Yes Yes
Feed Mode Manual Manual
Voltage 220V 220V
Power 0.5Kw 0.7Kw
Oil Consumption (kg/hour) 10.2–20 12.1–24
Gas Consumption (m3/hour) 9.8–20 9.9–26.1
Temperature Monitor Yes Yes
Temperature Protection Yes Yes
Oil Tank 100L 100L
Feed Door 55x50cm 70x55cm
Chimney 5Meter 5Meter
Chimney Type Stainless Steel Stainless Steel
1st. Chamber Temperature 800℃–1000℃ 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃ 1000℃-1200℃
Residency Time 2.0 Sec. 2.0 Sec.
Gross Weight 3000kg 4500kg
External Dimensions 175x120x140cm 230x130x155cm

Oil fired incinerator,Medical Waste Incinerator”

Medical Waste Incinerator

 

Items/Model TS100(PLC)
Burn Rate Average 100 kg/hour
Feed Capacity Average 200 kg/feed
Control Mode PLC
Combustion Chamber 1200L
Internal Dimensions 120x100x100cm
Secondary Chamber 600L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 14–28
Gas Consumption (m3/hour) 10–32.2
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 200L
Feed Door 80x60cm
Chimney 10Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800℃–1000℃
2nd. Chamber Temperature 1000℃-1200℃
Residency Time 2.0 Sec.
Gross Weight 6000kg
External Dimensions 260x150x180cm

incinerator, medical incinerator, small incinerator,waste incinerators”

Nanjing Clover Medical Technology Co., Ltd.  is a leading waste incinerator manufacturer in China. We are local  manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. to 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world.

Key Features:
* All models with Dual combustion chamber.
* Stainless Steel chimney/stack, long lifetime. *according to order
* High temperature, long lifetime of incinerator.
* Free or minimum installation on site.
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.
* PLC Control Plane.*according to order
* New Design for pet animal cremation business.
* One year warranty on incinerator and parts in stock.

Application Scope:
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.
3. Community & Sea Port & Station: Municipal Solid Waste, etc.
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

clinical waste burner



Australian burning style exclusive 5 25kg/hour
double chamber( LPG) burner or equal approved. burner
casing to be light steel with 125mm refractory lining containing
essential and second chamber, protected draft area above
second chamber, bundle burners, electronic temperature level control
systems, ash rake as well as poke, 2nd door in main chamber,
hands-on filling chute, semi automated operated counter well balanced
packing door with packing tray complete with stainless-steel flue
recommended extra components.



medical was incinerators Department of Wellness



university hospital waste administration group at a tertiary care health center,1250 beeded hsopital.

our everyday waste developed from all sources is 0.55 kg/bed/day =685kg/day

we require an incinerator of 150kg/hour filling up capacity.

plz reply with, acquiring, installment, running along with upkeep cost.incinerators, particularly, clinical was heaters
The specification of the Heater is as detailed below:

Needs of Heater

1. Need to have prep work, Incineration, Scrubber actions to thaw waste totally as well as likewise waste gas need to be non-polluted

2. Ash must be just 5% of the waste material

5.

our day-to-day waste created from all resources is 0.55 kg/bed/day =685kg/day

we need a burner of 150kg/hour filling up ability. The specification of the Heater is as listed below:

Requirements of Burner

1. Should have preparation, Incineration, Scrubber actions to thaw waste completely and additionally waste gas require to be non-polluted

2.

9. 1 year service warranty

10. ISO Licensed

11. Mobile Burner

12. Electric



Medical Waste treatment system



Medical Waste therapy system

The medical waste therapy system will certainly be environmentally-friendly, as well as have a capability of
relating to 200-300kg per set, to allow therapy of medical waste developed in a 160-bed
medical center
If, the equipment requires to be self-steam creating
vapor is needed for the sanitation treatment.
– Steel things. – Pathological waste.
– Compact the waste to reduce its amount
Unloading of cured waste will certainly be automatic, with even more shredding center
All running attributes will certainly be risk-free, automated
1. The whole cycle will certainly be computerized with all important operating requirements secured as well as likewise
password protected.
2. There will be a files characteristic of the treatment cycle,
The device shall have a hands-on mode of operation in instance of stopping working of the automatic attributes
The adhering to criteria will certainly be presented:
1. Power on
2. sterilization indication light
3. auto/manual switch
4. open door warning light
5. vapor pressure
6. cycle chart recorder