Archive: May 28, 2021

Controlled air medical waste incinerator designed for incineration of bio-medical waste

Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc. )

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required

Standards
1) Bidder or Manufacturer ISO 9001 Certified
2) Respecting international emission standards
Electrical characteristics
3) A 230V, 60Hz single-phase electrical source.
4) Protections against over-voltage and over-current line conditions.
5) Compliance with applicable Ghanaian standards and regulations.
Operational characteristics
6) Two-stage incineration with dual chamber combustion
7) Burn rate: 15 – 20 Kg/h
8) Capacity: not less than 130 L
9) Concentrations of most pollutants in stack gases below detection limits
10) Diesel fuel
11) Electronic system control
12) Easy to operate and minimal training
13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included
PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Incinérateur de déchets médicaux à air contrôlé conçu pour l'incinération des déchets biomédicaux

Incinérateur de déchets médicaux à air contrôlé conçu pour l’incinération des déchets biomédicaux générés dans un centre de traitement du sang. Les déchets à traiter comprennent principalement les biodéchets (c’est-à-dire les fluides corporels), les déchets infectieux et dangereux tels que les seringues, les aiguilles et autres déchets médicaux (c’est-à-dire les caoutchoucs de silicone, les plastiques, les textiles, les papiers, les emballages, etc.)

Spécifications opérationnelles Spécifications physiques
Volume de la chambre de combustion (m3) 8,80 m3
Taux de combustion * jusqu’à 1500 kg par heure
Consommation moyenne de carburant 65 kg par heure ou plus (7 brûleurs diesel)
Température opérationnelle 850 à 1320 ° C
Rétention de gaz dans la chambre secondaire Grande chambre secondaire
Surveillance de la température Oui
Résidus de cendres moyen (%) 3%
Dispositif thermostatique Oui
Réservoir de fumée diesel 1000l
Laveur de gaz Venture
Système d’alimentation hydraulique de bélier
Grand incinérateur à moteur diesel
Spécification minimale requise

Normes
1) Soumissionnaire ou fabricant certifié ISO 9001
2) Respect des normes internationales d’émission
Caractéristiques électriques
3) Une source électrique monophasée 230V, 60Hz.
4) Protections contre les surtensions et les surintensités de la ligne.
5) Conformité aux normes et réglementations ghanéennes applicables.
Caractéristiques opérationnelles
6) Incinération en deux étapes avec combustion à double chambre
7) Taux de combustion: 15-20 Kg / h
8) Capacité: pas moins de 130 L
9) Concentrations de la plupart des polluants dans les gaz de cheminée en dessous des limites de détection
10) Carburant diesel
11) Contrôle du système électronique
12) Facile à utiliser et formation minimale
13) Tout accessoire ou appareil dédié nécessaire au bon fonctionnement et à l’utilisation de l’équipement inclus

VEUILLEZ VOUS RÉFÉRER AUX BROCHURES CI-JOINT POUR DES SPÉCIFICATIONS DÉTAILLÉES

Clover Incinerator update A model incinerator for pet cremation and animal incineration. New design accept independent movable platform in-out incinerator combustion chamber. This new design is valid for model A900 and bigger model.

pet cremation

Items/Model A900 A1200 A1500 A2400 A4000 A5500
Burning Rate *animal 30 kgs/Hr. 60 kgs/Hr. 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 80 kgs 100 kgs 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 4000 kgs 4300 kgs 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 900 1200 1500 2400 4000 5500
Secondary Chamber (Liters) 300 500 500 1200 1500 1500
External Dimensions (cm) 200x160x230 220x180x360 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 120x90x85 130x100x90 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 300 500 500 500 500
Door Opening (cm) 62 x 80 55 x 80 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 5 10 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES YES YES
Mix-Combustion Chamber YES YES YES YES YES YES
Smoke Filter Chamber YES YES YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃

 

Incinerator Program

Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

How you can find reasonable incinerator for your local site?  Incinerator is not a cheap equipment, generally the small scale version 's cost around $5, 000usd per unit and large scale version 's cost more than $50, 000usd per unit. Thus, before purchase incinerators medical treatment methods, incinerators portable, incinerators suppliers, incinerators used in laboratories, incinerators vietnam, 1 unit incinerator, you have to make clear following things:  A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment?  B, small or big? This according to the waste output every day or the waste quantity per feed time, like animal size.  C, fuel? Incinerator use gas or oil fuel, generally, gas fuel is less expensive than oil and the smoke cleaner than petroleum fuel model. However, some local site don't have gas distribution system.  And other technology products, like power(220v, 380v), waste feed door kind, incinerator structure, etc..

Items Specification
Model TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC)
Main Product List Double Combustion Chamber
Smoke Filter Chamber
PLC Mode Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

CMC Services for Inclinators for 3 years including all spares, consumables, Skilled Manpower, tools and tackles all complete. As per Scope attached as Annexure
Design, Manufacture, Supply, delivery to site, installation, testing & commission of All weather proof Passenger Inclinators in accordance to the Scope and outline specifications mentioned in Annexure
Spesifikasi Incinerator 100kg/jam

Spesifikasi dan Daftar Material

Dimensi dan Power Capacity

Nama Barang                                : INCINERATOR
Type / Model                 : PWR-INC-KMN 10
Kapasitas                                 : 100kg/Jam (1 m3)
Length                               : 288 cm  
Width                                : 147 cm  
Height                                    : 163 cm  
Height of Chimney std            : 700 cm  
TOTAL WEIGHT                   : 8000 kg 
Panel – timer                 : Digital Included Auto Alarm
Finishing                            : Hot endured paint 
Fuel tank                           : 200 Liter 
Covering Element from steel   : 3-8mm 
Banyaknya Burner                   : 2 pcs  
Banyaknya Blower               : 2 pcs 
Max. Fuel consumption           : 15-30 Liter/Jam 
Max. Elektric consumption   : 1100 Watt  
Bahan bakar               : Kerosene / Diesel (solar)  
Voltage                              : 220 V / 1 phase / 50 Hz  

Material 

1. PANEL CONTROL

Type                       : Digital 
Buatan                    : Local KAMINE ( Panel dan Incinerator satu Merek)
Voltage                   : 220 V / 1 phase / 50 Hz  
Safety operator       : Emergency Stop 
System                    : Microkontroller 
Pengoperasian         : Semi Automatic
Temperatur control  : Digital Coupler Type
Control panel : Manual dan automatic
Tipe : Self Standing Type / Wall Mounted Type
Material  : Mild steel
Thermocontrol : 2 (Dua)  1200 ºC
Set of timer : 0- 2 jam
Tombol saklar : on/off

2. CONTRUCTIONS
    
Fire Brick                  : SK 34
Castable                          : R 16
Castable          &nb
sp;         : R 14
Isolator                   : Insulating Brick serat tahan panas Keramik 1.450 ⁰ C
Element from steel     : 3-8 mm
Finishing                     : Cat Fetalit coating, Epoxy Resin (hot-endured paint)
Total berat keseluruhan     : 8.000 kg
Ketebalan Dinding Dalam : 21 Cm

3.DIMENSION OF CHAMBER (Dimensi Ruang Bakar)

Chamber 1 Ruang Bakar Utama : 100 x 100 x 98 cm = 980.000 cm3 = 0.98 m3
Chamber 2  Ruang Bakar Kedua: 40 x 100 x 98 cm = 392.000 cm3= 0.39 m3

4. EXHAUST STACK (Chimney)
         –     Diameter (inch): Ø 10″, 8″
-Panjang: 700 cm (7 m) dari permukaan tanah 
-Cerobong pertama dengan system Cor tipe MWHT
-Material Mild steel ( Baja Hitam )

5. INSTRUMENTATION & KONTROL
                      1. Suhu Control: Optimal
                           – Model: Digital
                           – Jumlah (unit): 2 (dua) unit
                           – Kontrol Mode: On-Off
                      2. Power Supply (volt / fase / herts): 15A / 220 V / 1 Phase / 50 Hz
                      3. Panel kandang: Mild Steel + powder coating
                      4. Thermocouple: K
                           – Jumlah: 2 (dua) unit
                           – Bahan: Stainless Steel + Ceramic
                      5. Timer: 0-2 Jam
                      6. De-ashing: Manual
          7. System pembuangan Abu 2 unit 
6. PINTU 
Pintu    : Baja ringan dan Linning dengan castable 
System : Double lock system ( penguncian ganda )

7. AIR SUPPLY SYSTEM 
Model / Type: fan sentrifugal 3 “
Kapasitas (m3/minute): 3.000 m3/mnt
Statis Tekanan (mmAq): 98 mmAq
Power : 200 watt/unit
Jumlah (unit): 2 (dua)

8. FUEL SYSTEM
 Pembakaran Burner:
Type: Gun type OM 2N
Bahan Bakar: Diesel Oil / Kerosene
Konsumsi Bahan Bakar: 10-18 ltr / jam
Power : 250 watt
Jumlah unit : 1 unit 

Type: Gun type OM 2N
Bahan Bakar: Diesel Oil / Kerosene
Konsumsi Bahan Bakar: 10-18 ltr / jam
Power : 250 watt
Jumlah unit : 1 unit 

9. THERMOCOPLE
Ruang bakar pertama dan kedua
Tipe : K
Protective tube : Stainless steel + ceramic
Max. temperature : 1200 ºC
Jumlah : 2 unit
Sistem pemberian umpan : Manual
Sistem pengeluaran hasil : Manual

10. TANGKI BAHAN BAKAR
Material : Mild steel
       Kapasitas : 200 liter

Horizontal Autoclave 155 Liters
Sterilizing chamber:  Steam-heated via double back wall with integrated steam generator
Door and lock:  Hinged door with quick lock and safety lock
Door seal: Blow-out design, even closure, automatic return without vacuum system
Temperature measurement technology: 2 independent sensors for controlling the steam generator + 1 sensor for sterilizing chamber
Preheating key
Security key switch saves program settings
Sterilization phase&nbs
p; indicators
Pressurized-air supply: integrated Compressor for door control circuit and pneumatic set valves
Feed water consumption per batch 0.7 to 5.6 liters
Cooling water consumption per batch for spent-steam condenser 10–25 l at temperatures 15 °C
Water-level control:  Within the double back wall
Low-water safety fuse: Heater Over temperature monitor
Sterile venting:  Membrane filter 0,2um, 0.1 m² hydrophobic, steam-sterillisable, retention  99.5%
Control circuits: separate for heater and door seal, process control and monitoring
Timer Program start by date and time
Selectable Acoustic alarm at program end
Transport security device for door 
Three Autoclave able (Polypropylene or stainless steel) Pans 5-10L 

Stoven to Cremated Pets

Basic Info.

Model NO.:used medical waste incinerator italy
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Presently, we provide different series for local customer requirements and design upgraded incinerator with our leading technology. The updated design characteristic of our assortment of incinerators make them one of the most cost effective in the world.  Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long lifetime.  * High temperature, long lifetime of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 600kgs per hour, up to 10ton daily.  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock.  Incinerator is a incineration equipment, direct fire waste by gasoline medical smokeless incinerators, medical technology fabrication italy, medical waiste furnce, medical wast burner china, medical waste 3000kcal/kg, fuel or oi fuel. As distinct circumscription, incinerator can be termed many words as under: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. 

Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 

Incinerator fuel: Gas incinerator, oil incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator producer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 

Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Item Specification
Model TS50 PLC
Main Product List per 01 set Primary Combustion Chamber
Secondary Combustion Chamber
Smoke Filter Chamber
Incinerator PLC Control Case
Chimney:5.0Meters
*(upgrade to Stainless Steel, free cost)
Italyoil/gas burner: 02 units
Oil Tank (if oil fuel): 100Liters

Incinérateurs HICLOVER

HICLOVER, Nanjing Clover Medical Technology Co., Ltd, fournit des solutions de système pour la protection de l’environnement médical, l’ingénierie de crémation des animaux et des animaux de compagnie, d’autres projets d’incinération de déchets solides municipaux.

Nous fournissons une chambre de combustion simple, des chambres de combustion doubles, trois chambres de combustion et des incinérateurs de déchets multi-chambres de combustion pour laboratoire, clinique, hôpital, centre médical, destruction des déchets cliniques d’hygiène avec jetable médical, déchets biologiques, déchets plastiques médicaux, déchets dangereux, sac rouge déchets, élimination des aiguilles, gaze et bandages, récipients tranchants scellés, déchets pathologiques, déchets de chimiothérapie à l’état de traces, etc.

Notre gamme d’incinérateurs s’adresse aux petites et grandes entreprises liées à la crémation animale, telles que les fermes avicoles, les fermes bovines, les fermes ovines, les fermes porcines, les étables, les chenils, les laboratoires d’essais, les chatteries, les crématoriums pour animaux de compagnie.

L’incinérateur brûle les déchets dans la chambre de combustion primaire et brûle à nouveau la fumée de la chambre de combustion primaire pour s’assurer que l’environnement est respectueux de l’environnement, sans fumée noire, sans odeur, et réduit l’infection bactérienne pathogène.
Solutions système pour les déchets médicaux environnementaux, y compris l’incinération des déchets, le traitement des émissions de fumée, la stérilisation à haute température, la lampe de stérilisation aux ultraviolets, le broyeur de déchets, le destructeur d’aiguilles, les colis de déchets médicaux, les conteneurs tranchants, etc.
La conception humanisée de l’équipement de crémation pour animaux de compagnie avec une plate-forme mobile, des couvertures de petit espace pour le propriétaire d’une entreprise moderne de crémation pour animaux de compagnie dans le monde entier.
L’incinérateur mobile conteneurisé monté dans un conteneur ISO avant de quitter l’usine, pré-installation, aucune construction de construction de maison d’incinération, mobile par camion et stérilisation par lampe ultraviolette à l’intérieur.
HICLOVER   est une marque en pleine croissance pour le domaine de la protection de l’environnement et des parts de marché avec la plupart des pays d’Afrique, du Moyen-Orient, d’Asie du Sud-Est et d’une partie du territoire de l’Amérique du Nord et de l’Europe. Nous sommes un partenaire de confiance pour les organisations gouvernementales, les organisations à but non lucratif, les entrepreneurs internationaux, les organisations logistiques, les militaires, les propriétaires d’entreprises de crémation pour animaux de compagnie, etc. Nous avons une expérience d’exportation dans plus de 40 pays, y compris des zones de guerre comme l’Irak, l’Afghanistan, la Somalie et le Soudan du Sud.

Nous sommes fabricant, entrepreneur et exportateur d’incinérateurs en Chine. Le fabricant fait un prix raisonnable pour le client de l’incinérateur, fournit un incinérateur médical, un incinérateur d’hôpital, des incinérateurs d’animaux, des incinérateurs de porcs, du matériel de crémation pour animaux de compagnie, un petit incinérateur, un incinérateur pour animaux de compagnie, un incinérateur pour animaux, un incinérateur portable, un incinérateur pour petits animaux, une machine de pyrolyse de déchets infectieux, un incinérateur de laboratoire. HICLOVER aide le client à réduire son budget d’achat, sa fonction personnalisée, ses produits de qualité et son service amical.

Tél: + 86-25-84610201 Courriel: [email protected] Site Web: www.hiclover.com
Principales caractéristiques:

– Incinérateur à gamme complète avec incinérateur économique à petite échelle, incinérateur standard à petite et grande échelle, incinérateur général de déchets solides municipaux, crémation des animaux de compagnie et des animaux, incinérateur mobile conteneurisé, incinérateur de déchets environnementaux à haute efficacité.

– Chambre de combustion simple, doubles chambres de combustion, trois chambres de combustion et incinérateurs de déchets multi-chambres de combustion.
– Solutions système pour les déchets médicaux environnementaux.
– Taux de combustion élevé, de 5 kg à 1000 kg par heure.
– Nouveau design pour l’entreprise de crémation d’animaux de compagnie.
– HICLOVER, partenaire de confiance avec des années d’expérience.
Articles / modèle TS10 (API) TS20 (API) TS30 (API) TS50 (API)
Taux de combustion (moyen) 10 kg / heure 20 kg / heure 30 kg / heure 50 kg / heure
Mode de contrôle PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Chambre de combustion 100 L 210 L 330 L 560 L
Dimensions internes 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Chambre secondaire 50 L 110 L 180 L 280 L
Chambre de filtre à fumée Épurateur à sec Épurateur à sec Épurateur à sec Épurateur à sec
Mode d’alimentation Manuel Manuel Manuel Manuel
Tension 220V 220V 220V 220V
Pouvoir 0,75 Kw 0,83 Kw 0.99Kw 1,2 kW
Consommation d’huile diesel (kg / heure) Ave.8.4 Ave.10.9 Ave 13.3 Ave 16.9
Consommation de gaz naturel (m3n / heure) Ave.10.1 Ave 13 Avenue 16 Ave.20.2
Moniteur de température Oui Oui Oui Oui
Protection de la température Oui Oui Oui Oui
Cuve à mazout 100 L 100 L 100 L 100 L
Porte d’alimentation 30x30cm 45 x 40 cm 55 x 50 cm 70 x 55 cm
Cheminée 3 mètres 3 mètres 5 mètres 5 mètres
Type de cheminée Acier inoxydable Acier inoxydable Acier inoxydable Acier inoxydable
1er. Température de la chambre 800 ℃ –1000 ℃ 800 ℃ –1000 ℃ 800 ℃ –1000 ℃ 800 ℃ –1000 ℃
2ème. Température de la chambre 1000 ℃ -1200 ℃ 1000 ℃ -1200 ℃ 1000 ℃ -1200 ℃ 1000 ℃ -1200 ℃
Temps de résidence 2,0 sec. 2,0 sec. 2,0 sec. 2,0 sec.
Poids brut 1 500 kg 2200 kg 3000 kg 4500 kg
Dimensions extérieures 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm
Articles / modèle TS100 (API) TS150 (API) TS300 (API) TS500 (API)
Taux de combustion (moyen) 100 kg / heure 150 kg / heure 300 kg / heure 500 kg / heure
Mode de contrôle PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Chambre de combustion 1200 L 1500 L 2000 L 3000 L
Dimensions internes 120x100x100 cm 150x100x100cm 170x120x100cm 210 x 120 x 120 cm
Chambre secondaire 600 L 750 L 1000 L 1500 L
Chambre de filtre à fumée Épurateur à sec Épurateur à sec Épurateur à sec Épurateur à sec
Mode d’alimentation Manuel Manuel Manuel Manuel
Tension 220V 220V 220V 220V
Pouvoir 1,38 kW 1,69Kw 2,57 kW 4.88Kw
Consommation d’huile diesel (kg / heure) Avenue 20.4 Avenue 24.2 Avenue 33 Avenue 44
Consommation de gaz naturel (m3n / heure) Avenue 24,5 Avenue 29 Avenue 39,6 Ave 52.8
Moniteur de température Oui Oui Oui Oui
Protection de la température Oui Oui Oui Oui
Cuve à mazout 200 L 300 L 500 L 500 L
Porte d’alimentation 80x60cm 80x60cm
Cheminée 10 mètres 10 mètres 14 mètres 14 mètres
Type de cheminée Acier inoxydable Acier inoxydable Acier inoxydable Acier inoxydable
1er. Température de la chambre 800 ℃ –1000 ℃ 800 ℃ –1000 ℃ 800 ℃ –1000 ℃ 800 ℃ –1000 ℃
2ème. Température de la chambre 1000 ℃ -1200 ℃ 1000 ℃ -1200 ℃ 1000 ℃ -1200 ℃ 1000 ℃ -1200 ℃
Temps de résidence 2,0 sec. 2,0 sec. 2,0 sec. 2,0 sec.
Poids brut 6000 kg 8500 kg 11 000 kg 16 000 kg
Dimensions extérieures 260x150x180cm 300x160x190cm 400x210x300 cm 450x210x300 cm
Controlled air medical waste incinerator designed for incineration of bio-medical waste generated at a blood-processing center. The waste to be treated mainly includes bio-waste (i.e. bodily fluids), infectious and hazardous waste such as syringes, needles, and other medical waste (i.e. silicon rubbers, plastic, textiles, papers, packs, etc.)

Operational Specs Physical Specs
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber    
Temperature Monitoring Yes    
Average ash residue (%) 3%    
Thermostatic Device Yes  
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required

Standards
1) Bidder or Manufacturer ISO 9001 Certified
2) Respecting international emission standards
Electrical characteristics
3) A 230V, 60Hz single-phase electrical source.
4) Protections against over-voltage and over-current line conditions.
5) Compliance with applicable Ghanaian standards and regulations.
Operational characteristics
6) Two-stage incineration with dual chamber combustion
7) Burn rate: 15 – 20 Kg/h
8) Capacity: not less than 130 L
9) Concentrations of most pollutants in stack gases below detection limits
10) Diesel fuel
11) Electronic system control
12) Easy to operate and minimal training
13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included

PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION

Facebook: www.facebook.com/hiclover

Twitter: twitter.com/hiclovercom

YouTube: youtube.com/c/IncineratorClover

Google+: google.com/+IncineratorClover

Biomedical Waste Incinerator

Basic Info.

Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As different circumscription, incinerator can be named many words as below: 

Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. 

Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators 

Incinerator gas: Gas incinerator, oil incinerator 

Waste to Energy (WTE): WTE incinerator, non-WTE incinerator 

Incinerator Manufacturer: China incinerator producer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. 

Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) 

Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm